Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUORIDE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

The application of laser induced predissociation fluorescence to the measurement of vibrational temperatures in a shock layer flow

Single shot spatially and spectrally resolved laser induced predissociation fluorescence measurements in a shock layer around a cylinder in a pulsed supersonic free stream are presented. Fluorescence signals were produced using the tuned output of an argon fluoride excimer laser to excite a mixture of rovibrational transitions in molecular oxygen. The signals produced along a line inside the shock layer were focussed onto a two dimensional detector coupled to a spectrometer, thus allowing spectral and spatial resolution of the fluorescence. In this way, it was possible to detect two fluorescence signals from two different transitions simultaneously, allowing the determination of vibrational temperatures without the need for calibration. However, to minimize problems associated with low signal to noise ratios, background subtraction and spatial averaging was required. The experimental measurements are compared with theoretical inviscid shock layer calculations for nonequilibrium air. A description of the strategies employed in these calculations is also provided.

Sutton, D. J.↗

Pressure dependence of the electro-optic response function in partially exposed polymer dispersed ferroelectric liquid crystals

Ferroelectric liquid crystals in a new configuration, termed partially exposed polymer dispersed ferroelectric liquid crystal (PEPDFLC), respond to external pressures and demonstrate pressure-induced electro-optic switching response. When the PEPDFLC thin film is sandwiched between two transparent conducting electrodes, one a glass plate and the other a flexible sheet such as polyvenylidene fluoride, the switching characteristics of the thin film are a function of the pressure applied to the flexible transparent electrode and the bias voltage across the electrodes. Response time measurements reveal a linear dependence of the change in electric field with external pressure.

Parmar, D. S.↗

Lanthanide-containing polyimides

The preparation of a variety of lanthanide-containing polyimide films is described, and results of their characterization are presented. The properties investigated include the glass transition temperature, thermooxidative stability, magnetic susceptibility, and electrical conductivity of the polymer. Films containing lanthanide chlorides, fluorides, and sulfides are flexible, but those containing lanthanide nitrates are extremely brittle. The addition of lanthanide acetates and acetylacetonates caused immediate gelation of two of the synthesis-mixture ingredients. It was found that, in general, the addition of lanthanide to the polyimide increases the density and glass transition temperature of the polymer but slightly decreases the thermooxidative stability.

Stoakley, D. M.↗

Intense laser beams; Proceedings of the Meeting, Los Angeles, CA, Jan. 23, 24, 1992

Various papers on intense laser beams are presented. Individual topics addressed include: novel methods of copper vapor laser excitation, UCLA IR FEL, lasing characteristics of a large-bore copper vapor laser (CVL), copper density measurement of a large-bore CVL, high-power XeCl excimer laser, solid state direct-drive circuit for pumping gas lasers, united energy model for FELs, intensity and frequency instabilities in double-mode CO2 lasers, comparison of output power stabilities of CO and CO2 lasers, increasing efficiency of sealed-off CO lasers, thermal effects in singlet delta oxygen generation, optical extraction from the chemical oxygen-iodine laser medium, generation and laser diagnostic analysis of bismuth fluoride. Also discussed are: high-Q resonator design for an HF overtone chemical lasers, improved coatings for HF overtone lasers, scaled atmospheric blooming experiment, simulation on producing conjugate field using deformable mirrors, paraxial theory of amplitude correction, potential capabilities of adaptive optical systems in the atmosphere, power beaming research at NASA, system evaluations of laser power beaming options, performance projections for laser beam power to space, independent assessment of laser power beaming options, removal of atmospheric CFCs by lasers, efficiency of vaporization cutting by CVL.

Wade, Richard C.↗

Master-Oscillator/Power-Amplifier Laser System

Master-oscillator/power-amplifier (MOPA) laser system operates in continuous-wave mode or in amplitude-modulation (e.g., pulse) mode by modulation of oscillator current. Power amplifier is laser-diode-pumped neodymium:yttrium lithium fluoride (Nd:YLF) laser; oscillator is laser diode. Offers relatively high efficiency and power. Because drive current to oscillator modulated, external electro-optical modulator not needed. Potential uses include free-space optical communications, coded laser ranging, and generation of high-power, mode-locked pulses.

