Alternate Methods of Model Reduction to Avoid Dynamic Modal Truncation Error

Loads analysis is traditionally performed using dynamically reduced models, which provides the benefit to reduce run time. If the reduced model frequency cutoff is not chosen appropriately, the model will lack the dynamic content required to fully represent the response of the non-reduced model. Standard guidance for reduced model frequency content, provided in NASA-STD-5002, is to solve fixed base modes up to a minimum of 1.5x the model frequency content of interest and to employ static modal truncation methods such as residual vectors, the mode acceleration method, and the residual flexibility method to account for the truncated flexibility of the missing modes. Fixed base modes require the selection of a set of degrees of freedom to be constrained which, if not properly selected, may affect the accuracy of the reduced model by excluding some of the dynamic characteristic of the full model. In this case, the standard NASA guidance would be insufficient, but it may not be readily apparent that a portion of the reduced model response is missing. This error was encountered during an independent verification and validation (IV&V) effort, where it was observed that the resulting dynamic response was lower than the inline analysis. In this specific case, despite following the standard NASA model reduction guidelines in the selection of the frequency cutoff, the inline model still did not fully capture the necessary dynamic content. As part of the IV&V, an alternate reduction methodology was employed using an unconstrained mode acceleration method. The original model initially performed a constrained reduction to twice the frequency content of interest before doing a free-free run, employing the mode acceleration method to account for the truncated modes. In contrast in the IV&V, the unconstrained model reduced directly to the needed frequency content of the free-free run, avoiding any interactions between constraints and dynamic content. To verify the model, the original reduction methodology was used to generate a series of Hurty-Craig-Bampton reductions, each with a higher frequency cutoff than the previous. The results were shown to converge once the frequency cutoff increased past eight times the frequency content of interest. At the same frequency cutoff, the results of the Hurty-Craig-Bampton model converged with the results of the unconstrained mode acceleration model. This comparative study provided confidence that the results of the unconstrained modal acceleration reduced model were correct and that the Hurty-Craig-Bampton needed to increase its frequency cutoff to fully capture the dynamic response.

Erin Simmons↗

Radiation modeling and experimental validation of sub-cyclotron frequency microwave synchrotron radiation as a diagnostic tool for runaway electrons in present and future tokamaks

The microwave synchrotron radiation in the sub-cyclotron frequency region has been systematically validated as a diagnostic method for runaway electrons (>1 MeV) with radiation modeling and experiments on the DIII-D tokamak. Experimental observations reveal that sub-cyclotron frequency microwave radiation emerges only after runaway electrons are excited during plasma disruptions. Electron gyro-magnetic radiation modeling confirms that only runaway electrons with energies exceeding 1 MeV can emit radiation in the observed sub-cyclotron frequency band on DIII-D. The synchrotron Razin and Beaming effects are modeled in both the sub-cyclotron and standard Electron Cyclotron Emission (ECE) frequency region. Due to the pronounced beaming effect, the modeling supports that a standard ECE system is insensitive to synchrotron radiation from beamed runaway electrons (p ∥ >> p ⟂ ), but very sensitive to ECE radiation from isotropic suprathermal electrons (100 keV or less). DIII-D experiments further show that combining ECE and sub-cyclotron receivers reveals new insights into transient runaway dynamics during the plateau phase. Certain transient crash events appear only in the sub-cyclotron band or lead to opposite changes on the sub-cyclotron and standard ECE signals, supporting models where transient MHD events can exert a different effect on electrons of different energy levels. This novel diagnostic technique offers a powerful tool for studying and detecting runaway electron dynamics in both present-day and high-field future tokamaks. The diagnostic approach has been extrapolated to the SPARC tokamak, where sub-cyclotron radiation is predicted to respond sensitively and solely to runaway electrons during SPARC’s L-mode startup phase.

Yu, Guanying [Hefei Comprehensive National Science↗

Frequency domain laser velocimeter signal processor: A new signal processing scheme

A new scheme for processing signals from laser velocimeter systems is described. The technique utilizes the capabilities of advanced digital electronics to yield a smart instrument that is able to configure itself, based on the characteristics of the input signals, for optimum measurement accuracy. The signal processor is composed of a high-speed 2-bit transient recorder for signal capture and a combination of adaptive digital filters with energy and/or zero crossing detection signal processing. The system is designed to accept signals with frequencies up to 100 MHz with standard deviations up to 20 percent of the average signal frequency. Results from comparative simulation studies indicate measurement accuracies 2.5 times better than with a high-speed burst counter, from signals with as few as 150 photons per burst.

