Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Funding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Author Correction: Engineering self-deliverable ribonucleoproteins for genome editing in the brain

Correction to: Nature Communicationshttps://doi.org/10.1038/s41467-024-45998-2, published online 26 February 2024. In the Acknowledgements section of this article, the grant number relating to National Institutes of Health funding to J.A.D. was incorrectly given as RM1HG009490 and should have been U19NS132303. The grant number 2334028 relating to the National Science Foundation funding to J.A.D. was omitted. Funding from Hampton University Summer Undergraduate Research Program, Mr. Li Ka Shing, Emerson Collective and the Innovative Genomics Institute (IGI) were omitted. The original article has been corrected.

60 APPLIED LIFE SCIENCES↗

Information Connections among Multiple Investors: Evolutionary Local Patterns Revealed by Motifs

The concept of motifs provides a fresh perspective for studying local patterns, which is useful for understanding the essence of a network structure. However, few previous studies have focused on the evolutionary characteristics of weighted motifs while further considering participants’ differences. We study how information connections differ among multiple investors. The evolutionary 10-year trend of weighted 3-motifs in China’s energy stock markets is explored for the networks of co-holding behaviors among shareholders, who are classified as companies, funds and individuals. Our works allow us to detect the preferential local patterns distributed among different agents as their fluctuate involvement in networks. We find that the diversity of shareholders contributes to the statistical significance of local patterns, while homophily always exist among individuals. Modules of information connections are stable among reserved investors, which is especially apparent among companies. Individuals prefer to keep their connections with companies and funds. Unsteady modules happen owing to strengthen links among funds during the time that they are main participants in stock markets. More details about multiple investors informationally connected in evolutionary local patterns can be detected by our work.

99 GENERAL AND MISCELLANEOUS↗

The interaction of reactants, intermediates and products with Cu ions in Cu-SSZ-13 NH3 SCR catalysts: An energetic and ab initio X-ray absorption modeling study

Copper-exchanged SSZ-13 (Cu-SSZ-13) provides excellent catalytic activity and hydrothermal stability in the selective catalytic reduction (SCR) of NOx by using NH3 as a reductant. In this contribution, we compare the most likely positions for Cu with a single charge compensating Al atom (ZCu), including the effect of the adsorption of reactants, intermediates and products of a NH3 SCR reaction by using first-principles calculations based on density functional theory. We find that the 6-membered ring (6MR) site is the most energetically favorable while the 8-membered ring (8MR) sites are less favorable with energy differences about 0.5 eV with respect to the 6MR site. Upon molecular adsorption, the energy differences between Cu in the 8MR and 6MR sites decreases and almost disappears, which means that the thermodynamic stability of ZCu with molecularly adsorbed species is nearly identical for Cu in different sites. Considering more complicated scenarios of NO (or CO) adsorption, we find that the co-adsorption of 2 NO (or 2 CO) molecules weakens their interaction with Cu, as well as their co-adsorption with OH and H2O. The X-ray absorption near edge structure (XANES) of Cu in Cu-SSZ-13 under different conditions was also modeled from first principles. We find that the pre-edge feature in the K-edge XANES of Cu in clean Cu-SSZ-13 with Cu in a 8MR site is induced by a 1s to 4s transition while there is no pre-edge peak when Cu is in a 6MR site. Molecular adsorption onto Cu in a 6MR or a 8MR site results in the same K-edge XANES. When NO is adsorbed onto Cu in SSZ-13, we find that the origin of the small pre-edge peak in the K-edge XANES lies in a 1s to 3d electron transition. On the other hand, when CO or N2 is adsorbed onto an isolated Cu atom in SSZ-13, a transition from the 1s state to the hybridized state of 3d and 4p results in a pre-edge peak in the K-edge of the XANES spectrum. It is also found that the edge position and intensity of the maximum peak of Cu K-edge XANES depend on the Cu locations and the adsorbed molecules. By studying the Cu K-edge XANES of ZCu with adsorption of species of different oxidizing power, we conclude that a higher oxidation state of Cu will result in a higher energy edge position in the Cu K-edge XANES. These results are expected to greatly aid our understanding of Cu-SSZ-13 SCR catalysts. This work was supported by institutional funds provided to JSM from the Voiland School of Chemical Engineering and Bioengineering. Financial support was also provided by the National Science Foundation GOALI program under contract Nos. CBET-1258717, CBET-1258715 and CBET-1258690. We thank Prof. Fabio Ribeiro, Mr. Atish Parekh, Prof. W. F. Schneider, Mr. Christopher Paolucci, Mr. Trunjoyo Anggara and Prof. Jeff Miller for stimulating discussions on the modeling of the XANES spectrum and Ms. Alyssa Hensley for her comments on the manuscript. J.Sz. acknowledges the financial support of this work by the U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy, Vehicle Technologies Program. A portion of the computer time for the computational work was performed using EMSL, a national scientific user facility sponsored by the Department of Energy’s Office of Biological and Environmental Research and located at PNNL. PNNL is a multi-program national laboratory operated for the US DOE by Battelle.

