Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Implants”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Wireless Performance of a Fully Passive Neurorecording Microsystem Embedded in Dispersive Human Head Phantom

This paper reports the wireless performance of a biocompatible fully passive microsystem implanted in phantom media simulating the dispersive dielectric properties of the human head, for potential application in recording cortical neuropotentials. Fully passive wireless operation is achieved by means of backscattering electromagnetic (EM) waves carrying 3rd order harmonic mixing products (2f(sub 0) plus or minus f(sub m)=4.4-4.9 GHZ) containing targeted neuropotential signals (fm approximately equal to 1-1000 Hz). The microsystem is enclosed in 4 micrometer thick parylene-C for biocompatibility and has a footprint of 4 millimeters x 12 millimeters x 500 micrometers. Preliminary testing of the microsystem implanted in the lossy biological simulating media results in signal-to-noise ratio's (SNR) near 22 (SNR approximately equal to 38 in free space) for millivolt level neuropotentials, demonstrating the potential for fully passive wireless microsystems in implantable medical applications.

Schwerdt, Helen N.↗

Solar Ion Processing of Itokawa Grains: Constraints on Surface Exposure Times

Analytical TEM observations obtained to date reveal that a significant sub-population of grains returned from the surface of asteroid Itokawa have had their outer 30-100 nm processed by space weathering effects. Although the effects include some surface deposition of condensed impact vapor and isolated impact melt splashes, much of the width of the space weathered outer margins or "rims" on grains is derived from solar wind processing of the original host grain. Similar to what has long been reported for some lunar grains, the ion-processed rims on Itokawa grains exhibit varing degrees and depths of penetration of atomic-displacement ion damage, resulting in complete amorphization for some rims (particularly in plagioclase), or formation of highly defective but still crystalline structures in others (particularly in pyroxene and olivine). Possibly different from lunar grains, however, is the presence of isolated internal cavities or voids in Itokawa grain rims, which may be implantation "bubbles" due to accumulating implanted solar wind H and/or He. For a given mineral exposed at a particular set of long term solar wind conditions, the level of ion damage in a given grain rim, the depth of damage penetration represented by the rim width, and the formation or lack of formation of implantation bubbles can all be linked to the time spent by the grain in an uncovered state on the topmost, space-exposed, regolith surface. For the lunar case, we have previously shown that with reasonable assumptions about solar wind characteristics over time, a model can be developed to estimate this exposure time based on the width of amorphous rims on lunar grains. Here we report on an expansion of the model to cover exposure time information contained in the array of solar ion-induced features in Itokawa grains.

Christoffersen, R.↗

A Wirelessly Powered Micro-Spectrometer for Neural Probe-Pin Device

Treatment of neurological anomalies, places stringent demands on device functionality and size. A micro-spectrometer has been developed for use as an implantable neural probe to monitor neuro-chemistry in synapses. The microspectrometer, based on a NASA-invented miniature Fresnel grating, is capable of differentiating the emission spectra from various brain tissues. The micro-spectrometer meets the size requirements, and is able to probe the neuro-chemistry and suppression voltage typically associated with a neural anomaly. This neural probe-pin device (PPD) is equipped with wireless power technology (WPT) enabling operation in a continuous manner without requiring an implanted battery. The implanted neural PPD, together with a neural electronics interface and WPT, allow real-time measurement and control/feedback for remediation of neural anomalies. The design and performance of the combined PPD/WPT device for monitoring dopamine in a rat brain will be presented to demonstrate the current level of development. Future work on this device will involve the addition of an embedded expert system capable of performing semi-autonomous management of neural functions through a routine of sensing, processing, and control.

Choi, Sang H.↗

DC Modeling of 4H-SiC JFET Gate Length Reduction at 500°C

The development of robust, high-performance integrated circuits (ICs) will enable numerous potential NASA missions of current interest, including long-duration robotic missions exploring the 460 °C surface of Venus. Currently, NASA is looking towards SiC-based devices to provide such a solution. However, the current NASA silicon carbide (SiC) JFET device with a channel length of 6μm (for recently fabricated Gen. 11 ICs) limits on mission relevant circuit capabilities [1]. In this study, we combined experiments with simulations to explore two straightforward fabrication strategies to reduce the SiC JFET channel length while maintaining turn-off behavior (Fig. 1a) needed to realize 500 °C circuit operation. The first fabrication strategy uses a shallow self-align nitrogen implant (Figure 1b) along the device's top surface but not below the gate combined with a high-dose phosphorous implant directly below the source and drain contacts. For the second fabrication strategy (Figure 1c), the high-dose phosphorous implants extended from below the contacts all the way up to the gate edges. Simulations guided gate length reductions without significant degradation in the turn-off performance. In total 12 SiC JFET variants implementing using the different fabrication strategies, gate lengths, and n-channel epilayer thickness were implemented in our simulation framework implemented in COMSOL. Since the COMSOL database does not have the material properties for 4H-SiC, these parameters were taken from the literature and implemented in COMSOL. The empirical models [2] for incomplete ionization, Auger recombination, low field mobility, and Shockley-Read-Hall recombination were implemented to account for material-specific device behavior.

