Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Defect detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Arrays of Si vacancies in 4 H -SiC produced by focused Li ion beam implantation

Point defects in SiC are an attractive platform for quantum information and sensing applications because they provide relatively long spin coherence times, optical spin initialization, and spin-dependent fluorescence readout in a fabrication-friendly semiconductor. The ability to precisely place these defects at the optimal location in a host material with nano-scale accuracy is desirable for integration of these quantum systems with traditional electronic and photonic structures. Here, we demonstrate the precise spatial patterning of arrays of silicon vacancy (${V}_{Si}$) emitters in an epitaxial 4H -SiC (0001) layer through mask-less focused ion beam implantation of Li + . We characterize these arrays with high-resolution scanning confocal fluorescence microscopy on the Si-face, observing sharp emission lines primarily coming from the ${V1}^{{\prime}}$ zero-phonon line (ZPL). The implantation dose is varied over 3 orders of magnitude, leading to ${V}_{Si}$ densities from a few per implantation spot to thousands per spot, with a linear dependence between ZPL emission and implantation dose. Optically-detected magnetic resonance (ODMR) is also performed, confirming the presence of V2 ${V}_{Si}$. Our investigation reveals scalable and reproducible defect generation.

36 MATERIALS SCIENCE↗

Silicon Carbide Epitaxial Films Studied by Atomic Force Microscopy

Silicon carbide (SiC) holds great potential as an electronic material because of its wide band gap energy, high breakdown electric field, thermal stability, and resistance to radiation damage. Possible aerospace applications of high-temperature, high-power, or high-radiation SiC electronic devices include sensors, control electronics, and power electronics that can operate at temperatures up to 600 C and beyond. Commercially available SiC devices now include blue light-emitting diodes (LED's) and high-voltage diodes for operation up to 350 C, with other devices under development. At present, morphological defects in epitaxially grown SiC films limit their use in device applications. Research geared toward reducing the number of structural inhomogeneities can benefit from an understanding of the type and nature of problems that cause defects. The Atomic Force Microscope (AFM) has proven to be a useful tool in characterizing defects present on the surface of SiC epitaxial films. The in-house High-Temperature Integrated Electronics and Sensors (HTIES) Program at the NASA Lewis Research Center not only extended the dopant concentration range achievable in epitaxial SiC films, but it reduced the concentration of some types of defects. Advanced structural characterization using the AFM was warranted to identify the type and structure of the remaining film defects and morphological inhomogeneities. The AFM can give quantitative information on surface topography down to molecular scales. Acquired, in part, in support of the Advanced High Temperature Engine Materials Technology Program (HITEMP), the AFM had been used previously to detect partial fiber debonding in composite material cross sections. Atomic force microscopy examination of epitaxial SiC film surfaces revealed molecular-scale details of some unwanted surface features. Growth pits propagating from defects in the substrate, and hillocks due, presumably, to existing screw dislocations in the substrates, were imaged. Away from local defects, step bunching was observed to yield step heights of hundreds of angstroms, with possible implications for the uniformity of dopants incorporated in SiC devices during fabrication. The quantitative topographic data from the AFM allow the relevant defect information to be extracted, such as the size and distribution of step bunching and the Burgers vector of screw dislocations. These atomic force microscopy results have furthered the understanding of the dynamic epitaxial SiC growth process. A model describing the observed hillock step bunching has been proposed. This cooperation between researchers involved in crystal growth, electronic device fabrication, and surface structural characterization is likely to continue as atomic force microscopy is used to improve SiC films for high-temperature electronic devices for NASA's advanced turbine engines and space power devices, as well as for future applications in the automotive industry.

Source record↗

Incipient Failure Detection (IFD) of antifriction ball bearings

Two methods were investigated for retrieving the ball bearing signals buried by the overall signature of an operating large engine such as the main space shuttle engine. The signal averaging method averages n** signals over a time duration equaling the known period of the ball bearing defect frequency. With this method, the desired ball bearing defect signal will be enhanced over the noise by a factor of the square root of n. A second method is to perform a further frequency analysis on the logarithmic spectrum in order to detect and separate different families of harmonics and sidebands, thereby giving information about modulating frequencies. These two alternate IFD methods were carried out with a Norland 3001 waveform and data system. The obtained results are then compared with the power spectral density (PSD) of the overall machine signals and conclusions are made accordingly.

