Integrating High Levels of Inverter-Based Resources into Power Grids
The presentation discusses the current state-of-the-art and challenges of integrating high level of inverter-based resources into the power system.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
The presentation discusses the current state-of-the-art and challenges of integrating high level of inverter-based resources into the power system.
This presentation discusses the methodology for developing moisture ingress models for components inside a PV inverter. This method uses time series-based analyses for moisture ingress unlike a single maximum temperature, humidity, and voltage setpoint used in Hallberg-Peck equations. Experiments were performed for determination of moisture ingress time to estimate moisture ingress in and out of the capacitor device under normal and extreme temperatures and RH conditions.
We consider the problem of controlling the frequency of low-inertia power systems via inverter-based resources (IBRs) that are weakly connected to the grid. We propose a novel grid-forming control strategy, the so-called frequency shaping control, that aims to shape the frequency response of synchronous generators (SGs) to load perturbations so as to efficiently arrest sudden frequency drops. Our solution relaxes several existing assumptions in the literature and is able to navigate trade-offs between peak power requirements and maximum frequency deviations. Finally, we analyze the robustness to imperfect knowledge of network parameters, while particularly highlighting the importance of accurate estimation of these parameters.
Smart inverters (SI) have huge potential in providing grid services which has not been fully realized yet. One of these grid services, distribution network voltage regulation by SI, can improve the network voltage by regulating the SI reactive and active power output. Voltage regulation by SI is much faster compared to traditional voltage regulating devices, e.g. tap changing transformer, capacitor banks. However, there is gap in available published literature on the characteristics of SIs when the SI is controlled by local controller or external control signal. This paper presents the experimental study to characterize SI reactive power regulation response to two different control methods: autonomous control method and remote dispatch method. It was found that IS reactive power regulation response could be significantly different in terms of delay, and ramp rate for these two methods. Finally, Power-Hardware-in-The-Loop (PHIL) tests were conducted to evaluate the performance of these two methods. The PHIL tests results show that SI response characteristics for autonomous control method and remote dispatch method need to be considered during planning for distribution network voltage regulation using SI.
This study addresses the compliance of Inverter-based Resources (IBRs) with the IEEE Std 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a comprehensive controller development framework. This framework caters to maintaining ride-trhough operation or implementing strategic disconnections in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.
This presentence provides overview of NREL's testing capabilities and experience with advanced testing of multimegawatt grid-forming inverters.
Project overcomes frequency stability and system control issues when operating distribution microgrids in a low inertia, high PV penetration environment without fossil fuel generators. The team implemented a grid-forming inverter and advanced control features at SDG&E's Borrego Springs Microgrid to demonstrate islanding and blackstart using renewable resources. Simulation and emulation in advance of deployment de-risks field operations.
This presentation talks about different failure modes and corresponding detection schemes of PV panels, PV inverters, electric machines such as motors and power converter. Several novel techniques have been presented that are capable of measuring degradation as well as detecting faults in various location in a PV based power system.
This study addresses the compliance of Inverter-based Resources (IBRs) with IEEE Standard 2800, a leading standard that defines interconnection and interoperability requirements for IBRs integrated into transmission systems. Focusing on abnormal grid scenarios, the research evaluates the specific demands on IBRs, proposing a controller development framework for abnormal grid conditions. This framework caters to maintaining ride-through operation in line with IEEE Std 2800, alongside managing currents during voltage ride-through scenarios. The effectiveness of this proposed controller framework is rigorously validated through case studies, employing a MATLAB/Simulink model of an IBR to test its performance under diverse grid fault conditions, ensuring the IBRs' alignment with standard requirements and their robust performance in enhancing grid reliability.
The increasing penetration of inverter-based resources (IBRs) is reshaping the dynamic behavior of power systems. IEEE standard 1547-2018 suggests that distributed energy resources (DERs) should provide grid services such as voltage and frequency supports. On the other hand, dynamic events caused by IBRs such as sub-synchronous oscillation have been reported. These developments necessitate improvement in the current modeling capabilities to better understand the interdependencies within power systems. These include interactions between transmission and distribution systems, among IBRs themselves, and between IBRs and conventional resources. In this paper, we present a co-simulation model integrating PSS/E, OpenDSS, and PSCAD to analyze IBR impacts on the stability of transmission and distribution systems. A key challenge in developing a co-simulation model is ensuring interoperability among different simulators (interfacing and data flow) while maintaining accurate results. Using the developed model, we simulate the impact of IBRs on power systems in two test cases: 1) fault ride through (FRT) capability during a generation trip contingency; 2) IBR-induced sub-synchronous oscillation. The results show the effectiveness of the co-simulation model.
