Notes on the Variety of Multipactor Patterns
The experimental results on multipactor often are not in a good agreement with theoretical predictions and numerical simulations. The experimental results can noticeably vary from test to test even in the same geometry of electrodes, depending on the material they made of and condition of their surfaces, i.e., secondary emission properties. On the other hand, an actual secondary emission yield (SEY) of electrode material is never known a priory in the experiments. In practice, the SEY data for given material used for multipactor evaluation are obtained in specialized measurements. A difference between actual and tabulated SEY of material may result in a disagreement between pre-dictions and measurements. In this work the impact of the basic SEY characteristic variations on the multipactor dynamics in a variety of coaxial and rectangular waveguides is studied. The study was performed numerically with the use of CST Particle Studio.