Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Detection.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Shear horizontal surface acoustic wave microsensor for Class A viral and bacterial detection.

The rapid autonomous detection of pathogenic microorganisms and bioagents by field deployable platforms is critical to human health and safety. To achieve a high level of sensitivity for fluidic detection applications, we have developed a 330 MHz Love wave acoustic biosensor on 36{sup o} YX Lithium Tantalate (LTO). Each die has four delay-line detection channels, permitting simultaneous measurement of multiple analytes or for parallel detection of single analyte containing samples. Crucial to our biosensor was the development of a transducer that excites the shear horizontal (SH) mode, through optimization of the transducer, minimizing propagation losses and reducing undesirable modes. Detection was achieved by comparing the reference phase of an input signal to the phase shift from the biosensor using an integrated electronic multi-readout system connected to a laptop computer or PDA. The Love wave acoustic arrays were centered at 330 MHz, shifting to 325-328 MHz after application of the silicon dioxide waveguides. The insertion loss was -6 dB with an out-of-band rejection of 35 dB. The amplitude and phase ripple were 2.5 dB p-p and 2-3{sup o} p-p, respectively. Time-domain gating confirmed propagation of the SH mode while showing suppression of the triple transit. Antigen capture and mass detection experiments demonstrate a sensitivity of 7.19 {+-} 0.74{sup o} mm{sup 2}/ng with a detection limit of 6.7 {+-} 0.40 pg/mm{sup 2} for each channel.

60 APPLIED LIFE SCIENCES↗

Passive imaging based multi-cue hazard detection spacecraft safe landing

Accurate assessment of potentially damaging ground hazards during the spacecraft EDL (Entry, Descent and Landing) phase is crucial to insure a high probability of safe landing. A lander that encounters a large rock, falls off a cliff, or tips over on a steep slope can sustain mission ending damage. Guided entry is expected to shrink landing ellipses from 100-300 km to -10 km radius for the second generation landers as early as 2009. Regardless of size and location, however, landing ellipses will almost always contain hazards such as craters, discontinuities, steep slopes, and large rocks. It is estimated that an MSL (Mars Science Laboratory)-sized lander should detect and avoid 16- 150m diameter craters, vertical drops similar to the edges of 16m or 3.75m diameter crater, for high and low altitude HAD (Hazard Detection and Avoidance) respectively. It should also be able to detect slopes 20' or steeper, and rocks 0.75m or taller. In this paper we will present a passive imaging based, multi-cue hazard detection and avoidance (HDA) system suitable for Martian and other lander missions. This is the first passively imaged HDA system that seamlessly integrates multiple algorithm-crater detection, slope estimation, rock detection and texture analysis, and multicues- crater morphology, rock distribution, to detect these hazards in real time.

hazard detection↗

Automated detection of photovoltaic cleaning events: A performance comparison of techniques as applied to a broad set of labeled photovoltaic data sets

Extracting accurate soiling loss information from photovoltaic (PV) production data first requires segmenting the time series data per natural or manually occurring cleaning events. Maintenance logs are often incomplete, rain data are often unavailable, and the debate on rain thresholds for cleaning and dew or wind cleanings is still ongoing. The present work aims to overtake these issues by improving automated methods to detect these cleaning events and therefore improve extraction of soiling loss information. Time series power production data from 22 PV inverters were labeled for natural or manually occurring cleaning events. The data sets were carefully selected to include varying degrees of soiling, cleaning events, and noise. Several algorithms, including filtering logic and change point detection, were examined for efficacy at detecting the labeled cleanings. All the methods introduced except for changepoint detection showed significant improvement at detecting the labeled cleaning events per the mean F 1 score. Furthermore, the highest performing cleaning detection algorithm achieved an absolute increase in the mean F 1 score of 43% over the default version of the RdTools stochastic rate and recovery (SRR) algorithm. The highest performing algorithm included irradiance filtering and a cleaning detection threshold, adjusted based on the 40-day centered rolling median of the absolute day-to-day deviations in the daily performance index (PI). Furthermore, these improvements are promising as cleaning detection is an essential step in the automated analysis of PV soiling.