4H-SiC JFET↗

Neural interface methods and apparatus to provide artificial sensory capabilities to a subject

Embodiments of neural interfaces according to the present invention comprise sensor modules for sensing environmental attributes beyond the natural sensory capability of a subject, and communicating the attributes wirelessly to an external (ex-vivo) portable module attached to the subject. The ex-vivo module encodes and communicates the attributes via a transcutaneous inductively coupled link to an internal (in-vivo) module implanted within the subject. The in-vivo module converts the attribute information into electrical neural stimuli that are delivered to a peripheral nerve bundle within the subject, via an implanted electrode. Methods and apparatus according to the invention incorporate implantable batteries to power the in-vivo module allowing for transcutaneous bidirectional communication of low voltage (e.g. on the order of 5 volts) encoded signals as stimuli commands and neural responses, in a robust, low-error rate, communication channel with minimal effects to the subjects' skin.

Buerger, Stephen P.↗

Wireless optofluidic systems for programmable in vivo pharmacology and optogenetics

Provided are implantable, injectable and/or surface mounted biomedical devices and related methods for interfacing with a target tissue. The devices have a substrate, one or more microfluidic channels embedded in or supported by the substrate and a fluid actuator in operational communication with one or more reservoirs and responsive to a wireless control signal. The components of the device are specially configured and packaged to be ultra-thin and mechanically compliant. In some embodiments, the devices are self-powered and fully implantable. The devices can be shaped to provide injection in a minimally invasive manner, thereby avoiding unnecessary tissue damage and providing a platform for long-term implantation for interfacing with biological tissue.

Rogers, John A.↗

Spatially Enhanced Electrostatic Doping in Graphene Realized via Heterointerfacial Precipitated Metals

Forming heavily-doped regions in 2D materials, like graphene, is a steppingstone to the design of emergent devices and heterostructures. Here, a selective-area approach is presented to tune the work-function and carrier density in monolayer graphene by spatially synthesizing sub-monolayer gallium beneath the 2D-solid. The localized metallic gallium is formed via precipitation from an underlying diamond-like carbon (DLC) film that is spatially implanted with gallium-ions. By controlling the interfacial precipitation process with annealing temperature, spatially precise ambipolar tuning of the graphene work-function is achieved, and the tunning effect preserved upon cooling to ambient conditions. Consequently, charge carrier densities from ≈1.8 × 10 10 cm -2 (hole-doped) to ≈7 × 10 13 cm -2 (electron-doped) are realized, confirmed by in situ and ex situ measurements. The theoretical studies corroborated the role of gallium at the heterointerface on charge transfer and electrostatic doping of the graphene overlayer. Specifically, sub-monolayer gallium facilitates heavy n-doping in graphene. Extending this doping strategy to other implantable elements in DLC provides a new means of exploring the physics and chemistry of highly-doped 2D materials.

36 MATERIALS SCIENCE↗

Simulation of Endovascular Aortic Repair Using 3D Printed Abdominal Aortic Aneurysm Model and Fluid Pump

Background: Abdominal aortic aneurysm (AAA) models can be manufactured with 3D printing technology. This study describes detailed methodology and validation of endovascular aortic repair (EVAR) simulation using 3D printed AAA model connected to hemodynamic pump. Method: The AAA model was printed with Objet500 Connex3 (Stratasys, Eden Prairie, MN) and connected to BDC PD-0500 fluid pump (BDC Laboratories, Wheat Ridge, CO). EVAR procedure metrics were benchmarked in two expert implanters and compared to 20 vascular surgical trainees with different levels of EVAR experience (< 20 or ≥ 20 cases). All simulations were performed using commercially available stent grafts, guidewires, catheters, fluoroscopic guidance and digital subtraction angiography. Studied outcomes included ability to complete the procedure independently, time to deploy aortic component, ability to cannulate contralateral gate and complete the repair, and total fluoroscopy and procedure times. Results: A total of 22 EVAR simulation procedures were performed with mean procedure time of 37 ± 12 min. Experienced trainees had significantly lower total procedural time (32 ± 9 vs. 44 ± 6 min, P = 0.003) and fluoroscopic time (13 ± 5 vs. 23 ± 8 min, P = 0.005). All experienced trainees completed the procedure independently in < 45 min, compared to six (46%) of those with less EVAR experience (P = 0.016). Among less experienced trainees, only two (15%) completed the entire procedure independently (P < 0.001). Benchmark implanters performed significantly better than both trainee groups in nearly all EVAR metrics. Conclusion: EVAR simulation was feasible and simulated all procedural steps with high fidelity. This model may be applicable for assessment of technical competencies and standard endovascular skill acquisition within vascular surgery training curricula.