Zhang, Renqin↗

Beamed Energy Propulsion: Research Status And Needs--Part 2

One promising solution to the operationally responsive space is the application of remote electromagnetic energy to propel a launch vehicle into orbit. With beamed energy propulsion, one can leave the power source stationary on the ground or space, and direct heat propellant on the spacecraft with a beam from a fixed station. This permits the spacecraft to leave its power source at home, saving significant amounts of mass, greatly improving performance. This concept, which removes the mass penalty of carrying the propulsion energy source on board the vehicle, was first proposed by Arthur Kantrowitz in 1972; he invoked an extremely powerful ground based laser. The same year Michael Minovich suggested a conceptually similar 'in-space' laser rocket system utilizing a remote laser power station. In the late 1980's, Air Force Office of Scientific Research (AFOSR) funded continuous, double pulse laser and microwave propulsion while Strategic Defense Initiative Office (SDIO) funded ablative laser rocket propulsion. Currently AFOSR has been funding the concept initiated by Leik Myrabo, repetitively pulsed laser propulsion, which has been universally perceived, arguably, to be the closest for mid-term applications. This 2-part paper examines the investment strategies in beamed energy propulsion and technical challenges to be covers Part 2 covers the present research status and needs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Beamed Energy Propulsion: Research Status And Needs--Part 1

One promising solution to the operationally responsive space is the application of remote electromagnetic energy to propel a launch vehicle into orbit. With beamed energy propulsion, one can leave the power source stationary on the ground or space, and direct heat propellant on the spacecraft with a beam from a fixed station. This permits the spacecraft to leave its power source at home, saving significant amounts of mass, greatly improving performance. This concept, which removes the mass penalty of carrying the propulsion energy source on board the vehicle, was first proposed by Arthur Kantrowitz in 1972; he invoked an extremely powerful ground based laser. The same year Michael Minovich suggested a conceptually similar 'in-space' laser rocket system utilizing a remote laser power station. In the late 1980's, Air Force Office of Scientific Research (AFOSR) funded continuous, double pulse laser and microwave propulsion while Strategic Defense Initiative Office (SDIO) funded ablative laser rocket propulsion. Currently AFOSR has been funding the concept initiated by Leik Myrabo, repetitively pulsed laser propulsion, which has been universally perceived, arguably, to be the closest for mid-term applications. This 2-part paper examines the investment strategies in beamed energy propulsion and technical challenges to be overcome. Part 1 presents a world-wide review of beamed energy propulsion research, including both laser and microwave arenas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Progress towards developing neutron tolerant magnetostrictive and piezoelectric transducers

