Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Open charm hadroproduction and the charm content of the proton

We advocate charmed-hadron inclusive hadroproduction as a laboratory to probe intrinsic charm (IC) inside the colliding hadrons. Working at next-to-leading order in the general-mass variable-flavor-number scheme endowed with nonperturbative fragmentation functions recently extracted from a global fit to e{sup +}e{sup -} annihilation data from KEKB, CESR, and LEP1, we first assess the sensitivity of Tevatron data of D{sup 0}, D{sup +}, and D*{sup +} inclusive production to the IC parametrizations provided by Pumplin et al. We then argue that similar data from pp collisions at RHIC would have the potential to discriminate between different IC models provided they reach out to sufficiently large values of transverse momentum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inverse Compton emission from millisecond pulsars in the Galactic bulge

Analyses of Fermi Gamma-Ray Space Telescope data have revealed a source of excess diffuse gamma rays towards the Galactic center that extends up to roughly ±20 degrees in latitude. The leading theory postulates that this GeV excess is the aggregate emission from a large number of faint millisecond pulsars (MSPs). The electrons and positrons (e ± ) injected by this population could produce detectable inverse-Compton (IC) emissions by up-scattering ambient photons to gamma-ray energies. In this work, we calculate such IC emissions using galprop. A triaxial three-dimensional model of the bulge stars obtained from a fit to infrared data is used as a tracer of the putative MSP population. This model is compared against one in which the MSPs are spatially distributed as a Navarro-Frenk-White squared profile. We show that the resulting spectra for both models are indistinguishable, but that their spatial morphologies have salient recognizable features. Furthermore, the IC component above ~TeV energies carries information on the spatial morphology of the injected e ± . Such differences could potentially be used by future high-energy gamma-ray detectors such as the Cherenkov Telescope Array to provide a viable multiwavelength handle for the MSP origin of the GeV excess.

79 ASTRONOMY AND ASTROPHYSICS↗

Topology Studies of Hydrodynamics Using Two-Particle Correlation Analysis

The effects of fluctuating initial conditions are studied in the context of relativistic heavy ion collisions where a rapidly evolving system is formed. Two-particle correlation analysis is applied to events generated with the NEXSPHERIO hydrodynamic code, starting with fluctuating nonsmooth initial conditions (IC). The results show that the nonsmoothness in the IC survives the hydroevolution and can be seen as topological features of the angular correlation function of the particles emerging from the evolving system. A long range correlation is observed in the longitudinal direction and in the azimuthal direction a double peak structure is observed in the opposite direction to the trigger particle. This analysis provides clear evidence that these are signatures of the combined effect of tubular structures present in the IC and the proceeding collective dynamics of the hot and dense medium.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Method for Assessment of Security-Relevant Settings in Anomaly-Based Intrusion Detection for Industrial Control Systems

Ensuring the integrity of Ethernet-based networks is a challenging and constantly evolving domain. This problem is exacerbated for those operational technology (OT) networks supporting industrial control systems (ICS) since much of that equipment was originally designed to be on a network that was isolated and generally considered free of malefactors. Increasing pressure to bridge these systems with traditional information technology (IT) networks has introduced a bevy of new threats. In response, both academia and industry have responded with security solutions tailored to ICS environments. Deploying these protection systems often involves several configuration choices. While some of these choices are clear (e.g., block/enable protocol X) others are far more subjective (e.g. alert threshold == 3.43). Further complicating the situation, while often similar to IT networks, OT networks have unique challenges and characteristics that make the task of protecting them simultaneously more difficult and straight forward.Extant solutions for quantifying the relative security of intrusion detection systems fail to effectively support the operators of said systems with understanding the impact of various configuration changes. Further, they assume that the attacks are static and not subject to manipulation or alteration in the face of defenses. In this paper, we present a threat-based method for quantifying the relative impact of various security settings for intrusion detection systems (IDSs) within ICS environments. This method provides operational staff with a clear understanding of the relative impact of their settings and assumes that the attacks levied against them are dynamic. The model is described in detail, we apply the model to a synthetic data set, and discuss the inferences that can be made and what types of decisions they could be used to support.

