Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data Base and Guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Real-time Erosion-Corrosion Detection in Waste Transfer Pipelines using Guided Wave Ultrasonic Sensors - 18368

A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the United States Department of Energy Hanford Site Tank Farm to examine structural parameters of the waste transfer systems in order to develop erosion/corrosion rates for relevant system components. The FFS information is acquired from opportunistic evaluations of pipelines that have been removed from service. The objective is to deliver more realistic estimates to the remaining useful life of the components and incorporate those estimates into future design/testing plans across the DOE complex. To aid to this objective, previous efforts at Hanford included the installation of sensors on some of the POR 104 components, to provide real time pipe wall thickness measurements. Due to certain limitations, alternative approaches for remote permanently mounted pipe wall ultrasonic thickness measurement systems have been investigated by FIU. Present research work is a supportive effort by FIU-ARC for DOE and WRPS, which investigates the option for remote-permanently mount guided wave ultrasonic transducer (UT) systems for HLW pipe wall thickness measurements. Specific applications include straight sections, elbows and other fittings used in jumper pits, evaporators, and valve boxes. The proposed method will provide information that will assist engineers with understanding the failure potential of HLW transfer components due to corrosion and erosion. This information can assist in determining if and when lines need to be removed, saving time and resources on the unneeded excavation of transfer lines. This information will also assist engineers with designing new transfer systems by establishing more detailed/accurate guidelines governing the life expectancy of the transfer system and its components. In the previous work, FIU has investigated the use of various ultrasonic systems that are either commercially available or used previously at Hanford and selected the most promising systems for further evaluation. The down-selected system is the guided wave UT sensor system from Permasense which is a UK based manufacturer. It is an integrated wireless sensor network system which used a patented technology for the acoustic wave propagation and has proven applications in the oil and gas industries. Scope of the present research includes the initial verification and validation of the Permasense Guided Wave sensor system as a potential erosion/corrosion detection system for carbon steel pipelines under static conditions. In future, the real-time erosion/corrosion detection will be investigated by measuring the thinning of the pipe sections by circulating simulants and continuous monitoring. This is achieved by passing abrasive and caustic solutions through an in-house designed pipe loop system. Results obtained provide realistic wear rates on 2 inch and 3 inch carbon steel pipes with straight sections and elbows using the Permasense UT sensor system. Thus, the present research delivers solutions for sensor evaluations, conducts bench scale testing followed by data acquisition and analysis for corrosion and erosion assessment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-CAMPUS-J-04: Image Guided Radiation Therapy (IGRT): Review of Technical Standards and Credentialing in Radiotherapy Clinical Trials

Purpose: To review IGRT credentialing experience and unexpected technical issues encountered in connection with advanced radiotherapy technologies as implemented in RTOG clinical trials. To update IGRT credentialing procedures with the aim of improving the quality of the process, and to increase the proportion of IGRT credentialing compliance. To develop a living disease site-specific IGRT encyclopedia. Methods: Numerous technical issues were encountered during the IGRT credentialing process. The criteria used for credentialing review were based on: image quality; anatomy included in fused data sets and shift results. Credentialing requirements have been updated according to the AAPM task group reports for IGRT to ensure that all required technical items are included in the quality review process. Implementation instructions have been updated and expanded for recent protocols. Results: Technical issues observed during the credentialing review process include, but are not limited to: poor quality images; inadequate image acquisition region; poor data quality; shifts larger than acceptable; no soft tissue surrogate. The updated IGRT credentialing process will address these issues and will also include the technical items required from AAPM: TG 104; TG 142 and TG 179 reports. An instruction manual has been developed describing a remote credentialing method for reviewers. Submission requirements are updated, including images/documents as well as facility questionnaire. The review report now includes summary of the review process and the parameters that reviewers check. We have reached consensus on the minimum IGRT technical requirement for a number of disease sites. RTOG 1311(NRG-BR002A Phase 1 Study of Stereotactic Body Radiotherapy (SBRT) for the Treatment of Multiple Metastases) is an example, here; the protocol specified the minimum requirement for each anatomical sites (with/without fiducials). Conclusion: Technical issues are identified and reported. IGRT guidelines are updated, with the corresponding credentialing requirements. An IGRT encyclopedia describing site-specific implementation issues is currently in development.