3D PRINTING↗

Emergent Magnetism with Continuous Control in the Ultrahigh-Conductivity Layered Oxide PdCoO 2

The current challenge to realizing continuously tunable magnetism lies in our inability to systematically change properties, such as valence, spin, and orbital degrees of freedom, as well as crystallographic geometry. Here, we demonstrate that ferromagnetism can be externally turned on with the application of low-energy helium implantation and can be subsequently erased and returned to the pristine state via annealing. We find that this high level of continuous control is made possible by targeting magnetic metastability in the ultrahigh-conductivity, nonmagnetic layered oxide PdCoO 2 where local lattice distortions generated by helium implantation induce the emergence of a net moment on the surrounding transition metal octahedral sites. These highly localized moments communicate through the itinerant metal states, which trigger the onset of percolated long-range ferromagnetism. The ability to continuously tune competing interactions enables tailoring precise magnetic and magnetotransport responses in an ultrahigh-conductivity film and will be critical to applications across spintronics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non-dilute helium-related defect interactions in the near-surface region of plasma-exposed tungsten

We report a systematic energetic analysis of helium-related defect interactions that mediate helium (He) segregation on surfaces of plasma-exposed tungsten at different levels of He ion implantation. We focus on high He fluences that increase the He content in the plasma-exposed material well beyond the dilute limit of He concentration and employ atomic configurations generated by large-scale molecular dynamics simulations of He-implanted tungsten. We perform systematic molecular statics computations of cluster– defect interaction energetics in the highly defect-rich near-surface region of plasma-exposed tungsten for small mobile helium clusters as a function of the cluster distance from the surface. In this region, mobile clusters are also subjected to the stress fields generated by defects such as helium bubbles and other clusters, which govern cluster–defect interactions in addition to the cluster–surface interaction. Based on systematic investigation of individual cluster–defect interactions, we develop a mathematical framework to describe the interaction energy landscapes consisting of elastic interaction potential perturbations to finite-width square-well potentials, where the potential well accounts for cluster trapping by the defect at close range and subsequent coalescence and the perturbation potential is parameterized according to elastic inclusion theory. Superposition of all the relevant interaction potentials provides a comprehensive description of the interaction energy landscape that would be experienced by a small mobile cluster along its migration path toward the plasma-exposed surface at high He fluence. Such descriptions are particularly important for developing atomistically-informed, hierarchical multi-scale models of helium cluster dynamics in plasma-facing materials.

36 MATERIALS SCIENCE↗

Identification and characterization of deep nitrogen acceptors in β-Ga 2 O 3 using defect spectroscopies

The ability to achieve highly resistive beta-phase gallium oxide (β-Ga 2 O 3 ) layers and substrates is critical for β-Ga 2 O 3 high voltage and RF devices. To date, the most common approach involves doping with iron (Fe), which generates a moderately deep acceptor-like defect state located at E C -0.8 eV in the β-Ga 2 O 3 bandgap. Recently, there has been growing interest in alternative acceptors, such as magnesium (Mg) and nitrogen (N), due to their predicted deeper energy levels, which could avoid inadvertent charge modulation during device operation. In this work, a systematic study that makes direct correlations between the introduction of N using ion implantation and the observation of a newly observed deep level at E C -2.9 eV detected by deep-level optical spectroscopy (DLOS) is presented. The concentration of this state displayed a monotonic dependence with N concentration over a range of implant conditions, as confirmed by secondary ion mass spectrometry (SIMS). With a near 1:1 match in absolute N and E C -2.9 eV trap concentrations from SIMS and DLOS, respectively, which also matched the measured removal of free electrons from capacitance-voltage studies, this indicates that N contributes a very efficiently incorporated compensating defect. Density functional theory calculations confirm the assignment of this state to be an N (0/-1) acceptor with a configuration of N occupying the oxygen site III [N O(III) ]. The near ideal efficiency for this state to compensate free electrons and its location toward the midgap region of the β-Ga 2 O 3 bandgap demonstrates the potential of N doping as a promising approach for producing semi-insulating β-Ga 2 O 3 .