Yu, Anthony W.↗

A combustion products analyzer for contingency use during thermodegradation events on spacecraft

The Toxicology Laboratory at JSC and Exidyne Instrumentation Technologies (EIT) have developed a prototype Combustion Products Analyzer (CPA) to monitor, in real time, combustion products from a thermodegradation event on board spacecraft. The CPA monitors the four gases that are the most hazardous compounds (based on the toxicity potential and quantity produced) likely to be released during thermodegradation of synthetic materials: hydrogen fluoride (HF), hydrogen chloride (HCl), hydrogen cyanide (HCN), and carbon monoxide (CO). The levels of these compounds serve as markers to assist toxicologists in determining when the cabin atmosphere is safe for the crew to breathe following the contingency event. The CPA is a hand-held, battery-operated instrument containing four electrochemical sensors, one for each target gas, and a pump for drawing air across the sensors. The sensors are unique in their small size and zero-g compatibility. The immobilized electrolytes in each sensor permit the instrument to function in space and eliminate the possibility of electrolye leaks. The sample inlet system is equipped with a particulate filter that prevents clogging from airborne particulate matter. The CPA has a large digital display for gas concentrations and warming signals for low flow and low battery conditions. The CPA has flown on 13 missions beginning with STS 41 in Oct. 1990. Current efforts include the development of a microprocessor, an improved carbon monoxide sensor, and a ground-based test program to evaluate the CPA during actual thermodegradation of selected materials.

Wilson, Steve↗

Production of electronic grade lunar silicon by disproportionation of silicon difluoride

Waldron has proposed to extract lunar silicon by sodium reduction of sodium fluorosilicate derived from reacting sodium fluoride with lunar silicon tetrafluoride. Silicon tetrafluoride is obtained by the action of hydrofluoric acid on lunar silicates. While these reactions are well understood, the resulting lunar silicon is not likely to meet electronic specifications of 5 nines purity. Dale and Margrave have shown that silicon difluoride can be obtained by the action of silicon tetrafluoride on elemental silicon at elevated temperatures (1100-1200 C) and low pressures (1-2 torr). The resulting silicon difluoride will then spontaneously disproportionate into hyperpure silicon and silicon tetrafluoride in vacuum at approximately 400 C. On its own merits, silicon difluoride polymerizes into a tough waxy solid in the temperature range from liquid nitrogen to about 100 C. It is the silicon analog of teflon. Silicon difluoride ignites in moist air but is stable under lunar surface conditions and may prove to be a valuable industrial material that is largely lunar derived for lunar surface applications. The most effective driver for lunar industrialization may be the prospects for industrial space solar power systems in orbit or on the moon that are built with lunar materials. Such systems would require large quantities of electronic grade silicon or compound semiconductors for photovoltaics and electronic controls. Since silicon is the most abundant semimetal in the silicate portion of any solar system rock (approximately 20 wt percent), lunar silicon production is bound to be an important process in such a solar power project. The lunar silicon extraction process is discussed.

Agosto, William N.↗

Laboratory studies of low temperature rate coefficients: The atmospheric chemistry of the outer planets

The objectives are to measure laboratory rate coefficients for key reactions of hydrocarbon molecules and radicals at low temperatures, which are relevant to the atmospheric photochemistry of Saturn, Jupiter, and Titan. Upcoming NASA planetary missions, such as Cassini, will probe the atmosphere of Titan in more detail, offering an excellent opportunity to test kinetic models and to establish fiducial standards for using kinetic models to interpret various parameters of the outer planets. Accurate low temperature kinetic data, which are presently lacking, may require crucial revisions to the rates of formation and destruction and are of utmost importance to the success of these efforts. In this program, several key reactions of ethynyl radicals (C2H) with acetylene (C2H2), methane (CH4), and oxygen (O2), down to temperatures of 170 K were successfully investigated. The experimental apparatus developed in our laboratory for measuring reaction kinetics at low temperatures consists of a laser photolysis/infrared probe laser setup. The rate measurements are carried out as a function of (low) temperature with a transverse flow cell designed specifically for these studies. A 193 nm argon fluoride pulsed excimer laser is used to photolyze a suitable precursor molecule, such as acetylene to produce C2H, and a high resolution, tunable infrared F-center laser (2.3-3.35 mu m) probes the transient concentrations of the radical species directly in absorption to extract the kinetic rate coefficients.

Leone, Stephen R.↗

Transparent conducting thin films for spacecraft applications

Transparent conductive thin films are required for a variety of optoelectronic applications: automotive and aircraft windows, and solar cells for space applications. Transparent conductive coatings of indium-tin-oxide (ITO)-magnesium fluoride (MgF2) and aluminum doped zinc oxide (AZO) at several dopant levels are investigated for electrical resistivity (sheet resistance), carrier concentration, optical properties, and atomic oxygen durability. The sheet resistance values of ITO-MgF2 range from 10(exp 2) to 10(exp 11) ohms/square, with transmittance of 75 to 86 percent. The AZO films sheet resistances range from 10(exp 7) to 10(exp 11) ohms/square with transmittances from 84 to 91 percent. It was found that in general, with respect to the optical properties, the zinc oxide (ZnO), AZO, and the high MgF2 content ITO-MgF2 samples, were all durable to atomic oxygen plasma, while the low MgF2 content of ITO-MgF2 samples were not durable to atomic oxygen plasma exposure.

