Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Development of near-optimal advanced control sequences for chiller plants with water-side economizers in U.S. Climates (ASHRAE RP-1661)

Various advanced control sequences for chiller plants with water-side economizers (WSE) have been proposed in literature, but the evaluation and optimization of those controls is limited. It is possible to maximize energy savings by selecting different sequences and related parameters based on the plant configuration, load, and climate. This paper addresses this gap by developing near-optimal advanced control sequences for chiller plants with WSEs. First, advanced control sequences for chiller plants with WSEs are categorized into condenser water, chilled water, and hybrid controls and representative sequences from each category are identified. Next, 504 different scenarios are optimized. These scenarios represent all possible combinations of two plant configurations, a constant or variable load profile, three advanced control sequences, and seven optimization parameter combinations in six climate zones. The results show the recommended near-optimal sequences can reduce energy consumption by up to 15% relative to the baseline depending on the configuration, load profile, and climate. Specifically, the CW-CHW sequence is recommended for the majority of systems because it is often the most energy efficient and/or reduces the runtime of chillers. The methodology in this paper provides practical guidance for achieving energy savings through near-optimal control of chiller plants with WSEs.

42 ENGINEERING↗

Simultaneous stabilization and control of the n = 1 and n = 2 resistive wall mode

Abstract DIII-D experiments demonstrate simultaneous stability measurements and control of resistive wall modes (RWMs) with toroidal mode numbers n = 1 and n = 2. RWMs with n > 1 are sometimes observed on DIII-D following the successful feedback stabilization of the n = 1 mode, motivating the development of multi- n control. A new model-based multi-mode feedback algorithm based on the VALEN physics code has been implemented on the DIII-D tokamak using a real-time GPU installed directly into the DIII-D plasma control system. In addition to stabilizing RWMs, the feedback seeks to control the stable plasma error field response, enabling compensation of the typically unaddressed DIII-D n = 2 error field component. Experiments recently demonstrated this algorithm’s ability to simultaneously control n = 1 and n = 2 perturbed fields for the first time in a tokamak, using reactor relevant external coils. Control was maintained for hundreds of wall-times above the n = 1 no-wall pressure limit and approaching the n = 1 and n = 2 ideal-wall limits. Furthermore, a rotating non-zero target was set for the feedback, allowing stability to be assessed by monitoring the rotating plasma response (PR) while maintaining control. This novel technique can be viewed as a closed-loop extension of active MHD spectroscopy, which has been used to validate stability models through comparisons of the PR to applied, open-loop perturbations. The closed-loop response measurements are consistent with open-loop MHD spectroscopy data over a wide range of β N approaching the n = 1 ideal-wall limit. These PR measurements were then fit to produce both VALEN and single-mode stability models. These models allowed for important plasma stability information to be determined and have been shown to agree with experimentally observed RWM growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Unified ELM Suppression on KSTAR and DIII-D via Adaptive Feedback Control Strategies

This paper reports on the extension of our amplitude-based resonant magnetic perturbation (RMP) edge localized mode (ELM) controller to support phasing control (relative toroidal phases of RMP waveforms between rows of coils), multiple toroidal mode numbers, and new ‘jump’ and ‘probing’ strategies, all deployed on KSTAR and DIII-D. By treating the control algorithm as device-independent and adjusting only the real-time interfaces to sensors and power supplies, we have confirmed that the same finite state machine—based feedback logic can be ported between machines with minor modifications. In experiments using n = 2 RMPs on KSTAR and n = 3 on DIII-D, the controller successfully modulated RMP amplitudes in real time to sustain ELM suppression while minimizing confinement degradation. Phasing control broadened the suppression window, as it permitted the system to avoid locked-mode regions and safely access ELM-free conditions. A rotating RMP phasing scheme, integrated into the same framework, distributes divertor heat loads more uniformly, making it a promising strategy for protecting plasma-facing components during long discharges. New ‘jump’ and ‘probing’ techniques demonstrate the possibility for the controller to preempt imminent ELMs and refine the minimum required RMP amplitude without returning to ELMy conditions. Taken together, these upgrades enable extended ELM-free operation while mitigating confinement degradation, providing a practical framework for real-time ELM control in future high-performance tokamaks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An Update to the National Renewable Energy Laboratory Baseline Wind Turbine Controller