14 SOLAR ENERGY↗

Radioxenon Detection for Monitoring Subsurface Nuclear Explosion

The Comprehensive Nuclear-Test-Ban Treaty (CTBT) bans the testing of nuclear weapons anywhere on the earth (atmospheric, surface, underwater and subsurface). Identification of nuclear explosions in the atmosphere, surface, and underwater is relatively straightforward considering a wide range of signatures resulting from such an event. However, for a subsurface explosion, most of the signatures traditionally associated with a nuclear explosion are not readily available. Therefore, the international community has increasingly relied on the atmospheric measurement of noble gases to identify subsurface nuclear weapon explosions. This chapter initially covers the basic principles of subsurface nuclear explosion identification and the importance of detecting radioxenon. This is followed by reviewing some of the early radioxenon detection systems that were developed by research groups around the world in the late 1990s and early 2000s. The detection media employed, results from laboratory and field testing, and some challenges/drawbacks for these systems are detailed. The next section of the chapter is dedicated to innovative detector concepts that have emerged in the past ten to fifteen years using novel detection material, algorithms, and signal readout techniques. The advances achieved in terms of energy resolution, coincidence detection efficiencies, system performance, and the minimum detectable concentration are covered. The final section goes over some of the potential improvements that can be incorporated in the design to enhance detector sensitivity and new detection material that can be explored in the field of radioxenon detection.

Gadey, Harish Reddy↗

Optical Bragg, atomic Bragg and cavity QED detections of quantum phases and excitation spectra of ultracold atoms in bipartite and frustrated optical lattices

Ultracold atoms loaded on optical lattices can provide unprecedented experimental systems for the quantum simulations and manipulations of many quantum phases and quantum phase transitions between these phases. However, so far, how to detect these quantum phases and phase transitions effectively remains an outstanding challenge. In this paper, we will develop a systematic and unified theory of using the optical Bragg scattering, atomic Bragg scattering or cavity QED to detect the ground state and the excitation spectrum of many quantum phases of interacting bosons loaded in bipartite and frustrated optical lattices. The physically measurable quantities of the three experiments are the light scattering cross sections, the atom scattered clouds and the cavity leaking photons respectively. We show that the two photon Raman transition processes in the three detection methods not only couple to the density order parameter, but also the valence bond order parameter due to the hopping of the bosons on the lattice. This valence bond order coupling is very sensitive to any superfluid order or any valence bond (VB) order in the quantum phases to be probed. These quantum phases include not only the well-known superfluid and Mott insulating phases, but also other important phases such as various kinds of charge density waves (CDW), valence bond solids (VBS), and CDW-VBS phases with both CDW and VBS orders unique to frustrated lattices, and also various kinds of supersolids. We analyze respectively the experimental conditions of the three detection methods to probe these various quantum phases and their corresponding excitation spectra. We also address the effects of a finite temperature and a harmonic trap. We contrast the three scattering methods with recent in situ measurements inside a harmonic trap and argue that the two kinds of measurements are complementary to each other. The combination of both kinds of detection methods could be used to match the combination of Scanning tunneling microscopy (STM), the Angle Resolved Photo Emission spectroscopy (ARPES) and neutron scattering in condensed matter systems, therefore achieve the putative goals of quantum simulations - Highlights: Black-Right-Pointing-Pointer Develop a systematic and unified theory of various scattering experiments. Black-Right-Pointing-Pointer Discuss the optical Bragg, atomic Bragg and cavity QED detection methods. Black-Right-Pointing-Pointer Explore the detections of various quantum phases in various kinds of optical lattices. Black-Right-Pointing-Pointer Present the detections of valence bond order and the supersolid order. Black-Right-Pointing-Pointer Contrast the scattering methods with the in situ measurement.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Statistical change detection of building energy consumption: Applications to savings estimation