Gillen, Rob↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

An electric-circuit model on the inter-tape contact resistance and current sharing for REBCO cable and magnet applications

REBCO coated conductor has demonstrated high current capacity that can enable high-field magnets for high energy physics and fusion applications. However, quench protection is still one of the main challenges to be addressed for these applications. In addition, Ic and n value variations along the length of REBCO tapes exist in commercial production. The inter-tape contact resistance plays a key role to develop the self protection capability in cables and magnets by enabling current sharing and suppressing excessive eddy currents. Here we propose an electric-circuit model to describe the inter-tape contact resistance and its impact on the current sharing between REBCO tapes. We report the experiments on a 2-stacked tape REBCO cable with local Ic drop to validate the model. With the developed model, we study the upper limit of the contact resistance which allows current sharing between tapes. We also study the impact of variation in Ic and n values in tapes on the cable performance. Finally, our model is expected to provide useful insight into the current sharing and target values for inter-tape contact resistance in REBCO cables and magnets for various applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessing Anomaly-Based Intrusion Detection Configurations for Industrial Control Systems

To reduce cost and ease maintenance, industrial control systems (ICS) have adopted Ethernetbased interconnections that integrate operational technology (OT) systems with information technology (IT) networks. This integration has made these critical systems vulnerable to attack. Security solutions tailored to ICS environments are an active area of research. Anomalybased network intrusion detection systems are well-suited for these environments. Often these systems must be optimized for their specific environment. In prior work, we introduced a method for assessing the impact of various anomaly-based network IDS settings on security. This paper reviews the experimental outcomes when we applied our method to a full-scale ICS test bed using actual attacks. Our method provides new and valuable data to operators enabling more informed decisions about IDS configurations.

Gillen, Rob↗

Immune checkpoint analysis of T‐cell responses to pp65 and IE‐1 antigens in end‐stage lung diseases

Abstract Lung transplant (LTX) patients are at high risk of cytomegalovirus (CMV) infection, which is often associated with high mortality and morbidity. Reactivation of CMV causes cell injury due to the cytopathic effect of viral replication and triggering of T cell immunity. The aim of this study was to compare expression of immune checkpoints (ICs) (PD‐1, CTLA‐4, LAG‐3 and TIGIT) in CD4, CD8 and CD56 and activation markers CD137, CD154 and CD69 of end‐stage patients awaiting lung transplant. Eighteen pre‐LTX positive for anti‐CMV IgG titres and 18 healthy subjects were enrolled. IC and activation markers have been evaluated through flow cytometric analysis in HC and pre‐LTX patients. Reactive (QF+) and unreactive (QF−) patients were stratified according to QuantiFERON‐CMV assays. ICs' and activation markers' expression were determined before and after in vitro stimulation with pp‐65 and IE‐1 antigens. Lower expression of PD‐1 was observed in CD4 and CD8 cells of pre‐LTX patients than controls, whereas CTLA4 appeared upregulated in CD56 and CD8 cells. TIGIT is increased on the surface of CD4, CD8 and NK cells after peptide stimulation in QF‐negative patients and PD‐1 is only downregulated after stimulation in the QF‐positive patients. This study provides new evidence of immune dysregulation in patients with end‐stage lung disorders, particularly in relation to immune checkpoint cell biology. The change in QF+ mostly happens on cytotoxic cells NK and CD8, while the changes in QF− were observed in adaptive immune cells, including CD4 and CD8.

Bergantini, Laura↗

SU-E-T-96: Demonstration of a Consistent Method for Correcting Surface Dose Measurements Using Both Solid State and Ionization Chamber Detectors