This presentation addresses the security challenges posed by Inverter-Based Resources (IBRs) in the modern energy landscape. The presentation highlights the vulnerabilities and risks associated with IBRs, including the potential for cyber-attacks, the impact of insecure defaults, and the systemic risks posed by supply chain dependencies. Key topics covered include: 1) The increasing digital transformation in energy systems and the associated security risks. 2) Specific vulnerabilities in IBRs, including weak passwords, hardcoded credentials, and insecure web application interfaces. 3) The implications of persistent connectivity and the strategic risks posed by foreign-manufactured components. 4) The role of regulatory frameworks, such as NERC CIP, in addressing these challenges and the limitations of current oversight. 5) Practical solutions for mitigating risks, including secure design practices, vendor risk assessments, and the importance of strong passwords and role-based access control. The presentation underscores the necessity of a comprehensive, system-of-systems approach to securing IBRs, emphasizing the need for collaboration across various stakeholders, including operators, developers, and regulators, to ensure the resilience and security of the energy grid.
Inverted p‐i‐n structure perovskite solar cells (PSCs) have outperformed traditional n‐i‐p PSCs in recent years. A key advancement is the use of self‐assembled monolayers (SAMs) as hole transport layers. One class of widely used SAMs is carbazole‐based phosphonic acids. However, it is found that these SAMs lack strong binding with transparent conducting oxides (TCO) and perovskite. The weak binding strength results in suboptimal interfacial adhesion of the buried interface, which limits the device's stability. Here, interfacial binding is enhanced by increasing the dipole moment that creates a strong interfacial electric field that enhances electrostatic interactions at the TCO/perovskite interface, while incorporating tailored functional groups in SAMs to improve chemical anchoring to TCO and binding to perovskite. Specifically, the donor‐acceptor SAM molecule 4‐(7‐(4‐(bis(4‐methoxyphenyl)amino)‐2,5‐difluorophenyl)benzo[c][1,2,5]thiadiazol‐4‐yl)benzoic acid (PAFTB) is employed, which features an enhanced dipole moment along with electron‐donating and electron‐withdrawing functional groups to optimize interfacial interactions. Compared to extensively used [2‐(9H‐carbazol‐9‐yl)ethyl]phosphonic acid (2PACz), PAFTB enhances total interfacial adhesion by 2.8 times, thereby improving the thermal stability of the layer. Using this approach, PSCs are demonstrated with a certified quasi‐steady‐state power conversion efficiency of 24.9% and maintain 80% of the initial efficiency after 900 h of maximum power point tracking at 85 °C.
Abstract Inverted metamorphic Ga 0.3 In 0.7 As photovoltaic converters with sub‐0.60 eV bandgaps grown on InP and GaAs are presented. Threading dislocation densities are 1.3 ± 0.6 × 10 6 and 8.9 ± 1.7 × 10 6 cm −2 on InP and GaAs, respectively. The devices generate open‐circuit voltages of 0.386 and 0.383 V, respectively, under irradiance producing a short‐circuit current density of ≈10 A cm −2 , yielding bandgap‐voltage offsets of 0.20 and 0.21 V. Power and broadband reflectance measurements are used to estimate thermophotovoltaic (TPV) efficiency. The InP‐based cell is estimated to yield 1.09 W cm −2 at 1100 °C versus 0.92 W cm −2 for the GaAs‐based cell, with efficiencies of 16.8 versus 9.2%. The efficiencies of both devices are limited by sub‐bandgap absorption, with power weighted sub‐bandgap reflectances of 81% and 58%, respectively, the majority of which is assumed to occur in the graded buffers. The 1100 °C TPV efficiencies are estimated to increase to 24.0% and 20.7% in structures with the graded buffer removed, if previously demonstrated reflectance is achieved. These devices also have application to laser power conversion in the 2.0–2.3 µm atmospheric window. Peak laser power converter efficiencies of 36.8% and 32.5% are estimated under 2.0 µm irradiances of 1.86 and 2.81 W cm −2 , respectively.
In donor–acceptor dyads undergoing photoinduced electron transfer (PET), a direction or pathway for electron movement is usually dictated by the redox properties and the separation distance between the donor and acceptor subunits, while the effect of symmetry is less recognized. We have designed and synthesized two isomeric donor–acceptor assemblies in which electronic coupling between donor and acceptor is altered by the orbital symmetry control with the reorganization energy and charge transfer exothermicity being kept unchanged. Analysis of the optical absorption and luminescence spectra, supported by the DFT and TD-DFT calculations, showed that PET in these assemblies corresponds to the Marcus inverted region (MIR) and has larger rate for isomer with weaker electronic coupling. This surprising observation provides the first experimental evidence for theoretically predicted adiabatic suppression of PET in MIR, which unambiguously controlled solely by symmetry.