36 MATERIALS SCIENCE↗

Evaluating the diffusion of Kr in UO 2 and ADOPT TM using time-of-flight elastic recoil detection analysis (ToF-erda)

A combination of 300 keV 84 Kr ion implantation and Time-of-Flight Elastic Recoil Detection Analysis is utilized to investigate the diffusion of Kr in UO 2 and ADOPT TM fuels. Composition depth-profiles on the nanometer scale were obtained, both for as-implanted samples and after annealing at 800°C for 1 hour. Observed drifts in the 84 Kr profiles could be associated with short-range diffusion mechanisms. The approach employed here provides the possibility to make direct comparisons with atomistic scale modelling data, and can be of service as a separate effect test in line with the Accelerated Fuel Qualification initiative.

ADOPT UO2↗

Comparative study of helium bubbles in a Ti-Ta alloy and a Ti/Ta nanocomposite

Here, we investigated the size, density, and distribution of helium (He) bubbles in a Ti-Ta single-phase alloy and a Ti/Ta dual-phase nanocomposite using transmission electron microscopy. The Ti/Ta nanocomposite was fabricated via phase separation during high-temperature annealing of the single-phase Ti-Ta alloy. He ion implantation in the Ti-Ta single-phase alloy leads to the formation of nano-scale He bubbles (~1.7 nm in size, ~2.6×10 5 /μm 3 in volumetric density). He bubbles were found to segregate to grain boundaries. Under identical implantation conditions, numerous He bubbles also formed in the Ti/Ta nanocomposite. Closer inspection revealed that He bubbles in the Ti-rich phase are smaller and of higher volumetric density (~1.2 nm, ~8.4×10 5 /μm 3 ) than those in the Tarich phase (~3 nm, ~1.8×10 5 /μm 3 ) and the single-phase alloy. He bubbles were also observed to decorate phase boundaries, but they were generally smaller than those on grain boundaries. These results suggest that Ti/Ta phase boundaries are less conducive to the growth of large He bubbles than grain boundaries in the Ti-Ta single phase alloy.

36 MATERIALS SCIENCE↗

Using block-copolymer nanolithography as a tool to sensitively evaluate variation in chemical dry etching rates of semiconductor materials with sub-5 nm resolution

Ion implantation is a robust and established method to customize the electronic properties of Si. However, fabricating doped, ultrafine semiconductor nanostructures can be challenging. Ion implantation has well-established effects on the dry etch rates of Si, which becomes increasingly consequential as the target dimension shrinks below a few tens of nanometers. While dry etching arrays of block copolymer-templated nanoscale holes (pitch = 37.5 nm, diameter ~25 nm) into p-type, n-type, and undoped Si, we observed that the lateral etch rate was notably larger for the n-type regions than p-type or undoped regions. By doing image analyses on high resolution electron micrographs of the nanostructured hole arrays, we were able to extract the porosity and average radii of the holes with subnanometer sensitivity and compare the relative etch rates between different doping conditions. We found that degenerately doped n-type silicon consistently etches between approximately 17% and 27% faster in the lateral direction than p-type Si, resulting in significantly larger porosity and, consequently, less mechanical stability. Here, we demonstrate that top-down dimensional analysis of a densely packed porous nanostructure is a robust method for assessing extremely small differences in the lateral, chemical etch rate of doped Si to a degree of sensitivity that was previously unachievable. The minute, dense-packed nature of block copolymer self-assembled nanostructures is shown to be ideal for this application. This proposed method could be useful for designing fabrication processes for heterogeneous nanostructures, as slight dry etch rate variations that may be within process tolerance at the micrometer-scale appear to have nontrivial consequences at the nanometer scale.

42 ENGINEERING↗

Various Applications of Precision Low-Energy Nuclear Electron Spectrometry in the KATRIN Tritium Neutrino Project

The energy scale of the main spectrometer in the KATRIN tritium project is required to remain stable within ±60 meV at an electron energy of 18.6 keV for two months in order to reach the intended sensitivity of 0.2 eV for the rest mass of the electron antineutrino. A natural source of reference electrons with an energy of 17824.3 ± 0.5 eV based on K -conversion electrons of the 32-keV nuclear γ-transition in {sup 83m}Kr from the decay of parent {sup 83}Rb was developed for this purpose using precision low-energy nuclear electron spectrometry. The spectroscopic parameters of {sup 83m}Kr/{sup 83}Rb sources fabricated by ion implantation into polycrystalline platinum foils were significantly better than the parameters of vacuum-deposited sources. A large-scale study of the influence of the physicochemical environment of atoms of different radioisotopes in various matrices of vacuum-deposited and implanted radioactive sources on the energy of emitted conversion and Auger electrons and on the structure of the corresponding energy spectra was conducted in the process. The possibility of application of photoelectron sources with a metallic converter as sources of reference electrons for the KATRIN project was also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of helium on dispersoid evolution under self-ion irradiation in a dual-phase 12Cr oxide-dispersion-strengthened alloy