The surge in interval meter data availability and associated activity in energy data analytics has inspired new interest in advanced methods for building efficiency savings estimation. Statistical and machine learning approaches are being explored to improve the energy baseline models used to measure and verify savings. One outstanding challenge is the ability to identify and account for operational changes that may confound savings estimates. In the measurement and verification (M&V) context, ‘non-routine events’ (NREs) cause changes in building energy use that are not attributable to installed efficiency measures, and not accounted for in the baseline model’s independent variables. In the M&V process NREs must be accounted for as ‘adjustments’ to appropriately attribute the estimated energy savings to the specific efficiency interventions that were implemented. Currently this is a manual and custom process, conducted using professional judgment and engineering expertise. As such it remains a barrier in scaling and standardizing meter-based savings estimation. Here in this work, a data driven methodology was developed to (partially) automate, and therefore streamline the process of detecting NREs in the post-retrofit period and making associated savings adjustments. The proposed NRE detection algorithm is based on a statistical change point detection method and a dissimilarity metric. The dissimilarity metric measures the proximity between the actual time series of the post-retrofit energy consumption and the projected baseline, which is generated using a statistical baseline model. The suggested approach for NRE adjustment involves the NRE detection algorithm, the M&V practitioner, and a regression modeling algorithm. The performance of the detection and adjustment algorithm was evaluated using a simulation-generated test data set, and two benchmark algorithms. Results show a high true positive detection rate (75%-100% across the test cases), higher than ideal false positive detection rates (20%-70%), and low errors in energy adjustment (<0.7%). These results indicate that the algorithm holds for helping M&V practitioners to streamline the process of handling NREs. Moreover, the change point algorithm and underlying statistical principles could prove valuable for other building analytics applications such as anomaly detection and fault diagnostics.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

The role of source geometry and atmospheric propagation in global bolide infrasound detectability

Global infrasound monitoring provides a persistent means of detecting energetic bolide atmospheric entries, complementing optical observations and extending coverage over remote regions. We present a global assessment of the physical factors governing bolide infrasound detectability by correlating 623 bolide events reported by the Center for Near-Earth Object Studies between 2007 and 2025 with waveform data from the International Monitoring System. We identify 311 events with confirmed infrasound detections, corresponding to a detection rate of approximately 50%, substantially higher than inferred from earlier surveys, reflecting both the maturation of the global infrasound network and advances in automated, multi-frequency array processing. Analysis of flight parameters shows that infrasound detectability is selective rather than uniform across the bolide population. Detected events are preferentially associated with steeper entry angles and lower-altitude energy deposition, while shallow, high-altitude trajectories are less consistently observed. Very high-energy events remain detectable regardless of geometry, but for the more common lower-energy regime, observability depends on specific combinations of entry parameters and propagation conditions. This geometric dependence persists across comparable energy ranges and atmospheric conditions, indicating that entry angle exerts a primary control on detectability, with energy and propagation acting as secondary modulating factors. Furthermore, these results provide new physical constraints on bolide-atmosphere interactions and improve interpretation of global infrasound observations for planetary defense and atmospheric-entry studies.

Bolides↗

Human Papillomavirus (HPV) Infection in Squamous Cell Carcinomas Arising From the Oropharynx: Detection of HPV DNA and p16 Immunohistochemistry as Diagnostic and Prognostic Indicators—A Pilot Study

Purpose: Human papillomavirus (HPV) 16 infection is associated with oropharyngeal carcinogenesis and is likely the cause of the reported increase in disease incidence. We evaluated the prevalence of HPV infection and the reliability of different diagnostic tools using primary tumor samples from a cohort of 50 patients. Methods and Materials: Formalin-fixed paraffin-embedded (FFPE) tumor samples were collected from all 50 consecutive primary oropharyngeal SCC patients who were enrolled in the study; fresh tumor samples were available in 22 cases. NucliSENS EasyQ HPVv1 was used for RNA, and Digene Hybrid Capture-2(HC2) was used for DNA detection. p16 Expression was evaluated by immunohistochemistry in FPPE specimens. Results: Based on the DNA detection assay on FFPE samples, the frequency of high-risk HPV infection was 32%. The agreement rate between HPV RNA and HPV DNA detection in fresh samples was 100%. The agreement rate between p16 immunohistochemistry (IHC) and the detection of HPV DNA in the FFPE samples was fair but not excellent (κ = 0.618). HPV DNA detection was highly significant, as measured by disease-specific survival and determined using a Wilcoxon test (P=.001). p16 IHC also exhibited a prognostic value but with a lower statistical significance (P=.0475). The detection of HPV DNA, but not p16 IHC, was also significantly correlated with locoregional control (P=.0461). Conclusion: Diagnostic methods based on the detection of HPV nucleic acids appear to be more reliable and objective because they do not require reading by a trained histopathologist. Furthermore, the detection of HPV DNA exhibits an improved correlation with survival, and therefore appears definitely more reliable than p16 IHC for routine use in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effect of DNA damage on the pattern of immune-detectable DNA methylation in mouse embryonic fibroblasts

