Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data acquisition systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

First results from gamma ray diagnostics in EAST Tokamak

Gamma ray diagnostics has been developed in the EAST tokamak recently. Six BGO scintillator detectors are arranged on the down-half cross-section and pointed at the up-half cross-section of plasma, with space resolution about 15 cm and energy range from 0.3 MeV to 6 MeV. Three main gamma ray peaks in the energy spectra have been observed and are identified as the results of nuclear reactions {sup 207}Pb(n, n′){sup 207m}Pb, H(n, γ) D, and D(p, γ){sup 3}He, respectively. Upgrading of the system is in progress by using LaBr3(Ce) scintillator, fast photo-multiplier tubes, and a fully digital data acquisition system based on high sample frequency digitizers with digital pulse processing algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Speed Recording of Test Data on Hard Disks

Disk Recording System (DRS) is a systems-integration computer program for a direct-to-disk (DTD) high-speed data acquisition system (HDAS) that records rocket-engine test data. The HDAS consists partly of equipment originally designed for recording the data on tapes. The tape recorders were replaced with hard-disk drives, necessitating the development of DRS to provide an operating environment that ties two computers, a set of five DTD recorders, and signal-processing circuits from the original tape-recording version of the HDAS into one working system. DRS includes three subsystems: (1) one that generates a graphical user interface (GUI), on one of the computers, that serves as a main control panel; (2) one that generates a GUI, on the other computer, that serves as a remote control panel; and (3) a data-processing subsystem that performs tasks on the DTD recorders according to instructions sent from the main control panel. The software affords capabilities for dynamic configuration to record single or multiple channels from a remote source, remote starting and stopping of the recorders, indexing to prevent overwriting of data, and production of filtered frequency data from an original time-series data file.

Lagarde, Paul M., Jr.↗

Goldstone solar system radar signal processing

A performance analysis of the planetary radar data acquisition system is presented. These results extend previous computer simulation analysis and are facilitated by the development of a simple analytical model that predicts radar system performance over a wide range of operational parameters. The results of this study are useful to both the radar system designer and the science investigator in establishing operational radar data acquisition parameters which result in the best systems performance for a given set of input conditions.

Jurgens, R.↗

Calorimetry Triggering in ATLAS

The ATLAS experiment is preparing for data taking at 14 TeV collision energy. A rich discovery physics program is being prepared in addition to the detailed study of Standard Model processes which will be produced in abundance. The ATLAS multi-level trigger system is designed to accept one event in 2/10{sup 5} to enable the selection of rare and unusual physics events. The ATLAS calorimeter system is a precise instrument, which includes liquid Argon electro-magnetic and hadronic components as well as a scintillator-tile hadronic calorimeter. All these components are used in the various levels of the trigger system. A wide physics coverage is ensured by inclusively selecting events with candidate electrons, photons, taus, jets or those with large missing transverse energy. The commissioning of the trigger system is being performed with cosmic ray events and by replaying simulated Monte Carlo events through the trigger and data acquisition system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Software Architecture and Hardware Organization in Mu2e Solenoid Field Mapping System

Herein, the Mu2e field mapping system is designed to produce high accuracy field maps of the detector solenoid used in the experiment. The data acquisition system is mobile and uses a self-propelled mapper with rotating arms equipped with 3D Hall probes. The measurements require not only accurate magnetic field readouts, but also accurate locations of all Hall probes while measuring data. The latter is accomplished by using the laser tracker to measure positions of several retroreflectors on the field mapper during data acquisition. The measurement process requires scanning the whole space inside the large solenoid and takes many hours to complete, which necessitates its full automation. The automation software includes control of the mapper, readout of Hall and NMR probes and control of a laser tracker, including prediction of retroreflector positions and execution of quality control checks. The software architecture and data acquisition hardware of the field mapping system are described, with special attention given to control of the laser tracker and its integration with the rest of the system.