60 APPLIED LIFE SCIENCES↗

Water isotope data for the TEMPEST study site, 2023-2026

This dataset contains water isotope (deuterium (dD) and oxygen (d18O)) data from porewater, experimental source water, and aquifer sources from the Terrestrial Ecosystem Manipulation to Probe the Effects of Storm Treatments (TEMPEST) experimental field site in Edgewater, MD. Samples were taken from 2023-2026 and included in file "TEMPEST_Water_Isotope_LANL_2023-2026.csv". Porewater samples were taken from 15cm depth at multiple locations in each experimental plot (i.e., control, freshwater, and saltwater). Water samples were stored in 2 ml amber glass vials with septum caps under refrigeration until analysis. A L2140-i Picarro cavity ringdown spectrometer connected to an A0211 Picarro vaporization module was used to run water samples. Standards (United States Geological Survey (USGS) 47 and 48) were used to check instrument accuracy during each run of samples. Post-processing codes were run to calculate isotopic values from raw data. Reported isotope data is post-processed. Raw data CSV files from the Picarro were processed using a Python script and output as excel files containing data calibrated to Vienna Standard Mean Ocean Water (VSMOW). Standardization is based on USGS47 and USGS48 standards that are measured before and after every 5-10 unknowns. Every measurement is comprised of 10 injections. Processing involved discarding the first 4 injections due to a known memory effect. Raw means of the last 6 injections are taken for each measurement and then corrected from the linear calibration relationship of the USGS standards expected vs measured values to obtain corrected compositions relative to VSMOW. Reported isotope data are corrected mean results.

Aquifer↗

Wind turbine power production and annual energy production depend on atmospheric stability and turbulence

Using detailed upwind and nacelle-based measurements from a General Electric (GE) 1.5sle model with a 77 m rotor diameter, we calculate power curves and annual energy production (AEP) and explore their sensitivity to different atmospheric parameters to provide guidelines for the use of stability and turbulence filters in segregating power curves. The wind measurements upwind of the turbine include anemometers mounted on a 135 m meteorological tower as well as profiles from a lidar. We calculate power curves for different regimes based on turbulence parameters such as turbulence intensity (TI) as well as atmospheric stability parameters such as the bulk Richardson number ( R B ). We also calculate AEP with and without these atmospheric filters and highlight differences between the results of these calculations. The power curves for different TI regimes reveal that increased TI undermines power production at wind speeds near rated, but TI increases power production at lower wind speeds at this site, the US Department of Energy (DOE) National Wind Technology Center (NWTC). Similarly, power curves for different R B regimes reveal that periods of stable conditions produce more power at wind speeds near rated and periods of unstable conditions produce more power at lower wind speeds. AEP results suggest that calculations without filtering for these atmospheric regimes may overestimate the AEP. Because of statistically significant differences between power curves and AEP calculated with these turbulence and stability filters for this turbine at this site, we suggest implementing an additional step in analyzing power performance data to incorporate effects of atmospheric stability and turbulence across the rotor disk.

17 WIND ENERGY↗

Signal Processing Methods for Liquid Rocket Engine Combustion Stability Assessments

