Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Full-wave feasibility study of anti-radar diagnostic of magnetic field based on O-X mode conversion and oblique reflectometry imaging

An innovative millimeter wave diagnostic is proposed to measure the local magnetic field and edge current as a function of the minor radius in the tokamak pedestal region. The idea is to identify the direction of minimum reflectivity at the O-mode cutoff layer. Correspondingly, the transmissivity due to O-X mode conversion is maximum. That direction, and the angular map of reflectivity around it, contains information on the magnetic field vector B at the cutoff layer. Probing the plasma with different wave frequencies provides the radial profile of B. Full-wave finite-element simulations are presented here in 2D slab geometry. Modeling confirms the existence of a minimum in reflectivity that depends on the magnetic field at the cutoff, as expected from mode conversion physics, giving confidence in the feasibility of the diagnostic. The proposed reflectometric approach is expected to yield superior signal-to-noise ratio and to access wider ranges of density and magnetic field, compared with related radiometric techniques that require the plasma to emit electron Bernstein waves. Due to computational limitations, frequencies of 10-20 GHz were considered in this initial study. Frequencies above the edge electron-cyclotron frequency (f > 28 GHz here) would be preferable for the experiment, because the upper hybrid resonance and right cutoff would lie in the plasma, and would help separate the O-mode of interest from spurious X-waves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bayesian tomography and integrated data analysis in fusion diagnostics

In this article, a Bayesian tomography method using non-stationary Gaussian process for a prior has been introduced. The Bayesian formalism allows quantities which bear uncertainty to be expressed in the probabilistic form so that the uncertainty of a final solution can be fully resolved from the confidence interval of a posterior probability. Moreover, a consistency check of that solution can be performed by checking whether the misfits between predicted and measured data are reasonably within an assumed data error. In particular, the accuracy of reconstructions is significantly improved by using the non-stationary Gaussian process that can adapt to the varying smoothness of emission distribution. The implementation of this method to a soft X-ray diagnostics on HL-2A has been used to explore relevant physics in equilibrium and MHD instability modes. This project is carried out within a large size inference framework, aiming at an integrated analysis of heterogeneous diagnostics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of neutron diagnostics on the experimental advanced superconducting tokamak

Neutron diagnostics have become a significant means to study energetic particles in high power auxiliary heating plasmas on the Experimental Advanced Superconducting Tokamak (EAST). Several kinds of neutron diagnostic systems have been implemented for time-resolved measurements of D-D neutron flux, fluctuation, emission profile, and spectrum. All detectors have been calibrated in laboratory, and in situ calibration using {sup 252}Cf neutron source in EAST is in preparation. A new technology of digitized pulse signal processing is adopted in a wide dynamic range neutron flux monitor, compact recoil proton spectrometer, and time of flight spectrometer. Improvements will be made continuously to the system to achieve better adaptation to the EAST’s harsh γ-ray and electro-magnetic radiation environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applying the new gamma ray imager diagnostic to measurements of runaway electron Bremsstrahlung radiation in the DIII-D Tokamak (invited)

A new gamma ray imager (GRI) is developed to probe the electron distribution function with 2D spatial resolution during runaway electron (RE) experiments at the DIII-D tokamak. The diagnostic is sensitive to 0.5–100 MeV gamma rays, allowing characterization of the RE distribution function evolution during RE growth and dissipation. The GRI consists of a lead “pinhole camera” mounted on the DIII-D midplane with 123 honeycombed tangential chords 20 cm wide that span the vessel interior. Up to 30 bismuth germanate (BGO) scintillation detectors capture RE bremsstrahlung radiation for Pulse Height Analysis (PHA) capable of discriminating up to 20 000 pulses per second. Digital signal processing routines combining shaping filters are performed during PHA to reject noise and record gamma ray energy. The GRI setup and PHA algorithms will be described and initial data from experiments will be presented. A synthetic diagnostic is developed to generate the gamma ray spectrum of a GRI channel given the plasma information and a prescribed distribution function. Magnetic reconstructions of the plasma are used to calculate the angle between every GRI sightline and orient and discriminate gamma rays emitted by a field-aligned RE distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diagnostics of laser-produced plasmas based on the analysis of intensity ratios of He-like ions X-ray emission

