Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Hourly Load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Thermal Modeling and Correlation of the Space Environments Complex Vacuum Chamber and Cryoshroud

From Presentation: Formerly known as the Space Power Facility (SPF) Located at Plum Brook Station in Sandusky, OH -- Houses large-scale test facilities including the Space Simulation Vacuum Chamber -- Largest vacuum chamber in the world -- 100 ft diameter, 122 ft tall -- Cryoshroud operates between -250 °F and +140 °F -- To be used for Orion EM-1 thermal vacuum test -- Thermal Desktop model of vacuum chamber, cryoshroud, mechanical ground support equipment (MGSE) including fluid model of GN2 -- Primary uses: Predict MGSE temperatures; Predict heat load on GN2 system -- Includes 96 TD Temperature Measures that represent test thermocouples -- Steady state correlation with 3 tests: 2 hot; 1 cold -- Two ISTs performed with no MGSE inside the cryoshroud: Insulated test: operated at 170 °F for 37 hours; Uninsulated test: operated at 170 °F for 14 days -- Only cryoshroud thermocouples were installed

Thermal modeling↗

Quantifying Solar PV Variability at Multiple Timescales for Power Systems Studies: Preprint

Increasing penetration of solar photovoltaics (PV) has concerned power system operators about their ability to balance load and generation over multiple timescales and maintain acceptable frequency profile because of the variability and uncertainty associated with solar PV. This paper focuses on developing metrics to quantify solar PV variability at multiple temporal scales ranging from seconds to an hour to help power system operators and planners better understand and account for solar PV variability under high solar PV penetration. Fourier coefficients of solar irradiation spectrum and average size of solar irradiation ramps over a day are the two metrics that are used to quantity the variability. It is shown that by using the two metrics the days with highest and lowest solar irradiation variability can be identified, which is useful information for operations planning or long-term power system planning studies. The key findings of the paper are (i) single sensor-based variability quantification can significantly exaggerate the variability of a solar PV plant, particularly at seconds to 1-min temporal resolution, (ii) at 1-minute or lower temporal resolutions, single sensor-based variability quantification of an entire plant can be fairly accurate, with the accuracy increasing as the temporal resolution reduces from 1-minute to 1-hour, (iii) at each 1-minute and lower temporal resolutions, maximum solar irradiation ramps appear to be independent of the geographical location of the sensor, and (iv) significant reduction in solar PV plant variability over a region with multiple plants is possible at all temporal scales, but more high quality, high temporal resolution data is needed to quantify the reduction with high confidence.

photovoltaics↗

Laboratory Experiments Examining the Effect of Thermal and Mechanical Processes on Hydraulic Transmissivity Evolution

Using laboratory slide-hold-slide experiments, at temperatures from 22 to 200 degrees C, to examine effects of fracture reactivation and quasi-static loading on the evolution of fluid transport properties of simulated fractures in Westerly granite. At all temperatures, the in-plane hydraulic transmissivity consistently decays during hold periods resulting in an overall reduction in transmissivity. During the first three to fifteen hours of an experiment, transmissivity decreases rapidly due to the generation of wear products, development of a sliding surface, and compaction of the resulting gouge. Once the sliding surface has developed, the long-term transmissivity decay rate at 22 and 100 degrees C is significantly lower than the transmissivity decay rate during the initial 3-15 hours of the experiment. However, at 200 degrees C, the decay of hydraulic transmissivity remains high throughout the experiment. The long-term decay of hydraulic transmissivity can be fitted with a power law model with more rapid reduction of hydraulic transmissivity at higher temperature. Periods of sliding on the fracture surface result in transient increases in the transmissivity, due to shear dilation, as is expected for Coulomb materials. These transients are superimposed on the long-term decay. When sliding ceases and a new hold period commences, there is a rapid reduction in transmissivity and return to the long-term rate of transmissivity decay. The rate of decay of the transmissivity transients is inversely correlated with temperature, in contrast to the long-term decay and the expected behavior for processes like subcritical crack growth and indentation creep. The higher decay rates that are observed during the initial 3-15 hours of the tests and following sliding, are associated with times that the porosity of the gouge is expected to be high. The difference in decay rates suggests that when the gouge is driven far from equilibrium by active shearing, densification may be dominated by a different mechanism from long-term compaction.