The National Renewable Energy Laboratory's 5-MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the 5-MW wind turbine uses a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into fast-paced development cycles, as systems engineering tools such as Wind-Plant Integrated System Design & Engineering Model (WISDEM ®) [1] are employed, and as a greater focus on controls co-design practices is encouraged, demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5-MW controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process while maintaining or improving the performance of the legacy NREL 5-MW controller.

17 WIND ENERGY↗

Analysis of Long-Term Quality Control Data for a 137 Cs Dosimetry Calibration Source

Strict quality assurance programs are required for many radiological applications, but these seldom exist for verifying dosimetry calibration sources. After initial characterization of a dosimetry calibration facility, quality control procedures are recommended to ensure the early detection of any changes or malfunctions. These also result in refined knowledge about average dose rate and experimental variations in dose delivery. This paper describes the implementation of a phase I quality control protocol for a 137 Cs dosimetry calibration source and includes an analysis of the resulting data collected over a 24-mo period. During this time, substantial data was collected to establish trial control limits. Air kerma rate measurements were obtained using an ion chamber and were adjusted for decay, corrected for ambient temperature, pressure and humidity, and then analyzed using quality control charts. Three variations of rational subgrouping methods were used in order to find assignable causes of error, and Nelson's Rules were followed to detect any non-random statistical variations. Measurements were subgrouped according to same-day measurements in order to detect positional errors as well as atmospheric correction errors. Additionally, measurements were subgrouped according to analogous experimental setups in order to detect failure in equipment or incorrect settings. Both were analyzed using the X-bar and R chart method. Similarly, individuals and moving ranges charts were used to carefully examine each position in order to observe any situational errors that may occur which include timing, positional, or interference errors. Each method was successful in identifying unique out-of-control data points that occurred during the phase I application of forming control limits. Furthermore, over the 24-mo period, enough data points were deemed in-control to establish reliable trial limits. Future experiments will include the phase II application of gaining more reliable measurements in order to fine-tune the limits, as well as performing a designed experiment, where variables are purposefully changed in order to test the variation of the data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Data-driven modeling and control of an X-ray bimorph adaptive mirror

Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Lyapunov-Based Generalized Dc-Side Controller Design for PV-Connected Systems

The objective of this paper is to realize a universal dc-side controller for photovoltaic (PV) systems where the control is agnostic to the downstream converter configuration. To achieve this, the downstream power converter and its controls are manipulated into an effective power control loop that is then cast into a generalized multi-loop design framework. On the dc side, a nonlinear small-signal model of the PV input is realized exclusively in terms of PV datasheet parameters (i.e., open-circuit voltage, short-circuit current, and maximum power point). Finally, a linear controller is used to modulate the dc-side PV system with the generic downstream power controller. A Lyapunov candidate is proposed to analyze the stability of the interconnected system and provide a streamlined approach for the controller design. The proposed design is validated on a 1k VA experimental setup that interfaces a PV module to the grid.

generalized PV controller↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Voltage Control Analysis for Heavy-Duty Electric Vehicle Charging Stations

This paper presents an analysis of grid voltage control strategies for heavy-duty electric vehicle charging stations. The performance of three voltage control approaches—including power factor control, standardized volt-volt ampere reactive (VAR) curve control, and customized volt-VAR curve control—are investigated and evaluated for three different sizes of charging stations, including a single-port charging station, a midsized three-port charging station, and six-port travel center. The charging stations are placed on multiple locations of four different types of distribution systems to obtain a comprehensive performance analysis of the voltage control approaches under different scenarios. To quantitively compare the performance of the three voltage control approaches, a series of metrics are designed to quantify the performance and contribute to the comprehensive analysis.