Purpose: To compare the surface dose (SD) measured using a PTW 30-360 extrapolation chamber with different commonly used dosimeters (Ds): parallel plate ion chambers (ICs): RMI-449 (Attix), Capintec PS-033, PTW 30-329 (Markus) and Memorial; TLD chips (cTLD), TLD powder (pTLD), optically stimulated (OSLs), radiochromic (EXR2) and radiographic (EDR2) films, and to provide an intercomparison correction to Ds for each of them. Methods: Investigations were performed for a 6 MV x-ray beam (Varian Clinac 2300, 10x10 cm{sup 2} open field, SSD = 100 cm). The Ds were placed at the surface of the solid water phantom and at the reference depth dref=1.7cm. The measurements for cTLD, OSLs, EDR2 and EXR2 were corrected to SD using an extrapolation method (EM) indexed to the baseline PTW 30-360 measurements. A consistent use of the EM involved: 1) irradiation of three Ds stacked on top of each other on the surface of the phantom; 2) measurement of the relative dose value for each layer; and, 3) extrapolation of these values to zero thickness. An additional measurement was performed with externally exposed OSLs (eOSLs), that were rotated out of their protective housing. Results: All single Ds measurements overestimated the SD compared with the extrapolation chamber, except for Attix IC. The closest match to the true SD was measured with the Attix IC (− 0.1%), followed by pTLD (0.5%), Capintec (4.5%), Memorial (7.3%), Markus (10%), cTLD (11.8%), eOSL (12.8%), EXR2 (14%), EDR2 (14.8%) and OSL (26%). The EM method of correction for SD worked well for all Ds, except the unexposed OSLs. Conclusion: This EM cross calibration of solid state detectors with an extrapolation or Attix chamber can provide thickness corrections for cTLD, eOSLs, EXR2, and EDR2. Standard packaged OSLs were not found to be simply corrected.

60 APPLIED LIFE SCIENCES↗

SU-E-T-347: Validation of the Condensed History Algorithm of Geant4 Using the Fano Test

Purpose: To validate the condensed history algorithm and physics of the Geant4 Monte Carlo toolkit for simulations of ionization chambers (ICs). This study is the first step to validate Geant4 for calculations of photon beam quality correction factors under the presence of a strong magnetic field for magnetic resonance guided linac system applications. Methods: The electron transport and boundary crossing algorithms of Geant4 version 9.6.p02 were tested under Fano conditions using the Geant4 example/application FanoCavity. User-defined parameters of the condensed history and multiple scattering algorithms were investigated under Fano test conditions for three scattering models (physics lists): G4UrbanMscModel95 (PhysListEmStandard-option3), G4GoudsmitSaundersonMsc (PhysListEmStandard-GS), and G4WentzelVIModel/G4CoulombScattering (PhysListEmStandard-WVI). Simulations were conducted using monoenergetic photon beams, ranging from 0.5 to 7 MeV and emphasizing energies from 0.8 to 3 MeV. Results: The GS and WVI physics lists provided consistent Fano test results (within ±0.5%) for maximum step sizes under 0.01 mm at 1.25 MeV, with improved performance at 3 MeV (within ±0.25%). The option3 physics list provided consistent Fano test results (within ±0.5%) for maximum step sizes above 1 mm. Optimal parameters for the option3 physics list were 10 km maximum step size with default values for other user-defined parameters: 0.2 dRoverRange, 0.01 mm final range, 0.04 range factor, 2.5 geometrical factor, and 1 skin. Simulations using the option3 physics list were ∼70 – 100 times faster compared to GS and WVI under optimal parameters. Conclusion: This work indicated that the option3 physics list passes the Fano test within ±0.5% when using a maximum step size of 10 km for energies suitable for IC calculations in a 6 MV spectrum without extensive computational times. Optimal user-defined parameters using the option3 physics list will be used in future IC simulations to calculate beam quality correction factors under the presence of a magnetic field. Elekta-MD Anderson Research Agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-QI-13: Predictable Models for Radio-Sensitizing Agent Kinetics: Application to Stereotactic Synchrotron Radiation Therapy

Purpose: Iodine-enhanced radiotherapy is an innovative treatment combining the selective accumulation of an iodinated contrast agent in brain tumors with irradiations using monochromatic medium energy x-rays. The radiation dose enhancement depends on the time course of iodine in the tumors. A prolonged CT scanning (∼30 min) is required to follow-up iodine kinetics for recruited patients. This protocol could lead to substantial radiation dose to the patient. A novel method is proposed to reduce the acquisition time. Methods: 12 patients received an intravenous bolus of iodinated contrast agent, followed by a steady-state infusion to ensure stable intra-tumoral amounts of iodine during the treatment. Absolute iodine concentrations (IC) were derived from 40 multi-slice dynamic conventional CT images of the brain. The impulse response function (IRF) to the bolus was estimated using the adiabatic approximation of the Johnson and Wilson's model. The arterial input function (AIF) of the steady-state infusion was fitted with several models: Gamma, Gamma with recirculation and hybrid. Estimated IC were calculated by convolving the IRF with the modeled AIF and were compared to the measured data. Results: The gamma variate function was not relevant to model the AIF due to high differences with the measured AIF. The hybrid and the gamma with recirculation models provided differences below 8% during the whole acquisition time. The absolute difference between the measured and the estimated IC was lower than 0.5 mg/ml, which corresponds to 5% of dose enhancement error. Conclusion: The proposed method allows a good estimation of the iodine time course with reduced scanning delays (3 instead of 30 min) and dose to the patient. The results suggest that the dose errors may stay within the radiotherapy standards.

