Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Optics modification of the electron collector for the Relativistic Heavy Ion Collider Electron Beam Ion Source

The Electron Beam Ion Source (EBIS) for the Relativistic Heavy Ion Collider (RHIC) at the Brookhaven National Laboratory (BNL) operates with electron beam current up to 10 A and frequency up to 4-5 Hz. The observation of the vacuum conditions and the temperature of the electron repeller electrode inside the electron collector (EC) points to heavy heating of this electrode by the backscattered electrons generated by the primary electron beam on the inner surfaces of the EC. The ion optics adjacent to the EC operates at potentials of up to 50 kV and higher and the flashes of the desorbed gas may cause discharges and have detrimental effect on the vacuum conditions in the ion trap, and possible instability of the extracted ion beam. The proposed modification of the EC optics has a goal of eliminating the heating of the internal EC electrodes with preservation of the existing structure of the ion optics. The results of computer simulations of the electron beam dissipation and ion extraction are presented.

43 PARTICLE ACCELERATORS↗

Resonant Ionization Laser Ion Source (RILIS) With Improved Selectivity Achieved By Ion Pulse Compression Using In-Source Time-of-flight Technique

This paper describes for the first time the improved selectivity of the RILIS made possible by the time-of-flight (TOF) ion bunch compression. Brief description of the compression principles and some preliminary experimental results are presented. In the off-line experiments short ion peaks of natural Li, Na, K, Tm and Yb are observed as ions leave the RILIS-TOF structure. For Tm the ion peaks of 5 {mu}s half-height duration are detected and 1 {mu}s peaks for Sn are predicted. In view of the repetition rate of the ISOLDE-RILIS lasers it is hoped that the selectivity of Sn isotopes production may be improved as much as 100 employing the RILIS with the TOF ion bunch compression and a gating technique.

74 ATOMIC AND MOLECULAR PHYSICS↗

Direct 1{sup +}{yields}N{sup +} conversion of stable alkali ions using an electron cyclotron resonance ion source

The production of radioactive ions using the Isotope Separation On-Line method gives rise, in most cases, to singly charged ions. In order to perform experiments with postaccelerated radioactive ion beams, these ions have to be multicharged. We describe here a new compact design for a charge breeder that will be coupled to the production target of SPIRAL1 at GANIL. We present recent results obtained offline with stable alkali ions (Na, K, Rb, and Cs) on the SIRa test bench. Particularly, 1{sup +} to N{sup +} conversion efficiencies and conversion times are presented. Several points have been identified for the improvements of the present performances.

43 PARTICLE ACCELERATORS↗

Remarkable modulation effects of Ag{sup +} ion on fluorescence of Eu{sup 3+} ion doped yttrium phosphate nanophosphors

Highlights: ► Ag{sup +} sensitized YPO{sub 4}:Eu{sup 3+} was synthesized. ► Emission band centered at 612 nm was broadened to 14 nm. ► Ag{sup +} plays a main role for the broadening of emission band of Eu{sup 3+}. ► Emission mechanisms were discussed. - Abstract: Ag{sup +} sensitized YPO{sub 4}:Eu{sup 3+} nanomaterials were successfully synthesized by hydrothermal reaction. The fluorescent spectra indicate that Ag{sup +} ion has remarkable modulation effects on the shape of the emission bands of YPO{sub 4}:Eu{sup 3+}, so that full width at half maximum (FWHM) of the {sup 5}D{sub 0} → {sup 7}F{sub 2} emission of YPO{sub 4}:Eu{sup 3+} is extended to be 14 nm, broader than that (<9 nm) of ever reported Eu{sup 3+}-doped materials. Meanwhile, it is observed that the doping of Ag+ ion leads to the lowering of the intensity ratio of {sup 5}D{sub 0} → {sup 7}F{sub 2} to {sup 5}D{sub 0} → {sup 7}F{sub 1} transition. The analysis demonstrates that doping of Ag{sup +} ion will generate the local lattice aberration and the crystal field variation of Eu{sup 3+} ion and Y{sup 3+} ions due to a fact that the ionic radius (1.31 Å) of Ag{sup +} is obviously larger than that (0.938 Å) of Eu{sup 3+} and that (0.90 Å) of Y{sup 3+}. As a result, the excitation and emission bands of Eu{sup 3+} ion are correspondingly tuned.

