Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

A miniaturized neuroprosthesis suitable for implantation into the brain

This paper presents current research on a miniaturized neuroprosthesis suitable for implantation into the brain. The prosthesis is a heterogeneous integration of a 100-element microelectromechanical system (MEMS) electrode array, front-end complementary metal-oxide-semiconductor (CMOS) integrated circuit for neural signal preamplification, filtering, multiplexing and analog-to-digital conversion, and a second CMOS integrated circuit for wireless transmission of neural data and conditioning of wireless power. The prosthesis is intended for applications where neural signals are processed and decoded to permit the control of artificial or paralyzed limbs. This research, if successful, will allow implantation of the electronics into the brain, or subcutaneously on the skull, and eliminate all external signal and power wiring. The neuroprosthetic system design has strict size and power constraints with each of the front-end preamplifier channels fitting within the 400 x 400-microm pitch of the 100-element MEMS electrode array and power dissipation resulting in less than a 1 degree C temperature rise for the surrounding brain tissue. We describe the measured performance of initial micropower low-noise CMOS preamplifiers for the neuroprosthetic.

Action Potentials/physiology↗

Critical issues in the formation of quantum computer test structures by ion implantation

The formation of quantum computer test structures in silicon by ion implantation enables the characterization of spin readout mechanisms with ensembles of dopant atoms and the development of single atom devices. We briefly review recent results in the characterization of spin dependent transport and single ion doping and then discuss the diffusion and segregation behaviour of phosphorus, antimony and bismuth ions from low fluence, low energy implantations as characterized through depth profiling by secondary ion mass spectrometry (SIMS). Both phosphorus and bismuth are found to segregate to the SiO2/Si interface during activation anneals, while antimony diffusion is found to be minimal. An effect of the ion charge state on the range of antimony ions, 121Sb25+, in SiO2/Si is also discussed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Influence of High-Energy Krypton Ion Implantation Temperature on Structure and Properties of Ni–Ti Alloy

The influence of the temperature of implantation of Ni–Ti shape memory alloy with {sub 84}Kr{sup 15+}ions at the energy E = 147 MeV on its structural-phase state is investigated. At the implantation temperatures 250 and 300°С, within the projective range Rp and out-range area the following processes and phenomena are observed: new formation of the martensitic В19'-phase, formation of nano-sized particles of the R-phase, increase in resistivity due to the formation of radiation-defect structures, strengthening of the alloy in the austenitic structural-phase state, and longer phase-transition temperature intervals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nonlinear Resonance Response of Porous Beam-Type Implants Corresponding to Various Morphology Shapes for Bone Tissue Engineering Applications

Having excellent biocompatibility and apatite mineralization as well as efficient mechanical properties makes bredigite as one of the most attractive bioceramics. A beam-type porous biological implant in a 3D-printed architecture is designed with micron pore size. The surface properties, morphology, and size of the composed powders are evaluated using Scherrer and Williamson-Hall equation. The effect of MNPs deposition into the bredigite bioceramics and correlation with temperature effect on roughness of the prepared bio-nanocomposite are also investigated for hyperthermia application potential. The composed powders are characterized by x-ray diffraction, and then scanning electron microscopy (SEM), differential scanning calorimetry, thermogravimetric analysis (weight change, TGA), and atomic force microscopy are utilized to evaluate the surface topography. The resonance response is the tendency of a bone scaffold to respond at prominent amplitude while the frequency of its oscillations is equal to the structure’s natural frequency of vibration. Therefore, based on the obtained mechanical properties via the experimental approach for the bio-nanocomposite material, an analytical solution based upon the multiple-timescale method is carried out to analyze the nonlinear primary resonance of a 3D-printed porous beam-type biological implant under uniform-distributed load. According to SEM observations, there are hard agglomerates in the bredigite-magnetite nanoparticles (Br-MNPs) bio-nanocomposite material with low weight fraction of MNPs. However, they are broken down by increasing the amount of MNPs. Also, it is displayed that for lower MNPs weight fraction, the height of jump phenomenon related to the nonlinear resonance response is maximum and minimum for, respectively, irregular and mesoporous shapes of morphology, but their associated forcing amplitudes related to the bifurcation points are minimum and maximum, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

In Vitro Degradation, Antibacterial Activity and Cytotoxicity of Mg-3Zn-xAg Nanocomposites Synthesized by Mechanical Alloying for Implant Applications