Meyers, James F.↗

Discrete diffusion Monte Carlo for frequency-dependent radiative transfer

Discrete Diffusion Monte Carlo (DDMC) is a technique for increasing the efficiency of Implicit Monte Carlo radiative-transfer simulations. In this paper, we develop an extension of DDMC for frequency-dependent radiative transfer. We base our new DDMC method on a frequency-integrated diffusion equation for frequencies below a specified threshold. Above this threshold we employ standard Monte Carlo. With a frequency-dependent test problem, we confirm the increased efficiency of our new DDMC technique.

97 MATHEMATICS AND COMPUTING↗

Mathematical Morphological Filtering with a Self-Adaptive Reconstruction Technique and Application to Local Seismic Data

Recorded seismic data are generally contaminated by noise from different sources, which masks the signals of interest. In the seismology community, frequency filtering (FF) is the standard method for noise suppression. However, when the signal of interest and noise share the same frequency band, the latter cannot be filtered out without infringing on the former. We implemented a noise suppression approach based on the mathematical morphology theorem. The method involves compound operations of dilation and erosion using structuring elements of varying lengths and decomposes an input noisy waveform into several time functions with differing characteristics. Further, the filtered waveform is constructed from the time functions using a self-adaptive reconstruction technique. Application to a data set of >4700 local waveforms suggests that the implemented mathematical morphological filtering (MMF) approach is efficient for data with low signal-to-noise ratio (SNR) and significantly outperforms FF in that SNR range. For most of the dataset, FF, machine learning (ML) denoising, and continuous wavelet transform (CWT) thresholding result in higher SNR values compared with the MMF method. However, for ~42% of the waveforms, MMF outperforms FF, and the SNR gain achieved with MMF is as large as ~23 dB. Compared to ML denoising and CWT thresholding, this proportion drops to only ~10%–14%. Our results suggests that in an operational setting, MMF cannot replace the other noise suppression methods; however, signal detection can be improved if MMF is used to supplement them in some scenarios. MMF could help detect signals in problematic low-SNR data, which are currently being missed particularly when using FF alone.

58 GEOSCIENCES↗

Electron-field instability: Excitation of electron plasma waves by an electric field

Electric fields are commonplace in plasmas and affect transport by driving currents and, in some cases, instabilities. The necessary condition for instability in collisionless plasmas is commonly understood to be described by the Penrose criterion, which quantifies a sufficient relative drift between different populations of particles that must be present for wave amplification via inverse Landau damping. For example, electric fields generate drifts between electrons and ions that can excite the ion-acoustic instability. Here, we use particle-in-cell simulations and linear stability analysis to show that the electric field can drive a fundamentally different type of kinetic instability, named the electron-field instability. This instability excites electron plasma waves with wavelengths ≳30λ De , has a growth rate that is proportional to the electric field strength, and does not require a relative drift between electrons and ions. The Penrose criterion does not apply when accounting for the electric field. Furthermore, the large value of the observed frequency, near the electron plasma frequency, further distinguishes it from the standard ion-acoustic instability, which oscillates near the ion plasma frequency. The ubiquity of macroscopic electric fields in quasineutral plasmas suggests that this instability is possible in a host of systems, including low-temperature and space plasmas. In fact, damping from neutral collisions in such systems is often not enough to completely damp the instability, adding to the robustness of the instability across plasma conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Binary pseudo-random array standard for extreme ultraviolet lithography tool characterization

Extreme ultraviolet (EUV) imaging tools play a crucial role in EUV lithography. Achieving high accuracy in EUV metrology is essential for advanced semiconductor manufacturing. A thorough characterization of the instrumentation in use is required. Binary pseudo-random arrays (BPRAs) are an established standard for calibrating and characterizing optical instruments in the frequency domain. Here, we expand the BPRA standard to applications in EUV imaging. To extend the technology to the EUV spectral range, a high-resolution BPRA target with the smallest feature size of 40 nm is developed. The EUV BPRA target establishes an in situ and portable calibration and alignment standard for EUV imaging. The target is patterned by means of electron-beam lithography, using a nickel absorber with a thickness of 39 nm. The substrate is a 4″ silicon wafer with a molybdenum/silicon multilayer coating. To demonstrate the efficacy of the target and develop the instrument calibration protocol, the target is imaged on the Sharp Hyper-NA Actinic Reticle Review Project EUV mask microscope. Power spectral density (PSD) data are presented. The characteristics of the imaging system are imprinted on the PSD. The modulation transfer function is extracted from the PSD data. A partially coherent imaging model is used as a reference to the experimental results.

