Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detector grounding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

High Resolution Triple Axis X-Ray Diffraction Analysis of II-VI Semiconductor Crystals

The objective of this research program is to develop methods of structural analysis based on high resolution triple axis X-ray diffractometry (HRTXD) and to carry out detailed studies of defect distributions in crystals grown in both microgravity and ground-based environments. HRTXD represents a modification of the widely used double axis X-ray rocking curve method for the characterization of grown-in defects in nearly perfect crystals. In a double axis rocking curve experiment, the sample is illuminated by a monochromatic X-ray beam and the diffracted intensity is recorded by a fixed, wide-open detector. The intensity diffracted by the sample is then monitored as the sample is rotated through the Bragg reflection condition. The breadth of the peak, which is often reported as the full angular width at half the maximum intensity (FWHM), is used as an indicator of the amount of defects in the sample. This work has shown that high resolution triple axis X-ray diffraction is an effective tool for characterizing the defect structure in semiconductor crystals, particularly at high defect densities. Additionally, the technique is complimentary to X-ray topography for defect characterization in crystals.

Volz, H. M.↗

Optical Transient Detector (OTD) Observations of a Tornadic Thunderstorm

Total lightning observations made by the Optical Transient Detector (OTD) of a tornadic thunderstorm that occurred over Oklahoma on 17 April 1995 are presented. The average flash rate of the tornadic storm during the 3.2 min observation period was 45 flashes/min, with a flash rate density of 1.16 x 10(exp -4)/s sq km. The total flash rate was almost 18 times higher than the cloud-to-ground rate measured by the National Lightning Detection Network (NLDN). In addition, total lightning rates were observed to decrease prior to tornadic development.

Buechler, D. E.↗

"Smoke": Characterization Of Smoke Particulate For Spacecraft Fire Detection

The "Smoke" experiment is a flight definition investigation that seeks to increase our understanding of spacecraft fire detection through measurements of particulate size distributions of preignition smokes from typical spacecraft materials. Owing to the catastrophic risk posed by even a very small fire in a spacecraft, the design goal for spacecraft fire detection is to detect the fire as quickly as possible, preferably in the preignition phase before a real flaming fire has developed. Consequently the target smoke for detection is typically not soot (typical of established hydrocarbon fires) but instead, pyrolysis products, and recondensed polymer particles. At the same time, false alarms are extremely costly as the crew and the ground team must respond quickly to every alarm. The U.S. Space Shuttle (STS: Space Transportation System) and the International Space Station (ISS) both use smoke detection as the primary means of fire detection. These two systems were designed in the absence of any data concerning low-gravity smoke particle (and background dust) size distributions. The STS system uses an ionization detector coupled with a sampling pump and the ISS system is a forward light scattering detector operating in the near IR. These two systems have significantly different sensitivities with the ionization detector being most sensitive (on a mass concentration basis) to smaller particulate and the light scattering detector being most sensitive to particulate that is larger than 1 micron. Since any smoke detection system has inherent size sensitivity characteristics, proper design of future smoke detection systems will require an understanding of the background and alarm particle size distributions that can be expected in a space environment.

Urban, David L.↗

Ground-Based Measurements of Stratospheric Composition from Mt. Barcroft, California

The MkIV is an FTIR spectrometer designed and built at JPL in the 1980's for remote sensing the composition of the Earth's atmosphere by solar absorption spectrometry. Optically, MkIV is very similar to the JPL ATMOS instrument, which flew three times on the Space Shuttle. Both use double-passed configurations with a KBr beamsplitter and compensator, in order to cover the mid-infrared. The main advantage of the MkIV is that it uses two detectors in parallel, a HgCdTe photoconductor for the long wavelengths and an InSb photodiode for the short wavelengths, allowing the entire 650 to 5650/cm region to be measured simultaneously. At a 10 kHz sampling rate, each 130 cm OPD interferogram takes 3 minutes to acquire. This paper describes how the MkIV instrument was adapted for remote operation from the Barcroft site, where the harsh winter conditions make access difficult. Some of the main technical challenges will be discussed including, (i) operation from solar panels and batteries, (ii) cooling the detectors with LN2, (iii) instrument control and monitoring over a cellular phone, and (iv) data storage, processing and analysis. Finally, MkIV spectra measured from Barcroft are compared with those measured from JPL to highlight the advantages of the higher altitude site.

