Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Simulation Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Spectra of clinical CT scanners using a portable Compton spectrometer

Purpose: Spectral information of the output of x-ray tubes in (dual source) computer tomography (CT) scanners can be used to improve the conversion of CT numbers to proton stopping power and can be used to advantage in CT scanner quality assurance. The purpose of this study is to design, validate, and apply a compact portable Compton spectrometer that was constructed to accurately measure x-ray spectra of CT scanners. Methods: In the design of the Compton spectrometer, the shielding materials were carefully chosen and positioned to reduce background by x-ray fluorescence from the materials used. The spectrum of Compton scattered x-rays alters from the original source spectrum due to various physical processes. Reconstruction of the original x-ray spectrum from the Compton scattered spectrum is based on Monte Carlo simulations of the processes involved. This reconstruction is validated by comparing directly and indirectly measured spectra of a mobile x-ray tube. The Compton spectrometer is assessed in a clinical setting by measuring x-ray spectra at various tube voltages of three different medical CT scanner x-ray tubes. Results: The directly and indirectly measured spectra are in good agreement (their ratio being 0.99) thereby validating the reconstruction method. The measured spectra of the medical CT scanners are consistent with theoretical spectra and spectra obtained from the x-ray tube manufacturer. Conclusions: A Compton spectrometer has been successfully designed, constructed, validated, and applied in the measurement of x-ray spectra of CT scanners. These measurements show that our compact Compton spectrometer can be rapidly set-up using the alignment lasers of the CT scanner, thereby enabling its use in commissioning, troubleshooting, and, e.g., annual performance check-ups of CT scanners.

07 ISOTOPE AND RADIATION SOURCES↗

Mutual shadowing and directional reflectance of a rough surface - A geometric-optical model

A Monte Carlo simulation of mutual shadowing effects is presented. Results of these simulations and the corresponding modeling efforts are also presented. Simulation results show that the assumption that all illumination shadows will preferentially occupy the lower surface of crowns is not realistic enough and may cause a considerable discrepancy between modeled results and simulation. Therefore, the model was modified by making the probability that a point on the surface of the crown is illuminated to be a function of height from the base of the crown, while still accounting for the fact that at the hotspot the probability that all illuminated points are viewed is one. With this change, modeled results show better agreement with the simulations.

Li, Xiaowen↗

Investigation of Direct Force Control for Planetary Aerocapture at Neptune

In this work, a direct force control numerical predictor-corrector guidance architecture is developed to enable Neptune aerocapture using flight-heritage blunt body aeroshells. A linear aerodynamics model is formulated for a Mars Science Laboratory-derived aeroshell. The application of calculus of variations shows that the optimal angle of attack and side-slip angle control laws are bang-bang. A closed-loop numerical predictor-corrector direct force control guidance algorithm is developed and numerically simulated using the Program to Optimize Simulated Trajectories II. The Monte Carlo simulated trajectories are demonstrated to be robust to the modeled dispersions in aerodynamics, atmospheric density, and entry state. An aerocapture technology trade study demonstrates that blunt body direct force control aerocapture enables similar performance as slender body bank angle control but halves the peak g-loading.

Deshmukh, Rohan G.↗

Poster — Thur Eve — 47: Monte Carlo Simulation of Scp, Sc and Sp

The in-water output ratio (Scp), in-air output ratio (Sc), and phantom scattering factor (Sp) are important parameters for radiotherapy dose calculation. Experimentally, Scp is obtained by measuring the dose rate ratio in water phantom, and Sc the water Kerma rate ratio in air. There is no method that allows direct measurement of Sp. Monte Carlo (MC) method has been used to simulate Scp and Sc in literatures, similar to experimental setup, but no MC direct simulation of Sp available yet to the best of our knowledge. We propose in this report a method of performing direct MC simulation of Sp. Starting from the definition, we derived that Sp of a clinical photon beam can be approximated by the ratio of the dose rates contributed from the primary beam for a given field size to the reference field size. Since only the primary beam is used, any Linac head scattering should be excluded from the simulation, which can be realized by using the incident electron as a scoring parameter for MU. We performed MC simulations for Scp, Sc and Sp. Scp matches well with golden beam data. Sp obtained by the proposed method agrees well with what is obtained using the traditional method, Sp=Scp/Sc. Since the smaller the field size, the more the primary beam dominates, our Sp simulation method is accurate for small field. By analyzing the calculated data, we found that this method can be used with no problem for large fields. The difference it introduced is clinically insignificant.