3d hall probes↗

Digital optical module electronics of KM3NeT

The KM3NeT neutrino telescope is being built on the Mediterranean sea and, once completed, it will be composed by tens of thousands of glass spheres (nodes) including each 31 of small photocathode (3”). The readout and data acquisition system of KM3NeT has to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers and at the same time to provide time synchronization between each node at the level of 1 ns. It is described in the present article all the electronics developed for achieving this goal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation Of Exotic Shapes, Correlations And Isomers In Nuclei With Large Compton Suppressed Clover Array

An array is designed for 24 Compton suppressed clover detectors. Recent results from the array will be presented which highlights the structure of nuclei in A {approx} 110 and 130 region and investigation of different reactions dynamics. The perspectives offered by the forthcoming operation of the clover array coupled to a new digital data acquisition system are also discussed briefly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The ATLAS Tile Calorimeter

TileCal is the Hadronic calorimeter covering the most central region of the ATLAS experiment at the LHC. It uses iron plates as absorber and plastic scintillating tiles as the active material. Scintillation light produced in the tiles is transmitted by wavelength shifting fibres to photomultiplier tubes (PMTs). The resulting electronic signals from the approximately 10000 PMTs are measured and digitised every 25 ns before being transferred to off-detector data-acquisition systems. This contribution will review in a first part the performances of the calorimeter during run 1, obtained from calibration data, and from studies of the response of particles from collisions. In a second part it will present the solutions being investigated for the ongoing and future upgrades of the calorimeter electronics. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual Design of Forced Convection Molten Salt Heat Transfer Testing Loop

This report develops a proposal to design and construct a forced convection test loop. A detailed test plan will then be conducted to obtain data on heat transfer, thermodynamic, and corrosion characteristics of the molten salts and fluid-solid interaction. In particular, this report outlines an experimental research and development test plan. The most important initial requirement for heat transfer test of molten salt systems is the establishment of reference coolant materials to use in the experiments. An earlier report produced within the same project highlighted how thermophysical properties of the materials that directly impact the heat transfer behavior are strongly correlated to the composition and impurities concentration of the melt. It is therefore essential to establish laboratory techniques that can measure the melt composition, and to develop purification methods that would allow the production of large quantities of coolant with the desired purity. A companion report describes the options available to reach such objectives. In particular, that report outlines an experimental research and development test plan that would include following steps: •Molten Salts: The candidate molten salts for investigation will be selected. •Materials of Construction: Materials of construction for the test loop, heat exchangers, and fluid-solid corrosion tests in the test loop will also be selected. •Scaling Analysis: Scaling analysis to design the test loop will be performed. •Test Plan: A comprehensive test plan to include all the tests that are being planned in the short and long term time frame will be developed. •Design the Test Loop: The forced convection test loop will be designed including extensive mechanical design, instrument selection, data acquisition system, safety requirements, and related precautionary measures. •Fabricate the Test Loop. •Perform the Tests. •Uncertainty Analysis: As a part of the data collection, uncertainty analysis will be performed to develop probability of confidence in what is measured in the test loop. Overall, the testing loop will allow development of needed heat transfer related thermophysical parameters for all the salts, validate existing correlations, validate measuring instruments under harsh environment, and have extensive corrosion testing of materials of construction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Neutron Interrogation System For Underwater Threat Detection And Identification

Wartime and terrorist activities, training and munitions testing, dumping and accidents have generated significant munitions contamination in the coastal and inland waters in the United States and abroad. Although current methods provide information about the existence of the anomaly (for instance, metal objects) in the sea bottom, they fail to identify the nature of the found objects. Field experience indicates that often in excess of 90% of objects excavated during the course of munitions clean up are found to be non-hazardous items (false alarm). The technology to detect and identify waterborne or underwater threats is also vital for protection of critical infrastructures (ports, dams, locks, refineries, and LNG/LPG). We are proposing a compact neutron interrogation system, which will be used to confirm possible threats by determining the chemical composition of the suspicious underwater object. The system consists of an electronic d-T 14-MeV neutron generator, a gamma detector to detect the gamma signal from the irradiated object and a data acquisition system. The detected signal then is analyzed to quantify the chemical elements of interest and to identify explosives or chemical warfare agents.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose aircraft monitoring with a smart recorder

This paper describes a microprocessor-based flight recorder the 'Smart Recorder' - which was developed and installed on a King Air aircraft used for commercial charter service. The recorder is used as a research tool for developing monitoring strategies and processing algorithms to: (1) characterize the typical flight environment encountered by the host aircraft, (2) develop technology for automated engine trend monitoring, and (3) implement a crash recording capability. Initially the recorder was used as an adaptive data acquisition system, monitoring engine sensors and flight instruments and then modifying its data acquisition in response to the perceived aircraft situation. Data collected in this manner were stored in a removable bubble memory and subsequently analyzed in the laboratory. Later, on-board processing was implemented to better utilize the available storage capacity.