Toon, G. C.↗

Data processing in infrared astronomy

Infrared astronomy is often carried out with rocket probes or orbiting satellite telescopes in order to escape the effects of atmospheric absorption. The data returned from such missions is a highly abstracted digital representation of measurements made by analog detectors. The ability to extract infrared-emission information from these data streams depends on a thorough understanding of the information flow from the telescope aperture to the computer center. This paper reviews the primary elements of this end-to-end concept and the impact of each of these elements on the data processing algorithms, including the division between onboard and ground processing for scientific measurements.

Pelzmann, R. F., Jr.↗

Nonclassical and nonlocal effects in the interference of light

Although we tend to think of optical interference as a classical wave phenomenon, recent experiments have revealed a number of effects that are not describable in classical terms. This is particularly true of interference effects involving the detection of a photon pair. We shall refer to them as fourth order interference, on the grounds that the joint probability density for the detection of one photon at r sub 1 at time t and another r sub 2 at time t is proportional to the fourth order correlation function of the field. This probability is readily measured when two photodetectors are positioned at r sub 1 and r sub 2 and the signals from the two detectors are fed to a coincidence counter that registers 'simultaneous' detections by the two detectors in coincidence. The topics covered include: fourth order interference measurements; the Franson experiment; and experimental test of the de Broglie guided wave theory.

Mandel, L.↗

Limitations and Feasibility of Mini X-Ray Devices in Space Environments

LIMITATIONS AND FEASIBILITY OF MINI X-RAY DEVICES IN SPACE ENVIRONMENTS As space exploration advances toward long-duration missions, reliable medical diagnostic tools become increasingly critical. The miniature x-ray (XR) technology demonstrations by the Exploration Medical Capability (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) aim to assess the feasibility and utility of miniature XR devices in spaceflight. This abstract explores the limitations of current miniature XR systems, the challenges of training crew members, the potential role of clinical decision support systems (CDSS), and the feasibility of ground-based image interpretation. We also propose the integration of miniature XR into other ExMC efforts aimed at identifying the capabilities and resources needed for future exploration class missions. One of the primary challenges with miniature XR devices is the ability to achieve specific anatomical views, particularly in the confined and weightless conditions of a spacecraft. Operators may struggle to acquire diagnostic-quality images when space is limited for proper patient positioning and the volume of the imaging device. Since space radiation and detector limitations may further impact image quality, the flexibility of the operating procedures of these devices will be critical for their success in space applications. CHALLENGES IN TRAINING CREW TO OPERATE IMAGING DEVICES Training in the skills necessary to acquire diagnostic-quality scans may be a barrier for non-clinician crewmembers. The curriculum developed for crew medical officers (CMOs) will require simplification and adaptation to fit into the highly truncated pre-flight training period. Therefore, hands-on familiarization and simulation, both pre-flight and just-in-time training during missions, will be crucial to ensuring the crew can operate the devices in real-life situations. The ability to adjust acquisition parameters must be simplified or made automatic through exam selections on equipment user interfaces, and subject and operator positioning should be assisted with laser guidance and pictorial guides. POTENTIAL FOR CDSS OR ARTIFICIAL INTELLIGENCE (AI)-ASSISTED CDSS CDSS and AI-assisted CDSS offer significant promise in assisting crew members with limited medical training. These systems could provide real-time feedback on image quality and interpretation, helping to mitigate the risks of human error during space missions. Integrating procedural guidance tools, such as virtual and augmented reality, will support crewmembers in accurately positioning patients and obtaining high-quality images. However, the success of such systems will depend on the development of robust training datasets, integration with spaceflight-rated hardware, and the medical decision-making capabilities of operators. FEASIBILITY OF GROUND INTERPRETATION AND DATA TRANSMISSION Reliance on ground-based interpretation may prove difficult for acute care during exploration class-missions due to delays in transmission with increasing distance from Earth or complete communication blackout periods. In such instances where immediate interpretation for clinical intervention is required, crew must be able to interpret the images independently or utilize AI-based assistance to do so. File sizes for XR exams can also be large if numerous images are acquired and bandwidth constraints may limit data transmissions for both radiography and ultrasound exams. FUTURE WORK AND INTEGRATION INTO THE EVIDENCE LIBRARY Future work proposes integrating miniature XR devices into NASA’s Evidence Library to address medical conditions identified as significant contributors to crew morbidity and mortality. The possibility of combining miniature XR with other imaging modalities, such as ultrasound devices, is also under investigation. In conclusion, while miniature XR technology holds potential for extraterrestrial medical systems, there are significant challenges to overcome. Training, integration of AI tools, dedicated exam protocols for microgravity, and improved data transmission systems will be key to realizing the full benefits of miniature XR technology in space.

