Systems and methods for assessing cable insulation

Methods for assessing cable insulation are provided that can include engaging a first tine gap interdigital capacitor assembly with the exterior of the cable jacket to determine a first capacitance and dissipation factor value of the insulation using the first tine gap interdigital capacitor assembly; engaging a second tine gap interdigital capacitor assembly with the exterior of the cable jacket to determine a second capacitance and dissipation factor value of the insulation using the second tine gap interdigital capacitor assembly.Systems for assessing cable insulation are also provided. The systems can include a cable jacket encompassing cable insulation and conductive material; at least two tine gap interdigital capacitor assemblies engaged with the cable jacket; and processing circuitry operatively engaged with the capacitor assemblies.

Glass, III, Samuel W.↗

ITER CENTRAL SOLENOID COIL INSULATION QUALIFICATION

An insulation system for ITER Central Solenoid must have sufficiently high electrical and structural strength. Design efforts to bring stresses in the turn and layer insulation within allowables failed. It turned out to be impossible to eliminate high local tensile stresses in the winding pack. When high local stresses can not be designed out, the qualification procedure requires verification of the acceptable structural and electrical strength by testing. We built two 4 x 4 arrays of the conductor jacket with two options of the CS insulation and subjected the arrays to 1.2 million compressive cycles at 60 MPa and at 76 K. Such conditions simulated stresses in the CS insulation. We performed voltage withstand tests and after end of cycling we measured the breakdown voltages between in the arrays. After that we dissectioned the arrays and studied micro cracks in the insulation. We report details of the specimens preparation, test procedures and test results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Whole building retrofit using vacuum insulation panels and energy performance analysis

Vacuum insulation panels (VIPs), due to their high thermal performance, provide an attractive alternative to traditional building insulation materials, especially as an option for retrofitting old, poorly insulated buildings. This article describes the complete retrofit of all exterior walls of a single-story building in a cold climate using VIPs. A recently-developed low-cost VIP, called modified atmosphere insulation (MAI), was used in this study. Two buildings of near-identical construction were studied, with one remaining unaltered and serving as the baseline while the other served as the retrofit building. The VIPs or MAI panels proved to be a feasible and durable option for retrofitting building envelopes. Thermal performance of both buildings was analyzed using in-situ temperature and heat flow sensors. Numerical models of the two buildings were created, benchmarked using experimental data and used for predictions of annual energy savings due to the addition of MAI panels to the exterior walls. The models predicted significant reduction in the annual heating energy consumption in the retrofitted building compared to the baseline building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hermetically sealed porous-wall hollow microspheres enabled by monolithic glass coatings: Potential for thermal insulation applications

Thermal insulation materials are crucial to improve the energy performance of buildings and industrial applications. We report an approach to create hermetically vacuum-sealed silica-based hollow microspheres that can lower the thermal conductivity of closed-cell insulation materials. The wall structure of these hollow microspheres includes a reticulated network of pores or channels that extend through the thickness of the wall. When a thin layer of glass material is applied to the wall exterior, followed by a vacuum-assisted thermal treatment process, the coated microsphere surfaces display a highly dense conformal coverage and near-complete elimination of surface porosity. The sealing efficiency of these microspheres is verified by trapping argon within their cavities as well as through evacuating their hollow cores. Notably, incorporating the evacuated microspheres into a polymer matrix resulted in ~27% enhancement in its thermal insulation performance and no notable loss of performance was observed following three months of exposure to ambient conditions. Thus, we believe that the present study offers a commercially viable strategy that opens the door to applications of such inorganic hollow particles in areas ranging from vacuum-based thermal insulation systems to catalysis, separation technologies, and medical fields.

36 MATERIALS SCIENCE↗

Dynamics of voltage-driven oscillating insulator-metal transitions

Recent experiments demonstrated emerging alternating insulator and metal phases in Mott insulators actuated by a direct bias voltage, leading to oscillating voltage outputs with characteristic frequencies. Here, we develop a physics-based nonequilibrium model to describe the dynamics of oscillating insulator-metal phase transitions and experimentally validate it using a VO 2 device as a prototype. The oscillation frequency is shown to scale monotonically with the bias voltage and series resistance and terminate abruptly at lower and upper device-dependent limits, which are dictated by the nonequilibrium carrier dynamics. Here, we derive an approximate analytical expression for the dependence of the frequency on the device operating parameters, which yields a fundamental limit to the frequency and may be utilized to provide guidance to potential applications of insulator-metal transition materials as building blocks of brain-inspired non-von Neumann computers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies

The Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in Westford, MA. Featured speakers included John Straube, Christopher Schumacher and Kohta Ueno of Building Science Corporation, Henri Fennell of Building Envelope Solutions, Inc., and Mark Bomberg of Syracuse University. Some ad hoc presentations were given by practitioners in the audience as well. This was followed by a question-and-answer period and discussion. Key results from this meeting were: • Greater understanding of the state-of-art in assessing risks or and performing interior insulation retrofit of mass masonry wall assemblies • Greater understanding of the uncertainties in assessments • Definition of key research needs to investigate and potentially reduce uncertainties. Extensive information was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks. It was found that conflicting understanding exists, such as general assessment approaches, assessments of masonry material properties, and the inclusion of air spaces between insulation and masonry units in hygrothermal analysis. Little research has been conducted on these issues, as well other major key issues such as the impact the architectural detailing has on rainwater concentration, timber beam pocket strategies, and below grade strategies. The next steps are to define projects to address the research needs identified at the meeting. One upcoming retrofit was put forward as an opportunity to experiment with methodologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Affordable Cold Climate Infill Housing with Hybrid Insulation Approach, Wyandotte, Michigan (Fact Sheet)