BPRA↗

Control of ion content and nitrogen species using a mixed chemistry plasma for GaN grown at extremely high growth rates >9 μm/h by plasma-assisted molecular beam epitaxy

Utilizing a modified nitrogen plasma source, plasma assisted molecular beam epitaxy (PAMBE) has been used to achieve higher growth rates in GaN. A higher conductance aperture plate, combined with higher nitrogen flow and added pumping capacity, resulted in dramatically increased growth rates up to 8.4 μm/h using 34 sccm of N{sub 2} while still maintaining acceptably low operating pressure. It was further discovered that argon could be added to the plasma gas to enhance growth rates up to 9.8 μm/h, which was achieved using 20 sccm of N{sub 2} and 7.7 sccm Ar flows at 600 W radio frequency power, for which the standard deviation of thickness was just 2% over a full 2 in. diameter wafer. A remote Langmuir style probe employing the flux gauge was used to indirectly measure the relative ion content in the plasma. The use of argon dilution at low plasma pressures resulted in a dramatic reduction of the plasma ion current by more than half, while high plasma pressures suppressed ion content regardless of plasma gas chemistry. Moreover, different trends are apparent for the molecular and atomic nitrogen species generated by varying pressure and nitrogen composition in the plasma. Argon dilution resulted in nearly an order of magnitude achievable growth rate range from 1 μm/h to nearly 10 μm/h. Even for films grown at more than 6 μm/h, the surface morphology remained smooth showing clear atomic steps with root mean square roughness less than 1 nm. Due to the low vapor pressure of Si, Ge was explored as an alternative n-type dopant for high growth rate applications. Electron concentrations from 2.2 × 10{sup 16} to 3.8 × 10{sup 19} cm{sup −3} were achieved in GaN using Ge doping, and unintentionally doped GaN films exhibited low background electron concentrations of just 1–2 × 10{sup 15} cm{sup −3}. The highest growth rates resulted in macroscopic surface features due to Ga cell spitting, which is an engineering challenge still to be addressed. Nonetheless, the dramatically enhanced growth rates demonstrate great promise for the future of III-nitride devices grown by PAMBE.

36 MATERIALS SCIENCE↗

Investigation of the Moessbauer Spectrum Quality as a Dependence on the Frequency of the Velocity Signal

This paper is focused on a quality characterizing the Moessbauer spectra measured for various frequencies of the velocity signal. Standard electromechanical double-loudspeaker drive and digital PID velocity controller were used for calibration spectra measurement in the frequency interval from 4 up to 100 Hz. Several parameters were evaluated for recommendation of the suitable velocity signal frequency.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-204-05: Quantitative Comparison of a High Resolution Micro-Angiographic Fluoroscopic (MAF) Detector with a Standard Flat Panel Detector (FPD) Using the New Metric of Generalized Measured Relative Object Detectability (GM-ROD)

Purpose: In endovascular image-guided neuro-interventions, visualization of fine detail is paramount. For example, the ability of the interventionist to visualize the stent struts depends heavily on the x-ray imaging detector performance. Methods: A study to examine the relative performance of the high resolution MAF-CMOS (pixel size 75µm, Nyquist frequency 6.6 cycles/mm) and a standard Flat Panel Detector (pixel size 194µm, Nyquist frequency 2.5 cycles/mm) detectors in imaging a neuro stent was done using the Generalized Measured Relative Object Detectability (GM-ROD) metric. Low quantum noise images of a deployed stent were obtained by averaging 95 frames obtained by both detectors without changing other exposure or geometric parameters. The square of the Fourier transform of each image is taken and divided by the generalized normalized noise power spectrum to give an effective measured task-specific signal-to-noise ratio. This expression is then integrated from 0 to each of the detector’s Nyquist frequencies, and the GM-ROD value is determined by taking a ratio of the integrals for the MAF-CMOS to that of the FPD. The lower bound of integration can be varied to emphasize high frequencies in the detector comparisons. Results: The MAF-CMOS detector exhibits vastly superior performance over the FPD when integrating over all frequencies, yielding a GM-ROD value of 63.1. The lower bound of integration was stepped up in increments of 0.5 cycles/mm for higher frequency comparisons. As the lower bound increased, the GM-ROD value was augmented, reflecting the superior performance of the MAF-CMOS in the high frequency regime. Conclusion: GM-ROD is a versatile metric that can provide quantitative detector and task dependent comparisons that can be used as a basis for detector selection. Supported by NIH Grant: 2R01EB002873 and an equipment grant from Toshiba Medical Systems Corporation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polishing the Gold Standard: The Role of Orbital Choice in CCSD(T) Vibrational Frequency Prediction