07 ISOTOPE AND RADIATION SOURCES↗

Auxiliary-Field Quantum Monte Carlo Simulations of Strongly-Correlated Molecules and Solids

We propose a method of implementing projected wave functions for second-quantized auxiliary-field quantum Monte Carlo (AFQMC) techniques. The method is based on expressing the two-body projector as one-body terms coupled to binary Ising fields. To benchmark the method, we choose to study the two-dimensional (2D) one-band Hubbard model with repulsive interactions using the constrained-path MC (CPMC). The CPMC uses a trial wave function to guide the random walks so that the so-called fermion sign problem can be eliminated. The trial wave function also serves as the importance function in Monte Carlo sampling. As such, the quality of the trial wave function has a direct impact to the efficiency and accuracy of the simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AN ANALYSIS OF CHANDRA DEEP FOLLOW-UP GAMMA-RAY BURSTS: IMPLICATIONS FOR OFF-AXIS JETS

We present a sample of 27 gamma-ray bursts (GRBs) with detailed Swift light curves supplemented by late-time Chandra observations. To answer the missing jet-break problem in general, we develop a numerical-simulation-based model that can be directly fit to the data using Monte Carlo methods. Our numerical model takes into account all the factors that can shape a jet break: (i) lateral expansion, (ii) edge effects, and (iii) off-axis effects. Our results provide improved fits to the light curves and constraints on physical parameters. More importantly, our results suggest that off-axis effects are important and must be included in interpretations of GRB jet breaks.

79 ASTRONOMY AND ASTROPHYSICS↗

A backward Monte-Carlo method for time-dependent runaway electron simulations

Kinetic descriptions of runaway electrons (REs) are usually based on Fokker-Planck models that determine the probability distribution function of REs in 2-dimensional momentum space. Despite the simplification involved, the Fokker-Planck equation can rarely be solved analytically and direct numerical approaches [e.g., continuum and particle-based Monte Carlo (MC)] can be time consuming, especially in the computation of asymptotic-type observables including the runaway probability, the slowing-down and runaway mean times, and the energy limit probability. In this study, we present a novel backward MC approach to these problems based on backward stochastic differential equations that describe the dynamics of the runaway probability by means of the Feynman-Kac theory. The key ingredient of the backward MC algorithm is to place all the particles in a runaway state and simulate them backward from the terminal time to the initial time. As such, our approach can provide much faster convergence than direct MC methods (by significantly reducing the number of particles required to achieve a prescribed accuracy) while at the same time maintaining the advantages of particle-based methods (compared to continuum approaches). The proposed algorithm is unconditionally stable and can be parallelized as easy as the direct MC method, and its extension to dimensions higher than two is straightforward, thus paving the way for conducting large-scale RE simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvement of dose distribution in breast radiotherapy using a reversible transverse magnetic field Linac-MR unit

Purpose: To investigate the improvement in dose distribution in tangential breast radiotherapy using a reversible transverse magnetic field that maintains the same direction of Lorentz force between two fields. The investigation has a potential application in future Linac-MR units. Methods: Computed tomography images of four patients and magnetic fields of 0.25–1.5 Tesla (T) were used for Monte Carlo simulation. Two patients had intact breast while the other two had mastectomy. Simulations of planning and chest wall irradiation were similar to the actual clinical process. The direction of superior-inferior magnetic field for the medial treatment beam was reversed for the lateral beam. Results: For the ipsilateral lung and heart mean doses were reduced by a mean (range) of 45.8% (27.6%–58.6%) and 26.0% (20.2%–38.9%), respectively, depending on various treatment plan setups. The mean V{sub 20} for ipsilateral lung was reduced by 55.0% (43.6%–77.3%). In addition acceptable results were shown after simulation of 0.25 T magnetic field demonstrated in dose-volume reductions of the heart, ipsilateral lung, and noninvolved skin. Conclusions: Applying a reversible magnetic field during breast radiotherapy, not only reduces the dose to the lung and heart but also produces a sharp drop dose volume histogram for planning target volume, because of bending of the path of secondary charged particles toward the chest wall by the Lorentz force. The simulations have shown that use of the magnetic field at 1.5 T is not feasible for clinical applications due to the increase of ipsilateral chest wall skin dose in comparison to the conventional planning while 0.25 T is suitable for all patients due to dose reduction to the chest wall skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessing the difficulty of capturing the distribution function of neutrinos in neutron star merger simulations