Wang, D. Y.↗

Detection and Characterization of Imperfections in Composite Pressure Vessels

The thermographic evaluation of composite structures for delaminations, disbonds, inclusions, porosity and microcracking has proven to be a valuable asset in the field of nondestructive testing. Coupling large area coverage, variable sensitivity and minimal surface contact with a photographic type image representation of structural anomalies; thermography has become a primary inspection method for composite structures. Thermography works well for locating both surface and subsurface defects in most composite systems ranging in thickness of up to 0.25 inch (0.64 cm) or more. The thermographic method for inspection of composite structures typically involves applying an external source of heat to the structure and then recording the changes in the surface heat profile manifested by embedded defects or by material property variations. If these temperature variations are large enough and an infrared camera with sufficient sensitivity is used, then the material or structural abnormality can be detected and referred back to its source. Interpreting the information given in a thermogram, can be a difficult task under ideal circumstances and extremely challenging in a real world setting. Variables including depth, thermal conductivity, orientation and size of the abnormality can all have a great influence on how its heat pattern will be seen by the imager. The work discussed in this paper illustrates how the microstructure of several commonly found defects in composite structures relate to their thermographic image counterpart. Two test cases are studied herein, including a large graphite/epoxy RP-1 fuel tank and a graphite composite cryogenic fuel feedline. The structures used in this study were designed to serve as manufacturing proof of concept specimens and to undergo hydroburst testing to verify manufacturing practices and structural design. Prior to hydrostatic testing the structures underwent 100% thermographic evaluation to ensure that no manufacturing or handling damage was present. Due to a large inclusion found in the feedline, it was pulled from service and dissected without performing the hydroproof The thermographic indications found in the RP-1 tank were below critical limits so it underwent a complete hydroproof loading series and finally a hydroburst. Following the hydroburst samples were cut from the tank in regions where thermography had located damage before the test. These regions were thermographically and then were cross-sectioned and photomicrographed.

Walker, James L.↗

Anomaly detection in PV systems using constrained low-rank and sparse decomposition

PV (photovoltaic) systems, also known as solar panel systems, play an essential role in the mitigation of greenhouse gas emissions and the promotion of renewable energy. Through the conversion of sunlight into usable energy, electricity is generated without emitting greenhouse gases and producing pollutants. Notwithstanding the evolutionary significance of PV systems, the occurrence of defects and anomalies in PV systems may result in diminished power output, consequently impeding the efficiency of the systems and potentially resulting in hazards in certain circumstances. Therefore, early detection of faults and anomalies in PV systems is imperative to guarantee the reliability, efficiency, and safety of the systems. In this article, we develop a signal decomposition for the purpose of anomaly detection in PV systems. The proposed methodology is grounded on the concept of low-rank and sparse decomposition, with consideration given to the signs of the decomposed low-rank and sparse components, as well as the smooth variations within and between periods in the mean signals. Through the implementation of Monte Carlo simulations, we showcase the efficacy of our proposed methodology in identifying anomalies of varying durations and magnitudes in PV systems. A case study is employed to validate the proposed methodology in detecting anomalies in real PV systems.

14 SOLAR ENERGY↗

Data-Driven Discovery of Linear Molecular Probes with Optimal Selective Affinity for PFAS in Water

Approaches to tackle the wide and growing variety of highly persistent per- and polyfluoroalkyl substances (PFAS) are of pressing global need because of their detrimental human health effects, such as cancer, birth defects, and hormone imbalance. Sensitive, selective, and easy-to-use real-time sensors to monitor and detect PFAS and sorbents to extract them are critical to meeting government-mandated environmental concentrations. In this work, we combine all-atom molecular dynamics simulations, enhanced sampling, deep representational learning, and Bayesian optimization to perform high-throughput virtual screening for highly sensitive and selective molecular probes. Our molecular design space consists of 3850 linear hydrocarbon chains with varying degrees of halogenation with and without amine- and phosphine-based headgroups. By employing a data-driven search process, we efficiently explore the molecular design space to optimize the sensitivity to perfluorooctanesulfonic acid (PFOS) as a prototypical PFAS analyte and selectivity relative to a sodium dodecyl sulfate (SDS) interferent. We calculate 504 Gibbs free energies of probe-analyte and probe-interferent interactions and identify probes with PFOS association free energies of up to (-ΔG PFOS ) = 9.8 ± 0.2 kJ/mol and selectivities relative to SDS of (-ΔΔG PFOS–SDS ) = 3.1 ± 1.5 kJ/mol. A C 11 Br 23 P(CH 3 ) 2 probe containing 11 backbone brominated carbons and a tertiary phosphine headgroup possesses the most sensitive binding constant to PFOS within the defined search space of K b PFOS = 177.4 ± 12.7, and a semibrominated probe C 5 H 11 C 7 Br 14 N(CH 3 ) 2 containing 12 backbone carbons and a tertiary amine headgroup possesses the highest selectivity relative to SDS of K b PFOS /K b SDS = 4.6 ± 1.7. A retrospective analysis of our data to extract interpretable design rules reveals that the sensitivity of linear hydrogenated probes increases by approximately 1 kJ/mol per C–C bond. The addition or removal of halogen atoms and amine or phosphine headgroups produces nonmonotonic changes in both sensitivity and selectivity with changes to the sensitivity of up to 2.5 kJ/mol. Finally, this work places empirical limitations on the performance of a wide range of linear probes for PFOS detection and offers a generic strategy for high-throughput computational screening to promote selective and sensitive binding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Self-powered perovskite photon-counting detectors