While CCSD(T) with spin-restricted Hartree-Fock (RHF) orbitals has long been lauded for its ability to accurately describe closed-shell interactions, the performance of CCSD(T) on open-shell species is much more erratic, especially when using a spin-unrestricted HF (UHF) reference. Previous studies have shown improved treatment of open-shell systems when a non-HF set of molecular orbitals, like Brueckner or Kohn-Sham density functional theory (DFT) orbitals, is used as a reference. Inspired by the success of regularized orbital-optimized second-order Møller-Plesset perturbation theory (κ-OOMP2) orbitals as reference orbitals for MP3, we investigate the use of κ-OOMP2 orbitals and various DFT orbitals as reference orbitals for CCSD(T) calculations of the corrected ground-state harmonic vibrational frequencies of a set of 36 closed-shell (29 neutrals, 6 cations, 1 anion) and 59 open-shell diatomic species (38 neutrals, 15 cations, 6 anions). The aug-cc-pwCVTZ basis set is used for all calculations. The use of κ-OOMP2 orbitals in this context alleviates difficult cases observed for both UHF orbitals and OOMP2 orbitals. Removing two multireference systems and 12 systems with ambiguous experimental data leaves a pruned data set. Overall performance on the pruned data set highlights CCSD(T) with a B97 orbital reference (CCSD(T):B97), CCSD(T) with a κ-OOMP2 orbital reference (CCSD(T):κ-OOMP2), and CCSD(T) with a B97M-rV orbital reference (CCSD(T):B97M-rV) with RMSDs of 8.48 cm -1 , and 8.50 cm -1 , and 8.75 cm -1 respectively, outperforming CCSD(T):UHF by nearly a factor of 5. Moreover, the performance on the closed- and open-shell subsets shows these methods are able to treat open-shell and closed-shell systems with comparable accuracy and robustness. CCSD(T) with RHF orbitals is seen to improve upon UHF for the closed-shell species, while spatial symmetry breaking in a number of restricted open-shell HF (ROHF) references leads CCSD(T) with ROHF reference orbitals to exhibit the poorest statistical performance of all methods surveyed for open-shell species. The use of κ-OOMP2 orbitals has also proven useful in diagnosing multireference character that can hinder the reliability of CCSD(T).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

THE X-RAY ENERGY DEPENDENCE OF THE RELATION BETWEEN OPTICAL AND X-RAY EMISSION IN QUASARS

We develop a new approach to the well-studied anti-correlation between the optical-to-X-ray spectral index, alpha{sub ox}, and the monochromatic optical luminosity, l{sub opt}. By cross-correlating the Sloan Digital Sky Survey DR5 quasar catalog with the XMM-Newton archive, we create a sample of 327 quasars with X-ray signal-to-noise ratio (S/N) > 6, where both optical and X-ray spectra are available. This allows alpha{sub ox} to be defined at arbitrary frequencies, rather than the standard 2500 A and 2 keV. We find that while the choice of optical wavelength does not strongly influence the alpha{sub ox}-l{sub opt} relation, the slope of the relation does depend on the choice of X-ray energy. The slope of the relation becomes steeper when alpha{sub ox} is defined at low (approx1 keV) X-ray energies. This change is significant when compared to the slope predicted by a decrease in the baseline over which alpha{sub ox} is defined. The slopes are also marginally flatter than predicted at high (approx10 keV) X-ray energies. Partial correlation tests show that while the primary driver of alpha{sub ox} is l{sub opt}, the Eddington ratio correlates strongly with alpha{sub ox} when l{sub opt} is taken into account, so accretion rate may help explain these results. We combine the alpha{sub ox}-l{sub opt} and GAMMA-L{sub bol}/L{sub Edd} relations to naturally explain two results: (1) the existence of the GAMMA-l{sub x} relation as reported in Young et al., and (2) the lack of a GAMMA-l{sub opt} relation. The consistency of the optical/X-ray correlations establishes a more complete framework for understanding the relation between quasar emission mechanisms. We also discuss two correlations with the hard X-ray bolometric correction, which we show correlates with both alpha{sub ox} and Eddington ratio. This confirms that an increase in accretion rate correlates with a decrease in the fraction of up-scattered disk photons.

