Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High Temperature Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Deriving Climate Change Signal from Hyperspectral Sounders Using Spectral Fingerprinting Method

Hyperspectral observations from satellite-based sensors provide high information content for the Earth’s atmospheric temperature, water vapor and trace gas vertical profiles. We have developed a radiometrically consistent spectral fingerprinting method to derive climate change signals from Aqua AIRS/AMSU and S-NPP CrIS/ATMS data. The climate variables include temperature and water vapor profiles, cloud, trace gases, and surface skin temperature. The radiative kernels obtained via a single field of view physical retrieval algorithm under all-sky conditions. A key component to this work is a Principal Component-based Radiative Transfer Model (PCRTM). It is 4 orders of magnitude faster than a line-by-line radiative transfer model while keeping a similar accuracy (0.03 K RMS errors with close to zero bias). The PCRTM includes multiple scattering of clouds and non-thermodynamics equilibrium of CO2 in the RT calculations. Instead of quantifying the radiometric differences between AIRS/AMSU and CrIS/ATMS measurements directly using Simultaneous Nadir Overpass (SNO) or Double Difference Technique (DDT), we use the radiometric consistent fingerprinting scheme to derive two sets of space-time averaged anomalies from the Level 1 data of AIRS/AMSU and CrIS/ATMS. The derived anomalies in geophysical space will form a long-term, stable, and continuous climate data record. We can further infer the causes of any offset or drift by studying the differences between two overlapping data sets. For example, the offset in surface skin temperature anomaly time series will most likely caused by the Blackbody temperature calibration errors of the sounder instruments.

climate↗

Towards exact finite temperature electronic structure in solids and molecules (Final Technical Report)

This report describes the University of Iowa portion of a project that is now continuing at Michigan State University. We are developing novel methods, algorithms, and software to enable simulations of molecules and materials at high temperature. This is a key challenge in chemistry and materials science. By refining an approach called Density Matrix Quantum Monte Carlo (DMQMC), we developed faster and more accurate ways to conduct these simulations. These advances will help us understand how temperature affects the behavior of electrons, chemical bonds, and phase transitions in solids and molecules. These breakthroughs are especially important for applications where light and heat drive chemical reactions, superconductivity, and materials used in energy and sensing. In addition, this project involved the development of the open-source HANDE-QMC software package, supporting the broader community in benchmarking and developing finite-temperature electronic structure methods.

36 MATERIALS SCIENCE↗

Temperature Mapping of Stacked Silicon Dies from X-Ray-Diffraction Intensities

Increasing power densities in integrated circuits have led to an increased prevalence of thermal hotspots in integrated circuits. Tracking these thermal hotspots is imperative to prevent circuit failures. In three- dimensional (3D) integrated circuits, conventional surface techniques like infrared thermometry are unable to measure the 3D temperature distribution, and optical and magnetic resonance techniques are difficult to apply due to the presence of metals and large current densities. X-rays offer a high penetration depth and can be used to probe 3D structures. We report a method utilizing the temperature dependence of x-ray-diffraction intensity via the Debye-Waller factor to simultaneously map the temperature of individual silicon dies in a stack. Here, utilizing beamline 1-ID-E at the Advanced Photon Source (Argonne), we demonstrate, for each individual silicon die, a temperature resolution of 3 K, a spatial resolution of 100 × 400 μm 2 , and a temporal resolution of 20 s. Utilizing a sufficiently high-intensity laboratory source, e.g., from a liquid-anode source, this method can be scaled down to laboratories for noninvasive temperature mapping of 3D integrated circuits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmic axions revealed via amplified modulation of the ellipticity of a laser