Current generation light water reactors (LWRs), sodium cooled fast reactors (SFRs), small modular reactors (SMRs), and next generation nuclear plants (NGNPs) produce harsh environments in and near the reactor core that can severely tax material performance and limit component operational life. To address this issue, several Department of Energy Office of Nuclear Energy (DOE-NE) research programs are evaluating the long duration irradiation performance of fuel and structural materials used in existing and new reactors. In order to maximize the amount of information obtained from Material Testing Reactor (MTR) irradiations, DOE is also funding development of enhanced instrumentation that will be able to obtain in-situ, real-time data on key material characteristics and properties, with unprecedented accuracy and resolution. Such data are required to validate new multi-scale, multi-physics modeling tools under development as part of a science-based, engineering driven approach to reactor development. It is not feasible to obtain high resolution/microscale data with the current state of instrumentation technology. However, ultrasound-based sensors offer the ability to obtain such data if it is demonstrated that these sensors and their associated transducers are resistant to high neutron flux, high gamma radiation, and high temperature. To address this need, the Advanced Test Reactor National Scientific User Facility (ATR-NSUF) is funding an irradiation, led by PSU, at the Massachusetts Institute of Technology Research Reactor to test the survivability of ultrasound transducers. As part of this effort, PSU and collaborators have designed, fabricated, and provided piezoelectric and magnetostrictive transducers that are optimized to perform in harsh, high flux, environments. Four piezoelectric transducers were fabricated with either aluminum nitride, zinc oxide, or bismuth titanate as the active element that were coupled to either Kovar or aluminum waveguides and two magnetostrictive transducers were fabricated with Remendur or Galfenol as the active elements. Pulse-echo ultrasonic measurements of these transducers are made in-situ. This paper will present an overview of the test design including selection criteria for candidate materials and optimization of test assembly parameters, data obtained from both out-of-pile and in-pile testing at elevated temperatures, and an assessment based on initial data of the expected performance of ultrasonic devices in irradiation conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CSP Plant Construction, Start-Up, and O&M Best Practices Study

There are currently 90 operational CSP plants of 10 MW or larger located throughout the world, primarily in Spain, U.S., MENA region, South Africa, and China. In 2018, the U.S. Department of Energy (DOE) funded Solar Dynamics, under subcontract to NREL, to investigate and document lessons learned and best practices associated with the construction, start-up, and operations phases of a majority of these plants. DOE funding for the effort was leveraged by additional funds provided through SolarPACES and the World Bank. This information was obtained by interviewing key stakeholders representing CSP plant owners, operators, construction companies, vendors, technical advisors and financers of these systems, and will be published as an NREL Technical Report at the completion of the project. This paper provides an overview of key challenges facing today's CSP parabolic trough and power tower technologies during all the phases mentioned above.

41 EE - Solar Energy Technologies Office (EE-4S)↗

APS: High-Energy X-rays Expediting Applied and Fundamental Research

The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) was designed and built as one of the first large 3rd generation synchrotrons operated at 7 GeV. The United States Department of Energy (DOE) Office of Science funded the construction and continues to fund the operation of this national facility. Furthermore, the beamlines were originally operated by Collaborative Access Teams (CAT), which allowed a strong involvement of research institutes, universities, and industry. Today 43 of 68 beamlines are operated by the X-ray Science Division (XSD) and 35 beamlines are directly funded by the DOE Office of Science. The APS became operational in 1995, and was planned right from the beginning with 4 beamlines dedicated to high-energy x-rays above 40 keV: 1-ID designed to study engineering materials science, 6-ID-D for magnetism and condensed matter research, 11-ID-B dedicated to magnetic Compton scattering using an Elliptical Multipole Wiggler, and 11-ID-C for materials science and condensed matter physics. These stations were later joined by the bending magnet beamlines 6-BM for white beam studies and 17-BM for rapid powder diffraction. CAT operated beamlines such as 15-ID for crystallography or 16-ID for high-pressure studies also use the high-energy x-ray regime frequently. The program in Compton scattering ended in 2004 and the wiggler was replaced by an undulator. 11-ID-B became the first dedicated station for Pair Distribution Function (PDF) Analysis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data Mining Scientific Literature Demonstrates Use of Biological and Medical Data Across Scientific Disciplines