The collision of two neutron stars is a rich source of information about nuclear physics. In particular, the kilonova signal following a merger can help us elucidate the role of neutron stars in nucleosynthesis, and informs us about the properties of matter above nuclear saturation. Approximate modeling of neutrinos remains an important limitation to our ability to make predictions for these observables. Part of the problem is the fermionic nature of neutrinos. By the exclusion principle, the expected value 𝑓 𝜈 for the number of neutrinos in a quantum state is at most 1. Any process producing neutrinos is suppressed by a blocking factor (1 −𝑓 𝜈 ). Recent simulations focused on neutrino physics mostly use a gray two-moment scheme to evolve neutrinos. This evolves integrals of 𝑓 𝜈 over momentum space, preventing direct calculations of blocking factors. Monte Carlo methods may be an attractive alternative, providing access to the full distribution of neutrinos. Their current implementation is, however, inadequate to estimate 𝑓 𝜈 : in our most recent simulations, a single Monte Carlo packet causes, in the worst cases, estimates of 𝑓 𝜈 to jump from 𝑓 𝜈 =0 to 𝑓 𝜈 ∼10 5 . While this is concerning, this brazen violation of the fermionic nature of neutrinos has been largely inconsequential, as the interactions used in simulations avoid direct calculations of 𝑓 𝜈 . We are, however, reaching a level of modeling at which this problem can no longer be ignored. Here, we discuss the relatively simple origin of this issue. We then show that very rough estimates of 𝑓 𝜈 can in theory be obtained in merger simulations, but that they will require a combination of unintuitive weighting schemes for Monte Carlo packets and smoothing of the neutrino distribution at coarser resolution than what the merger simulation uses.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo Simulation of the Conversion X-Rays from the Electron Beam of PFMA-3

PFMA-3, a dense Plasma Focus device, is being optimized as an X-ray generator. X-rays are obtained from the conversion of the electron beam emitted in the backward direction and driven to impinge on a 50 {mu}m brass foil. Monte Carlo simulations of the X-ray emission have been conducted with MCNPX. The electron spectrum had been determined experimentally and is used in the present work as input to the simulations. Dose to the brass foil has been determined both from simulations and from measurements with a thermographic camera, and the two results are found in excellent agreement, thus validating further the electron spectrum assumed as well as the simulation set-up. X-ray emission has been predicted both from bremsstrahlung and from characteristic lines. The spectrum has been found to be comprised of two components of which the one at higher energy, 30 divide 70 keV, is most useful for IORT applications. The results are necessary to estimate penetration in and dose to Standard Human Tissue.

43 PARTICLE ACCELERATORS↗

An Investigation of Parallel Programming Techniques Applied to Monte Carlo Simulations for Post-Flight Reconstruction of Spacecraft Trajectory

Parallelizing software to execute on multi-core central processing units (CPUs) and graphics processing units (GPUs) can be challenging. For some fields outside of Computer Science, this transition comes with new issues. For example, memory limitations can require modifications to code not initially developed to run on GPUs. This work applies the Open Multi-Processing (OpenMP) and Open Accelerators (OpenACC) directive-based parallelization strategies on a Monte Carlo simulation approach for trajectory reconstruction enabling it to run on multi-core CPUs and GPUs. Large matrix operations are the most common use of GPUs, which are not present in this algorithm; however, the natural parallelism of independent trajectories in Monte Carlo simulations is exploited. Benchmarking data are presented comparing execution times of the software for single-thread CPUs, multi-thread CPUs with OpenMP, and multi-thread GPUs using OpenACC. These data were collected using nodes with Intel® Xeon® E5-2670 (Sandy Bridge) CPUs enhanced with NVIDIA® Tesla® K40 GPUs on the Pleiades Supercomputer cluster at the National Aeronautics and Space Administration (NASA) Ames Research Center (ARC) and a local Intel® Xeon Phi™ node at NASA Langley Research Center (LaRC).