15 GEOTHERMAL ENERGY↗

Summary of Previous Mechanical Test Data on ODS Alloys 14YWT and OFRAC up to 1000ºC

The Nanostructured Ferritic Alloys (NFA) 14YWT and OFRAC were developed for future fission and fusion nuclear energy reactors requiring high-temperature mechanical properties that are tolerant to extreme neutron irradiation environments. The NFA contain a high concentration of Ti-, Y- and O-enriched nanoclusters (NC) and ultra-fine grains to achieve high temperature strength and creep properties and high sink strength for trapping irradiation induced point defects to minimize hardening and swelling and transmutated He atoms to form intragranular nano-size bubbles that prevent formation of coarse bubbles on grain boundaries that cause embrittlement. The mechanical properties of 14YWT and OFRAC have been acquired from tensile and creep tests conducted in the past at Oak Ridge National Laboratory. The development of 14YWT started in 2000, resulting in the production of numerous heats. Tensile properties were obtained from eleven heats of 14YWT from room temperature to 800ºC. Tensile data for the SM10 heat of 14YWT was extended to 1,000ºC. Initial development of OFRAC occurred in 2016. Tensile tests conducted from room temperature to 800ºC revealed similar properties of OFRAC with those obtained from the newer generation of 14YWT heats. The creep properties of 14YWT-SM10 evaluated using constant stress tensile and load time-to-failure tests at 800ºC showed low minimum creep rates with stresses of 200 and 100 MPa. The single time-to-failure test of 14YWT-SM10 at 800ºC and 100 MPa was terminated after 20,357 hours with no specimen failure and a low creep strain of ~0.24 %. The creep properties of OFRAC determined from strain-rate jump tests at were similar those of 14YWT-SM10. The stress exponent for 14YWT and OFRAC at 800ºC are similar and are consistent with threshold stress behavior. Since both 14YWT and OFRAC are candidates for fuel cladding in future fast reactors, several fabrication studies were recently conducted and have successfully demonstrated that thin wall tubes can be fabricated from 14YWT and OFRAC by cold pilger rolling and high precision tube rolling. The high temperature mechanical properties and feasibility of fabricating thin wall tubes make 14YWT and OFRAC candidates for application as heat pipes in advanced micro-reactors. The purpose of this report is to summarize the previously obtained tensile and creep data at temperatures up to 1000ºC for NFA 14YWT and OFRAC that have been acquired over the past 20 years at ORNL.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Temperature Resin Matrix Composites for Aerospace Structures

Accomplishments and the outlook for graphite-polyimide composite structures are briefly outlined. Laminates, skin-stiffened and honeycomb sandwich panels, chopped fiber moldings, and structural components were fabricated with Celion/LARC-160 and Celion/PMR-15 composite materials. Interlaminar shear and flexure strength data obtained on as-fabricated specimens and specimens that were exposed for 125 hours at 589 K indicate that epoxy sized and polyimide sized Celion graphite fibers exhibit essentially the same behavior in a PMR-15 matrix composite. Analyses and tests of graphite-polyimide compression and shear panels indicate that utilization in moderately loaded applications offers the potential for achieving a 30 to 50 percent reduction in structural mass compared to conventional aluminum panels. Data on effects of moisture, temperature, thermal cycling, and shuttle fluids on mechanical properties indicate that both LARC-160 and PMR-15 are suitable matrix materials for a graphite-polyimide aft body flap. No technical road blocks to building a graphite-polyimide composite aft body flap are identified.

Davis, J. G., Jr.↗

In-flight structural dynamic characteristics of the XV-15 tilt rotor research aircraft

The XV-15 tilt rotor research aircraft has recently completed the contractor flight test program at the Bell Helicopter Textron Flight Research Center, Arlington, Texas. During these development and envelope expansion flights (60 flight hours, 140 flights), the aircraft has been tested up to a maximum true airspeed of 557 km/h (346 mph, 301 knts). Results of the structural characteristics obtained during this testing are presented. Included is a discussion concerning the rotor and airframe loads, natural frequency placements, airframe control system interaction, and wing-rotor-pylon aeroelastic stability. Measured data are compared with predicted values for many cases.