The methylation of cytosine at CpG dinucleotides (5meC) is an important epigenetic mechanism that governs genome stability and gene expression. Important ontological and pathological transitions are associated with marked global changes in detectable levels of methylation. We have previously found two pools of immune-detectable 5meC exist within cells, a pool that can be detected after acid treatment of fixed cells to denature chromatin and another large but variable pool that requires a further tryptic digestion step for complete epitope retrieval. The trypsin-sensitive pool has been shown to be largely associated with the heterochromatic fraction (by a heterochromatin marker, HP1-β) of the genome, and the size of this pool varies with the growth disposition of cells. Since DNA damage imposes large changes on chromatin structure the present study analyzed how such changes influences the faithful immunological detection of 5meC within mouse embryonic fibroblasts. DNA damage was induced by either UV-irradiation or doxorubicin treatment, each of which resulted in increased levels of immune-detectable 5meC at 24–48 h after treatment. There was a marked trypsin-sensitive pool of 5meC in these cells which was significantly increased after DNA damage. The increased levels of 5meC staining predominantly co-located with heterochromatic foci within nuclei, as assessed by HP1-β staining. The relative amount of masked 5meC after DNA damage was positively associated with increased levels of HP1-β. The methyl binding protein, MBD1, was a less reliable measure of changes in 5meC, with a significant fraction of 5meC not being marked by MBD1. The cyto-epigenetic approaches used here reveal dynamism in the levels and localization of immune-detectable 5meC within the nuclei of fibroblasts in response to DNA damage. - Highlights: • Immune-detectable 5meC within two pools retrieved after acid and trypsin after acid. • The size of the trypsin-sensitive pool varied in response to DNA damage. • This was associated with changes in the level of HP1-β within heterochromatic foci. • Epitope retrieval method detected remarkable dynamism in 5meC's level and location.

60 APPLIED LIFE SCIENCES↗

The influence of environmental microseismicity on detection and interpretation of small-magnitude events in a polar glacier setting

Glacial environments exhibit temporally variable microseismicity. To investigate how microseismicity influences event detection, we implement two noise-adaptive digital power detectors to process seismic data from Taylor Glacier, Antarctica. We add scaled icequake waveforms to the original data stream, run detectors on the hybrid data stream to estimate reliable detection magnitudes and compare analytical magnitudes predicted from an ice crack source model. We find that detection capability is influenced by environmental microseismicity for seismic events with source size comparable to thermal penetration depths. When event counts and minimum detectable event sizes change in the same direction (i.e. increase in event counts and minimum detectable event size), we interpret measured seismicity changes as ‘true’ seismicity changes rather than as changes in detection. Generally, one detector (two degree of freedom (2dof)) outperforms the other: it identifies more events, a more prominent summertime diurnal signal and maintains a higher detection capability. We conclude that real physical processes are responsible for the summertime diurnal inter-detector difference. One detector (3dof) identifies this process as environmental microseismicity; the other detector (2dof) identifies it as elevated waveform activity. Our analysis provides an example for minimizing detection biases and estimating source sizes when interpreting temporal seismicity patterns to better infer glacial seismogenic processes.

54 ENVIRONMENTAL SCIENCES↗

Enhanced Stability and Sensitivity for CA-125 Detection Under Microfluidic Shear Flow Using Polyethylene Glycol-Coated Biosensor