We propose a new axion dark matter detection strategy that employs optical readout of laser beam ellipticity modulations caused by axion-induced electric fields in a microwave cavity, using electro-optic (EO) crystals, enhanced by externally injected radio-frequency (rf) power. Building upon the variance-based probing method [Phys. Rev. D 107, 103005 (2023).], we extend this concept to the optical domain: A weak probe laser interacts with an EO crystal coupled to the resonant microwave cavity field at cryogenic temperatures, and the axion-induced electric field is revealed through induced ellipticity. The injected rf signal coherently interferes with that of the axion field, amplifying the optical response and significantly improving sensitivity. While our EO-based method employs a Fabry-Pérot resonator, we do not require Michelson interferometers. Our method, hence, enables compact, high-frequency axion searches, across the 0.5–50 GHz range. Operating at cryogenic temperatures not only suppresses thermal backgrounds, but, critically, allows the probing method to mitigate the quantum noise. This approach offers a scalable path forward for axion detection over the ∼(few−200) μ⁢eV mass range—covering the preferred parameter space for the postinflationary Peccei-Quinn axion dark matter—using compact, tunable systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fabrication of ceramic to metal graded structure for high temperature CSP receiver application using solid state additive manufacturing

The overarching goal of this project is to come up with an innovative joining solution for integration of SiC ceramic to structural materials such as stainless steels (SS)/Ni-base alloys, where intimate metallurgical bonding between SiC ceramic and the structural metallic alloy is demonstrated at the interface. Implementation of a simple, yet robust joining method would help in increasing the application space of SiC in a high-temperature CSP (concentrated solar power) plant, especially in the receiver section. This research goal has been achieved by creating a functionally graded material (FGM) interface between SiC and the selected structural material with the help of powder metallurgy (PM) approach and demonstrate intimate metallurgical bonding between monolithic RB-SiC and 316L stainless steel alloy blanks.

36 MATERIALS SCIENCE↗

High temperature materials characterization

A lab facility for measuring elastic moduli up to 1700 C was constructed and delivered. It was shown that the ultrasonic method can be used to determine elastic constants of materials from room temperature to their melting points. The ease in coupling high frequency acoustic energy is still a difficult task. Even now, new coupling materials and higher power ultrasonic pulsers are being suggested. The surface was only scratched in terms of showing the full capabilities of either technique used, especially since there is such a large learning curve in developing proper methodologies to take measurements into the high temperature region. The laser acoustic system does not seem to have sufficient precision at this time to replace the normal buffer rod methodology.

Workman, Gary L.↗

Density fluctuations and radiated noise for a high-temperature supersonic jet

Experimental data on density fluctuations were obtained by the laser Schlieren method in a supersonic jet which at the nozzle exit had a Mach number of 1.43 and a stagnation temperature of about 1090 K. The jet emerged into the ambient atmosphere in an anechoic chamber, correctly expanded from a nozzle which had an exit diameter of 10.8 cm. Using the information on the density fluctuations and the mean shear obtained by probes, the autocorrelation of the radiated noise was calculated by a theory that is suitable for Mach wave emission. This theory is a modification of that developed by Ffowcs Williams and Maidanik (1965). The calculated noise field agrees well with that obtained by using microphones outside the jet.

Parthasarathy, S. P.↗

Computational simulation of microfracture in high temperature metal matrix composites

A computational simulation procedure, using three-dimensional finite element method and global strain energy release rates, is described to predict the microfracture process and identify/quantify the hierarchy of respective fracture modes in metal matrix composites. The procedure is used to predict the microfracture in unidirectional composites under longitudinal loads and accounts for the interphase strength in the in situ state. A novel procedure to computationally simulate the fiber pushthrough process is also described. In this simulation, the interface material is replaced by an anisotropic material with greatly reduced shear modulus in order to simulate the fiber pushthrough process using a linear analysis. Such a procedure is easily implemented and is computationally very effective.

Mital, Subodh K.↗

High performance miniature hygrometer and method thereof

An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.