Bilger, J. M.↗

Ion thruster system (8-cm) cyclic endurance test

This report describes the qualification test of an Engineering-Model 5-mN-thrust 8-cm-diameter mercury ion thruster which is representative of the Ion Auxiliary Propulsion System (IAPS) thrusters. Two of these thrusters are scheduled for future flight test. The cyclic endurance test described herein was a ground-based test performed in a vacuum facility with a liquid-nitrogen-cooled cryo-surface and a frozen mercury target. The Power Electronics Unit, Beam Shield, Gimal, and Propellant Tank that were used with the thruster in the endurance test are also similar to those of the IAPS. The IAPS thruster that will undergo the longest beam-on-time during the actual space test will be subjected to 7,055 hours of beam-on-time and 2,557 cycles during the flight test. The endurance test was successfully concluded when the mercury in the IAPS Propellant Tank was consumed. At that time, 8,471 hours of beam-on-time and 599 cycles had been accumulated. Subsequent post-test-evaluation operations were performed (without breaking vacuum) which extended the test values to 652 cycles and 9,489 hours of beam-on-time. The Power Electronic Unit (PEU) and thruster were in the same vacuum chamber throughout the test. The PEU accumulated 10,268 hr of test time with high voltage applied to the operating thruster or dummy load.

Dulgeroff, C. R.↗

Hydrogen-oxygen proton-exchange membrane fuel cells and electrolyzers

Hydrogen-oxygen SPE fuel cells and SPE electrolyzers (products of Hamilton Standard) both use a Proton-Exchange Membrane (PEM) as the sole electrolyte. The SPE cells have demonstrated a ten year life capability under load conditions. Ultimate life of PEM fuel cells and electrolyzers is primarily related to the chemical stability of the membrane. For perfluorocarbon proton-exchange membranes an accurate measure of the membrane stability is the fluoride loss rate. Millions of cell hours have contributed to establishing a relationship between fluroride loss rates and average expected ultimate cell life. Several features were introduced into SPE fuel cells and SPE electrolyzers such that applications requiring greater than or equal to 100,000 hours of life can be considered. Equally important as the ultimate life is the voltage stability of hydrogen-oxygen fuel cells and electrolyzers. Here again the features of SPE fuel cells and SPE electrolyzers have shown a cell voltage stability in the order of 1 microvolt per hour. That level of stability were demonstrated for tens of thousands of hours in SPE fuel cells at up to 500 amps per square foot (ASF) current density. The SPE electrolyzers have demonstrated the same at 1000 ASF. Many future extraterrestrial applications for fuel cells require that they be self recharged. To translate the proven SPE cell life and stability into a highly reliable extraterrestrial electrical energy storage system, a simplification of supporting equipment is required. Static phase separation, static fluid transport and static thermal control will be most useful in producting required system reliability. Although some 200,000 SPE fuel cell hours were recorded in earth orbit with static fluid phase separation, no SPE electrolyzer has, as yet, operated in space.

Baldwin, R.↗

Room Temperature Characterization of a Magnetic Bearing for Turbomachinery

Open loop, experimental force and power measurements of a three-axis, radial, heteropolar magnetic bearing at room temperature for rotor speeds up to 20,000 RPM are presented in this paper. The bearing, NASA Glenn Research Center's and Texas A&M's third generation high temperature magnetic bearing, was designed to operate in a 1000 F (540 C) environment and was primarily optimized for maximum load capacity. The experimentally measured force produced by one C-core of this bearing was 630 lb. (2.8 kN) at 16 A, while a load of 650 lbs (2.89 kN) was predicted at 16 A using 1D circuit analysis. The maximum predicted radial load for one of the three axes is 1,440 lbs (6.41 kN) at room temperature. The maximum measured load of an axis was 1050 lbs. (4.73 kN). Results of test under rotating conditions showed that rotor speed has a negligible effect on the bearing's load capacity. A single C-core required approximately 70 W of power to generate 300 lb (1.34 kN) of magnetic force. The room temperature data presented was measured after three thermal cycles up to 1000 F (540 C), totaling six hours at elevated temperatures.

Montague, Gerald↗

Building Demand Flexibility: Grid Service Value of Future Market Entrants

The building sector is an important source of demand-side flexibility that is crucial for renewable energy integration in the future power systems. The grid service value of building flexibility, especially that which provides load shifting, has not been analyzed for the United States. We use a technology-agnostic approach based on detailed grid expansion and production cost modeling results to evaluate the capacity, energy, and ancillary service values of a marginal kilowatt-hour (kWh) of daily, shiftable building flexibility as a presumed market entrant in the 2030 U.S. power systems. We find the monthly mean of building flexibility has a range of 0-38 cents/kWh-day, depending on the original usage hour, month, region, building flexibility parameters, and grid scenario. The daily value consists of the highest-value hour each day across all the scenarios has a range of 0-620 cents/kWh-day. The results are provided in an open database for users to obtain the values of specific technologies based on what services can be provided, when, and in what quantities.