The microfluidic-based point-of-care (POC) diagnostic tool has garnered significant interest in recent years, offering rapid and cost-effective disease detection. There is a growing trend toward integrating microfluidic platforms with biosensors, aligning lab-on-a-chip technologies with POC diagnostic devices. Despite numerous efforts to incorporate biosensors into microfluidic systems, researchers have performed very limited investigations on the stability of biomarker detection when biosensors operate under microfluidic shear flow conditions. Gold nanoparticles (AuNPs) are a widely employed material in capacitive biosensors for antibody immobilization and sensitivity enhancement. However, AuNPs have limitations in providing stable detection of biomarkers within microfluidic shear flow due to their agglomeration nature. This study addresses these limitations by employing 2 kDa polyethylene glycol (PEG) as an intermediate biofunctional layer to immobilize CA-125 antibodies on gold-interdigitated electrodes for the stable and accurate detection of CA-125 antigens. The stabilities and sensitivities of AuNPs and PEG-coated biosensors are evaluated under both static drop and microfluidic shear flow conditions for CA-125 antigen detection. The experimental results demonstrate a capacitive signal response (5660 pF at 10 kHz) 2.2 times higher using the PEG-coated biosensor than the signal (2551 pF at 10 kHz) measured by the AuNP-coated biosensor in the detection of CA-125 antigen–antibody conjugation under static drop conditions, indicating the higher sensitivity of the PEG-coated biosensor. Additionally, the PEG-coated biosensor exhibits better consistency for the CA-125 antigen detection between static drop and microfluidic shear flow conditions (Cp decrease in percentage (ΔCp%↓) = 2.9% at 10 kHz) compared to the electrical signals measured using the AuNP-coated biosensor (ΔCp%↓ = 32.4% at 10 kHz), which suggests that the PEG-coated biosensor demonstrates higher stability for CA-125 antigen detection under microfluidic shear flow conditions. With these significant improvements brought by the PEG-coated biosensor, especially under microfluidic conditions, a substantial hurdle in developing electrical biosensors for POC diagnostic applications has been overcome, expediting further advancements in the field.

36 MATERIALS SCIENCE↗

Detecting sulphate aerosol geoengineering with different methods

Sulphate aerosol injection has been widely discussed as a possible way to engineer future climate. Monitoring it would require detecting its effects amidst internal variability and in the presence of other external forcings. Here, we investigate how the use of different detection methods and filtering techniques affects the detectability of sulphate aerosol geoengineering in annual-mean global-mean near-surface air temperature. This is done by assuming a future scenario that injects 5 Tg yr -1 of sulphur dioxide into the stratosphere and cross-comparing simulations from 5 climate models. 64% of the studied comparisons would require 25 years or more for detection when no filter and the multi-variate method that has been extensively used for attributing climate change are used, while 66% of the same comparisons would require fewer than 10 years for detection using a trend-based filter. This then highlights the high sensitivity of sulphate aerosol geoengineering detectability to the choice of filter. With the same trend-based filter but a non-stationary method, 80% of the comparisons would require fewer than 10 years for detection. This does not imply sulphate aerosol geoengineering should be deployed, but suggests that both detection methods could be used for monitoring geoengineering in global, annual mean temperature should it be needed.

54 ENVIRONMENTAL SCIENCES↗

Image-based novel fault detection with deep learning classifiers using hierarchical labels

One important characteristic of modern fault classification systems is the ability to flag the system when faced with previously unseen fault types. This work considers the unknown fault detection capabilities of deep neural network-based fault classifiers. Specifically, we propose a methodology on how, when available, labels regarding the fault taxonomy can be used to increase unknown fault detection performance without sacrificing model performance. To achieve this, we propose to utilize soft label techniques to improve the state-of-the-art deep novel fault detection techniques during the training process and novel hierarchically consistent detection statistics for online novel fault detection. Lastly, we demonstrated increased detection performance on novel fault detection in inspection images from the hot steel rolling process, with results well replicated across multiple scenarios and baseline detection methods.

42 ENGINEERING↗

DETECTABILITY OF EXOPLANETS IN THE {beta} PIC MOVING GROUP WITH THE GEMINI PLANET IMAGER

We model the detectability of exoplanets around stars in the {beta} Pic Moving Group (BPMG) using the Gemini Planet Imager (GPI), a coronagraphic instrument designed to detect companions by imaging. Members of the BPMG are considered promising targets for exoplanet searches because of their youth ({approx}12 Myr) and proximity (median distance {approx}35 pc). We wrote a modeling procedure to generate hypothetical companions of given mass, age, eccentricity, and semi-major axis, and place them around BPMG members that fall within the V-band range of the GPI. We count companions lying within the GPI's field of view and H-band fluxes that have a host-companion flux ratio placing them within its sensitivity as possible detections. The fraction of companions that could be detected depends on their brightness at 12 Myr, and hence formation mechanism, and on their distribution of semi-major axes. We used brightness models for formation by disk instability and core-accretion. We considered the two extreme cases of the semi-major axis distribution-the log-normal distribution of the nearby F- and G-type stars and a power-law distribution indicated by the exoplanets detected by the radial velocity technique. We find that the GPI could detect exoplanets of all the F and G spectral type stars in the BPMG sample with a probability that depends on the brightness model and semi-major axis distribution. At spectral type K-M1, exoplanet detectability depends on brightness and hence distance of the host star. GPI will be able to detect the companions of M stars later than M1 only if they are closer than 10 pc. Of the four A stars in the BPMG sample, only one has a V-band brightness in the range of GPI; the others are too bright.

