Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FAST NEUTRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

An Experimental Feasibility Study on Applying Neutron Tomography to Encapsulated Spent Nuclear Fuel - 20050

Visual inspection makes easier to ensure the integrity and safety of spent nuclear fuel (SNF) than any classical techniques. Various classical techniques have been applied but there are no reliable methods to qualitatively and quantitatively verify spent fuel in dry storage. Thus, the present authors have developed the prototype safeguards apparatus for dry storage employing the array of He-4 gas scintillation detectors (S670E, Arktis Radiation Detectors Ltd., Switzerland), newly designed to simultaneously measure thermal and fast neutrons without any moderators. The S670E detector has a cylindrical shape with a diameter of 52 mm and active length of 600 mm (total length: 875 mm). The detector is filled by He-4 gas with an approximate pressure of 180 bar for fast neutron detection, and its inner wall is coated by Li-6 for thermal neutron detection. The scintillation lights generated via Li-6 nuclear reaction and elastic scattering are collected by 24 SiPMs linearly paired at the center of the detector. The detector delivers a TTL (Transistor-Transistor Logic) output for pulse readout and UART (Universal Asynchronous Receiver Transmitter) for device control. In order to assess feasibility of the apparatus, an experimental system has been designed, built, and optimized via computational studies. Cf-252 neutron sources and linearly arrayed detectors, working as a single detector, were occupied for this study due to the difficulties in working with SNF. The laboratory scale cask (diameter: 0.67 m, height: 1.5 m), minimized by a factor of 10 compared to the actual thickness of a commercial TN-32 cask, was also manufactured. The detector array was designed to rotate the lab-scale cask and obtain 36 image profiles at every 10 degrees. All profiles were aligned in single frame image called a sinogram, and the cross-sectional image was then fabricated by the inverse radon transform algorithm. These experiments have been repeated with different configurations and numbers of sources. Some gamma-ray sources were also measured with neutron sources in order to distinguish between neutron and gamma-ray pulses. Basically, a He-4 detector is designed to run on Linux OS so it is difficult to directly apply to Windows-based equipment widely used in S. Korea. Therefore, a new data acquisition board working on Windows OS was designed and built. The board mainly consists of FPGA (Field Programmable Gate Array) and SoC (System on Chip) for TTL pulse readout, sorting measured data, and transferring data to a user interface. In conclusion, the tomographic system at lab-scale has shown considerable potential to detect a partial or gross defect of encapsulated assemblies in dry storage. Next steps of this study will be to 1) repeatedly carry out experiments to demonstrate scientific reliability and validity, and 2) numerically integrate signals with weight factors to enhance the image quality since the suggested system based on passive interrogation method requires longer measurement time. Finally, the system will apply to a commercial dry storage phased out soon in S. Korea. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Modeling of a Low-Background Spectroscopic Position-Sensitive Neutron Detector

A new low-background spectroscopic direction-sensitive neutron detector that would allow one to reduce the neutron background component in passive and active neutron detection techniques is proposed. The detector is based on thermal neutron detectors surrounded by a fast neutron scintillation detector, which serves at the same time as a neutron moderator. Direction sensitivity is achieved by coincidence/anticoincidence analysis between different parts of the scintillator. Results of mathematical modeling of several detector configurations are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical response to M. Worrall et al. Published in Annals of Nuclear Energy 207 (2024) 110731

M. Worrall et al. recently published a manuscript titled “Fast neutron irradiation capability in existing thermal test reactors” (Worrall, 2024) that summarizes an irradiation vehicle design that would boost the fast neutron flux in the Advanced Test Reactor (ATR) for testing of nonfuel materials in a neutron flux energy spectrum that is more representative of fast reactors. Here, the authors compare their design with a separate vehicle design that they conceived of that would be implemented within the High Flux Isotope Reactor (HFIR). They analyzed both designs and drew conclusions on the most realistic near-term options for shielded nonfuel material irradiations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Experimental uncertainty quantification using templates of expected measurement uncertainties for fast neutron-induced total, capture, and scattering cross sections