The J2X Gas Generator engine design specifications include dynamic, spontaneous, and broadband combustion stability requirements. These requirements are verified empirically based high frequency chamber pressure measurements and analyses. Dynamic stability is determined with the dynamic pressure response due to an artificial perturbation of the combustion chamber pressure (bomb testing), and spontaneous and broadband stability are determined from the dynamic pressure responses during steady operation starting at specified power levels. J2X Workhorse Gas Generator testing included bomb tests with multiple hardware configurations and operating conditions, including a configuration used explicitly for engine verification test series. This work covers signal processing techniques developed at Marshall Space Flight Center (MSFC) to help assess engine design stability requirements. Dynamic stability assessments were performed following both the CPIA 655 guidelines and a MSFC in-house developed statistical-based approach. The statistical approach was developed to better verify when the dynamic pressure amplitudes corresponding to a particular frequency returned back to pre-bomb characteristics. This was accomplished by first determining the statistical characteristics of the pre-bomb dynamic levels. The pre-bomb statistical characterization provided 95% coverage bounds; these bounds were used as a quantitative measure to determine when the post-bomb signal returned to pre-bomb conditions. The time for post-bomb levels to acceptably return to pre-bomb levels was compared to the dominant frequency-dependent time recommended by CPIA 655. Results for multiple test configurations, including stable and unstable configurations, were reviewed. Spontaneous stability was assessed using two processes: 1) characterization of the ratio of the peak response amplitudes to the excited chamber acoustic mode amplitudes and 2) characterization of the variability of the peak response's frequency over the test duration. This characterization process assists in evaluating the discreteness of a signal as well as the stability of the chamber response. Broadband stability was assessed using a running root-mean-square evaluation. These techniques were also employed, in a comparative analysis, on available Fastrac data, and these results are presented here.

Kenny, R. Jeremy↗

Final Status of HEPA Filter 10-Year Lifetime Evaluation

High-efficiency particulate air (HEPA) filters are widely employed by nuclear facilities to remove radiological particulate matter from their effluent exhaust streams. The purpose of this study is to evaluate the relationships between the 10-year HEPA filter lifespan and its other performance indicators. The 10-year-long endeavor to collect and analyze data regarding the lifetime of HEPA filters at the Pacific Northwest National Laboratory began in 2010. Forty-nine HEPA filters were selected and have been surveyed and analyzed at least annually to verify compliance with permit conditions. The study suggests the frequency of filter replacement should be based on the actual operational requirements, such as fume hood face velocity and/or efficiency test results, instead of on the prescribed filter “age limit” of 10 years from the date of manufacture (e.g., birth date) when operating under dry conditions. Over the past decade, the study has now been completed, and all forty-nine HEPA filters have been replaced, due to either technical issues listed in this report, or the previously recommended filter “age limit” of 10 years.

61 RADIATION PROTECTION AND DOSIMETRY↗

Myocardial perfusion imaging in women for the evaluation of stable ischemic heart disease—state-of-the-evidence and clinical recommendations

This document from the American Society of Nuclear Cardiology represents an updated consensus statement on the evidence base of stress myocardial perfusion imaging (MPI), emphasizing new developments in single-photon emission tomography (SPECT) and positron emission tomography (PET) in the clinical evaluation of women presenting with symptoms of stable ischemic heart disease (SIHD). The clinical evaluation of symptomatic women is challenging due to their varying clinical presentation, clinical risk factor burden, high degree of comorbidity, and increased risk of major ischemic heart disease events. Evidence is substantial that both SPECT and PET MPI effectively risk stratify women with SIHD. The addition of coronary flow reserve (CFR) with PET improves risk detection, including for women with nonobstructive coronary artery disease and coronary microvascular dysfunction. With the advent of PET with computed tomography (CT), multiparametric imaging approaches may enable integration of MPI and CFR with CT visualization of anatomical atherosclerotic plaque to uniquely identify at-risk women. Radiation dose-reduction strategies, including the use of ultra-low-dose protocols involving stress-only imaging, solid-state detector SPECT, and PET, should be uniformly applied whenever possible to all women undergoing MPI. Appropriate candidate selection for stress MPI and for post-MPI indications for guideline-directed medical therapy and/or invasive coronary angiography are discussed in this statement. The critical need for randomized and comparative trial data in female patients is also emphasized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study of Future Communications Concepts and Technologies for the National Airspace System-Part III