The Protein Data Bank (PDB) was established as the 1st open access digital data resource in biology and medicine. Today, the PDB archive contains over 140,000 atomic‐level biomolecular structures determined by crystallography, NMR spectroscopy, and 3D electron microscopy. About 20 new structures are deposited daily. PDB data is used in basic and applied research, patent applications, discovery of lifesaving drugs, product innovation, and education. About 80% of all PDB structures deposited have a “primary citation,” which is the first paper to describe the molecule and its structure and function. In turn, these primary citations have contributed to more than 1 million publications. An initial study by Clarivate Analytics on the Nucleic Acids Research publication demonstrated that PDB data drive high‐impact research in diverse scientific fields. To build on this study, we used Python programming to perform several data mining studies to understand the impact of these structures in fundamental biology, biomedicine, and energy in the scientific literature. The scientific literature database, Web of Science, tracks scientific article metrics such as the number of times cited, subject category, year published, funding source, and keywords. Web of Science data for PDB primary citations was compiled as used as the data set. Two main investigations were performed. In the first, we examined the number of citations per article (data overall and by individual subject categories) to develop “top 10 cited structures” lists and analyzed for trends. In the second investigation, we extended our data mining analysis to consider for each main subject category, the papers with the most citations and the structures they cite, and the most frequently occuring keywords. We have observed different aspects of biological data utility in various subject areas, at times in ways unanticipated from the structures' primary citation. This research demonstrates the value of biological data from the PDB by showing the diverse ways in which the data are being used. Support or Funding Information RCSB PDB is funded by a grant (DBI‐1338415) from the National Science Foundation, the National Institutes of Health, and the US Department of Energy. This abstract is from the Experimental Biology 2019 Meeting. There is no full text article associated with this abstract published in The FASEB Journal .

Verdiguel, Natalie↗

The engagement and performance operations center: Epoc

In 2018, the US National Science Foundation (NSF) funded the Engagement and Performance Operations Center (EPOC), a joint project between Indiana University (IU) and the Department of Energy's Energy Science Network (ESnet), to work with domain scientists to accelerate the ability of distributed collaborations to share data in order to reach broader science goals. The goal of this funding was to create an operations center for engagement-including definition of formal processes, tracking of engagements, and funded staff, not simply best effort by volunteers, with a goal of enabling digital societies to better share scientific data.

Moynihan, E↗

SU-E-J-14: A Novel Approach to Evaluate the Dosimetric Effect of Rectal Variation During Image Guided Prostate Radiotherapy

Purpose: Deformable registration establishes the spatial correspondence back to the reference image in order to accumulate dose. However, in prostate radiotherapy the changing shape and volume of the rectum present a challenge to accurate deformable registration and consequently calculation of delivered dose. We explored an alternative approach to calculating accumulated dose to the rectum, independent of deformable registration. Methods: This study was performed on three patients who received online image-guided radiotherapy (IGRT) with daily CBCT (XVI-system,Elekta) and target localization using intraprostatic fiducials. On each CBCT, the rectum was manually contoured and bulk density assignments were made allowing dose to be calculated for each fraction. Dose-surface maps (DSM) were generated (MATLAB,Mathworks,Natick,MA) by considering the rectum as a cylinder and sampling the dose at 21-equispaced points on each CT slice. The cylinder was “cut” at the posterior-most position on each CT and unfolded to generate a DSM. These were normalised in the longitudinal direction by interpolation creating maps of 21×21 pixels. A DSM was produced for each CBCT and the dose was accumulated. Results: The mean accumulated delivered rectal surface dose was on average 7.5(+/−3.5)% lower than the planned dose. The dose difference maps consistently show that the greatest variation in dose between planned and delivered dose is away from where the rectal surface is adjacent to the prostate. Conclusion: Estimation of dose accumulation using DSM provides an alternative method for determining actual delivered dose to the rectum. The dose difference is greatest in areas away from the region where the rectal surface abuts the prostate, the region where set-up is verified. The change in size and shape of the rectum was shown to resultin a change in the accumulated dose compared to the planned dose and this will have an impact on determining the relationships between dose delivered and toxicity. We acknowledge funding from CRUK and acknowledge NHS funding to the NIHR Biomedical Research Centre for Cancer. Patients were treated within the CHHiP IGRT sub-study (CRUK/06/016, ISRCTN:97182923) funded by CRUK. RayStation was used under an evaluation agreement with RaySearch Laboratories AB.