Careful experimental uncertainty quantification (UQ) is key for developing trustworthy evaluated nuclear data. Templates to account for missing or under-reported experimental uncertainties were recently developed by the covariance committee of Cross Section Evaluation Working Group (CSEWG). In this work, we illustrate the practical application and limitations of these templates for selected neutron-induced reactions, including (n, tot), (n, γ), and (n, xn) in the fast energy range, to illustrate their use in data analyses for nuclear data evaluations. We show that while the templates provide consistent framework, proper implementation still requires detailed knowledge of experimental conditions and careful treatment of nonlinear effects in cross section derivation. Case studies highlight how template-assisted UQ improves consistency with previous evaluations such as ENDF/B and reveals open challenges in propagating uncertainties across different energy regimes. The main contribution of this paper is to connect formal template recommendations with their use in practical evaluation workflows, clarifying both their benefits and current limitations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultra-Long-Life Fast Reactor Cores having Axial Blanket-Driver-Blanket Burnup Strategy with Thorium and PWR Spent Fuels

The sustainable energy over a long-term period can be supplied by ultra-long-life fast reactor cores that are designed by fully utilizing breeding by fast neutrons to be operated over several tens of years without refueling. But the fast reactor cores of this type usually have high positive coolant void reactivity worth resulted from the high TRU (Transuranics) contents in the high burnup, which can degrade the inherent safety through high positive coolant expansion reactivity coefficient. Recently, the authors have designed new small ultra-long-life cores that can be operated over 50{approx}60 EFPYs (Effective Full Power Years) and satisfy the self-controllability conditions under the unprotected accidents. The cores use axial blanket-driver-blanket configuration to achieve ultra-long operational cycle length where the fuel burnup propagates from the outer core to the inner core and from the axially central driver to the outer blanket regions. The objective of this work is to suggest the different design options with thorium addition and TRU and uranium from PWR spent fuels for effectively utilizing the large PWR spent fuel stocks and to analyze the performances of the cores. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of accelerator technologies for use in ADSS

Accelerator Driven Subcritical (ADS) fission is an interesting candidate basis for nuclear waste transmutation and for nuclear power generation. ADS can use either thorium or depleted uranium as fuel, operate below criticality, and consume rather than produce long-lived actinides. A case study with a hypothetical, but realistic nuclear core configuration is used to evaluate the performance requirements of the driver proton accelerator in terms of beam energy, beam current, duty factor, beam distribution delivered to the fission core, reliability, and capital and operating cost. Comparison between a CW IC and that of a SRF proton linac is evaluated. Future accelerator R&D required to improve each candidate accelerator design is discussed. ADS fission has interesting potential for electric power generation and also for destruction of long-lived actinide waste produced by conventional critical reactors. ADS systems offer several interesting advantages in comparison to critical reactors: (1) ADS provides greater flexibility for the composition and placement of fissile, fertile, or fission product waste within the core, and require less enrichment of fissile content; (2) The core can be operated with a reactivity k{sub eff} that cannot reach criticality by any failure mode; (3) When the beam is shut off fission ceases in the core; (4) Coupling the fast neutron spectrum of the spallation drive to fast core neutronics offers a basis for more complete burning of long-lived actinides; and (5) ADS designs can provide sufficient thermal mass that meltdown cannot occur from radioactive heat after fission is stopped. In order to drive a {approx}GW{sub e} fission core a CW proton beam of >700 MeV and {approx}15 MW beam power is required. A previous study of the accelerator performance required for ADS systems concluded that present accelerator performance is approaching those requirements, but accelerator system cost and reliability remain particular concerns. The obvious candidates for accelerators that can provide intense CW proton beams are isochronous cyclotrons (IC) and superconducting linacs. We have examined a case study using a hypothetical ADS core configuration to guide our thinking in evaluating those two accelerator technologies for use in ADS systems. Issues of accelerator power, multiplicity of accelerators, and options for core neutronics and fuel form are discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dosimetry in Thermal Neutron Irradiation Facility at BMRR