79 ASTRONOMY AND ASTROPHYSICS↗

Search for variation of fundamental constants and violations of fundamental symmetries using isotope comparisons

Atomic microwave clocks based on hyperfine transitions, such as the caesium standard, tick with a frequency that is proportional to the magnetic moment of the nucleus. This magnetic moment varies strongly between isotopes of the same atom, while all atomic electron parameters remain the same. Therefore the comparison of two microwave clocks based on different isotopes of the same atom can be used to constrain variation of fundamental constants. In this paper, we calculate the neutron and proton contributions to the nuclear magnetic moments, as well as their sensitivity to any potential quark-mass variation, in a number of isotopes of experimental interest including {sup 201,199}Hg and {sup 87,85}Rb, where experiments are underway. We also include a brief treatment of the dependence of the hyperfine transitions to variation in nuclear radius, which in turn is proportional to any change in quark mass. Our calculations of expectation values of proton and neutron spin in nuclei are also needed to interpret measurements of violations of fundamental symmetries.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Aerosol-Jet Printed Transferable Millimeter-Wave Circuits

Printed millimeter wave (mmW) electronics have been of high interest in the field of communications for some time now due to the potential ability to fabricate mmW systems that utilize 3-Dimension Heterogeneous Integration (3DHI) to improve performance beyond traditional systems. Here, in this paper, a method for fabricating transferable mmW structures via aerosol-jet printing (AJP) is presented. A PDMS stamp assisted liftoff procedure is developed to separate the printed part from a rigid printing support surface and apply it to an adhesive target surface. Several microstrip (MS) line structures are demonstrated to characterize the effect of stamp transfer on the RF performance of the printed circuits. The effects of printed vias on RF probe pads and shifts in the resonant frequencies of a Beatty standard line after transfer are considered and characterized using S-parameter measurements.

42 ENGINEERING↗

Examining the Performance of MIL-STD-188-110D Waveform 0 Against FBMC-SS Over Skywave HF Channels

This paper provides a comprehensive performance comparison between a current robust military waveform; namely, MIL-STD-188-110D, Waveform 0, and a filter bank multicarrier spread-spectrum (FBMC-SS) waveform proposed for communications through ionospheric/skywave HF channels. Waveform 0 is effectively a direct sequence spread spectrum waveform that uses Walsh multi-codes to enhance the information transmission rate. It may thus be referred to as Walsh-DSSS. FBMC-SS, on the other hand, makes use of filter banks to provide excellent performance when the received signal is subject to partial band interference. Successful application of FBMC-SS for communications across skywave HF channels has been previously demonstrated, both theoretically and through experimental work. However, very little has been done to contrast FBMC-SS against Walsh-DSSS. The goal of this paper is to first add new features to FBMC-SS to bring it on par with Walsh-DSSS. These features include: (i), introduction of multi-codes that achieve a comparable (or better) data rate to Walsh-DSSS; and (ii), addition of a scrambling step applied to the multi-codes to make the receiver detection robust against widely spread multipaths. With this established, in the second part of the paper, we examine the performance of the developed FBMC-SS against Walsh-DSSS when both are applied for communications across skywave HF channels. The two waveforms are compared both through a theoretical study and through experimental works across several skywave channels ranging from hundreds to thousands of kilometers.