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) is investigating current and anticipated wireless communications concepts and technologies that the National Airspace System (NAS) may need in the next 50 years. NASA has awarded three NASA Research Announcements (NAR) studies with the objective to determine the most promising candidate technologies for air-to-air and air-to-ground data exchange and analyze their suitability in a post-NextGen NAS environment. This paper will present progress made in the studies and describe the communications challenges and opportunities that have been identified as part of the study. NASA's NextGen Concepts and Technology Development (CTD) Project integrates solutions for a safe, efficient and high-capacity airspace system through joint research efforts and partnerships with other government agencies. The CTD Project is one of two within NASA's Airspace Systems Program and is managed by the NASA Ames Research Center. Research within the CTD Project is in support the 2011 NASA Strategic Plan Sub-Goal 4.1: Develop innovative solutions and advanced technologies, through a balanced research portfolio, to improve current and future air transportation. The focus of CTD is on developing capabilities in traffic flow management, dynamic airspace configuration, separation assurance, super density operations and airport surface operations. Important to its research is the development of human/automation information requirements and decisionmaking guidelines for human-human and human-machine airportal decision-making. Airborne separation, oceanic intrail climb/descent and interval management applications depend on location and intent information of surrounding aircraft. ADS-B has been proposed to provide the information exchange, but other candidates such as satellite-based receivers, broadband or airborne internet, and cellular communications are possible candidate's.

Navigation↗

Overview of the Subscale RAVEN Flight Controls and Modeling Testbed

The Research Aircraft for eVTOL Enabling TechNologies (RAVEN) Subscale Wind-Tunnel and Flight Test (SWFT) model is a subscale aircraft built for flight dynamics and controls research demonstrated in wind-tunnel and flight-test experiments. The intent of this paper is to provide a summary of past, current, and future efforts being pursued by the RAVEN-SWFT project. Initially, vehicle development guidelines were crafted by a multidisciplinary team to ensure that the RAVEN-SWFT vehicle was well suited for research in multiple areas, including aero-propulsive modeling, flight controls, and autonomy, among others. The vehicle has been used to obtain extensive wind-tunnel data, enabling aero-propulsive model development across the transition flight envelope and validation of computational tools. The vehicle will be used to conduct flight testing in order to evaluate modeling strategies and flight control logic. The RAVEN-SWFT model also serves as a risk reduction activity for a conceptual, full-scale vehicle in the 1000-lb class. The next steps in the project are to successfully demonstrate free flight in hover, transition, forward flight, and the reverse thereof, utilizing custom control laws integrated onto the RAVEN-SWFT avionics hardware. The project intends to publicize all of the geometry, data, and methods in future reports.

eVTOL↗

Data from: "Towards CONUS-Wide ML-Augmented Conceptually-Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics"

This data package was generated to support the manuscript “Towards CONUS-Wide Machine Learning-Augmented Conceptually Interpretable Modeling of Catchment-Scale Precipitation-Storage-Runoff Dynamics.” It provides input files, model outputs, plotting data, scripts, notebooks, and documentation used to develop, evaluate, and reproduce Mass-Conserving Perceptron (MCP)-based hydrologic modeling experiments across 513 selected Catchment Attributes and Meteorology for Large-sample Studies in the United States (CAMELS-US) basins. The files are organized by modeling component and analysis purpose, including rainfall–runoff experiments, snow module experiments, coupled hydrologic-snow experiments, Long Short-Term Memory (LSTM) benchmark results, model skill metrics, initialization and epoch records, cell-state normalization files, Akaike Information Criterion (AIC)-based model comparison files, and data used to generate manuscript figures. Tabular files can be opened using standard spreadsheet software or Python/R data-analysis tools. Python scripts, Jupyter notebooks, and selected MATLAB scripts are included for model execution, postprocessing, plotting, and statistical analysis. Quality assurance and quality control were conducted through the source-data selection and modeling workflow. Meteorological forcing, streamflow, and static catchment attributes were derived from the CAMELS-US dataset, and snow water equivalent data were derived from the University of Arizona (UA) Snow Water Equivalent dataset. Selected basins and time periods were screened during the associated research workflow to avoid missing observations or poor-quality cases. Static geospatial features were processed primarily using Quantum Geographic Information System (QGIS) and Geospatial Data Abstraction Library (GDAL) workflows. Additional details are provided in the associated manuscript and documentation.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Wake Vortex Tracking Using a 35 GHz Pulsed Doppler Radar