Williams, R. Anthony↗

Electron knock-on damage in hexagonal boron nitride monolayers

We combine first-principles molecular-dynamics simulations with high-resolution transmission electron microscopy experiments to draw a detailed microscopic picture of irradiation effects in hexagonal boron nitride (h-BN) monolayers. We determine the displacement threshold energies for boron and nitrogen atoms in h-BN, which differ significantly from the tight-binding estimates found in the literature and remove ambiguity from the interpretation of the experimental results. We further develop a kinetic Monte Carlo model which allows to extend the simulations to macroscopic time scales and make a direct comparison between theory and experiments. Our results provide a comprehensive picture of the response of h-BN nanostructures to electron irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental and Simulated Characterization of a Beam Shaping Assembly for Accelerator- Based Boron Neutron Capture Therapy (AB-BNCT)

In the frame of the construction of a Tandem Electrostatic Quadrupole Accelerator facility devoted to the Accelerator-Based Boron Neutron Capture Therapy, a Beam Shaping Assembly has been characterized by means of Monte-Carlo simulations and measurements. The neutrons were generated via the {sup 7}Li(p, n){sup 7}Be reaction by irradiating a thick LiF target with a 2.3 MeV proton beam delivered by the TANDAR accelerator at CNEA. The emerging neutron flux was measured by means of activation foils while the beam quality and directionality was evaluated by means of Monte Carlo simulations. The parameters show compliance with those suggested by IAEA. Finally, an improvement adding a beam collimator has been evaluated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte-Carlo Simulation of Radiation Track Structure and Calculation of Dose Deposition in Nanovolumes

INTRODUCTION: The radiation track structure is of crucial importance to understand radiation damage to molecules and subsequent biological effects. Of a particular importance in radiobiology is the induction of double-strand breaks (DSBs) by ionizing radiation, which are caused by clusters of lesions in DNA, and oxidative damage to cellular constituents leading to aberrant signaling cascades. DSB can be visualized within cell nuclei with gamma-H2AX experiments. MATERIAL AND METHODS: In DSB induction models, the DSB probability is usually calculated by the local dose obtained from a radial dose profile of HZE tracks. In this work, the local dose imparted by HZE ions is calculated directly from the 3D Monte-Carlo simulation code RITRACKS. A cubic volume of 5 micron edge (Figure 1) is irradiated by a (Fe26+)-56 ion of 1 GeV/amu (LET approx.150 keV/micron) and by a fluence of 450 H+ ions, 300 MeV/amu (LET approx. 0.3 keV/micron). In both cases, the dose deposited in the volume is approx.1 Gy. The dose is then calculated into each 3D pixels (voxels) of 20 nm edge and visualized in 3D. RESULTS AND DISCUSSION: The dose is deposited uniformly in the volume by the H+ ions. The voxels which receive a high dose (orange) corresponds to electron track ends. The dose is deposited differently by the 56Fe26+ ion. Very high dose (red) is deposited in voxels with direct ion traversal. Voxels with electron track ends (orange) are also found distributed around the path of the track. In both cases, the appearance of the dose distribution looks very similar to DSBs seen in gammaH2AX experiments, particularly when the visualization threshold is applied. CONCLUSION: The refinement of the dose calculation to the nanometer scale has revealed important differences in the energy deposition between high- and low-LET ions. Voxels of very high dose are only found in the path of high-LET ions. Interestingly, experiments have shown that DSB induced by high-LET radiation are more difficult to repair. Therefore, this new approach may be useful to understand the nature of DSB and oxidative damage induced by ionizing radiation.

Plante, I.↗

Direct Modeling of Scintillator Thickness for Optimal Light Output and Spatial Resolution

It is common in x-ray radiography to use scintillators (e.g., BGO or LSO) to convert x-rays to visible light, which is then recorded by an imaging system. The response of the scintillator depends fundamentally on its thickness, with respect to both its visible light emittance and its spatial resolution. This is important for optimizing light output, signal to noise ratio, or optical response time. Given that it is often cost-prohibitive to procure a variety of scintillator samples and empirically test the performance, it is essential to be able to model and accurately simulate the performance of a scintillator with respect to thickness and other properties, and a direct way of doing this is using Monte Carlo-based radiation transport codes. Such simulations can be expensive in terms of computational time, and the codes are not easily obtained. In this work we first show such simulations, and demonstrate that there is a natural trade-off between light output of a scintillator and its spatial resolution. We then derive a first-principles model that accurately approximates the light output, using straightforward calculations that can be performed quickly with any basic computing software. We compare the results to those obtained from Monte Carlo simulations and show that our simplified model can be used to analyze the tradeoff between emittance and resolution nearly as well as using a full-scale radiation transport code.