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm –2 ) to 2 cps mm –2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. Finally, this study opens a new application of photon counting for perovskites that uses their unique defect properties.

47 OTHER INSTRUMENTATION↗

Short-range order and longer-range disorder revealed in germanium–tin alloy thin films by extended x-ray absorption fine structure analysis

Short-range order (SRO) in semiconductor alloys, a relatively under-studied structural phenomenon in which local atomic arrangements differ from those of a random solid solution, is investigated in molecular beam epitaxy (MBE)-grown GeSn thin films. A novel preparation technique is used to pattern these films into microscale ribbons that are released from the substrate for extended x-ray absorption fine structure (EXAFS) analysis. The results indicate a strong SRO in which the first shell around Sn atoms is greatly denuded of Sn atoms relative to the nominal atomic composition of the alloy. This effect is more pronounced than that observed recently in GeSn nanowires grown by chemical vapor deposition. Additionally, the presence of a longer-range disorder detected by EXAFS analysis in the shells of atoms more distant from the absorbers is indicative of the defects and inhomogeneous strain present in the MBE-grown films. The evident existence of the SRO in GeSn alloys deposited by different growth methods and in different strain states suggests that SRO is a general phenomenon in the thin films of this metastable solid solution.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rare isotope-containing diamond colour centres for fundamental symmetry tests

Detecting a non-zero electric dipole moment in a particle would unambiguously signify physics beyond the Standard Model. A potential pathway towards this is the detection of a nuclear Schiff moment, the magnitude of which is enhanced by the presence of nuclear octupole deformation. However, due to the low production rate of isotopes featuring such ‘pear-shaped’ nuclei, capturing, detecting and manipulating them efficiently is a crucial prerequisite. Incorporating them into synthetic diamond optical crystals can produce defects with defined, molecule-like structures and isolated electronic states within the diamond band gap, increasing capture efficiency, enabling repeated probing of even a single atom and producing narrow optical linewidths. In this study, we used density functional theory to investigate the formation, structure and electronic properties of crystal defects in diamond containing 229 ⁢Pa, a rare isotope that is predicted to have an exceptionally strong nuclear octupole deformation. In addition, we identified and studied stable lanthanide-containing defects with similar electronic structures as non-radioactive proxies to aid in experimental methods. Our findings hold promise for the existence of such defects and can contribute to the development of a quantum information processing-inspired toolbox of techniques for studying rare isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

Small area silicon diffused junction X-ray detectors

The low-temperature performance of silicon diffused junction detectors in the measurement of low energy X-rays is reported. The detectors have an area of 0.04 sq cm and a thickness of 100 microns. The spectral resolutions of these detectors were found to be in close agreement with expected values, indicating that the defects introduced by the high-temperature processing required in the device fabrication were not deleteriously affecting the detection of low-energy X-rays. Device performance over a temperature range of 77 K to 150 K is given. These detectors were designed to detect low-energy X-rays in the presence of minimum ionizing electrons. The successful application of silicon-diffused junction technology to X-ray detector fabrication may facilitate the development of other novel silicon X-ray detector designs.

Walton, J. T.↗

Higher Sensitivity in X-Ray Photography

Hidden defects revealed if X-ray energy decreased as exposure progresses. Declining-potential X-ray photography detects fractures in thin metal sheet covered by unbroken sheet of twice thickness. Originally developed to check solder connections on multilayer circuit boards, technique has potential for other nondestructive testing.