Radiation dosimetry for Neutron Capture Therapy (NCT) has been performed since 1959 at Thermal Neutron Irradiation Facility (TNIF) of the three-megawatt light-water cooled Brookhaven Medical Research Reactor (BMRR). In the early 1990s when more effective drug carriers were developed for NCT, in which the eye melanoma and brain tumors in rats were irradiated in situ, extensive clinical trials of small animals began using a focused thermal neutron beam. To improve the dosimetry at irradiation facility, a series of innovative designs and major modifications made to enhance the beam intensity and to ease the experimental sampling at BMRR were performed; including (1) in-core fuel addition to increase source strength and balance flux of neutrons towards two ports, (2) out of core moderator remodeling, done by replacing thicker D 2 O tanks at graphite-shutter interfacial areas, to expedite neutron thermalization, (3) beam shutter upgrade to reduce strayed neutrons and gamma dose, (4) beam collimator redesign to optimize the beam flux versus dose for animal treatment, (5) beam port shielding installation around the shutter opening area (lithium-6 enriched polyester-resin in boxes, attached with polyethylene plates) to reduce prompt gamma and fast neutron doses, (6) sample holder repositioning to optimize angle versus distance for a single organ or whole body irradiation, and (7) holder wall buildup with neutron reflector materials to increase dose and dose rate from scattered thermal neutrons. During the facility upgrade, reactor dosimetry was conducted using thermoluminescent dosimeters TLD for gamma dose estimate, using ion chambers to confirm fast neutron and gamma dose rate, and by the activation of gold-foils with and without cadmium-covers, for fast and thermal neutron flux determination. Based on the combined effect from the size and depth of tumor cells and the location and geometry of dosimeters, the measured flux from cadmium-difference method was 4 - 7 % lower than the statistical mean derived from the Monte-Carlo modeling (5% uncertainty). The dose rate measured by ion chambers was 6 - 10 % lower than the output tallies (7% uncertainty). The detailed dosimetry that was performed at the TNIF for the NCT will be described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluation of Neutron Reactions on Iron Isotopes for CIELO and ENDF/B-VIII.0

A new suite of evaluations for {sup 54,56,57,58}Fe has been developed in the framework of the CIELO international collaboration. New resolved resonance ranges were evaluated for {sup 54}Fe and {sup 57}Fe, while modifications were applied to resonances in {sup 56}Fe. The low energy part of the {sup 56}Fe file is almost totally based on measurements. At higher energies in {sup 56}Fe and in the whole fast neutron range for minor isotopes the evaluation consists of model predictions carefully adjusted to available experimental data. We also make use of the high quality and well experimentally-constrained dosimetry evaluations from the IRDFF library. Special attention was dedicated to the elastic angular distributions, which were found to affect results of the integral benchmarking. The new set of iron evaluations was developed in concert with other CIELO evaluations and they were tested together in the integral experiments before being adopted for the ENDF/B-VIII.0 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncollided Flux Techniques for Discrete-Ordinate Radiation Transport Solutions in Rattlesnake

One of the only real-time-resolved measurement tools used at the Transient Test Reactor (TREAT) is the fast-neutron hodoscope. The hodoscope was used for monitoring and measuring fuel motion during a transient pulse. The hodoscope is a line of sight detection and imaging system that provides both temporal and spatial resolution of fuel motion during transients, and in-place measurement of fuel distribution during and after transient experiments. However, the hodoscope relies on fast neutron streaming out of the reactor core, which provides a challenge to transient modeling and simulation. However, use of a first collision source approach can be used to overcome this shortcoming. Hence, the TREAT modeling and simulation team has initiated research to implement such capabilities in the neutron transport code Rattlesnake. This report reviews uncollided flux techniques (first and last collision methods) to be implemented in the Rattlesnake SN code in order to mitigate ray effects in modeling the TREAT reactor+hodoscope system. Angular discretization techniques (SN and PN) for the transport equation are notoriously poor at capturing effectively streaming effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Using Electronic Neutron Generators in Active Interrogation to Detect Shielded Fissionable Material

Experiments have been performed at Idaho National Laboratory to study methodology and instrumentation for performing neutron active interrogation die-away analyses for the purpose of detecting shielded fissionable material. Here we report initial work using a portable DT electronic neutron generator with a He-3 fast neutron detector to detect shielded fissionable material including >2 kg quantities of enriched uranium and plutonium. Measurements have been taken of bare material as well as of material hidden within a large plywood cube. Results from this work have demonstrated the efficacy of the die-away neutron measurement technique for quickly detecting the presence of special nuclear material hidden within plywood shields by analyzing the time dependent neutron signals in-between neutron generator pulses. Using a DT electronic neutron generator operating at 300 Hz with a yield of approximately 0.36 x 10**8 neutrons per second, 2.2 kg of enriched uranium hidden within a 0.60 m x 0.60 m x 0.70 m volume of plywood was positively detected with a measurement signal 2-sigma above the passive background within 1 second. Similarly, for a 500 second measurement period a lower detection limit of approaching the gram level could be expected with the same simple set-up.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INITIAL EVALUATION OF A PULSED WHITE SPECTRUM NEUTRON GENERATOR FOR EXPLOSIVE DETECTION