Perez-Davis, Marla E.↗

Active vibration damping using smart material

We consider the modeling and active damping of an elastic beam using distributed actuators and sensors. The piezoelectric ceramic material (PZT) is used to build the actuator. The sensor is made of the piezoelectric polymer polyvinylidene fluoride (PVDF). These materials are glued on both sides of the beam. For the simple clamped beam, the closed loop controller has been shown to be able to extract energy from the beam. The shape of the actuator and its influence on the closed loop system performance are discussed. It is shown that it is possible to suppress the selected mode by choosing the appropriate actuator layout. It is also shown that by properly installing the sensor and determining the sensor shape we can further extract and manipulate the sensor signal for our control need.

Baras, John S.↗

VUV shock layer radiation in an arc-jet wind tunnel experiment

Measurements were made of the radiating gas cap of a blunt body in a NASA-Ames 20 MW arc-jet wind tunnel. The test gas was air. Spectra of the flux incident on a small aperture centered at the stagnation region were obtained. A helium-cooled, magnesium fluoride window transmitted the flux into an evacuated collimating system that focused the aperture onto the entrance slit of a spectrometer. Data were obtained with films and by photomultipliers. The spectral ranges covered were the vacuum ultraviolet, VUV, (120 nm to 200 nm) and the ultraviolet to near infrared (200 nm to 900 nm) with resolutions from 0.05 nm to 0.5 nm. This paper presents the preliminary VUV results from the experiment. Results from the 200 nm to 900 nm spectral range have been presented elsewhere. Representative spectral records from 120 nm to 200 nm are shown. The intense atomic oxygen and nitrogen lines which are of concern to hypersonic flight are measured. Carbon lines are are also seen. These results will be used to help develop and validate aerothermodynamic computational models of arc-jet wind tunnel performance and help to assess the importance of VUV heating to entering spacecraft.

Craig, Roger A.↗

Penetration of multiple thin films in micrometeorite capture cells

As part of a continuing effort to develop cosmic dust detectors/collectors for use in space, we performed a series of hypervelocity impact experiments on combined sensor/capture-cell assemblies using 10-200-micron-diameter glass projectiles and olivine crystals at velocities of 0.9-14.4 km/s. The design objective of the space-flight instrument is to measure the trajectories of individual particles with sufficient accuracy to permit identification of their parent bodies and to capture enough impactor material to allow chemical and isotopic analyses of samples returned to Earth. Three different multiple-film small-particle capture cell designs (0.1-100-micron-thick Al foils with approx. 10, 100, and 1800 micron spacing) were evaluated for their ability to capture impactor fragments and residue. Their performances were compared to two other types of capture cells, foil covered Ge crystals, and 0.50 and 0.120 g/cu cm aerogels. All capture cells were tested behind multifilm (1.4-6.0-micron-thick) polyvinylidene fluoride (PVDF) velocity/trajectory sensor devices. Several tests were also done without the PVDF sensors for comparison. The results of this study were reported by Simon in a comprehensive report in which the morphology of impacts and impactor residues in various types of capture cells after passage through two PVDF sensor films is discussed. Impactor fragments in selected capture cells from impacts at velocities up to 6.4 km/s were identified using scanning electron microscopy with energy dispersive spectroscopy (SEM/EDS).

Simon, Charles G.↗

PVDF flux/mass/velocity/trajectory systems and their applications in space

The current status of the University of Chicago Polyvinylidene Fluoride (PVDF) flux/mass/velocity/trajectory instrumentation is summarized. The particle response and thermal stability characteristics of pure PVDF and PVDF copolymer sensors are described, as well as the characteristics of specially constructed two-dimensional position-sensing PVDF sensors. The performance of high-flux systems and of velocity/trajectory systems using these sensors is discussed, and the objectives and designs of a PVDF velocity/trajectory dust instrument for launch on the Advanced Research and Global Observation Satellite (ARGOS) in 1995 and of a high-flux dust instrument for launch on the Cassini spacecraft to Saturn in 1997 are summarized.