60 APPLIED LIFE SCIENCES↗

SU-E-P-24: Simplified EDW Profile Measurements Using Two Commonly Available Detector Arrays

Purpose: Enhanced dynamic wedge (EDW) profiles are needed as part of the commissioning of a treatment planning system. This work compares the acquisition of EDW profiles using a linear diode array (LDA) with two commonly used detector arrays available in the clinics, with the goal of identifying the simplest approach for these measurements. Methods: The measurements of EDW profiles were performed on a Varian TrueBeam linear accelerator for 6, 10, and 18 MV photon beams for all seven wedge angles at four depths. The measurements were done using the LDA 99 in Blue Phantom2 (IBA Dosimetry), and IC Profiler and MapCHECK2 (Sun Nuclear) in solid water phantoms. The water phantom was set up at 100 cm SSD, whereas the two other devices were set up at 75 cm due to the size limitations of the devices. The largest possible field size was used. The average and maximum percentage differences were examined within the central 90% of the field and in the penumbra. Results: Dose profiles measured with IC Profiler were in a good agreement with LDA 99 data. The average percentage difference within the field did not exceed 0.5% for all energies. MapCHECK2 measurements matched well with LDA 99 for 10 and 18 MV (within 0.3%) with discrepancies of up to 1.4% observed for the 6 MV beam. The maximum percentage differences for both devices in the penumbra exhibited larger variations than LDA 99 results due to differences in detector spacing and high dose gradient, as expected. Conclusion: Common linac QA devices such as IC Profiler or MapCHECK2 provide EDW beam profile data of reasonable accuracy as compared to measurements performed using a linear diode array in a water phantom, saving the expense and time involved in acquiring and setting up a LDA.

60 APPLIED LIFE SCIENCES↗

Practical dose point-based methods to characterize dose distribution in a stationary elliptical body phantom for a cone-beam C-arm CT system

Purpose: To propose new dose point measurement-based metrics to characterize the dose distributions and the mean dose from a single partial rotation of an automatic exposure control-enabled, C-arm-based, wide cone angle computed tomography system over a stationary, large, body-shaped phantom. Methods: A small 0.6 cm{sup 3} ion chamber (IC) was used to measure the radiation dose in an elliptical body-shaped phantom made of tissue-equivalent material. The IC was placed at 23 well-distributed holes in the central and peripheral regions of the phantom and dose was recorded for six acquisition protocols with different combinations of minimum kVp (109 and 125 kVp) and z-collimator aperture (full: 22.2 cm; medium: 14.0 cm; small: 8.4 cm). Monte Carlo (MC) simulations were carried out to generate complete 2D dose distributions in the central plane (z = 0). The MC model was validated at the 23 dose points against IC experimental data. The planar dose distributions were then estimated using subsets of the point dose measurements using two proposed methods: (1) the proximity-based weighting method (method 1) and (2) the dose point surface fitting method (method 2). Twenty-eight different dose point distributions with six different point number cases (4, 5, 6, 7, 14, and 23 dose points) were evaluated to determine the optimal number of dose points and their placement in the phantom. The performances of the methods were determined by comparing their results with those of the validated MC simulations. The performances of the methods in the presence of measurement uncertainties were evaluated. Results: The 5-, 6-, and 7-point cases had differences below 2%, ranging from 1.0% to 1.7% for both methods, which is a performance comparable to that of the methods with a relatively large number of points, i.e., the 14- and 23-point cases. However, with the 4-point case, the performances of the two methods decreased sharply. Among the 4-, 5-, 6-, and 7-point cases, the 7-point case (1.0% [±0.6%] difference) and the 6-point case (0.7% [±0.6%] difference) performed best for method 1 and method 2, respectively. Moreover, method 2 demonstrated high-fidelity surface reconstruction with as few as 5 points, showing pixelwise absolute differences of 3.80 mGy (±0.32 mGy). Although the performance was shown to be sensitive to the phantom displacement from the isocenter, the performance changed by less than 2% for shifts up to 2 cm in the x- and y-axes in the central phantom plane. Conclusions: With as few as five points, method 1 and method 2 were able to compute the mean dose with reasonable accuracy, demonstrating differences of 1.7% (±1.2%) and 1.3% (±1.0%), respectively. A larger number of points do not necessarily guarantee better performance of the methods; optimal choice of point placement is necessary. The performance of the methods is sensitive to the alignment of the center of the body phantom relative to the isocenter. In body applications where dose distributions are important, method 2 is a better choice than method 1, as it reconstructs the dose surface with high fidelity, using as few as five points.