A 35 GHz, pulsed-Doppler radar system has been designed and assembled for wake vortex detection and tracking in low visibility conditions. Aircraft wake vortices continue to be an important factor in determining safe following distances or spacings for aircraft in the terminal area. Currently, under instrument meteorological conditions (IMC), aircraft adhere to conservative, fixed following-distance guidelines based primarily on aircraft weight classifications. When ambient conditions are such that vortices will either drift or dissipate, leaving the flight corridor clear, the prescribed spacings are unnecessarily long and result in decreased airport throughput. There is a potential for significant airport efficiency improvement, if a system can be employed to aid regulators and pilots in setting safe and efficient following distances based on airport conditions. The National Aeronautics and Space Administration (NASA), the Federal Aviation Agency, and Volpe National Transportation Systems Center have promoted and worked to develop systems that would increase airport capacity and provide for safe reductions in aircraft separation. The NASA Aircraft Vortex Spacing System (AVOSS), a wake vortex spacing system that can provide dynamic adjustment of spacings based on real-time airport weather conditions, has demonstrated that Lidar systems can be successfully used to detect and track vortices in clear air conditions. To fill the need for detection capability in low-visibility conditions, a 35 GHz, pulsed-Doppler radar system is being investigated for use as a complimentary, low-visibility sensor for wake vortices. The radar sensor provides spatial and temporal information similar to that provided by Lidar, but under weather conditions that a Lidar cannot penetrate. Currently, we are analyzing the radar design based upon the data and experience gained during the wake vortex Lidar deployment with AVOSS at Dallas/Fort Worth International Airport. As part of this study, two numerical models were utilized in system simulations. The results of this study improve our understanding of the method of detection, resolution requirements for range and azimuth, pulse compression, and performance prediction. Simulations applying pulse compression techniques show that detection is good in heavy fog to greater than 2000 m. Both compressed and uncompressed short pulses show the vortex structure. To explore operational challenges, siting and scanning strategies were also analyzed. Simulation results indicate that excellent wake vortex detection, tracking and classification is possible in drizzle (+15 dBZ) and heavy fog (- 13 dBZ) using short pulse techniques (<99ns) at ranges on the order of 900 m, with a modest power of 500 W output. At 1600 m, detection can be expected at reflectivities as low as -13 dBZ (heavy fog). The radar system, as designed and built, has the potential to support field studies of a wake vortex spacing system in low-visibility conditions ranging from heavy fog to rain, when sited within 2000m of the flight path.

Neece, Robert T.↗

Challenges and Practical Solutions for Conducting Structural MARSSIM Surveys in Elevated Radon Environments - 20413

The Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) [1] provides comprehensive guidance for the development and implementation of radiological surveys conducted to demonstrate compliance with a dose- or risk-based cleanup goal during final status survey. The MARSSIM methodology follows an integrated strategy combining direct measurements and sampling to assess uniform residual contamination, and scanning surveys to identify localized areas of elevated activity. Building surveys assessing residual surface contamination present unique challenges from reliance on field measurements that may be subject to less than ideal environmental conditions. Additionally, limited characterization and excessive conservatism incorporated into the conceptual site model may result in derived concentration guideline levels (DCGL) and, as a consequence of relatively inefficient field instrumentation, corresponding attributable count rates generally comparable to background. The presence of elevated ambient radon concentrations and associated progeny deposition both exacerbate these intrinsic survey challenges and introduce a series of technical, logistic, and administrative obstacles that can wreak havoc on the statistical legitimacy of each component of the MARSSIM process. Short-lived radon progeny including polonium-218, lead-214, bismuth-214, and polonium-214 produce excessive alpha and beta radiation that may decrease instrument sensitivity through an increase in background count rates, and, at worst, may result in incorrect survey unit failure through the simulation of residual surface activity. Aside from the obvious solution of exhaustive radon mitigation, the primary objectives are to distinguish between radon progeny deposition and actual surface activity, and collect sufficient defensible data. The following is a technical discussion of the consequences of performing building MARSSIM surveys in the presence of elevated ambient radon atmospheres, conceptual examples, and an overview of practical strategies to minimize the effects of radon interference while collecting sufficient defensible data to complete the survey. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluating Age Effects on HEPA Filter Performance