A class of biodegradable Mg-3Zn-xAg nanocomposites was presented in the present study with the assessments for implant application. The evaluations included the effects of increasing the Ag content from 0.5 to 3 wt.% on the corrosion behavior, mechanical properties, antibacterial activity and cytotoxicity of Mg-3Zn-xAg nanocomposite. Microstructural analysis revealed the secondary phase intermetallic Mg{sub 54}Ag{sub 17} along the grain boundaries, with grain refinement as a result of increasing the Ag concentration. 0.5 wt.% Ag results in increasing the compressive strength and elongation; however, further addition decreases the compressive strength. The nanocomposite samples were verified for the improved antimicrobial activity by utilizing both E. coli and S. aureus bacteria, the growth of which was suppressed around all Ag-containing nanocomposites, whereas bacterial proliferations were detected around the Mg-3Zn nanocomposite. The escalating levels of Ag in the nanocomposite resulted in the elevated antimicrobial effect. Cell adhesion and proliferation were not significantly influenced by the inclusion of 0.5-1 wt% Ag into Mg-3Zn nanocomposite; however, cell adhesion and proliferation were lower on the surfaces of the nanocomposite containing 2-3 wt.% Ag counterparts. According to the mechanical, corrosion and biological assessments in the current research, it can be concluded that the nanocomposite containing 0.5 wt.% Ag can be properly applied as an orthopedic implant biomaterial.

36 MATERIALS SCIENCE↗

High-Dose-Rate Brachytherapy of a Single Implant With Two Fractions Combined With External Beam Radiotherapy for Hormone-Naive Prostate Cancer

Purpose: To evaluate the preliminary outcomes of high-dose-rate (HDR) brachytherapy of a single implant with two fractions and external beam radiotherapy (EBRT) for hormone-naive prostate cancer. Methods and Materials: Between March 2000 and Sept 2003, a total of 53 patients with tumor Stage T1c-T3b N0 M0 prostate cancer were treated with HDR brachytherapy boost doses (7.5 Gy/fraction) and 50-Gy EBRT during a 5.5-week period. Median follow-up was 61 months. Patients were divided into groups with localized (T1c-T2b) and advanced disease (T3a-T3b). We used the American Society for Therapeutic Radiology and Oncology (ASTRO) definition for biochemical failure. According to recommendations of the Radiation Therapy Oncology Group-ASTRO Phoenix Consensus Conference, biochemical failure-free control rates (BF-FCRs) at 3 years were investigated as 2 years short of the median follow-up. Results: Between April 2000 and Sept 2007, Common Terminology Criteria for Adverse Events Version 2.0 late Grade 2 genitourinary and gastrointestinal toxicity rates were 0% and 3.8%, respectively. Erectile preservation was 25% at 5 years. Overall survival was 88.1% and cause-specific survival was 100%. At 3 years, ASTRO BF-FCRs of the localized and advanced groups were 100% and 42%, respectively (p = 0.001). Conclusions: The HDR brachytherapy of a single implant with two fractions plus EBRT is effective in treating patients with localized hormone-naive prostate cancer, with the least genitourinary and gastrointestinal toxicities; however, longer median BF-FCR follow-up is required to assess these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tolerance and Acceptance Results of a Palladium-103 Permanent Breast Seed Implant Phase I/II Study

Purpose: To test, in a prospective Phase I/II trial, a partial breast irradiation technique using a {sup 103}Pd permanent breast seed implant (PBSI) realized in a single 1-h procedure under sedation and local freezing. Methods and Materials: Eligible patients had infiltrating ductal carcinoma {<=}3 cm in diameter, surgical margin {>=}2 mm, no extensive intraductal component, no lymphovascular invasion, and negative lymph nodes. Patients received a permanent seed implant, and a minimal peripheral dose of 90 Gy was prescribed to the clinical target volume, with a margin of 1.5 cm. Results: From May 2004 to April 2007, 67 patients received the PBSI treatment. The procedure was well tolerated, with 17% of patients having significant pain after the procedure. Only 1 patient (1.5%) had an acute skin reaction (Grade 3 according to the National Cancer Institute Common Toxicity Criteria). The rates of acute moist desquamation, erythema, and indurations were 10.4%, 42%, and 27%, respectively. At 1 year the rate of Grade 1 telangiectasia was 14%. The rate of skin reaction decreased from 65% to 28% when skin received less than the 85% isodose. According to a Radiation Therapy Oncology Group questionnaire, 80-90% of patients were very satisfied with their treatment, and the remainder were satisfied. One patient (1.5%) developed an abscess, which resolved after the use of antibiotics. There was no recurrence after a median follow-up of 32 months (range, 11-49 months). Conclusions: The feasibility, safety, and tolerability of PBSI compares favorably with that of external beam and other partial breast irradiation techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment

Purpose: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. Methods and Materials: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. Results: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 {+-} 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means ({mu}eff) +/- systematic ({Sigma}eff) intrafraction motion ({mu}{sub eff} {+-} {Sigma}{sub eff}) was 0.9 {+-} 1.1 mm and 0.6 {+-} 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion ({sigma}{sub eff}) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). Conclusion: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Report on the Clinical Outcomes of Permanent Breast Seed Implant for Early-Stage Breast Cancers

Purpose: Permanent breast seed implant is an accelerated partial breast irradiation technique realizing the insertion of {sup 103}Pd seeds in the seroma after lumpectomy. We report the 5-year efficacy and tolerance for a cohort, pooling patients from 3 clinical trials. Methods and Materials: The trials accrued postmenopausal patients with infiltrating ductal carcinoma or ductal carcinoma in situ ≤3 cm and clear surgical margins, who were node negative, and had a planning target volume <120 cm{sup 3}. The outcomes included overall and disease-free survival and local and contralateral recurrence at 5 years. The true local recurrence rate was compared using 2-tailed paired t tests for estimates calculated using the Tufts University ipsilateral breast tumor recurrence and Memorial Sloan Kettering ductal carcinoma in situ nomograms. Results: The cohort included 134 patients, and the observed local recurrence rate at a median follow-up period of 63 months was 1.2% ± 1.2%, similar to the estimate for whole breast irradiation (P=.23), significantly better than for surgery alone (relative risk 0.27; P<.001), and significantly lower than contralateral recurrence (relative risk 0.33; P<.001). The 5-year overall survival rate was 97.4% ± 1.9%, and the disease-free survival rate was 96.4% ± 2.1%. At 2 months, 42% of the patients had erythema, 20% induration, and 16% moist desquamation. The rate of mainly grade 1 telangiectasia was 22.4% at 2 years and 24% at 5 years. The rate of asymptomatic induration was 23% at 2 years and 40% at 5 years. Conclusions: The 5-year data suggest that permanent breast seed implantation is a safe accelerated partial breast irradiation option after lumpectomy for early-stage breast cancer with a tolerance profile similar to that of whole breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation induced hardening of beryllium during low temperature He implantation

The effect of ion irradiation on evolution of microstructure and hardening of beryllium with different impurity levels was investigated using TEM and nanoindentation. High purity S-65 grade and less-pure S-200-F grade were implanted by helium ions at temperatures of 50°C and 200°C. 11 different energies were used, so as to create a quasi-homogeneous 3 µm irradiated layer with average radiation damage of 0.1 dpa and average He content of 2000 appm.Nanoindentation experiments demonstrated that before irradiation, the S-200-F and S-65 grades have an average hardness of 3.7$\pm$0.8 GPa and 3.4$\pm$0.8 GPa correspondently. After implantation the hardness of both grades increased by about 60% for the 200°C irradiation and 100% for the 50°C irradiation. The crystallographic analysis of indented grains demonstrated that in the as-received materials the hardness is about 2.5 times higher when the indentation direction is close to the [0001] c-axis of beryllium compared to indentation perpendicular to [0001]. Hardness anisotropy significantly decreased after irradiation: the “soft orientation” was most sensitive to irradiation-induced hardening, with hardness increasing by about 140% after irradiation at 50°C and 100% after irradiation at 200°C, compared to about 15 - 20% for the “hard” orientation at both irradiation temperatures. The higher purity grade had smaller increase of the “soft orientation” hardness: 2.5$\pm$0.3 GPa for the S-65 and 2.9$\pm$0.2 GPa for the S-200-F.At both temperatures in both grades, under TEM investigation the radiation damage appears as “black dots” which are likely to be small dislocation loops with the number density of ~ 10 22 m -3 . No bubbles were observed by TEM inside grains and at grain boundaries. Analysis of the possible hardening contribution demonstrated that the observed “black dots” could be responsible for up to half of the measured hardening, while the rest of the hardening should originate from helium bubbles with the size below the TEM resolution (at or below 1.5 nm).