Monte Carlo methods, X-ray imaging, scintillation ↗

Estimating ionization states and continuum lowering from ab initio path integral Monte Carlo simulations for warm dense hydrogen

Warm dense matter (WDM) is an active field of research, with applications ranging from astrophysics to inertial confinement fusion. Ionization degree and continuum lowering are important quantities to understand how materials behave under these conditions, but can be difficult to diagnose since experimental campaigns are limited and often require model-dependent analysis. This is especially true for hydrogen, which has a comparably low scattering cross section, making high-quality data particularly difficult to obtain. Consequently, building equation of state tables often relies on simulations in combination with untested approximations to extract properties from experiments. Here, we investigate an approach for extracting the ionization potential depression and ionization degree—quantities which are otherwise not directly accessible from the physical model—from first-principles path integral Monte Carlo (PIMC) simulations utilizing a chemical model. In contrast to experimental measurements, where noise and nonequilibrium effects add to the uncertainty of the inferred parameters, PIMC simulations provide a clean signal with well-defined thermodynamic conditions. Comparisons against commonly used models show a qualitative agreement, but we find deviations primarily for the high-density and high-temperature cases. We also demonstrate the decreasing sensitivity of the dynamic structure factor with respect to both ionization and continuum lowering for increasing scattering angles in x-ray Thomson scattering experiments. Our work has important implications for the design of future experiments, but also offers qualitative understanding of structure factors and the imaginary-time correlation function obtained from first-principles quantum Monte Carlo simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of measured with calculated dose distribution from a 120-MeV electron beam from a laser-plasma accelerator

Purpose: To evaluate the dose distribution of a 120-MeV laser-plasma accelerated electron beam which may be of potential interest for high-energy electron radiation therapy. Methods: In the interaction between an intense laser pulse and a helium gas jet, a well collimated electron beam with very high energy is produced. A secondary laser beam is used to optically control and to tune the electron beam energy and charge. The potential use of this beam for radiation treatment is evaluated experimentally by measurements of dose deposition in a polystyrene phantom. The results are compared to Monte Carlo simulations using the geant4 code. Results: It has been shown that the laser-plasma accelerated electron beam can deliver a peak dose of more than 1 Gy at the entrance of the phantom in a single laser shot by direct irradiation, without the use of intermediate magnetic transport or focusing. The dose distribution is peaked on axis, with narrow lateral penumbra. Monte Carlo simulations of electron beam propagation and dose deposition indicate that the propagation of the intense electron beam (with large self-fields) can be described by standard models that exclude collective effects in the response of the material. Conclusions: The measurements show that the high-energy electron beams produced by an optically injected laser-plasma accelerator can deliver high enough dose at penetration depths of interest for electron beam radiotherapy of deep-seated tumors. Many engineering issues must be resolved before laser-accelerated electrons can be used for cancer therapy, but they also represent exciting challenges for future research.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multi-Scale Modeling of Liquid Phase Sintering Affected by Gravity: Preliminary Analysis

A multi-scale simulation concept taking into account impact of gravity on liquid phase sintering is described. The gravity influence can be included at both the micro- and macro-scales. At the micro-scale, the diffusion mass-transport is directionally modified in the framework of kinetic Monte-Carlo simulations to include the impact of gravity. The micro-scale simulations can provide the values of the constitutive parameters for macroscopic sintering simulations. At the macro-scale, we are attempting to embed a continuum model of sintering into a finite-element framework that includes the gravity forces and substrate friction. If successful, the finite elements analysis will enable predictions relevant to space-based processing, including size and shape and property predictions. Model experiments are underway to support the models via extraction of viscosity moduli versus composition, particle size, heating rate, temperature and time.

Olevsky, Eugene↗