36 MATERIALS SCIENCE↗

Revisiting the Role of Mobile Ion Size for the Activation Barrier of Charge Transport in Single Ion Conducting Polymers

The development of polymer electrolytes for energy storage and conversion technologies requires a fundamental understanding of the material parameters controlling the energy barriers for ion transport. In glassy polymers, these activation barriers are usually extracted by using Arrhenius procedures. However, our recent studies of single ion conducting polymers reveal that this traditional Arrhenius description provides anomalously small prefactors, an issue that is widely disregarded in the literature. Here, to address it, an alternative approach was introduced for extracting the effective activation barrier E by imposing a physically valid limit (∼10 –13 s) for the ion hopping attempt time. Two consequences of this recent approach are that in polymer electrolytes (i) E is significantly (∼30–40%) lower than the barrier estimated using traditional Arrhenius fits and (ii) E displays significant temperature dependence even in the glassy state. Under these circumstances, we are revisiting the role of ion size, glass transition temperature T g , and dielectric and elastic constants of the polymer matrix on the effective activation barriers for ion transport as extracted using the recently proposed approach and highlight the differences from the picture that previously emerged based on simplistic apparent Arrhenius analysis. To this end, we investigate cation transport in three families of single ion conducting trifluoromethane sulfonimide-based polyanions with varied T g . Our results indicate that E decreases with mobile cation size and is highly sensitive to changes in the dielectric permittivity of the matrix, even for large cations. These insights call for revisions of many earlier results based on apparent Arrhenius fits as the proposed approach can provide more accurate guidance for the design of polymer electrolytes with enhanced ionic conductivity.

energy barrier↗

Extraction of tetra-oxo anions into a hydrophobic, ionic liquid-based solvent without concomitant ion exchange.

Hydrophobic ionic liquids (IL) have the potential to simplify certain separations by serving as both an extraction solvent and an electrolyte for subsequent electrochemical reductions. While IL-based solvents are known to be efficient media for metal ion extraction, separations employing these solvents are frequently complicated by the loss of constituent IL ions to the aqueous phase, resulting in deteriorating performance. In this study, we have examined the extraction of pertechnetate and related tetra-oxo anions from aqueous solutions into IL-based solvents incorporating tetraalkylphosphonium bis[(trifluoromethyl)sulfonyl]imide and a crown ether. In contrast to various previously studied IL-based cation extraction systems, facile anion extraction without significant transfer of the IL ions to the aqueous phase has been observed. In addition, the solvents exhibit high distribution ratios (100-500 for pertechnetate), significant electrical conductivity (>100 ?S/cm), and a wide (4 V) electrochemical window. The results suggest that these solvents may provide the basis for improved approaches to the extraction and recovery of a variety of anions.

36 MATERIALS SCIENCE↗

Review on heavy ion radiotherapy facilities and related ion sources (invited)

Heavy ion radiotherapy awakens worldwide interest recently. The clinical results obtained by the Heavy Ion Medical Accelerator in Chiba at the National Institute of Radiological Sciences in Japan have clearly demonstrated the advantages of carbon ion radiotherapy. Presently, there are four facilities for heavy ion radiotherapy in operation, and several new facilities are under construction or being planned. The most common requests for ion sources are a long lifetime and good stability and reproducibility. Sufficient intensity has been achieved by electron cyclotron resonance ion sources at the present facilities.