Here, in this paper, we detail the diagnostic technique used to infer the spatially resolved electron temperatures and densities in experiments dedicated to investigate the generation of magnetically collimated plasma jets. It is shown that the relative intensities of the resonance transitions in emitting He-like ions can be used to measure the temperature in such recombining plasmas. The intensities of these transitions are sensitive to the plasma density in the range of 10 16 –10 20 cm -3 and to plasma temperature ranges from 10 to 100 eV for ions with a nuclear charge Z n ~10. We show how detailed calculations of the emissivity of F VIII ions allow to determine the parameters of the plasma jets that were created using ELFIE ns laser facility (Ecole Polytechnique, France). Lastly, the diagnostic and analysis technique detailed here can be applied in a broader context than the one of this study, i.e., to diagnose any recombining plasma containing He-like fluorine ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Curved diamond-crystal spectrographs for x-ray free-electron laser noninvasive diagnostics

Here, we report on the manufacturing and X-ray tests of bent diamond-crystal X-ray spectrographs, designed for noninvasive diagnostics of the X-ray free-electron laser (XFEL) spectra in the spectral range from 5 to 15 keV. The key component is a curved, 20-µm thin, single crystalline diamond triangular plate in the (110) orientation. The radius of curvature can be varied between R = 0.6 m and R = 0.1 m in a controlled fashion, ensuring imaging in a spectral window of up to 60 eV for ' 8 keV X-rays. All of the components of the bending mechanism (about 10 parts) are manufactured from diamond, thus ensuring safe operations in intense XFEL beams. The spectrograph is transparent to 88% for 5-keV photons, and to 98% for 15-keV photons. Therefore, it can be used for noninvasive diagnostics of the X-ray spectra during XFEL operations.

47 OTHER INSTRUMENTATION↗

Detection of an anomalous pressure on a magneto-inertial-fusion load current diagnostic

Recent Magnetized Liner Inertial Fusion experiments at the Sandia National Laboratories Z pulsed power facility have featured a PDV (Photonic Doppler Velocimetry) diagnostic in the final power feed section for measuring load current. In this paper, we report on an anomalous pressure that is detected on this PDV diagnostic very early in time during the current ramp. Early time load currents that are greater than both B-dot upstream current measurements and existing Z machine circuit models by at least 1 MA would be necessary to describe the measured early time velocity of the PDV flyer. This leads us to infer that the pressure producing the early time PDV flyer motion cannot be attributed to the magnetic pressure of the load current but rather to an anomalous pressure. Using the MHD code ALEGRA, we are able to compute a time-dependent anomalous pressure function, which when added to the magnetic pressure of the load current, yields simulated flyer velocities that are in excellent agreement with the PDV measurement. As a result, we also provide plausible explanations for what could be the origin of the anomalous pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: Infrared laser diagnostics for deuterium gas puff Z pinches

Deuterium gas puff Z pinches have been used for generation of strong neutron fluxes on the MA class pulse power machines. Due to the low electron density of deuterium Z-pinch plasma, regular laser diagnostics in the visible range cannot be used for observation and study of the pinch. Laser probing at the wavelength of 1064 nm was used for visualization of deuterium plasma. Finally, infrared schlieren and interferometry diagnostics showed the deuterium gas puff plasma dynamics, instabilities, and allowed for the reconstruction of the profile of the plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correlation electron cyclotron emission diagnostic and improved calculation of turbulent temperature fluctuation levels on ASDEX Upgrade

A newly upgraded correlation electron cyclotron emission (CECE) diagnostic has been installed on the ASDEX Upgrade tokamak and has begun to perform experimental measurements of electron temperature fluctuations. CECE diagnostics measure small amplitude electron temperature fluctuations by correlating closely spaced heterodyne radiometer channels. This upgrade expanded the system from six channels to thirty, allowing simultaneous measurement of fluctuation level radial profiles without repeat discharges, as well as opening up the possibility of measuring radial turbulent correlation lengths. Newly refined statistical techniques have been developed in order to accurately analyze the fluctuation data collected from the CECE system. This paper presents here the hardware upgrades for this system and the analysis techniques used to interpret the raw data, as well as measurements of fluctuation spectra and fluctuation level radial profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Visible spectroscopy diagnostics for tungsten source assessment in the WEST tokamak: First measurements