Successful explosive material detection in luggage and similar sized containers is acritical issue in securing the safety of all airline passengers. Tensor Technology Inc. has recently developed a methodology that will detect explosive compounds with pulsed fast neutron transmission spectroscopy. In this scheme, tritium beams will be used to generate neutrons with a broad energy spectrum as governed by the T(t,2n)4He fission reaction that produces 0-9 MeV neutrons. Lawrence Berkeley National Laboratory (LBNL), in collaboration with Tensor Technology Inc., has designedand fabricated a pulsed white-spectrum neutron source for this application. The specifications of the neutron source are demanding and stringent due to the requirements of high yield and fast pulsing neutron emission, and sealed tube, tritium operation. In a unique co-axial geometry, the ion source uses ten parallel rf induction antennas to externally couple power into a toroidal discharge chamber. There are 20 ion beam extraction slits and 3 concentric electrode rings to shape and accelerate the ion beam into a titanium cone target. Fast neutron pulses are created by using a set ofparallel-plate deflectors switching between +-1500 volts and deflecting the ion beams across a narrow slit. The generator is expected to achieve 5 ns neutron pulses at tritium ion beam energies between 80 - 120 kV. First experiments demonstrated ion source operation and successful beam pulsing.

43 PARTICLE ACCELERATORS↗

Dopant, coating, and grating effects in silica optical fibers under extreme neutron irradiation

Radiation effects on fiber Bragg gratings (FBGs) have been studied but data gaps related to the effects of displacement damage resulting from high fast neutron fluence remain. In this work, Type-I and Type-II FBGs inscribed in optical fibers with various core dopants (Ge and F) and fiber coatings (acrylate, polyimide) were monitored in situ during 75 days of neutron irradiation to a peak fast (>0.1 MeV) neutron fluence of 3 X 10 21 n fast /cm 2 . Further, the reflected intensity of the Type-I FBGs inscribed in a Ge-doped core fiber decreased by > 30 dB within 7 h of irradiation (10 19 n fast /cm 2 ), whereas Type-II FBGs inscribed in a pure silica core fiber eventually approached >40 dB attenuation after accumulating a fast neutron fluence on the order of 10 20 n fast /cm 2 . Type-II FBGs inscribed in F-doped core fiber improved stability: the attenuation approached an equilibrium value in the range of 10 to 20 dB.

47 OTHER INSTRUMENTATION↗

FY09 Advanced Instrumentation and Active Interrogation Research for Safeguards

Multiple small-scale projects have been undertaken to investigate advanced instrumentation solutions for safeguard measurement challenges associated with advanced fuel cycle facilities and next-generation fuel reprocessing installations. These activities are in support of the U.S. Department of Energy's Fuel Cycle Research and Development program and its Materials Protection, Accounting, and Control for Transmutation (MPACT) campaign. 1) Work was performed in a collaboration with the University of Michigan (Prof. Sara Pozzi, co-PI) to investigate the use of liquid-scintillator radiation detectors for assaying mixed-oxide (MOX) fuel, to characterize its composition and to develop advanced digital pulse-shape discrimination algorithms for performing time-correlation measurements in the MOX fuel environment. This work included both simulations and experiments and has shown that these techniques may provide a valuable approach for use within advanced safeguard measurement scenarios. 2) Work was conducted in a collaboration with Oak Ridge National Laboratory (Dr. Paul Hausladen, co-PI) to evaluate the strengths and weaknesses of the fast-neutron coded-aperture imaging technique for locating and characterizing fissile material, and as a tool for performing hold-up measurements in fissile material handling facilities. This work involved experiments at Idaho National Laboratory, using MOX fuel and uranium metal, in both passive and active interrogation configurations. A complete analysis has not yet been completed but preliminary results suggest several potential uses for the fast neutron imaging technique. 3) Work was carried out to identify measurement approaches for determining nitric acid concentration in the range of 1 – 4 M and beyond. This work included laboratory measurements to investigate the suitability of prompt-gamma neutron activation analysis for this measurement and product reviews of other commercial solutions. Ultrasonic density analysis appears to be the best candidate technology for determining nitric acid concentrations but the PGNAA approach may also be applicable. 4) Work was also carried out to begin investigating the use of remote UV imaging to detect air-ionization induced by alpha particle emission from plutonium. This approach has been shown elsewhere as a useful tool for detecting and quantifying plutonium contamination and has the potential of providing a unique and powerful approach for quantifying hold-up in reprocessing facilities. Based on these simple scoping experiments the potential far-reaching capabilities of the measurement are clear.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Gated Liquid-Scintillator-Based Neutron Detector for Fast-Ignitor Experiments and Down-Scattered Neutron Measurements