43 PARTICLE ACCELERATORS↗

Characteristics of large amplitude compressive ion acoustic solitary wave in ion beam multicomponent plasma

Large amplitude ion acoustic compressive solitary waves are excited in a multicomponent plasma in the presence of a positive ion beam. The threshold amplitude, when steepening of the leading edge of the compressive pulse occurs, depends on the ion beam velocity. The Mach velocity and the amplitude of large amplitude compressive solitary waves are measured for different ion beam velocities. The amplification of the large amplitude compressive solitary wave is observed when the ratio of the ion beam velocity divided by the ion acoustic velocity is in the range of 0.8-1.4. The maximum amplitude of the density perturbation observed in the experiment is quite large (approx170%).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear and nonlinear quantum ion acoustic waves in a plasma with positive, negative ions and Fermi electron gas

Linear and nonlinear propagations of quantum ion acoustic waves in positive, negative ions and electron plasma have been vetted via the dispersion relation and Korteweg-de Vries equation, where the ions are inertial and electrons are inertialess. The quantum mechanical effects arising due to the quantum diffraction and Fermi-Dirac statistics for this system are taken into account. The existence, as well as the type (compressive/rarefactive) of solitary wave propagating in the system, is strongly dependent on the numerical value of dimensionless quantum parameter H{sub e}. It is observed that negative ion population and ion mass ratio have emphatic influence on the phase velocity of ion acoustic wave and the propagation of localized coherent solitary structures at quantum scale in the system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion acoustic solitons in unmagnetized inhomogeneous multi-ion component plasmas with vortex distributed electrons

The ion acoustic solitons are studied in an inhomogeneous multi-ion component plasma in the presence of heavy and light adiabatic ions and two temperature electrons with vortex distribution. The modified Korteweg-de Vries equation with an additional term due to density gradients is derived by employing reductive perturbation technique. It is found that the amplitude of the soliton enhances as the concentration ratio of cold to hot electrons, density gradient parameter and ion temperature are increased in the system. The effects of mass, charge ratios of heavy to light ions and electron temperature are also investigated on the structural as well as propagation characteristics of solitary wave. The equilibrium density profile is taken to be exponential. The phase velocity of ion acoustic wave is also studied as a function of various plasma parameters. The numerical results are presented for illustration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative control of magnetic ordering in FeRh thin films using 30 keV Ga ion irradiation from a focused ion beam system

We investigated a low-energy ion-beam irradiation process for the magnetic modification of FeRh thin films using a focused ion beam system. Low-energy ion-beam irradiation induced ferromagnetic states in the FeRh thin films at low temperatures, that originally exhibited antiferromagnetism, as effectively as high-energy ion-beam irradiation. Because the energy deposited by the elastic collisions caused by the irradiation determined the magnetic properties of the samples, the magnetic state of the FeRh thin films could be quantitatively controlled. The low-energy ion-beam irradiation using a focused ion beam system is a potential technique to modify the magnetic properties of materials on the nano- and micro-scales, which may lead to a variety of novel spin devices and applications.

36 MATERIALS SCIENCE↗

The double electrostatic ion ring experiment: A unique cryogenic electrostatic storage ring for merged ion-beams studies

We describe the design of a novel type of storage device currently under construction at Stockholm University, Sweden, using purely electrostatic focussing and deflection elements, in which ion beams of opposite charges are confined under extreme high vacuum cryogenic conditions in separate ''rings'' and merged over a common straight section. The construction of this double electrostatic ion ring experiment uniquely allows for studies of interactions between cations and anions at low and well-defined internal temperatures and centre-of-mass collision energies down to about 10 K and 10 meV, respectively. Position sensitive multi-hit detector systems have been extensively tested and proven to work in cryogenic environments and these will be used to measure correlations between reaction products in, for example, electron-transfer processes. The technical advantages of using purely electrostatic ion storage devices over magnetic ones are many, but the most relevant are: electrostatic elements which are more compact and easier to construct; remanent fields, hysteresis, and eddy-currents, which are of concern in magnetic devices, are no longer relevant; and electrical fields required to control the orbit of the ions are not only much easier to create and control than the corresponding magnetic fields, they also set no upper mass limit on the ions that can be stored. These technical differences are a boon to new areas of fundamental experimental research, not only in atomic and molecular physics but also in the boundaries of these fields with chemistry and biology. For examples, studies of interactions with internally cold molecular ions will be particular useful for applications in astrophysics, while studies of solvated ionic clusters will be of relevance to aeronomy and biology.