Even builders who are relatively new to energy-efficient construction can consistently reach a target whole house airtightness of 1.5 air changes per hour at 50 Pascals (ACH50) with high R-value enclosures that use a hybrid insulation approach. The City of Wyandotte, Michigan, started a construction program in 2010 to build affordable, energy-efficient homes on lots in existing neighborhoods. A goal of the program was to engage local builders in energy-efficient construction and be able to deliver the new houses for less than $100/ft2. By the end of 2012, approximately 25 new houses were built by five local builders under this program. To help builders consistently achieve the airtightness target, a local architect worked with researchers from Building Science Corporation, a U.S. Department of Energy Building America team, to develop a technology specification with several key pieces. A high R-value wall and roof assembly made use of 2 ?6 advanced framing and a hybrid insulation approach that included insulating sheathing to control thermal bridging and closed cell spray polyurethane foam insulation (ccSPF) for its airtightness and vapor control benefits. This approach allows the air barrier to be completed and tested before any finishing work occurs, ensuring that problems are spotted and corrected early in the construction process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cladding Attachment Over Thick Exterior Insulating Sheathing (Fact Sheet)

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of wood-framed walls and mass masonry wall assemblies. The location of the insulation on the exterior of the structure has many direct benefits, including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased airtightness and improved water management. For thick layers of exterior insulation (more than 1.5 in.), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. Although the approach has proven effective, there is significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved in the development of the vertical displacement resistance capacity. In addition, the long-term in-service performance of the system has been questioned due to potential creep effects of the assembly under the sustained dead load of the cladding and effects of varying environmental conditions. In addition, the current International Building Code (IBC) and International Residential Code (IRC) do not have a provision that specifically allows this assembly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location (Straube and Smegal 2009, Pettit 2009, Joyce 2009, Ueno 2010). The research presented in this report is intended to help develop a better understanding of the system mechanics involved and the potential for environmental exposure induced movement between the furring strip and the framing. BSC sought to address the following research questions: 1. What are the relative roles of the mechanisms and the magnitudes of the force that influence the vertical displacement resistance of the system? 2. Can the capacity at a specified deflection be reliably calculated using mechanics based equations? 3. What are the impacts of environmental exposure on the vertical displacement of furring strips attached directly through insulation back to a wood structure?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spray Foam Exterior Insulation with Stand-Off Furring

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders will be required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. This research was an extension on previous research conducted by Building Science Corporation in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading, has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full year’s worth of cladding movement data from assemblies constructed in an exposed outdoor environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spray Foam Exterior Insulation with Stand-Off Furring

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using "L" clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and "picture framing" the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cladding Attachment Over Thick Exterior Insulating Sheathing

The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location (Straube and Smegal 2009, Pettit 2009, Joyce 2009, Ueno 2010). The research presented in this report is intended to help develop a better understanding of the system mechanics involved and the potential for environmental exposure induced movement between the furring strip and the framing. BSC sought to address the following research questions: 1.What are the relative roles of the mechanisms and the magnitudes of the force that influence the vertical displacement resistance of the system? 2.Can the capacity at a specified deflection be reliably calculated using mechanics based equations? 3.What are the impacts of environmental exposure on the vertical displacement of furring strips attached directly through insulation back to a wood structure?

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attic Retrofits Using Nail-Base Insulated Panels

This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Activation of Thermal Insulation and Contamination Prevention

The goals of this paper are to enhance the understanding of the potential activation and contamination hazards from the use of insulating materials in the Molten Chloride Reactor Experiment and to foster safer work environments through informed decision-making and strategic planning. It was written to resolve a gating comment from the core heating system preliminary design review. The largest dose expected from the considered insulation materials is about 0.1 mrem per year from Pyrogel. Although Cerablanket stood out among the insulation materials for encouraging ALARA practices, it has a higher thermal conductivity. At low power levels, focusing on reducing the generation of dust from ERD activities may be more effective for reducing the potential spread of contamination than changing the insulating material type. However, regardless of the material chosen, PPE and safety conscious procedural practices can help reduce the production and spread of activated dust––thus minimizing the radiological hazard to workers.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Excavationless Exterior Foundation Insulation Field Study - Minnesota

The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were originally selected for this field study. One was not ready for retrofit at the time of study and had to be eliminated. The collaborative nature of the one field installation, however, enabled the team to advance the methodology as the work progressed. Improvements to the method of installation and reduction of costs were developed on site. This is a repository for all "excavationless" foundation insulation retrofit projects performed by the NorthernSTAR research team. Minneapolis, MN 55411 - Test house for first NorthernSTAR excavationless foundation insulation retrofit.

Array↗

Building America Case Study: Initial and Long-Term Movement of Cladding Installed Over Exterior Rigid Insulation (Fact Sheet)

Changes in the International Energy Conservation Code (IECC) from 2009 to 2012 have resulted in the use of exterior rigid insulation becoming part of the prescriptive code requirements. With more jurisdictions adopting the 2012 IECC builders are going to finding themselves required to incorporate exterior insulation in the construction of their exterior wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location. However, there has been a significant resistance to its widespread implementation due to a lack of research and understanding of the mechanisms involved and potential creep effects of the assembly under the sustained dead load of a cladding. This research was an extension on previous research conducted by BSC in 2011, and 2012. Each year the understanding of the system discrete load component interactions, as well as impacts of environmental loading has increased. The focus of the research was to examine more closely the impacts of screw fastener bending on the total system capacity, effects of thermal expansion and contraction of materials on the compressive forces in the assembly, as well as to analyze a full years worth of cladding movement data from assemblies constructed in an exposed outdoor environment.