60 APPLIED LIFE SCIENCES↗

Exploration of structure-activity relationships for the SARS-CoV-2 macrodomain from shape-based fragment linking and active learning

The macrodomain of severe acute respiratory syndrome coronavirus 2 nonstructural protein 3 is required for viral pathogenesis and is an emerging antiviral target. We previously performed an x-ray crystallography–based fragment screen and found submicromolar inhibitors by fragment linking. However, these compounds had poor membrane permeability and liabilities that complicated optimization. Here, we developed a shape-based virtual screening pipeline—FrankenROCS. We screened the Enamine high-throughput collection of 2.1 million compounds, selecting 39 compounds for testing, with the most potent binding with a 130 μM median inhibitory concentration (IC 50 ). We then paired FrankenROCS with an active learning algorithm (Thompson sampling) to efficiently search the Enamine REAL database of 22 billion molecules, testing 32 compounds with the most potent binding with a 220 μM IC 50 . Further optimization led to analogs with IC 50 values better than 10 μM. This lead series has improved membrane permeability and is poised for optimization. FrankenROCS is a scalable method for fragment linking to exploit synthesis-on-demand libraries.

Science & Technology - Other Topics↗

Reliability of diagnostic methods based on low-frequency noise analysis

Various methods for separating an integrated circuit (IC) batch were considered using noise parameters for the purpose of determining their reliability. The existing methods for screening semiconductor products using low-frequency (LF) noise were tested on transistors, as well as both digital and analog ICs, and showed good results. Selection criteria for semiconductor products were determined based on the statistics of a representative sample; however, their reliability was not estimated. The calculation of the correlation coefficient of determined LF noise parameters and reference reliability testing results was taken as the basis of the determination of reliability of diagnostic methods. For the experiment, KR142EN5A ICs made by bipolar technology were selected, which represent three-pin stabilizers with a fixed output voltage from 5 V and are used in many radio-electronic devices.

36 MATERIALS SCIENCE↗

Two-dimensional incommensurate magnetic fluctuations in Sr2(Ru0.99Ti0.01)O4

We investigate the imaginary part of the wave vector dependent dynamic spin susceptibility in Sr2(Ru0:99Ti0:01)O4 as a function of temperature using neutron scattering. At T = 5 K, two-dimensional incommensurate (IC) magnetic fluctuations are clearly observed around Qc = (0:3; 0:3;L) up to approximately 60 meV energy transfer. We find that the IC excitations disperse to ridges around the (; ) point. Below 50 K, the energy and temperature dependent excitations are well described by the phenomenological response function for a Fermi liquid system with a characteristic energy of 4.0(1) meV. Although the wave vector dependence of the IC magnetic fluctuations in Sr2(Ru0:99Ti0:01)O4 is similar to that in the Fermi liquid state of the parent compound, Sr2RuO4, the magnetic fluctuations are clearly suppressed by the Ti-doping.