Nuclear grade high efficiency particulate air (HEPA) filters are routinely employed as the final control element in confinement ventilation systems. The traditional HEPA filter utilizes a pleated filter medium of fibrous glass that has been produced in a manner analogous to manufacturing paper. These filters are the physically weakest element in a containment ventilation system. Containment ventilation systems are designed to condition the air-stream (temperature, relative humidity, moisture, particle size distribution of aerosols, and aerosol concentration) to levels/conditions that fibrous glass HEPA filters can handle. Approximately 6000 nuclear grade HEPA filters are purchased each year for use in the DOE/NNSA complex. Additional filters are purchased for use in commercial nuclear power generation and ventilation systems of other nuclear applications. These filters are designed and tested in accordance with the American Society of Mechanical Engineers (ASME) AG-1 Code Nuclear Air and Gas Treatment. This code establishes design requirements and qualification procedures. Qualification testing of axial flow filters is described in paragraphs 5000 and following of AG-1. The series of qualification tests are intended to describe the operating envelope of HEPA filters and verify the reliability of a filter design. AG-1 qualification also confirms the pedigree of components used in manufacture for that filter design. The collective set of qualification tests establishes the assumed operating envelope for AG-1 filters. The effects of age on HEPA filter performance have been a concern for at least two decades. A combination of physical evaluation of aged filter media and a review of filter failure records resulted in Appendix C of the Nuclear Air Cleaning Handbook (NACH), Determination of HEPA Filter Life. This states that HEPA filters are not to be used beyond 10 years from the date of manufacture. Additionally, filters put into service in locations where they may become wet are to be taken out of service five years from date of manufacture. Filters that have become wet are to be taken out of service immediately. Finally, it should also be pointed out that filters held in Level B storage are subject to the same 10-year service life. Very limited bench-scale testing in the 1990's raised concern that aging HEPA filters do not have the strength to withstand an accident scenario. In May of 1999, the DNFSB released a Technical Report 23 entitled HEPA Filters Used in the Department of Energy's Hazardous Facilities. This report expressed concerns for the potential vulnerability of HEPA filters in vital safety systems. Concerns and uncertainty associated with degradation of HEPA filter performance over time led the DOE sites to limit HEPA filter service life to 10 years from the date of manufacture or five years in cases where filters may become wet. Establishment of a conservative service life needs to be based on data from a structured series of tests comparing the performance envelope of new and aged full-scale filters. A service life that is insufficiently conservative endangers workers and the public. One that is excessively conservative costs can cause hundreds of otherwise unnecessary filter changes. This increases exposure of employees, disrupts facility operations, and increase disposal costs by millions of dollars annually. Conclusive data are needed to resolve uncertainty associated with the damaging effects of aging on durability of HEPA filters. Therefore, this study needs to provide a sufficient body of evidence to allow DOE and site professionals to make prudent decisions. An updated version of ASME AG-1 Section FC included a non-mandatory appendix that would include the DOE guidance for service life of HEPA filters. Balloting of this revision generated significant resistance to inclusion of any kind of service life language citing the lack of supporting experimental data. Efforts to resolve negative votes failed and resistance to acceptance of the language increased. The result has been to not include service language in Section FC and requests to remove it from sections that already include such language. The recent activity of the ASME AG-1 Committee on Nuclear Air and Gas Treatment effectively de-emphasizes following DoE's service life guidelines. The DOE Office of Nuclear Safety under its NSR and D program provided the Mississippi State University Institute for Clean Energy Technology (ICET) finding to initiate a study to determine the effects of aging on AG-1 axial flow filters just prior to actions taken within the AG-1 committee regarding service life. The NSR and D funding facilitated timely development of a national technical working group comprised of members from the regulatory community, DOE complex, and commercial power to resolve uncertainty associated with effects of aging. The Department of Energy Office of Environmental Management (DOE-EM) has been funding the ICET to evaluate the performance envelope for AG-1 HEPA filters. ICET is one of DOE-EM's qualified suppliers. Synergy has been achieved by associating the NSR and D aged filter activities to testing activities evaluating the performance envelopes of separator and separator-less AG-1 HEPA filters funded by DOE-EM. The DOE-EM funded activities establish baseline data for the aged filter study and future EM funding will provide long term support for testing additional aged filters. EM funding of new filters includes analytical evaluation of media tensile strength by thermal analysis to establish baseline values and determine mass loss of moisture resistance and acrylic binders due to use. All of these values can be used for comparison of test results for aged filters. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Leaf-area index of Oak-Hickory Forest at Missouri Ozark (MOFLUX) site: 2007–2022