36 MATERIALS SCIENCE↗

Helium-implantation-induced lattice strains and defects in tungsten probed by X-ray micro-diffraction

Tungsten is the main candidate material for plasma-facing armour components in future fusion reactors. Bombardment with energetic fusion neutrons causes collision cascade damage and defect formation. Interaction of defects with helium, produced by transmutation and injected from the plasma, modifies defect retention and behaviour. Here we investigate the residual lattice strains caused by different doses of helium-ion-implantation into tungsten and tungsten-rhenium alloys. Energy and depth-resolved synchrotron X-ray micro-diffraction uniquely permits the measurement of lattice strain with sub-micron 3D spatial resolution and ~10 -4 strain sensitivity. Increase of helium dose from 300 appm to 3000 appm increases volumetric strain by only ~2.4 times, indicating that defect retention per injected helium is ~3 times higher at low helium doses. This suggests defect retention is not a simple function of implanted helium dose, but strongly depends on material composition and presence of impurities. Conversely, analysis of W-1 wt% Re alloy samples and of different crystal orientations shows that both the presence of rhenium, and crystal orientation, have a comparatively small effect on defect retention. These insights are key for the design of armour components in future reactors where it will be essential to account for irradiation-induced dimensional change when predicting component lifetime and performance.

36 MATERIALS SCIENCE↗

Effect of brachytherapy technique and patient characteristics on cervical cancer implant dosimetry

Our purpose was to evaluate the relationship between brachytherapy technique and patient characteristics on dose to organs-at-risk (OARs) in patients undergoing high dose rate (HDR) brachytherapy for cervical cancer. From 1998 to 2008, 31 patients with cervical cancer with full dosimetric data were identified who received definitive external-beam radiation and HDR brachytherapy with tandem and ovoid applicators. Doses were recorded at point A, the International Commission on Radiation Units and Measurements (ICRU)-38 rectal point, the ICRU-38 bladder point, the vaginal surface, and the pelvic sidewall. Generalized estimating equations were used to determine the significance of changes in OAR to point A dose ratios with differences in brachytherapy technique or patient characteristics. Patients underwent a median of 5 brachytherapy procedures (range, 3 to 5), with a total of 179 procedures for 31 patients. For all brachytherapy treatments, the average ratios between the doses for the rectal, bladder, vaginal surface, and pelvic sidewall reference points to those at point A were 0.49, 0.59, 1.15, and 0.17, respectively. In general, decreased OAR dose was associated with a lower stage, younger age, increased ovoid size, increased tandem length, and earlier implant number. Increased tandem curvature significantly increased bladder dose and decreased rectal dose. Intravenous anesthesia usage was not correlated with improved dosimetry. This study allowed identification of patient and procedure characteristics influencing OAR dosing. Although the advent of 3-dimensional (3D) image-guided brachytherapy will bring new advances in treatment optimization, the actual technique involved at the time of the brachytherapy implant procedure will remain important.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5 mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78 Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D{sub 90} of 34 Gy in 8.5 Gy per fraction, and 145 Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2 Gy per fraction, EQD{sub 2}) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The D{sub mean} (EQD{sub 2}) of rectum decreased 22.36 Gy in HDR and 17.01 Gy in LDR from 30.24 Gy in VMAT, respectively. The D{sub mean} (EQD{sub 2}) of bladder decreased 6.91 Gy in HDR and 2.53 Gy in LDR from 13.46 Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD{sub 2}) was 80.26, 70.23, and 104.91 Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Segmented YSO scintillation detectors as a new β -implant detection tool for decay spectroscopy in fragmentation facilities

A newly developed segmented YSO scintillator detector was implemented for the first time at the RI-beam Factory at RIKEN Nishina Center as an implantation-decay counter. The results from the experiment demonstrate that the detector is a viable alternative to conventional silicon-strip detectors with its good timing resolution and high detection efficiency for β particles. A Position-Sensitive Photo-Multiplier Tube (PSPMT) is coupled with a 48 × 48 segmented YSO crystal. To demonstrate its capabilities, a known short-lived isomer in 76 Ni and the β decay of 74 Co were measured by implanting those ions into the YSO detector. The half-lives and γ-rays observed in this work are consistent with the known values. The β -ray detection efficiency is more than 80 % for the decay of 74 Co.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A fitting algorithm for optimizing ion implantation energies and fluences