The present work concerns the measurements obtained with the Tungsten (W) Environment in Steady-state Tokamak (WEST) visible spectroscopy system during the first experimental campaign. This system has been developed in the framework of the WEST project that equipped the existing Tore Supra device with a tungsten divertor in order to test actively cooled tungsten Plasma Facing Components (PFC) in view of preparing for ITER operation. The goal of this diagnostic is to measure the PFC sources and the deuterium recycling with spectral, spatial, and temporal resolution adapted to the predicted power deposition profiles on the objects observed. Three kinds of PFCs are monitored: the Ion Cyclotron Resonance Heating (ICRH) antenna and Low Hybrid Current Drive (LHCD) launcher W limiters; one of the 6 W inner bumpers; and the upper and lower W divertors. Large-aperture in-vessel actively cooled optical systems (f-number ~ 3) were installed for each view and connected to optical fibres. A total of 240 optical fibers can be distributed on various detection systems including a fast response-time, multi-channel, filtered photodetector-based “Filterscope” system, developed by Oak Ridge National Laboratory (USA) as well as grating spectrometers optimized for multi-sightline analysis. The first WEST experimental campaign conducted in 2017 has been dedicated to plasma start-up development during which the visible spectroscopy system has provided crucial information related to the impurity content first and then impurity sources. The diagnostic setup for that first experimental campaign was limited to the inner bumper and outer limiters but was sufficient to demonstrate that the optical setup was in accordance with the specifications. The radiance calibration procedure allowed us to estimate fluxes from the main limiter of about 8 × 10 18 atoms/(s m 2 ) and to show a first W source radial profile along the outboard limiter.

Meyer, O.↗

Implementation of a Wollaston interferometry diagnostic on OMEGA EP

Here, a Wollaston interferometer is presented for use in measuring the electron density of plasma plumes created in experiments on the OMEGA EP laser system. The diagnostic is installed as an additional arm on the 4ω probe system, a suite of diagnostics that share a 10 ps pulse of 263 nm laser light captured by an imaging system at f /4. The interferometer utilizes a Wollaston prism to create two angularly separated beams from a single input probe beam, split at any angle between 0° and 90°. This configuration is implemented uniquely such that fringe spacing may be altered independently of field of view, magnification, and imaging resolution, from a range of 17 to 76 μm/fringe. The region of overlap between the two beams forms a total field of view of approximately 1.2 × 1.6 mm at the target chamber center with an imaging resolution of 5 μm. Using this configuration, here it is shown that plasma density may be accurately characterized over a range of 3 × 10 18 –1 × 10 20 cm -3 .

47 OTHER INSTRUMENTATION↗

An x-ray optic calibration facility for high energy density diagnostics

A facility to calibrate x-ray imaging optics was built at Lawrence Livermore National Laboratory to support high energy density (HED) and inertial confinement fusion (ICF) diagnostics such as those at the National Ignition Facility and the Sandia Z-Machine. Calibration of the spectral reflectivity and resolution of these x-ray diagnostics enable absolute determination of the x-ray flux and wavelengths generated in the HED and ICF experiments. Measurement of the optic point spread function is used to determine spatial resolution of the optic. This facility was constructed to measure (1) the x-ray reflectivity to ±5% over a spectral range from 5 to 60 keV; (2) point spread functions with a resolution of 50 μm (currently) and 13 μm (future) in the image plane; and (3) optic distance relative to the x-ray source and detector to within ±100 μm in each dimension. Here, this article describes the capabilities of the calibration facility, concept of operations, and initial data from selected x-ray optics.

47 OTHER INSTRUMENTATION↗

Implementation of a Talbot–Lau x-ray deflectometer diagnostic platform for the OMEGA EP laser

A Talbot–Lau X-ray Deflectometer (TXD) was implemented in the OMEGA EP laser facility to characterize the evolution of an irradiated foil ablation front by mapping electron densities >10 22 cm -3 by means of Moiré deflectometry. The experiment used a short-pulse laser (30–100 J, 10 ps) and a foil copper target as an x-ray backlighter source. In the first experimental tests performed to benchmark the diagnostic platform, grating survival was demonstrated and x-ray backlighter laser parameters that deliver Moiré images were described. Finally, the necessary modifications to accurately probe the ablation front through TXD using the EP-TXD diagnostic platform are discussed.

36 MATERIALS SCIENCE↗

Study of laser-driven magnetic fields with a continuous wave Faraday rotation diagnostic

Magnetic fields driven by a laser in coil targets were studied for laser energies of ~25 J and two pulse durations of 2.8 ns and 70 ps. Axial magnetic fields in the coils were measured by continuous wave Faraday rotation diagnostics. The diagnostics indicated magnetic fields of 6–14 T in the coil and currents of 10–20 kA. Magnetic fields were compared for similar laser targets, focusing conditions, and laser energies. A 30-times increase in the intensity of the laser beam by reducing the pulse duration resulted in an increase in the magnetic field and current by a factor of 2. The relaxation time of the magnetic pulse was on the sub-microsecond scale.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diagnostic development for parallel wave-number measurement of lower hybrid waves in EAST