79 ASTRONOMY AND ASTROPHYSICS↗

THE SWIFT BURST ALERT TELESCOPE DETECTED SEYFERT 1 GALAXIES: X-RAY BROADBAND PROPERTIES AND WARM ABSORBERS

We present results from an analysis of the broadband, 0.3-195 keV, X-ray spectra of 48 Seyfert 1-1.5 sources detected in the very hard X-rays with the Swift Burst Alert Telescope (BAT). This sample is selected in an all-sky survey conducted in the 14-195 keV band. Therefore, our sources are largely unbiased toward both obscuration and host galaxy properties. Our detailed and uniform model fits to Suzaku/BAT and XMM-Newton/BAT spectra include the neutral absorption, direct power-law, reflected emission, soft excess, warm absorption, and narrow Fe I K{alpha} emission properties for the entire sample. We significantly detect O VII and O VIII edges in 52% of our sample. The strength of these detections is strongly correlated with the neutral column density measured in the spectrum. Among the strongest detections, X-ray grating and UV observations, where available, indicate outflowing material. The ionized column densities of sources with O VII and O VIII detections are clustered in a narrow range with N{sub warm} {approx} 10{sup 21} cm{sup -2}, while sources without strong detections have column densities of ionized gas an order of magnitude lower. Therefore, we note that sources without strong detections likely have warm ionized outflows present but at low column densities that are not easily probed with current X-ray observations. Sources with strong complex absorption have a strong soft excess, which may or may not be due to difficulties in modeling the complex spectra of these sources. Still, the detection of a flat {Gamma} {approx} 1 and a strong soft excess may allow us to infer the presence of strong absorption in low signal-to-noise active galactic nucleus spectra. Additionally, we include a useful correction from the Swift BAT luminosity to bolometric luminosity, based on a comparison of our spectral fitting results with published spectral energy distribution fits from 33 of our sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Bennett-Brassard 1984 quantum key distribution using conjugate homodyne detection

Optical homodyne detection has been widely used in continuous-variable (CV) quantum information processing for measuring field quadrature. In this paper we explore the possibility of operating a conjugate homodyne detection system in “photon counting” mode to implement discrete-variable (DV) quantum key distribution (QKD). A conjugate homodyne detection system, which consists of a beam splitter followed by two optical homodyne detectors, can simultaneously measure a pair of conjugate quadratures X and P of the incoming quantum state. In classical electrodynamics, X 2 + P 2 is proportional to the energy (the photon number) of the input light. In quantum optics, X and P do not commute and thus the above photon-number measurement is intrinsically noisy. This implies that a blind application of standard security proofs of QKD could result in pessimistic performance. We overcome this obstacle by taking advantage of two special features of the proposed detection scheme. First, the fundamental detection noise associated with vacuum fluctuations cannot be manipulated by an external adversary. Second, the ability to reconstruct the photon number distribution at the receiver's end can place additional constraints on possible attacks from the adversary. As an example, we study the security of the BB84 QKD using conjugate homodyne detection and evaluate its performance through numerical simulations. This study may open the door to a family of QKD protocols, complementary to the well-established DV-QKD based on single-photon detection and CV-QKD based on coherent detection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Active Detection for Exposing Intelligent Attacks in Control Systems

In this paper, we consider approaches for detecting integrity attacks carried out by intelligent and resourceful adversaries in control systems. Passive detection techniques are often incorporated to identify malicious behavior. Here, the defender utilizes finely-tuned algorithms to process information and make a binary decision, whether the system is healthy or under attack. We demonstrate that passive detection can be ineffective against adversaries with model knowledge and access to a set of input/output channels. We then propose active detection as a tool to detect attacks. In active detection, the defender leverages degrees of freedom he has in the system to detect the adversary. Specifically, the defender will introduce a physical secret kept hidden from the adversary, which can be utilized to authenticate the dynamics. In this regard, we carefully review two approaches for active detection: physical watermarking at the control input, and a moving target approach for generating system dynamics. We examine practical considerations for implementing these technologies and discuss future research directions.

25 ENERGY STORAGE↗