30 DIRECT ENERGY CONVERSION↗

Achieving high hydrogen productivities of 20 L/L-day via microbial electrolysis of corn stover fermentation products

Microbial electrolysis cells have the potential to generate renewable hydrogen from underused waste streams, however current devices have not reached very large productivity targets using real waste products at any scale. This study used a waste from fermented corn stover known as corn stover fermentation product to reach performance metrics that could be commercialized, if adequately scaled. Average current densities in MECs with mature biofilms reached 17.9 +/- 1.6 A/m 2 at an organic loading rate of 30 grams of chemical oxygen demand per liter of anode volume per day (g/L-day), reaching a maximum current density of 27.2 +/- 2.9 A/m 2 . Hydrogen productivities reached 20.2 +/- 2.0 L of H 2 per L anode volume per day (L/L-day). These represent the highest current densities and highest hydrogen productivities using a complex feedstock in a microbial electrolysis cell. Organic acids and sugars present in untreated substrate were converted at high percentages in MECs, with most above 90% conversion, at organic loading rates of 10, 20, and 30 g/L-day. The effect of periodic high liquid flow rates through the anode on performance was assessed. These tests, called pulsing, showed that hydrogen productivities and current densities increased most dramatically as flow was pulsed every hour at a baseline flow rate of 0.3 mL/min. These productivities show promise for high performance systems, if adequate scale up can be achieved.

09 BIOMASS FUELS↗

Photolysis Controls Atmospheric Budgets of Biogenic Secondary Organic Aerosol

Secondary organic aerosol (SOA) accounts for a large fraction of tropospheric particulate matter. While SOA production rates and mechanisms have been extensively investigated, loss pathways remain uncertain. Most large-scale chemistry and transport models account for mechanical deposition of SOA, but not chemical losses, such as photolysis. There is also a paucity of laboratory measurements of SOA photolysis, which limits how well photolytic losses can be modeled. Here we show, through a combined experimental and modeling approach, that photolytic loss of SOA mass significantly alters SOA budget predictions. Using environmental chamber experiments, we find that SOA produced from several biogenic volatile organic compounds (VOCs) undergoes photolysis-induced mass loss at rates between 0 and 2.2% ± 0.4% of nitrogen dioxide (NO 2 ) photolysis, equivalent to average atmospheric lifetimes as short as 10 hours. We incorporate our photolysis rates into a regional chemical transport model to test the sensitivity of predicted SOA mass concentrations to photolytic losses. The addition of photolysis at rates consistent with our experimental conditions causes a ~50% reduction in biogenic SOA loadings over the Amazon, indicating that photolysis exerts a substantial control over the atmospheric SOA lifetime, with a likely dependence upon SOA molecular composition and thus production mechanisms.

54 ENVIRONMENTAL SCIENCES↗

Heat engine requirements for advanced solar thermal power systems

Requirements and constraints are established for power conversion subsystems, including heat engine, alternator and auxiliaries, of dish concentrator solar thermal power systems. In order to be competitive with conventional power systems, it is argued that the heat engine should be of less than 40 kW rated output, in a subsystem with an efficiency of at least 40% at rated output and at least 37% at half power. An interval between major overhauls of 50,000 hours is also desirable, along with minor maintenance and lubrication not more than four times a year requiring no more than one man-hour each time, and optimal reliability. Also found to be important are the capability for hybrid operation using heat from a solar receiver, fuel-fired combustor or both simultaneously, operation at any attitude, stability to transients in input power and output loading, operation at ambient temperatures from -30 to 50 C, and compatibility with environmental and safety requirements. Cost targets include a price of $180/kWe, and operation, maintenance and replacement costs averaging $0.001/kWh for 30 years of operation.

Jaffe, L. D.↗

Microhardness and lattice parameter calibrations of the oxygen solid solutions of unalloyed alpha-titanium and Ti-6Al-2Sn-4Zr-2Mo

Standards were prepared for calibrating microanalyses of dissolved oxygen in unalloyed alpha-Ti and Ti-6Al-2Sn-4Zr-2Mo. Foils of both of these materials were homogenized for 120 hours in vacuum at 871 C following short exposures to the ambient atmosphere at 854 C that had partially oxidized the foils. The variation of Knoop microhardness with oxygen content was calibrated for both materials using 15-g and 5-g indentor loads. The unit-cell lattice parameters were calibrated for the unalloyed alpha-Ti. Example analyses demonstrate the usefulness of these calibrations and support an explanation of an anomaly in the lattice parameter variation. The results of the calibrations have been tabulated and summarized using predictive equations.