A M Nelson↗

Infrared thermal mapping experiment - The Viking Mars Orbiter.

The Mars infrared thermal mapper (IRTM) will be carried on the scan platform of the orbiter of the Viking 1975 mission. The IRTM is a multichannel radiometer with several detectors in each of six spectral regions. The spectral channels are selected to be sensitive to surface emissivity variations and provide good temperature resolution over the entire range of Martian temperatures. These observations will allow determination of the surface kinetic temperature and thermal balance, and by coverage of the dark hemisphere, a search for regions with anomalous cooling can be made. Observations of ground frosts or clouds will help to determine their composition, and in the case of extensive H2O frosts, will allow the local water vapor pressure to be estimated.

Kieffer, H. H.↗

JSC Stardust Curation Team

STARDUST, a NASA Discovery-class mission, is the first to return samples from a comet. Grains from comet Wild 2's coma-the gas and dust envelope that surrounds the nucleus-will be collected as well as interstellar dust. The mission which launched on February 7, 1999 will encounter the comet on January 10, 2004. As the spacecraft passes through the coma, a tray of silica aerogel will be exposed, and coma grains will impact there and become captured. Following the collection, the aerogel tray is closed for return to Earth in 2006. A dust impact mass spectrometer on board the STARDUST spacecraft will be used to gather spectra. of dust during the entire mission, including the coma passage. This instrument will be the best chance to obtain data on volatile grains, which will not be well-collected in the aerogel. The dust impact mass spectrometer will also be used to study the composition of interstellar grains. In the past 5 years, analysis of data from dust detectors aboard the Ulysses and Galileo spacecraft have revealed that there is a stream of interstellar dust flowing through our solar system. These grains will be captured during the cruise phase of the STARDUST mission, as the spacecraft travels toward the comet. The sample return capsule will parachute to Earth in February 2006, and will land in western Utah. Once on y the ground, the sample return capsule will be placed into a dry nitrogen environment and flown to the curation lab at JSC.

Zolensky, Michael E.↗

Optical Parametric Technology for Methane Measurements

Atmospheric methane (CH4) is the second most important anthropogenic greenhouse gas, with approximately 25 times the radiative forcing of carbon dioxide (CO2) per molecule. Yet, lack of understanding of the processes that control CH4 sources and sinks and its potential release from stored carbon reservoirs contributes significant uncertainty to our knowledge of the interaction between carbon cycle and climate change. At Goddard Space Flight Center (GSFC) we have been developing the technology needed to remotely measure CH4 from orbit. Our concept for a CH4 lidar is a nadir viewing instrument that uses the strong laser echoes from the Earth's surface to measure CH4. The instrument uses a tunable, narrow-frequency light source and photon-sensitive detector to make continuous measurements from orbit, in sunlight and darkness, at all latitudes and can be relatively immune to errors introduced by scattering from clouds and aerosols. Our measurement technique uses Integrated Path Differential Absorption (IPDA), which measures the absorption of laser pulses by a trace gas when tuned to a wavelength coincident with an absorption line. We have already demonstrated ground-based and airborne CH4 detection using Optical Parametric Amplifiers (OPA) at 1651 nm using a laser with approximately 10 microJ/pulse at 5kHz with a narrow linewidth. Next, we will upgrade our OPO system to add several more wavelengths in preparation for our September 2015 airborne campaign, and expect that these upgrades will enable CH4 measurements with 1% precision (10-20 ppb).