This data set contains measurements of leaf-area index (LAI) at the Missouri Ozark (MOFLUX) site during growing seasons from 2007-2022. The MOFLUX site is located in the University of Missouri Baskett Forest, a second growth oak-hickory forest situated in the Ozark Border Region of central Missouri, USA. MOFLUX is part of the AmeriFlux network (site ID: US-MOz) and an eddy covariance tower marks the middle of the site (Figure 1). During 2003, 24 circular vegetation plots (each 0.08 hectares) were established within a ~250 meter (m) radius around the tower. The plots were situated 50 m apart along 5 linear transects radiating out from the flux tower base in southeast, south, southwest, west, and northwest directions. There were 5 plots per transect except for the northwest one, which had only 4 due to the presence of a small pond at the terminus. At weekly intervals during the growing season, leaf-area index measurements were taken within each vegetation plot on the 5 transects running from the central flux tower. A plant canopy analyzer (model LAI-2000 Li-Cor Inc., Lincoln NE) was used to make the LAI measurements. We collected samples to enable measurement of the mean LAI of each transect. LAI observations are useful for understanding vegetation phenology, and to aid in the interpretation of ecosystem gas exchange. This dataset contains one data file in comma separate (.csv) format. Additional metadata are provided: one data dictionary and a file-level metadata file in comma separate (.csv) format and a user guide in PDF (*.pdf) format.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Artificial Intelligence (AI) Methods for Augmenting the IMPACT Tool Evidence Library

Development of the Evidence Library for use with the IMPACT probability risk assessment tool took several years and involved a staggering amount of effort from a multi-disciplinary team. A very significant amount of the labor effort to collect, assess and finalize the Clinical Finding Form (CliFF) for each of the 119 medical conditions was provided by physician subject matter experts from the Exploration Medical Capability (ExMC) Element Clinical and Science Team. Many AI tools such as ChatGPT are excellent at summarizing large amounts of information and the current project was initiated to determine how such tools might streamline laborious processes, e.g., review and summarization of many scientific research publications, to execute key steps more efficiently in the process of developing CliFFs. The process for collecting the evidence which is found in the CliFFs is well documented in the Evidence Library Methods document (ELM; HRP-48036*). Using ELM and the CliFF development instructions as a guideline, a team of developers is leveraging Microsoft Azure AI tools and services along with open-source frameworks, to construct an AI-assisted automated pipeline. This pipeline is designed to search, retrieve, and process the necessary data sources, and ultimately help generate the final version of a CliFF. Currently, the large language model evaluates the relevance of each source material to spaceflights, either as direct evidence or as an analog. Additionally, the model assists in extracting keywords and generating brief summaries to enhance augmented retrieval and search processes in later stages of CliFF development. Once the data is ready, the model can perform semantic search and retrieval, generating and extracting valuable information for the CliFF. For instance, it can handle epidemiological statistical data, such as incidence rates and the likelihood of best or worst-case scenarios. The steps that required reading and summarizing articles were viewed as providing the greatest return on investment since large language models are very efficient and accurate in summarizing large amounts of text. Since labor effort to complete the original CliFF was not recorded with sufficient granularity, comparisons with an AI tool-generated CliFF will provide merely an approximation of time saved. Upon completion of the process, the CliFF for the medical condition “appendicitis” generated with the support of AI-based methods will serve as a proof-of-concept and will be compared to the original appendicitis CliFF to determine if use of the tools resulted in content and conclusory similarity. Based upon the results from face validation of the two CliFFs, modifications to the process will be made if necessary and additional condition CliFFs will be evaluated. Ultimately, CliFFs for the entire set of medical conditions will be created with the assistance of AI tools. Depending on the cost savings realized, CliFFs for additional medical conditions can be created to expand the Evidence Library. Future direction includes specifying the characteristics of the reviewer (prompting the AI tools to generate output assuming the reviewer is a sub-specialist physician, or nurse or EMT/medic) to determine if the effects on AI-generated output are different based on knowledge, skills and abilities. *Exploration Medical Capability Evidence Library Methods, HRP-48036 Rev A, July 2022.