Iida, Kazuki↗

Cyote-attack Chain Estimator

Attack Chain Estimator (ACE) Application Overview The Attack Chain Estimator (ACE) Application is a sophisticated tool designed for the ingestion, classification, sequencing, and enrichment of cybersecurity threat reports. This application leverages advanced machine learning models and extensive historical data to provide comprehensive insights into cyber threats, specifically targeting Industrial Control Systems (ICS). Purpose The primary functions of the ACE Application include: Ingestion of Cybersecurity Threat Reporting: Capable of ingesting text-based threat reports in markdown or text file format. Supports ingestion of structured data from other sources in STIX/JSON format. Classification of Report’s Text-Based Events: Utilizes a DeBERTa classifier, specifically trained on cybersecurity data, to map the events to MITRE ATT&CK for ICS Tactics and Techniques. Classification is performed using multiple Jupyter notebooks and machine learning workflows hosted as FastAPI microservices: regex_data deberta_base_35_train_hft_classifier_mlflow.ipynb hft_regex_classifier_mlflow.ipynb param_train_hft_classifier_mlflow.ipynb regex_tactic_tech.ipynb Ordering of Tactics, Techniques, and Observable Events: Sequences the identified tactics, techniques, and events to form a coherent attack chain. Enrichment with Historical Attack Chain Details: Enhances the attack chain with details from historical attacks using a Markov model developed from CyOTE Precursor Analysis Report data. The Markov model is available as a FastAPI endpoint for seamless integration. Enrichment with Adversary Emulation Capabilities Data: Integrates adversary emulation capabilities data using MITRE Caldera for OT adversary abilities UUIDs. Export of Output Files: Provides options to export the enriched attack chain in JSON or CSV formats. Routing of Output to Other Applications: Facilitates routing of output to various platforms and applications, including: Threat Intelligence Platforms COREII Scout for Threat Intelligence Analysis COREII Modeling and Simulation for Adversary Emulation Technical Description The ACE Application is an advanced cybersecurity tool designed to provide detailed threat analysis and sequence generation. It is built on a robust architecture that integrates natural language processing, machine learning, and historical data modeling. Key Components: Data Ingestion Module: Handles the input of threat reports and data from various formats, ensuring flexibility in data sources. Classification Engine: Employs DeBERTa-based classifiers hosted as FastAPI microservices to analyze and classify threat report events in accordance with the MITRE ATT&CK framework for ICS. Sequence Generator: Orders the classified events into a logical attack chain, providing clear insight into the sequence of tactics and techniques used in the threat. Enrichment Engine: Integrates historical data and adversary emulation capabilities to enhance the attack chain with valuable context and additional details. The historical data enrichment is powered by a Markov model, which is available as a FastAPI endpoint. Export and Routing Module: Facilitates the export of the enriched attack chain in multiple formats and routes the output to designated applications for further analysis or emulation.

Paul, Tony [Idaho National Laboratory (INL), Idaho↗

Soil Moisture Drought Monitoring and Forecasting Using Satellite and Climate Model Data over Southwestern China

In this paper, an experimental soil moisture drought monitoring and seasonal forecasting framework based on the Variable Infiltration Capacity model (VIC) over southwestern China (SW) is presented. Satellite precipitation data are used to force VIC for a near-real-time estimate of land surface hydrologic conditions. Initialized with satellite-aided monitoring (MONIT), the climate model (CFSv2)-based forecast (MONIT+CFSv2) and ensemble streamflow prediction (ESP)-based forecast (MONIT+ESP) are both performed. One dry season drought and one wet season drought are employed to test the ability of this framework in terms of real-time tracking and predicting the evolution of soil moisture (SM) drought, respectively. The results show that the skillful CFSv2 climate forecasts (CFs) are only found at the first month. The satellite-aided monitoring is able to provide a reasonable estimate of forecast initial conditions (ICs) in real-time mode. In the presented cases, MONIT+CFSv2 forecast exhibits comparable performance against the observation-based estimates for the first month, whereas the predictive skill largely drops beyond 1 month. Compared to MONIT+ESP, MONIT+CFSv2 ensembles give more skillful SM drought forecast during the dry season, as indicated by a smaller ensemble range, while the added value of MONIT+CFSv2 is marginal during the wet season. Furthermore, a quantitative attribution analysis of SM forecast uncertainty demonstrates that SM forecast skill is mostly controlled by ICs at the first month and that uncertainties in CFs have the largest contribution to SM forecast errors at longer lead times. This study highlights a value of this framework in generating near-real-time ICs and providing a reliable SM drought prediction with 1 month ahead, which may greatly benefit drought diagnosis, assessment, and early warning.

54 ENVIRONMENTAL SCIENCES↗