Solutions for improving fast charging of lithium‐ion batteries have largely focused on alleviating through‐plane lithiation gradients while little is understood about in‐plane heterogeneities and how to resolve them. Herein, high‐speed synchrotron X‐ray diffraction (XRD) resolves graphite lithiation spatially and temporally during 6 C charging and 2 C discharging. At every point during operation, considerable differences in the state of lithiation across the pouch cell are present. Some regions are more responsive to operation than others, reaching full lithiation early during charge and full delithiation during discharge. Other regions within the cell never fully delithiate during discharge, despite a prolonged voltage hold at 2.8 V. Using time‐resolved XRD data, the calculated local current density (mA cm −2 ) at the graphite surface shows an unexpected occurrence of local inverted current densities where regions of graphite are observed to delithiate during charging and lithiate during discharging. A pseudo‐3D model is developed for the graphite electrode with spatially varying microstructural tortuosity to show how microstructural heterogeneity could influence spatial charge dynamics. The model could not predict the complex in‐plane charge behavior observed within the cell. Consequently physics‐based charging protocols based on homogeneous electrode assumptions may underestimate the local variations in charge dynamics and occurrence of lithium plating.
The hole‐transporting material (HTM) in perovskite solar cells (PSCs) provides an ideal interface with the perovskite layer for hole collection while influencing the perovskite crystalline structure and morphology. This article presents SIM and DIM, two new dopant‐free imidazolium‐based HTMs with charged units accompanied by counter ions that show the potential to function as ionic HTMs and ionic liquid additives and help improve the efficiency and stability of inverted PSCs. DIM‐based PSCs demonstrates exceptional performance with a high‐power conversion efficiency of 19.15%, attributed to improved passivation of perovskite interface defects. Furthermore, these new imidazolium salt‐based HTMs can be manufactured economically, making them a viable option for mass production and PSC commercialization.
We first compute the effect of a chiral anomaly, charge, and a magnetic field on the entanglement entropy in $\mathcal{N}$ = 4 Super-Yang-Mills theory at strong coupling via holography. Depending on the width of the entanglement strip the entanglement entropy probes energy scales from the ultraviolet to the infrared energy regime of this quantum field theory (QFT) prepared in a given state. From the entanglement entropy, we compute holographic c-functions and demonstrate an inverted c-theorem for them. That is, these c-functions in generic thermal states monotonically increase towards the infrared (IR) energy regime. This is in contrast to the c-functions in vacuum states which decrease along the renormalization group flow towards the IR regime of a renormalizable QFT. Furthermore, in thermal states and in the IR limit, the c-functions behave thermally, growing proportionally to the value of the thermal entropy. The chiral anomaly affects the c-functions more in the IR regime, and its effect is peaked at an intermediate value of the magnetic field at a fixed chemical potential and temperature.
Abstract We discuss two-dimensional conformal field theories (CFTs) which are invariant under gauging a non-invertible global symmetry. At every point on the orbifold branch ofc= 1 CFTs, it is known that the theory is self-dual under gauging a ℤ 2 × ℤ 2 symmetry, and has Rep(H 8 ) and Rep(D 8 ) fusion category symmetries as a result. We find that gauging the entire Rep(H 8 ) fusion category symmetry maps the orbifold theory at radiusRto that at radius 2/R. AtR=$$ \sqrt{2} $$ 2 , which corresponds to two decoupled Ising CFTs (Ising 2 in short), the theory is self-dual under gauging the Rep(H 8 ) symmetry. This implies the existence of a topological defect line in the Ising 2 CFT obtained from half-space gauging of the Rep(H 8 ) symmetry, which commutes with thec= 1 Virasoro algebra but does not preserve the fully extended chiral algebra. We bootstrap its action on thec= 1 Virasoro primary operators, and find that there are no relevant or marginal operators preserving it. Mathematically, the new topological line combines with the Rep(H 8 ) symmetry to form a bigger fusion category which is a ℤ 2 -extension of Rep(H 8 ). We solve the pentagon equations including the additional topological line and find 8 solutions, where two of them are realized in the Ising 2 CFT. Finally, we show that the torus partition functions of the Monster 2 CFT and Ising×Monster CFT are also invariant under gauging the Rep(H 8 ) symmetry.