Ali Al↗

Evaluation of atlas-based auto-segmentation software in prostate cancer patients

The performance and limitations of an atlas-based auto-segmentation software package (ABAS; Elekta Inc.) was evaluated using male pelvic anatomy as the area of interest. Contours from 10 prostate patients were selected to create atlases in ABAS. The contoured regions of interest were created manually to align with published guidelines and included the prostate, bladder, rectum, femoral heads and external patient contour. Twenty-four clinically treated prostate patients were auto-contoured using a randomised selection of two, four, six, eight or ten atlases. The concordance between the manually drawn and computer-generated contours were evaluated statistically using Pearson's product–moment correlation coefficient (r) and clinically in a validated qualitative evaluation. In the latter evaluation, six radiation therapists classified the degree of agreement for each structure using seven clinically appropriate categories. The ABAS software generated clinically acceptable contours for the bladder, rectum, femoral heads and external patient contour. For these structures, ABAS-generated volumes were highly correlated with ‘as treated’ volumes, manually drawn; for four atlases, for example, bladder r = 0.988 (P < 0.001), rectum r = 0.739 (P < 0.001) and left femoral head r = 0.560 (P < 0.001). Poorest results were seen for the prostate (r = 0.401, P < 0.05) (four atlases); however this was attributed to the comparison prostate volume being contoured on magnetic resonance imaging (MRI) rather than computed tomography (CT) data. For all structures, increasing the number of atlases did not consistently improve accuracy. ABAS-generated contours are clinically useful for a range of structures in the male pelvis. Clinically appropriate volumes were created, but editing of some contours was inevitably required. The ideal number of atlases to improve generated automatic contours is yet to be determined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduction in total and major cause-specific mortality from tobacco smoking cessation: a pooled analysis of 16 population-based cohort studies in Asia

Little is known about the time course of mortality reduction following smoking cessation in Asians who have smoking behaviours distinct from their Western counterparts. We evaluated the level of reduction in all-cause, cardiovascular disease (CVD) and lung cancer mortality by years since quitting smoking, in Asia. Using Cox regression, we analysed individual participant data (n = 709 151) from 16 prospective cohorts conducted in China, Japan, Korea/Singapore, and India/Bangladesh, separately by cohorts. Cohort-specific hazard ratios (HRs) were combined using a random-effects meta-analysis. During a mean follow-up of 12.0 years, 108 287 deaths were ascertained—35 658 from CVD and 7546 from lung cancer. Among Asian men, a dose-response relationship of risk reduction in deaths from all causes, CVD and lung cancer was observed with an increase in years after smoking cessation. Compared with never smokers, however, all-cause and CVD mortality among former smokers remained elevated 10–14 years after quitting [multivariable-adjusted HR (95% confidence interval (CI) = 1.25 (1.13–1.37) and 1.20 (1.02–1.41), respectively]. Lung cancer mortality stayed almost 2-fold higher than among never smokers 15–19 years after smoking cessation [1.97 (1.41–2.73)], particularly among former heavy smokers [2.62 (1.71–4.00)]. Women who quitted for ≥5 years retained a significantly elevated mortality from all causes, CVD and lung cancer. Overall patterns of the cessation-mortality associations were similar across countries. Our findings suggest that adverse effects of tobacco smoking persist for an extended time period, even for more than two decades, which is beyond the time windows defined in current clinical guidelines for risk assessment of lung cancer and CVD.

Public, Environmental & Occupational Health↗