White, J. H.↗

Design and performance of a respiratory amplitude gating device for PET/CT imaging

Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A system for testing airdata probes at high angles of attack using a ground vehicle

A system to calibrate airdata probes at angles of attack between 0 and 90 deg was developed and tested at the NASA Ames Dryden Flight Research Facility. This system used a test fixture mounted to the roof of a ground vehicle and included an onboard instrumentation and data acquisition system for measuring pressures and flow angles. The data could be easily transferred to the facility mainframe computer for further analysis. The system was designed to provide convenient and inexpensive airdata probe calibrations for projects which require airdata at high angles of attack, such as the F-18 High Alpha Research Program. This type of probe was tested to 90 deg angle of attack in a wind tunnel and using the ground vehicle system. The results of both tests are in close agreement. An airdata probe with a swiveling pilot-static tube was also calibrated with the ground vehicle system. This paper presents the results of these tests and gives a detailed description of the test system.

Geenen, Robert J.↗

Firmware lower-level discrimination and compression applied to streaming x-ray photon correlation spectroscopy area-detector data

We present a data acquisition system to perform on-the-fly background subtraction and lower-level discrimination compression of streaming x-ray photon correlation spectroscopy data from a fast charge-coupled device (CCD) area detector. The system is built using a commercial frame grabber with an on-board field-programmable gate array. The system is capable of continuously processing at least 60 CCD frames per second each consisting of 1024 x 1024 16-bit pixels with < or approx. 15 000 photon hits per frame at a maximum compression factor of {approx_equal}95%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NSLS-II: Nonlinear Model Calibration for Synchrotrons

This tech note is essentially a summary of a lecture we delivered to the Acc. Phys. Journal Club Apr, 2010. However, since the estimated accuracy of these methods has been naive and misleading in the field of particle accelerators, i.e., ignores the impact of noise, we will elaborate on this in some detail. A prerequisite for a calibration of the nonlinear Hamiltonian is that the quadratic part has been understood, i.e., that the linear optics for the real accelerator has been calibrated. For synchrotron light source operations, this problem has been solved by the interactive LOCO technique/tool (Linear Optics from Closed Orbits). Before that, in the context of hadron accelerators, it has been done by signal processing of turn-by-turn BPM data. We have outlined how to make a basic calibration of the nonlinear model for synchrotrons. In particular, we have shown how this was done for LEAR, CERN (antiprotons) in the mid-80s. Specifically, our accuracy for frequency estimation was {approx} 1 x 10{sup -5} for 1024 turns (to calibrate the linear optics) and {approx} 1 x 10{sup -4} for 256 turns for tune footprint and betatron spectrum. For a comparison, the estimated tune footprint for stable beam for NSLS-II is {approx}0.1. Since the transverse damping time is {approx}20 msec, i.e., {approx}4,000 turns. There is no fundamental difference for: antiprotons, protons, and electrons in this case. Because the estimated accuracy for these methods in the field of particle accelerators has been naive, i.e., ignoring the impact of noise, we have also derived explicit formula, from first principles, for a quantitative statement. For e.g. N = 256 and 5% noise we obtain {delta}{nu} {approx} 1 x 10{sup -5}. A comparison with the state-of-the-arts in e.g. telecomm and electrical engineering since the 60s is quite revealing. For example, Kalman filter (1960), crucial for the: Ranger, Mariner, and Apollo (including the Lunar Module) missions during the 60s. Or Claude Shannon et al since the 40s for that matter. Conclusion: what's elementary in the latter is considered 'advanced', if at all, in the former. It is little surprise then that published measurements typically contains neither error bars (for the random errors) nor estimates for the systematic in the former discipline. We have also showed how to estimate the state space by turn-by-turn data from two adjacent BPMs. And how to improve the resolution of the nonlinear resonance spectrum by Fourier analyzing the linear action variables instead of the betatron motion. In fact, the state estimator could be further improved by adding a Kalman filter. For transparency, we have also summarized on how these techniques provide a framework- and method for a TQM (Total Quality Management) approach for the main ring. Of course, to make the ($2.5M) turn-by-turn data acquisition system that is being implemented (for all the BPMs) useful, a means ({approx}10% contingency for the BPM system) to drive the beam is obviously required.

43 PARTICLE ACCELERATORS↗