The detection of neutrons in fast-ignitor experiments or down-scattered neutrons in inertial fusion experiments is very challenging since it requires the neutron detection system to recover within 10–100 ns from a high background orders of magnitude stronger than the signal of interest. The background is either the hard x-ray emission from short-pulse laser target interactions for the fast-ignitor experiments or the primary neutron signal for the down-scattered neutrons. A liquid-scintillator detector has been developed using a gated photomultiplier that suppresses the background signal and eliminates the afterglow present in conventional plastic scintillators.

Stoeckl, C↗

Preliminary Modeling to Support the TREAT Hodoscope System for Fuel Motion Monitoring

Fuel motion is monitored in real time at the Transient Reactor Test Facility (TREAT) using a direct-viewing hodoscope that monitors fast neutrons emitted from test fuel undergoing fission during transients. The hodoscope system is now being refurbished, after over twenty years, to once again support research and development activities examining the survival and failure modes of advanced nuclear reactor fuel systems under accident conditions. An im-portant part of this activity is the development of high-fidelity modeling tools to predict the hodoscope's response to different fuel systems, in different test vehicles, throughout different transient cycles. Initial work has involved the collection of archival data related to how the hodoscope currently at TREAT was manufactured and installed, and the use of this data to create a preliminary radiation transport model using MCNP6. This model is now undergoing refinement to improve its fidelity and to permit its integration with other tools under development to model TREAT transients. The model will be used to study how fast-neutrons measured in the hodoscope's detectors relate to the fission of nuclear material in a test vehicle as a function of location within the vehicle and reactor power. The goal is to develop a time-dependent coupling factor that will relate the measured data to the fuel mass present within each pixel of the hodoscope's field of view. This paper will present the current status of the TREAT hodoscope refurbishment program and modeling activities related to interpreting hodoscope data and inferring fuel motion during transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 235 U

Two isotopically-characterized targets of high-purity (99.84±0.03%) 235 U-oxide and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva critical assembly at the National Criticality Experiments Research Center. Following irradiation, the fissioned targets were counted with a broad-energy germanium detector. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total fission values were then used to measure the fission yields of 21 fission products with half-lives between 636 and 119,700 seconds. Mean values of seventeen of the measured fission products fell within the 95% confidence level of the Evaluated Nuclear Data Files VII.1/b (ENDF/B-VII.1) using the larger of the two uncertainties: 84g Br, 89 Rb, 91 Sr, 93 Y, 97 Zr, 101 Mo, 105 Ru, 128 Sn, 129 Sb, 130g Sb, 131 Sb, 131m Te, 133 I, 135 I, 141 Ba, 142 Ba, and 142 La. Seven isotopes were measured to better precision than is listed in the ENDF/B-VII.1 database: 89 Rb, 93 Y, 128 Sn, 129 Sb, 130g Sb, 131m Te, and 133 I. Four of the measured isotopes were found to be statistically different from the ENDF/B-VII.1 database: 94 Y, 134 Te, 134 I, and 138 Xe. Two of the isotopic analyses conducted in this paper fit the parent and daughter data simultaneously. The parent-daughter pairs measured in this way were the 134 Te/I and 142 Ba/La pairs. The fission yield results obtained in this way are unique, especially for 134 I, because the parent and daughter half-lives are so close. Here, given the limited number of direct measurements of the 134 Te/I pair from fast neutron induced fission and the seemingly high estimate for 134 Te from previous work, it is likely that the value in this paper is more accurate; however, additional measurements of this pair are needed to validate this assertion.

42 ENGINEERING↗