In this work we describe a method to automatically generate an ion implantation recipe, a set of energies and fluences, to produce a desired defect density profile in a solid using the fewest required energies. We simulate defect density profiles for a range of ion energies, fit them with an appropriate function, and interpolate to yield defect density profiles at arbitrary ion energies. Given Ν energies, we then optimize a set of Ν energy-fluence pairs to match a given target defect density profile. Finally, we find the minimum Ν such that the error between the target defect density profile and the defect density profile generated by the Ν energy-fluence pairs is less than a given threshold. Inspired by quantum sensing applications with nitrogen-vacancy centers in diamond, we apply our technique to calculate optimal ion implantation recipes to create uniform-density 1 μm surface layers of 15 N or vacancies (using 4 He).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Controllable Formation of Threefold-Coordinated Oxygen in Graphene by Low-Energy Ion Implantation

The atomically precise engineering of impurities in graphene and the understanding of their structural and carrier-dependent electronic properties at the nanoscale are crucial for advancing graphene-based nanoelectronics, catalysis, and energy technologies. Here, we demonstrate controllable incorporation of the elusive 3-fold-coordinated O substitutions into graphene using low-energy O + ion implantation under ultrahigh-vacuum conditions. By combining high-resolution scanning tunneling microscopy and spectroscopy (STM/S), bond-resolved noncontact atomic force microscopy techniques, and density functional theory (DFT) calculations, we resolve both the structural and electronic properties of the O-related defects. The STM/S measurements, corroborated by DFT calculations, uncover a characteristic impurity state that is energetically pinned to the Dirac point across different charge-carrier doping regimes. Molecular dynamics simulations further reveal the distribution of implantation-induced configurations and identify the formation of 3-fold-coordinated O dopants. Furthermore, this work provides a viable route to incorporate 3-fold-coordinated O dopants and opens new opportunities for controlled defect engineering in graphene.

3-fold-coordinated oxygen↗

Ion trajectories in plasma ion implantation of slender cylindrical bores using a small inner end source

Plasma immersion ion implantation (PIII) into slender cylindrical bores with higher efficiency is described in this letter. The use of an inner end plasma source excited by a radio-frequency hollow cathode is investigated theoretically and experimentally. The end source that is covered by a small grounded shielding electrode to ensure steady discharge enables continuous delivery of the required plasmas, and the potential difference in the tube increases the ion impact energy. Particle-in-cell simulation demonstrates that the ion trajectories are complex due to the special electric field configuration that is composed of three regions characterized by ion acceleration, no electric field, and ion deceleration. The end source structure with the open shielding electrode is insufficient to achieve high ion energy, although it is effective in maintaining a steady discharge in the source. Hence, a shielding electrode with a protruding electrode structure is required to conduct high energy PIII; a cylindrical bore with an inner diameter of 20 mm is successfully implanted.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Reduction of TED in Ion Implanted Silicon

The leading challenge in the continued scaling of junctions made by ion implantation and annealing is the control of the undesired transient enhanced diffusion (TED) effect. Spike annealing has been used as a means to reduce this effect and has proven successful in previous nodes. The peak temperature in this process is typically 1050 deg. C and the time spent within 50 deg. C of the peak is of the order of 1.5 seconds. As technology advances along the future scaling roadmap, further reduction or elimination of the enhanced diffusion effect is necessary. We have shown that raising the peak temperature to 1175 deg. C or more and reduction of the anneal time at peak temperature to less than a millisecond is effective in eliminating enhanced diffusion. We show that it is possible to employ a sequence of millisecond anneal followed by spike anneal to obtain profiles that do not exhibit gradient degradation at the junction and have junction depth and sheet resistance appropriate to the needs of future technology nodes. We have implemented millisecond annealing using a carbon dioxide laser to support high-volume manufacturing of 65 nm microprocessors and system-on-chip products. We further show how the use of molecular ion implantation to produce amorphousness followed by laser annealing to produce solid phase epitaxial regrowth results in junctions that meet the shallow depth and abruptness requirements of the 32 nm node.

36 MATERIALS SCIENCE↗