Buggle, R. N.↗

Growth of mercuric iodide (HgI2) for nuclear radiation detectors

Mercuric iodide is a material used for the fabrication of the sensing element in solid state X-ray and gamma ray detecting instruments. The operation of the devices is determined to a large degree by the density of structural defects in the single crystalline material used in the sensing element. Since there were strong indications that the quality of the material was degraded by the effects of gravity during the growth process, a research and engineering program was initiated to grow one or more crystals of mercuric iodide in the reduced gravity environment of space. A special furnace assembly was designed which could be accommodated in a Spacelab rack, and at the same time made it possible to use the same growth procedures and controls used when growing a crystal on the ground. The space crystal, after the flight, was subjected to the same evaluation methods used for earth-grown crystals, so that comparisons could be made.

Vandenberg, L.↗

Ultrasonic Lamb Wave Inspection of Composite Defects

Composites have been extensively used in aerospace engineering due to their advantages of light weight, high strength, and engineering design flexibility. Manufacturing defects such as wrinkle and porosity can affect the performance of the composites and may lead to failure in the end, while damage such as delamination, fiber fraction, and matrix cracking can directly cause failure of the composites. In this paper, a Lamb wave based nonintrusive nondestructive evaluation system, which employs piezoelectric transducer for actuation and scanning laser Doppler vibrometer for wavefield sensing, is presented for typical composite defect and damage inspection and evaluation. Two composite panels with different geometry (flat or curved) and with various embedded defects (wrinkle and delamination) are inspected using the nonintrusive Lamb wave system. Both the wrinkles and delamination are detected from the wavefield and approximately quantified through wavefield imaging methods.

Wrinkles↗

Modeling of Guided Waves for Aerospace Applications

Advancements in computer hardware has led to new possibilities for rapid modeling and simulation capabilities across many scientific fields. Nondestructive evaluation (NDE) can benefit from increased use of simulation tools to guide optimization of inspection and health monitoring methods, enhance understanding of data, aid in development of defect characterization methods, and generate data sets for use with machine learning and model-assisted probability of detection. Recent work at NASA has entailed development and benchmarking of both custom simulation codes and commercial simulation tools for ultrasonic wave propagation. This paper describes recent work at NASA in modeling of guided waves in composites and other aerospace materials. Results and computational speeds for a composite benchmark case are reported for a custom finite difference Rotated Staggered Grid code and for the commercial finite element software package, Pogo. Recent progress in linking NDE models to parametric analysis tools is also discussed.

Nondestructive evaluation↗

BioSentinel ISS mission: Analysis of ISS Flight Data and Lessons Learned

As we prepare for a future with a human presence on the Moon, Mars, and beyond, the need for countermeasures to protect astronauts against deep space radiation is ever pressing. However, our understanding of how life operates in the space environment, especially past the protection of the Van Allen radiation belts, is critically limited. BioSentinel, a biological CubeSat, aims to further investigate the effects of deep space ionizing radiation, utilizing the budding yeast Saccharomyces cerevisiae to examine the cell’s DNA damage response. The yeast wild type and a rad51Δ mutant strain defective for DNA damage repair will be monitored via the redox dye alamarBlue and a 3-color LED detection system. Selected as a secondary payload on Artemis I, BioSentinel will be the first deep space biological experiment in a half-century and the first biological CubeSat or free-flyer to ever reach a heliocentric orbit. Notably, BioSentinel is the only biological CubeSat to include an ISS control study in addition to a ground control. Comparisons between the ground, ISS, and free-flyer experiments will allow us to isolate the effects of deep space radiation from those of microgravity. The ISS study also provides a unique platform to conduct important technological and biological testing of BioSentinel’s instrumentation in preparation for the deep space mission. In this work, we use a series of data processing tools and scripts to analyze ISS flight data as well as samples exposed to simulated space radiation at Brookhaven National Laboratory, specifically looking at cell growth, metabolic activity, and duplication rates based on optical absorbance and alamarBlue kinetics. These analyses provide a crucial set of controls and a framework for analyzing and interpreting future data sets from the free-flyer, helping us gain further insight into the health risks astronauts will face when exposed to deep space radiation.

Kylie Lauren Lo-Wen Akiyama↗

Accelerating Discovery of Atomistic Defects via Machine Learning

The quantification of defects such as vacancies in crystalline structures is a cornerstone of materials science research. Traditional efforts often rely on manual detection, a process that is time-intensive, prone to human error, and challenging to scale. Here we leverage machine learning (ML) methods to identify and quantify vacancies within a crystalline lattice, aiming to expedite detection while improving accuracy. Additionally, we explore the transferability of these ML techniques, identifying characteristics of atomistic imaging data that complicate this task. We show how the integration of ML can drive innovation, providing a powerful tool that will play an increasingly crucial role in the future of materials science.

2D materials↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