60 APPLIED LIFE SCIENCES↗

SU-E-I-80: Quantification of Respiratory and Cardiac Motion Effect in SPECT Acquisitions Using Anthropomorphic Models: A Monte Carlo Simulation Study

Purpose: The purpose of the present study was to quantify, evaluate the impact of cardiac and respiratory motion on clinical nuclear imaging protocols. Common SPECT and scintigraphic scans are studied using Monte Carlo (MC) simulations, comparing the resulted images with and without motion. Methods: Realistic simulations were executed using the GATE toolkit and the XCAT anthropomorphic phantom as a reference model for human anatomy. Three different radiopharmaceuticals based on 99mTc were studied, namely 99mTc-MDP, 99mTc—N—DBODC and 99mTc—DTPA-aerosol for bone, myocardium and lung scanning respectively. The resolution of the phantom was set to 3.5 mm{sup 3}. The impact of the motion on spatial resolution was quantified using a sphere with 3.5 mm diameter and 10 separate time frames, in the ECAM modeled SPECT scanner. Finally, respiratory motion impact on resolution and imaging of lung lesions was investigated. The MLEM algorithm was used for data reconstruction, while the literature derived biodistributions of the pharmaceuticals were used as activity maps in the simulations. Results: FWHM was extracted for a static and a moving sphere which was ∼23 cm away from the entrance of the SPECT head. The difference in the FWHM was 20% between the two simulations. Profiles in thorax were compared in the case of bone scintigraphy, showing displacement and blurring of the bones when respiratory motion was inserted in the simulation. Large discrepancies were noticed in the case of myocardium imaging when cardiac motion was incorporated during the SPECT acquisition. Finally the borders of the lungs are blurred when respiratory motion is included resulting to a dislocation of ∼2.5 cm. Conclusion: As we move to individualized imaging and therapy procedures, quantitative and qualitative imaging is of high importance in nuclear diagnosis. MC simulations combined with anthropomorphic digital phantoms can provide an accurate tool for applications like motion correction techniques’ optimization. This research has been co-funded by the European Union (European Social Fund) and Greek national resources under the framework of the ‘Archimedes III: Funding of Research Groups in TEI of Athens’ project of the ‘Education & Lifelong Learning’ Operational Programme.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-00: Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-01: Clinical Implementation of An Electronic Brachytherapy Program for the Skin

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗

MO-D-BRD-02: Radiological Physics and Surface Lesion Treatments with Electronic Brachytherapy

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-03: Radiobiology and Commissioning of Electronic Brachytherapy for IORT

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-D-BRD-04: NIST Air-Kerma Standard for Electronic Brachytherapy Calibrations

Electronic brachytherapy (eBT) has seen an insurgence of manufacturers entering the US market for use in radiation therapy. In addition to the established interstitial, intraluminary, and intracavitary applications of eBT, many centers are now using eBT to treat skin lesions. It is important for medical physicists working with electronic brachytherapy sources to understand the basic physics principles of the sources themselves as well as the variety of applications for which they are being used. The calibration of the sources is different from vendor to vendor and the traceability of calibrations has evolved as new sources came to market. In 2014, a new air-kerma based standard was introduced by the National Institute of Standards and Technology (NIST) to measure the output of an eBT source. Eventually commercial treatment planning systems should accommodate this new standard and provide NIST traceability to the end user. The calibration and commissioning of an eBT system is unique to its application and typically entails a list of procedural recommendations by the manufacturer. Commissioning measurements are performed using a variety of methods, some of which are modifications of existing AAPM Task Group protocols. A medical physicist should be familiar with the different AAPM Task Group recommendations for applicability to eBT and how to properly adapt them to their needs. In addition to the physical characteristics of an eBT source, the photon energy is substantially lower than from HDR Ir-192 sources. Consequently, tissue-specific dosimetry and radiobiological considerations are necessary when comparing these brachytherapy modalities and when making clinical decisions as a radiation therapy team. In this session, the physical characteristics and calibration methodologies of eBt sources will be presented as well as radiobiology considerations and other important clinical considerations. Learning Objectives: To understand the basic principles of electronic brachytherapy and the various applications for which it is being used. To understand the physics of the calibration and commissioning for electronic brachytherapy sources To understand the unique radiobiology and clinical implementation of electronic brachytherapy systems for skin and IORT techniques Xoft, Inc. contributed funding toward development of the NIST electronic brachytherapy facility (Michael Mitch).The University of Wisconsin (Wesley Culberson) has received research support funding from Xoft, Inc. Zoubir Ouhib has received partial funding from Elekta Esteya.

60 APPLIED LIFE SCIENCES↗