oscillator↗

Breadboard linear array scan imager using LSI solid-state technology

The performance of large scale integration photodiode arrays in a linear array scan (pushbroom) breadboard was evaluated for application to multispectral remote sensing of the earth's resources. The technical approach, implementation, and test results of the program are described. Several self scanned linear array visible photodetector focal plane arrays were fabricated and evaluated in an optical bench configuration. A 1728-detector array operating in four bands (0.5 - 1.1 micrometer) was evaluated for noise, spectral response, dynamic range, crosstalk, MTF, noise equivalent irradiance, linearity, and image quality. Other results include image artifact data, temporal characteristics, radiometric accuracy, calibration experience, chip alignment, and array fabrication experience. Special studies and experimentation were included in long array fabrication and real-time image processing for low-cost ground stations, including the use of computer image processing. High quality images were produced and all objectives of the program were attained.

Tracy, R. A.↗

An Analysis of the High Frequency Vibrations in Early Thematic Mapper Scenes

The motion of the mirrors in the thematic mapper (TM) and multispectral scanner (MSS) instruments, and the motion of other devices, such as the TDRSS antenna drive, and solar array drives onboard LANDSAT-4 cause vibrations to propagate through the spacecraft. These vibrations as well as nonlinearities in the scanning motion of the TM mirror can cause the TM detectors to point away from their nominal positions. Two computer programs, JITTER and SCDFT, were developed as part of the LANDSAT-D Assessment System (LAS), Products and Procedures Analysis (PAPA) program to evaluate the potential effect of high frequency vibrations on the final TM image. The maximum overlap and underlap which were observed for early TM scenes are well within specifications for the ground processing system. The cross scan and scan high frequency vibrations are also within the specifications cited for the flight system.

Kogut, J.↗

Development of the SAMEX vector magnetograph at the Marshall Space Flight Center

A breadboard design to prove the operational feasibility of SAMEX Vector Magnetograph is being developed. Although the breadboard design will not include all of the elements of the original design concept, critical elements such as the large detector array and the high resolution polarimeter will be important parts of the breadboard design to study the data analysis and compression techniques that will be needed in a SAMEX instrument, to study the calibration techniques for systemmatic errors in the polarimeter, and to obtain high resolution vector magnetograms during the next solar maximum. Although the SAMEX polarimeter is not optimum for a ground-based patrol instrument, the design concept can be confirmed with ground-based measurements and direct comparisons with the existing vector magnetograph. The extension of the scientific objectives for this breadboard design is possible if a tunable filter can be acquired.

West, E. A.↗

A Hard-X-Ray Telescope Science Enhancement Package for the Constellation-X Mission

We present a science enhancement package (SEP) for NASA's planned Constellation-X mission submitted in response to a call for white papers. The call solicited proposals for either extending the bandwidth of Con-X to higher energies or enhancing the low-energy spectral resolution. The ground rules were that enhancement package should cost no more than $100M and weigh no more than 100 kg. The nickel-replicated-optics team responded with a stand-alone hard-x-ray telescope SEP concept. This consisted of two mirror modules, each with approximately 70 multilayer and iridium-coated shells, and two corresponding cadmium-zinc-telluride-based focal plane detectors. Addition of this package permits measurement of the hard-x-ray continuum up to 30-40 keV, which is essential for a quantitative measurement of the spectrum of gravitationally broadened iron lines that appear in the spectra of many black hole candidates. Full details of the instrument will be presented showing trades in energy bandwidth and effective area together with the full science justification for the enhancement package.