As one candidate alloy for future Generation IV and fusion reactors, a dual-phase 12Cr oxide-dispersion-strengthened (ODS) alloy was developed for high temperature strength and creep resistance and has shown good void swelling resistance under high damage self-ion irradiation at high temperature. However, the effect of helium and its combination with radiation damage on oxide dispersoid stability needs to be investigated. In this study, 120 keV energy helium was preloaded into specimens at doses of 1 × 10 15 and 1 × 10 16 ions/cm 2 at room temperature, and 3.5 MeV Fe self-ions were sequentially implanted to reach 100 peak displacement-per-atom at 475 °C. He implantation alone in the control sample did not affect the dispersoid morphology. After Fe ion irradiation, a dramatic increase in density of coherent oxide dispersoids was observed at low He dose, but no such increase was observed at high He dose. The study suggests that helium bubbles act as sinks for nucleation of coherent oxide dispersoids, but dispersoid growth may become difficult if too many sinks are introduced, suggesting that a critical mass of trapping is required for stable dispersoid growth.

36 MATERIALS SCIENCE↗

Activity in the ferret: oestradiol effects and circadian rhythms

The present study was conducted to determine whether oestradiol increases activity in the European ferret (Mustela furo), whether this effect is sexually dimorphic, and whether a 24-h rhythm is present in the ferret's daily activity. The activity of male and female adult, postpubertally gonadectomized ferrets was monitored while they were maintained singly on a 13:11 light-dark cycle, before and after implantation with oestradiol-17 beta. Gonadectomized male and female ferrets exhibited equal levels of activity, and neither sex exhibited a significant change in activity following oestradiol implantation. None of the ferrets exhibited a strong circadian rhythm, although weak 24-h rhythms and shorter harmonic rhythms were present. Golden hamsters (Mesocricetus auratus), monitored in an identical manner, exhibited strong circadian rhythms. It was concluded that oestradiol administration may not cause an increase in activity in the ferret, and that this species lacks a strong circadian activity rhythm.

Non-NASA Center↗

T wave alternans as a predictor of recurrent ventricular tachyarrhythmias in ICD recipients: prospective comparison with conventional risk markers

INTRODUCTION: The current standard for arrhythmic risk stratification is electrophysiologic (EP) testing, which, due to its invasive nature, is limited to patients already known to be at high risk. A number of noninvasive tests, such as determination of left ventricular ejection fraction (LVEF) or heart rate variability, have been evaluated as additional risk stratifiers. Microvolt T wave alternans (TWA) is a promising new risk marker. Prospective evaluation of noninvasive risk markers in low- or moderate-risk populations requires studies involving very large numbers of patients, and in such studies, documentation of the occurrence of ventricular tachyarrhythmias is difficult. In the present study, we identified a high-risk population, recipients of an implantable cardioverter defibrillator (ICD), and prospectively compared microvolt TWA with invasive EP testing and other risk markers with respect to their ability to predict recurrence of ventricular tachyarrhythmias as documented by ICD electrograms. METHODS AND RESULTS: Ninety-five patients with a history of ventricular tachyarrhythmias undergoing implantation of an ICD underwent EP testing, assessment of TWA, as well as determination of LVEF, baroreflex sensitivity, signal-averaged ECG, analysis of 24-hour Holter monitoring, and QT dispersion from the 12-lead surface ECG. The endpoint of the study was first appropriate ICD therapy for electrogram-documented ventricular fibrillation or tachycardia during follow-up. Kaplan-Meier survival analysis revealed that TWA (P < 0.006) and LVEF (P < 0.04) were the only significant univariate risk stratifiers. EP testing was not statistically significant (P < 0.2). Multivariate Cox regression analysis revealed that TWA was the only statistically significant independent risk factor. CONCLUSIONS: Measurement of microvolt TWA compared favorably with both invasive EP testing and other currently used noninvasive risk assessment methods in predicting recurrence of ventricular tachyarrhythmias in ICD recipients. This study suggests that TWA might also be a powerful tool for risk stratification in low- or moderate-risk patients, and needs to be prospectively evaluated in such populations.

Non-NASA Center↗