Tuzzolino, Anthony J.↗

Effect of Microgravity on Material Undergoing Melting and Freezing: the TES Experiment

This experiment is the first to melt and freeze a high temperature thermal energy storage (TES) material under an extended duration of microgravity. It is one of a series to validate an analytical computer program that predicts void behavior of substances undergoing phase change under microgravity. Two flight experiments were launched in STS-62. The first, TES-1, containing lithium fluoride in an annular volume, performed flawlessly in the 22 hours of its operation. Results are reported in this paper. A software failure in TES-2 caused its shutdown after 4 seconds. A computer program, TESSIM, for thermal energy storage simulation is being developed to analyze the phenomena occurring within the TES containment vessel. The first order effects, particularly the surface tension forces, have been incorporated into TESSIM. TESSIM validation is based on two types of results. First is the temperature history of various points of the containment structure, and second, upon return from flight, the distribution of the TES material within the containment vessel following the last freeze cycle. The temperature data over the four cycles showed a repetition of results over the third and fourth cycles. This result is a confirmation that any initial conditions prior to the first cycle had been damped out by the third cycle. The TESSIM simulation showed a close comparison with the flight data. The solidified TES material distribution within the containment vessel was obtained by a tomography imaging process. The frozen material was concentrated toward the colder end of the annular volume. The TESSIM prediction showed the same pattern. With the general agreement of TESSIM and the data, a computerized visual representation can be shown which accurately shows the movement and behavior of the void during the entire freezing and melting cycles.

Namkoong, David↗

Effects of the LDEF orbital environment on the reflectance of optical mirror materials

Specimens of eight different optical mirror materials were flown in low earth orbit as part of the Long Duration Exposure Facility (LDEF) manifest to determine their ability to withstand exposure to the residual atomic oxygen and other environmental effects at those altitudes. Optical thin films of aluminum, gold, iridium, osmium, platinum, magnesium fluoride-overcoated aluminum and reactively deposited, silicon monoxide-protected aluminum, all of which were vacuum deposited on polished fused silica substrates, were included as part of Experiment S0010, Exposure of Spacecraft Coatings. Two specimens of polished, chemical vapor deposited (CVD) silicon carbide were installed in sites available in Experiment A0114, Interaction of Atomic Oxygen with Solid Surfaces at Orbital Altitudes, which included trays in two of the spacecraft bays, one on the leading edge and the other on the trailing edge. One of the silicon carbide samples was located in each of these trays. This paper will compare specular reflectance data from the preflight and postflight measurements made on each of these samples and attempt to explain the changes in light of the specific environments to which the experiments were exposed.

Herzig, Howard↗

The orbital debris detector consortium: Suppliers of instruments for in-situ measurements of small-particles in the space environment

Industry and university participants have joined together to form the IMPA:Ct consortium (In-situ Monitors of the Particulate Ambient: Circumterrestrial) which offers a broad range of flight qualified instruments for monitoring the small particle (0.1 micron to 10 cm) environment in space. Instruments are available in 12 months or less at costs ranging from 0.5 to 1.5 million dollars (US) for the total program. Detector technologies represented by these groups are: impact-induced capacitor-discharge (MOS, metal-oxide-silicon), cratering or penetration of electroactive thin film (polyvinylidene fluoride (PVDF)), impact-plasma detection, acoustic detection, CCD tracking of optical scatter of sunlight, and photodiode detection of optical scatter of laser light. The operational characteristics, general spacecraft interface and resource requirements (mass/power/telemetry), cost and delivery schedules, and points of contact for seven different instruments are presented.

Simon, C. G.↗

The millimeter-wave spectrum of the CaF radical (X(sup 2)Sigma(+))

The pure rotational spectrum of the CaF radical has been measured in the laboratory using millimeter/sub-mm direct absorption spectroscopy. Fourteen rotational transitions have been detected originating in the v = 0 mode of the species. Rotational lines of the vibrationally excited v = 1, 2, and 3 states have also been observed. Spin-rotation splittings, as well as hyperfine interactions arising from the nuclear spin of the fluorine atom, were resolved in the CaF spectra. Rotational, fine-structure, and in some cases, hyperfine parameters were determined for the various vibrational modes of the molecule from a nonlinear least-squares fit to the data, using a (sup 2)Sigma Hamiltonian, and are in agreement with past measurements. The newly measured rest frequencies for CaF, which are accurate to at least + or - 100 kHz, will enable astronomical searches to be conducted for the molecule in interstellar and circumstellar gas. Given the recent detection of AlF in IRC + 10216, metal fluoride species may be more abundant than previously thought.

Anderson, M. A.↗

Storing Fluorine In Graphitelike Carbon Fibers

Fluorine stored in graphite or graphitelike carbon fibers for later release and/or use in chemical reactions. Storage in carbon fibers eliminates difficulty and risk of using high-pressure tanks and pipes to hold corrosive gas. Storage in carbon fibers makes fluorine more readily accessible than does storage as constituent of metal fluoride. Carbon fibers heated to release stored fluorine, which draws away to vessel where reacts with material to be fluorinated, possibly at temperature other than release temperature. Alternatively, material to be fluorinated mixed or otherwise placed in contact with fibers and entire mass heated to or beyond release temperature.

Hung, Ching-Cheh↗