Ramsey, Brian↗

Detecting Conductive Liquid Leaking from Nonconductive Pipe

A method that can be implemented with relatively simple electronic circuitry provides a capability for detecting leakage of an electrically conductive liquid from an electrically nonconductive underground pipe. Alternatively or in addition, the method can be applied to locate the pipe, whether or not there is a leak. Although the method is subject to limitations (some of which are described below), it is still attractive as an additional option for detecting leaks and locating pipes without need for extensive digging. The method is based on capacitive coupling of an alternating electrical signal from the liquid to a portable electronic unit that resembles a metal detector. A signal voltage is applied to the liquid at some convenient point along the pipe: for example, the signal could be coupled into the liquid via an aboveground metal pipe fitting, the interior surface of which is in contact with the liquid. The signal is conducted through the liquid in the pipe; in the case of diffusive leak of liquid into the surrounding ground, the signal is conducted through the leak, into the portion of the adjacent ground that has become soaked with the liquid. (A drip leak cannot be detected by this method because there is no conductive path between the liquid inside and the liquid outside the pipe.) The portable unit includes an electrically conductive plate connected to the input terminal of an amplifier. When the plate is brought near the pipe or the leaked liquid, a small portion of the signal power is coupled capacitively from the liquid to the plate. The user scans the plate near the ground surface to find the locus of maximum signal strength. The leak can be identified as a relatively wide area, contiguous with the location of the pipe, over which the signal is detectable.

Youngquist, Robert C.↗

Performance analysis of a filtered wide field-of-view radiometer for earth radiation budget measurements

The proposed Earth Radiation Budget Satellite System (ERBSS) of the 1980's will include a wide field-of-view (WFOV) fixed axes earth radiator discriminator consisting of a shortwave channel and a total (unfiltered) channel. The broadband spectral isolation required for the shortwave channel is achieved by use of a hemispherical fused silica (Suprasil W) dome filter placed in front of a wire wound thermopile radiation detector. A description is presented of the thermal response of the single-fused silica dome filter in the ERBSS WFOV shortwave channel conceptual design and the impact of that response on the channel measurement. Results from design definition and performance analysis studies are included. Problems associated with achieving the desired levels of confidence in a high accuracy filtered, WFOV radiometer are discussed. Design approaches, ground calibration, and data reduction techniques which minimize measurement uncertainties are explained.

Cooper, J. E.↗

Observations of the plasma torus of Jupiter with a Fabry-Perot/charge-coupled device /CCD/ imaging spectrometer

A description is presented of the use of a CCD imaging spectrometer which has been employed at a 2.1 m telescope to obtain monochromatic images in the red and near infrared. The system studied was Jupiter's plasma torus which circles the planet with radial extent about 5 RJ and 7 RJ (RJ is the radius of Jupiter). In ground based measurements the torus has been observed in the forbidden emission lines of S(plus) at 6716 A and 6731 A and S(plus plus) at 9531 A. Attention is given to aspects of instrumentation, observations, and performance. It is felt that the particular significance of the obtained results from the instrumental point of view is the demonstration that the CCD is an excellent detector for monochromatic imaging in the near infrared out to at least 10830 A and that pixel binning before readout can produce significantly improved S/N ratios for the study of faint, diffuse sources in cases where readout noise is dominant.

Roesler, F. L.↗

Astrometric telescope of ten microarcsecond accuracy on the Space Station

The Astrometric Telescope Facility (ATF) will be operated in the NASA Space Station in the 1990s, furnishing long term, highly accurate relative astrometry of nearby stars in order to detect gravitational perturbations by companion stars with masses as small as that of Neptune. An accuracy of 10 microarcsec is required; this is 100 times better than ground observatory performance. In the Gatewood et al. (1980) astrometric technique used, the relative positions of star images in the telescope focal plane are indicated by the relative phases of the modulations of star brightnesses introduced by translating a Ronchi ruling across the focal plane at uniform speed. Space Station vibration damping, fine guiding accuracy, optical configuration, Ronchi ruling metric accuracy, and the choice of detectors, are discussed.

Levy, E. H.↗