VanZandt, Thomas R.↗

High-temperature, high-pressure optical cells

For measuring the thermal diffusivity of HgCdTe melts by the laser-pulse method, an infrared transparent cell with flat windows of sufficient strength to withstand the high-vapor pressure of mercury had to be developed. Since mercury telluride expands on freezing, certain difficulties arose in returning the cell to room temperature without cracking it. T08 commercial fused silica is used in the construction of the cell, and the cells are transparent for wavelengths from about 3.5 microns in the infrared to 260 nm in the ultraviolet. The construction procedure for the required cells has been laborious. However, the obtained cell has routinely withstood internal pressures in excess of 60 atm at 900 C. Attention is given to the design of the windows, aspects of cell construction, and questions of loading.

Holland, L. R.↗

Initial development and verification of a primary load design method based on elastic-perfectly plastic analysis

This report describes a new primary load design method to supplement the current design-by-elastic-analysis rules in Section III, Division 5, Subsection HB, Subpart B of the ASME Boiler and Pressure Vessel Code, covering the design and construction of Class A high temperature nuclear structural components. The main objectives for the new design method are to provide a procedure that can be applied to components with complicated geometries and to simplify the primary load design process by providing rules more compatible with modern finite element analysis. The report includes a complete set of design rules, presented as a draft ASME Code Case, as well as a commentary on the rules and a set of verification problems. The verification design problems demonstrate the new primary load design rules produce safe, efficient components when compared to the current Division 5 approach, while greatly simplifying the design analysis process.

42 ENGINEERING↗

Enhancing the Chemical Energy Flux in a High-Temperature Tubular Counterflow Solid Fuel Synthesis Reactor Using a Bypass

Redox reactions of metal oxides offer a path towards using intermittent renewable resources for high-density thermochemical energy storage. Thermochemical energy storage often involves the flow of a particulate media. We describe a novel method to increase the throughput in a gravity-driven high-temperature thermochemical storage reactor flowing pelletized MgMnO. The moving bed reactor operates under counter-flow conditions and encounters particle flowability problems at temperatures of 1500 °C leading to sintering of the bed. Inertial forces of a counter-flowing gas can overcome the gravitational forces on the particles and limit the chemical energy storage rate of the reactor. We found that the insertion of a gas bypass (a slotted tube) into the reactor results in a 100% increase of the flow rates and achieved a 50% higher chemical energy storage flux compared to the operation without a bypass tube while mitigating the effects of sintering on the particles. As a result, the higher solid flow rates require a longer heated zone to reach a comparable residence time and extent of reduction compared to the lower flow rates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility of Coupling Between a Single-Mode Elliptical-Core Fiber and a Single Mode Rib Waveguide Over Temperature

To determine the feasibility of coupling the output of an optical fiber to a rib waveguide in a temperature environment ranging from 20 C to 300 C, a theoretical calculation of the coupling efficiency between the two was investigated. This is a significant problem which needs to be addressed to determine whether an integrated optic device can function in a harsh temperature environment. Because the behavior of the integrated-optic device is polarization sensitive, a polarization-preserving optic fiber, via its elliptical core, was used to couple light with a known polarization into the device. To couple light energy efficiently from an optical fiber into a channel waveguide, the design of both components should provide for well-matched electric field profiles. The rib waveguide analyzed was the light input channel of an integrated-optic pressure sensor. Due to the complex geometry of the rib waveguide, there is no analytical solution to the wave equation for the guided modes. Approximation or numerical techniques must be utilized to determine the propagation constants and field patterns of the guide. In this study, three solution methods were used to determine the field profiles of both the fiber and guide: the effective-index method (EIM), Marcatili's approximation, and a Fourier method. These methods were utilized independently to calculate the electric field profile of a rib channel waveguide and elliptical fiber at two temperatures, 20 C and 300 C. These temperatures were chosen to represent a nominal and a high temperature that the device would experience. Using the electric field profile calculated from each method, the theoretical coupling efficiency between the single-mode optical fiber and rib waveguide was calculated using the overlap integral and results of the techniques compared. Initially, perfect alignment was assumed and the coupling efficiency calculated. Then, the coupling efficiency calculation was repeated for a range of transverse offsets at both temperatures. Results of the calculation indicate a high coupling efficiency can be achieved when the two components were properly aligned. The coupling efficiency was more sensitive to alignment offsets in the y direction than the x, due to the elliptical modal profile of both components. Changes in the coupling efficiency over temperature were found to be minimal.