In this study, an eight-channel magnetic probe diagnostic system has been designed and installed adjacent to the 4.6 GHz lower hybrid (LH) grill antenna in the low-field side of the Experimental Advanced Superconducting Tokamak (EAST) in order to study the n ∥ evolution of LH waves in the first pass from the launcher to the core plasma. The magnetic probes are separated by 6.6 mm, which allows measurement of the dominant parallel refractive index n ∥ up to n ∥ = 5 for 4.6 GHz LH waves. The magnetic probes are designed to be sensitive to the magnetic field component perpendicular to the background magnetic field with a slit on the casing that encloses the probe. The intermediate frequency stage, which consists of two mixing stages, down-coverts the frequency of the measured wave signals at 4.6 GHz to 20 MHz. A bench test demonstrates the phase stability of the magnetic probe diagnostic system. By evaluating the phase variation of the measured signals along the background magnetic field, the dominant n ∥ of the LH wave in the scrape-off layer has been deduced during the 2019 experimental campaign. In the low density plasma, the measured dominant n ∥ of the LH waves is about 2.1, corresponding to the main peak 2.04 of the launched n ∥ spectrum. n ∥ deduced by the least-squares linear fit method remains near this value in the low density plasma with a high spatial correlation magnitude of 0.9. With an eight-channel probe system, a wave-number spectrum has also been deduced, which has a peak near to the measured dominant n ∥ .

47 OTHER INSTRUMENTATION↗

A compact, high resolution energy, and emittance diagnostic for electron beams using active plasma lenses

High-resolution (sub-%), single-shot energy distribution, and emittance measurements of GeV-class electron beams generated by laser plasma accelerators (LPAs) have been enabled through the use of an active plasma lens combined with relatively short dipole magnets. This setup, with only 60 cm between the LPA source and the final diagnostic screen, was facilitated through the use of a replenishable ∼20–40 nm thick liquid crystal plasma mirror to separate remnant laser radiation from the electron beam without emittance degradation. As LPAs capable of generating GeV-class electron beams at cm-scale distances become increasingly ubiquitous, there is a need to supplement these compact accelerators with equally compact diagnostics.

Barber, S. K. (ORCID:0000000172518755)↗

System-on-chip upgrade of millimeter-wave imaging diagnostics for fusion plasma

Monolithic, millimeter wave “system-on-chip” technology has been employed in chip heterodyne radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature and fluctuation diagnostics. The system employs 20 horn-waveguide receiver modules each with customized W-band (75–110 GHz) monolithic microwave integrated circuit chips comprising a W-band low noise amplifier, a balanced mixer, a ×2 local oscillator (LO) frequency doubler, and two intermediate frequency amplifier stages in each module. Compared to previous quasi-optical ECEI arrays with Schottky mixer diodes mounted on planar antennas, the upgraded W-band array exhibits >30 dB additional gain and 20× improvement in noise temperature; an internal eight times multiplier chain is used to provide LO coupling, thereby eliminating the need for quasi-optical coupling. The horn-waveguide shielding housing avoids out-of-band noise interference on each module. The upgraded ECEI system plays an important role for absolute electron temperature and fluctuation measurements for edge and core region transport physics studies. An F-band receiver chip (up to 140 GHz) is under development for additional fusion facilities with a higher toroidal magnetic field. Visualization diagnostics provide multi-scale and multi-dimensional data in plasma profile evolution. Finally, a significant aspect of imaging measurement is focusing on artificial intelligence for science applications.

47 OTHER INSTRUMENTATION↗

A transmitted-beam diagnostic for the wavelength-tunable UV drive beam on OMEGA

A transmitted-beam diagnostic (P9TBD) was developed as part of a new experimental platform used to study laser–plasma interactions on OMEGA. Located in the opposing port to the wavelength-tunable (350 nm to 353 nm) UV drive beam, the P9TBD characterizes the beam after it propagates through an undersense plasma. The instrument consists of a large-aperture window that allows light to exit the target chamber and project onto a thin sheet of semi-transparent diffuser material. Light transmitted through the diffuser is recorded using a time-integrated camera and a fiber-optically coupled streaked spectrometer, providing measurements of the energy, power, fluence, polarization, and spectrum of the transmitted beam. Here, the diagnostic enables direct observation of a variety of cross-beam energy transfer phenomena, such as wavelength detuning, polarization effects, and gain saturation.

47 OTHER INSTRUMENTATION↗