42 ENGINEERING↗

Stationary quasi-breathers in monatomic FCC metals

The characteristics of quasi-breathers in monatomic fcc metals are investigated by the molecular dynamics method. The standard deviations of the frequencies of atoms constituting a breather from the fundamental frequency of oscillations are calculated. It is shown that the quasi-breather lifetime in the models under investigation depends on the initial excitation conditions as well as on the metal type.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NSR&D Program Fiscal Year (FY) 2015 Call for Proposals Mitigation of Seismic Risk at Nuclear Facilities using Seismic Isolation

Seismic isolation (SI) has the potential to drastically reduce seismic response of structures, systems, or components (SSCs) and therefore the risk associated with large seismic events (large seismic event could be defined as the design basis earthquake (DBE) and/or the beyond design basis earthquake (BDBE) depending on the site location). This would correspond to a potential increase in nuclear safety by minimizing the structural response and thus minimizing the risk of material release during large seismic events that have uncertainty associated with their magnitude and frequency. The national consensus standard America Society of Civil Engineers (ASCE) Standard 4, Seismic Analysis of Safety Related Nuclear Structures recently incorporated language and commentary for seismically isolating a large light water reactor or similar large nuclear structure. Some potential benefits of SI are: 1) substantially decoupling the SSC from the earthquake hazard thus decreasing risk of material release during large earthquakes, 2) cost savings for the facility and/or equipment, and 3) applicability to both nuclear (current and next generation) and high hazard non-nuclear facilities. Issue: To date no one has evaluated how the benefit of seismic risk reduction reduces cost to construct a nuclear facility. Objective: Use seismic probabilistic risk assessment (SPRA) to evaluate the reduction in seismic risk and estimate potential cost savings of seismic isolation of a generic nuclear facility. This project would leverage ongoing Idaho National Laboratory (INL) activities that are developing advanced (SPRA) methods using Nonlinear Soil-Structure Interaction (NLSSI) analysis. Technical Approach: The proposed study is intended to obtain an estimate on the reduction in seismic risk and construction cost that might be achieved by seismically isolating a nuclear facility. The nuclear facility is a representative pressurized water reactor building nuclear power plant (NPP) structure. Figure 1: Project activities The study will consider a representative NPP reinforced concrete reactor building and representative plant safety system. This study will leverage existing research and development (R&D) activities at INL. Figure 1 shows the proposed study steps with the steps in blue representing activities already funded at INL and the steps in purple the activities that would be funded under this proposal. The following results will be documented: 1) Comparison of seismic risk for the non-seismically isolated (non-SI) and seismically isolated (SI) NPP, and 2) an estimate of construction cost savings when implementing SI at the site of the generic NPP.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Mesoscale Processes of Scalable Synthesis Final Scientific/Technical Report

This is the final scientific and technical report for this award. Molecular dynamics (MD) is a powerful tool to study biomolecules at the nanoscale. One of its main limitations however is that such simulations typically require a timestep of 1 femtosecond while reactions and conformational changes typically happen on the time scale of 1 microsecond or more. This discrepancy severely restricts the impact of this method. We have developed a series of algorithms to mitigate this problem and allow predicting long-time scale events using much shorter simulations. The method is based on the concurrent adaptive sampling method. It consists in using probabilistic weights for trajectories and biasing the sampling such that rare but important trajectories, e.g., those that go over energy barriers and lead to relevant conformational changes in the molecule, are observed with much higher frequency that in a standard MD simulation. We will demonstrate below that this approach has been very successful. In collaboration with Jay Grate at PNNL we have applied this novel method to the study the triazine polymers, which can be con gured using different types of side chains in order to adopt different 3-dimensional structures. We have found novel stable con- formations and have analyzed the impact of side chain modifcations on the native folded shape of the polymer. Direct MD simulations would have been untractable for this problem. The method of replica exchange was also used successfully to calculate free energy profiles, in particular for cis-trans torsional angle changes with high energy barriers. Studying molecules at the atomistic scale is essential to design new molecules in chemical engineering, such as the triazine polymers developed by Grate, in material science to study the strength of metals for examples (e.g., dislocation dynamics), or in biochemistry to understand how proteins fold and how they interact with ligands (a key step in designing drugs). Although new hardware makes these simulations increasingly faster (e.g., GPU, Anton from DE Shaw Research), new algorithms are key to making these methods more tractable and increase their impact. At this point, because of limitations in modeling, one of the main techniques for advancing science remains to a large extent numerous and costly experiments. For exam- ple, when designing drug, where multiple variants must be screened, the ability to run tests on a computer rather than experimentally testing with high throughput methods thousands of compounds would represent a signi cant advance with broad benefits for the public at large.