Tuma, Margaret L.↗

Method for measuring static Young's modulus of tungsten to 1900 K

An instrument system was developed and tested to measure static Young's modulus of elasticity of refractory metals in tension at temperatures to 1900 K. The extensometer uses capacitance displacement sensors for measuring total elongation of a specimen and incorporates a unique high-resolution remote zero-adjusting mechanism. Details of a method for calibrating capacitance displacement sensors at temperatures to 800 K are included. The system was built to adapt to a vacuum furnace on a tensile machine and was tested on unalloyed tungsten rod specimens. The test results show that the system can measure the modulus of tungsten to 1900 K to within a precision of + or - 5 percent. The uncertainty of the measurement is estimated to be of the same order as the precision.

Harrigill, W. T., Jr.↗

High Temperature Mechanical Behavior of Polycrystalline Alumina from Mixed Nanometer and Micrometer Powders

Sintered aluminum oxide materials were formed using commercial methods from mechanically mixed powders of nano-and micrometer alumina. The powders were consolidated at 1500 and 1600 C with 3.2 and 7.2 ksi applied stress in argon. The conventional micrometer sized powders failed to consolidate. While 100 percent nanometer-sized alumina and its mixture with the micrometer powders achieved less than 99 percent density. Preliminary high temperature creep behavior indicates no super-plastic strains. However high strains (less than 0.65 percent) were generated in the nanometer powder, due to cracks and linked voids initiated by cavitation.

Goldsby, Jon C.↗

Ionic‐Liquid Free and Flexible Transistors Made of 2D Material Inks

The development of thin-film transistors (TFTs) using 2D materials is crucial for enabling scalable, low-cost, and flexible electronics. Currently, 2D TFTs with the highest performance have been achieved by using ionic-liquid gating (ILG), a technique suited for proof-of-concept studies. However, ILG suffers from slow switching speeds, temperature sensitivity, poor long-term stability, and integration challenges, making it unsuitable for practical use. Moreover, typical fabrication methods for 2D TFTs involve harsh conditions such as strong acids or high temperatures (>300 °C), limiting integration with flexible substrates. This work provides the first demonstration of an ILG-free, all-2D-material TFT fabricated onto a flexible substrate. Water-based graphene and hexagonal boron nitride (h-BN) inks are printed to deposit the electrodes and dielectric layers, respectively. The MoS 2 channel is produced via supramolecular interfacial self-assembly, yielding uniform, monolayer-rich films transferable to rigid and flexible substrates. The resulting TFTs operate below 3 V, exhibit negligible leakage current, and achieve field-effect mobilities up to 0.46 cm 2 V −1 s −1 (rising to 2.47 cm 2 V −1 s −1 with silver electrodes) measured under ambient conditions, while maintaining excellent mechanical flexibility. This work establishes a low-cost and scalable solution-processable platform for flexible electronics based on 2D materials that match requirements for practical applications.

2D materials↗

Extraction of amino acids from soils and sediments with superheated water

A method of extraction for amino acids from soils and sediments involving superheated water has been investigated. About 75-97 per cent of the amino acids contained in four soils of a soil profile from Illinois were extracted by this method. Deep penetration of water into soil aggregates and partial hydrolysis of peptide bonds during this extraction by water at high temperature are likely mechanisms responsible for the release of amino acids from samples. This extraction method does not require subsequent desalting treatments when analyses are carried out with an ion-exchange amino acid analyzer.

Cheng, C. N.↗