Wiedemann, K. E.↗

A study of the influence of the data acquisition system sampling rate on the accuracy of measured acceleration loads for transport aircraft

A research effort was initiated at National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC), to describe the relationship between the sampling rate and the accuracy of acceleration loads obtained from the data acquisition system of a transport aircraft. An accelerometer was sampled and digitized at a rate of 100 samples per second onboard a NASA Boeing 737 (B-737) flight research aircraft. Numerical techniques were used to reconstruct 2.5 hours of flight data into its original input waveform and then re-sample the waveform into rates of 4, 8, 16, and 32 samples per second. Peak-between-means counting technique and power spectral analysis were used to evaluate each sampling rate using the 32 samples per second data as the comparison. This paper presents the results from these methods and includes in appendix A, the peak-between-means counting results used in a general fatigue analysis for each of the sampling rates.

Whitehead, Julia H.↗

National Maglev initiative: California line electric utility power system requirements

The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

Save, Phil↗

Performance of an Electro-Hydrostatic Actuator on the F-18 Systems Research Aircraft

An electro-hydrostatic actuator was evaluated at NASA Dryden Flight Research Center, Edwards, California. The primary goal of testing this actuator system was the flight demonstration of power-by-wire technology on a primary flight control surface. The electro-hydrostatic actuator uses an electric motor to drive a hydraulic pump and relies on local hydraulics for force transmission. This actuator replaced the F-18 standard left aileron actuator on the F-18 Systems Research Aircraft and was evaluated throughout the Systems Research Aircraft flight envelope. As of July 24, 1997 the electro-hydrostatic actuator had accumulated 23.5 hours of flight time. This paper presents the electro-hydrostatic actuator system configuration and component description, ground and flight test plans, ground and flight test results, and lessons learned. This actuator performs as well as the standard actuator and has more load capability than required by aileron actuator specifications of McDonnell- Douglas Aircraft, St. Louis, Missouri. The electro-hydrostatic actuator system passed all of its ground tests with the exception of one power-off test during unloaded dynamic cycling.

Robert Navarro↗

Metrics for Flight Operations: Application to Europa Clipper Tour Selection

Objective measures are ubiquitous in the formulation, design and implementation of deep space missions. Tour durations, flyby altitudes, propellant budgets, power consumption, and other metrics are essential to developing and managing NASA missions. But beyond the simple metrics of cost and workforce, it has been difficult to identify objective, quantitative measures that assist in evaluating choices made during formulation or implementation phases in terms of their impact on flight operations. As part of the development of the Europa Clipper Mission system, a set of operations metrics have been defined along with the necessary design information and software tooling to calculate them. We have applied these methods and metrics to help assess the impact to the flight team on the six options for the Clipper Tour that are currently being vetted for selection in the fall of 2021. To generate these metrics, the Clipper MOS team first designed the set of essential processes by which flight operations will be conducted, using a standard approach and template to identify (among other aspects) timelines for each process, along with their time constraints (e.g., uplinks for sequence execution). Each of the resulting 50 processes is documented in a common format and concurred by stakeholders. Process timelines were converted into generic schedules and workforce-loaded using COTS scheduling software, based on the inputs of the process authors and domain experts. Custom code was generated to create an operations schedule for a specific portion of Clipper's prime mission, with instances of a given process scheduled based on specific timing rules (e.g., process X starts once per week on Thursdays) or relative to mission events (e.g., sequence generation process begins on a Monday, at least three weeks before each Europa closest approach). Over a 5-month period, and for each of six Clipper candidate tours, the result was a 20,000+ line, workforce-loaded schedule that documents all of the process-driven work effort at the level of individual roles, along with a significant portion of the level-of-effort work. Post-processing code calculated the absolute and relative number of work hours during a nominal 5 day / 40 hour work week, the work effort during 2nd and 3rd shift, as well as 1st shift on weekends. The resultant schedules and shift tables were used to generate objective measures that can be related to both human factors and to operational risk and showed that Clipper tours which utilize 6:1 resonant (21.25 day) orbits instead of 4:1 resonant (14.17 day) orbits during the first dozen or so Europa flybys are advantageous to flight operations. A similar approach can be extended to assist missions in more objective assessments of a number of mission issues and trades, including tour selection and spacecraft design for operability.

Sarrel, Marc↗