43 PARTICLE ACCELERATORS↗

Simulation Studies of Hydrogen Ion reflection from Tungsten for the Surface Production of Negative Hydrogen Ions

The production efficiency of negative ions at tungsten surface by particle reflection has been investigated. Angular distributions and energy spectra of reflected hydrogen ions from tungsten surface are calculated with a Monte Carlo simulation code ACAT. The results obtained with ACAT have indicated that angular distributions of reflected hydrogen ions show narrow distributions for low-energy incidence such as 50 eV, and energy spectra of reflected ions show sharp peaks around 90% of incident energy. These narrow angular distributions and sharp peaks are favorable for the efficient extraction of negative ions from an ion source equipped with tungsten surface as negative ionization converter. The retained hydrogen atoms in tungsten lead to the reduction in extraction efficiency due to boarded angular distributions.

43 PARTICLE ACCELERATORS↗

Laser measurement of H{sup -} ions in a field-effect-transistor based radio frequency ion source

Hydrogen negative ion density measurements are required to clarify the characteristics of negative ion production and ion source performance. Both of laser photodetachment and cavity ring down (CRD) measurements have been implemented to a field-effect-transistor based radio-frequency ion source. The density ratio of negative hydrogen ions to electrons was successfully measured by laser photodetachment and effect of magnetic filter field on negative ion density was confirmed. The calculated CRD signal showed that CRD mirrors with >99.990% reflectivity are required and loss of reflectivity due to cesium contamination should be minimized.

43 PARTICLE ACCELERATORS↗

Quasi-periodic behavior of ion acoustic solitary waves in electron-ion quantum plasma

The ion acoustic solitary waves are investigated in an unmagnetized electron-ion quantum plasmas. The one dimensional quantum hydrodynamic model is used to study small as well as arbitrary amplitude ion acoustic waves in quantum plasmas. It is shown that ion temperature plays a critical role in the dynamics of quantum electron ion plasma, especially for arbitrary amplitude nonlinear waves. In the small amplitude region Korteweg-de Vries equation describes the solitonic nature of the waves. However, for arbitrary amplitude waves, in the fully nonlinear regime, the system exhibits possible existence of quasi-periodic behavior for small values of ion temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effect of ion temperature on ion-acoustic solitary waves in a magnetized plasma in presence of superthermal electrons

Obliquely propagating ion-acoustic soliatry waves are examined in a magnetized plasma composed of kappa distributed electrons and fluid ions with finite temperature. The Sagdeev potential approach is used to study the properties of finite amplitude solitary waves. Using a quasi-neutrality condition, it is possible to reduce the set of equations to a single equation (energy integral equation), which describes the evolution of ion-acoustic solitary waves in magnetized plasmas. The temperature of warm ions affects the speed, amplitude, width, and pulse duration of solitons. Both the critical and the upper Mach numbers are increased by an increase in the ion temperature. The ion-acoustic soliton amplitude increases with the increase in superthermality of electrons. For auroral plasma parameters, the model predicts the soliton speed, amplitude, width, and pulse duration, respectively, to be in the range of (28.7-31.8) km/s, (0.18-20.1) mV/m; (590-167) m, and (20.5-5.25) ms, which are in good agreement with Viking observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements for extending the time between maintenance periods for the Heidelberg ion beam therapy center (HIT) ion sources

The clinical operation at the Heidelberg Ion Beam Therapy Center (HIT) started in November 2009; since then more than 1600 patients have been treated. In a 24/7 operation scheme two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce protons and carbon ions. The modification of the low energy beam transport line and the integration of a third ion source into the therapy facility will be shown. In the last year we implemented a new extraction system at all three sources to enhance the lifetime of extraction parts and reduce preventive and corrective maintenance. The new four-electrode-design provides electron suppression as well as lower beam emittance. Unwanted beam sputtering effects which typically lead to contamination of the insulator ceramics and subsequent high-voltage break-downs are minimized by the beam guidance of the new extraction system. By this measure the service interval can be increased significantly. As a side effect, the beam emittance can be reduced allowing a less challenging working point for the ion sources without reducing the effective beam performance. This paper gives also an outlook to further enhancements at the HIT ion source testbench.

43 PARTICLE ACCELERATORS↗