47 OTHER INSTRUMENTATION↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Comments on Control of Wave Energy Converters

The main objective of this letter is to consolidate the knowledge about the dynamics and control of oscillating-body wave energy converters (WECs). A number of studies have shown that control systems strongly affect power absorption; however, there remains a need for a concise and integrated explanation of the theoretical and practical implications that control can have on both performance and the broader WEC design process. This short letter attempts to fill this gap by presenting a discussion on the key practical aspects concerning the dynamics and control of oscillating-body WEC. In particular, the focus is on the choice of control models and a simple causal control scheme suitable for real-time implementation. To conclude, consideration is given to the effect of the power takeoff (PTO) on the maximization of electrical power, thus leading to the derivation of useful conditions for the control co-design of the PTO system.

42 ENGINEERING↗

Model Predictive Control-Based Dual-Mode Operation of an Energy-Stored Quasi-Z-Source Photovoltaic Power System

The energy-stored quasi-Z-source inverter (ES-qZSI) has attracted much attention for photovoltaic (PV) power generations, due to its capability to stabilize the PV power fluctuations with simple structure and other advantages of Z-source inverter. The improved dual-mode (DM) ES-qZSI is able to support all-weather operation even at night or cloudy days when PV power is extremely low. However, the traditional proportional–integral (PI) based control suffers from complicated controller design and poor dynamic response during mode transition, due to two sets of PI control required for the daytime and night operation modes. In order to overcome that, here in this article, we propose a model predictive control strategy for the DM-ES-qZSI PV power system. The system predictive models in both day and night operating modes are derived. The control strategy is disclosed to ensure high performance of the system, through calling the predictive models and defined cost functions of the two modes within a single control loop. Simulation and experiment are carried out to verify the effectiveness of the proposed control strategy.

14 SOLAR ENERGY↗

Iterative Learning Control for Video-rate Atomic Force Microscopy

We present a control scheme for video-rate atomic force microscopy with rosette pattern. The controller structure involves a feedback internal-model-based controller and a feedforward iterative learning controller. The iterative learning controller is designed to improve tracking performance of the feedback-controlled scanner by rejecting the repetitive disturbances arising from the system nonlinearities. We investigate the performance of two inversion techniques for constructing the learning filter. We conduct tracking experiments using a two-degree-of-freedom microelectromechanical system (MEMS) nanopositioner at frame rates ranging from 5 to 20 frames per second. Furthermore, the results reveal that the algorithm converges rapidly and the iterative learning controller significantly reduces both the transient and steady-state tracking errors. We acquire and report a series of high-resolution time-lapsed video-rate AFM images with the rosette pattern.

42 ENGINEERING↗

Flux Balancing Control of Ungapped Nanocrystalline Core-Based Transformer in Dual Active Bridge Converters

Transformer flux dc bias is a critical issue, impacting the reliable operation of dual active bridge (DAB) converters especially when ungapped high permeability nanocrystalline core is used. Steady state current dc bias can easily saturate ungapped nanocrystalline transformers, and it is even more dangerous in transient conditions. A dc bias model is proposed to analyze steady state dc bias in different load conditions. The magnetizing current detection is necessary for closed-loop control of dc bias; conductors' position is shown to impact sensor noise, and it is analyzed in detail. To deal with both steady state and transient dc bias, a unified flux balancing control (UFBC) is proposed introducing a predictive bias suppression (PBS) method with closed-loop flux balancing control (CFBC). With the proposed PBS, both primary/secondary current balance and flux balance can be achieved within one switching cycle using UFBC. Power characteristics and interaction between power control and flux balancing control of DAB converters are analyzed, and the CFBC needs to work in a low bandwidth due to sensor bandwidth limitation and interaction between power control and flux balancing control. Lastly, the UFBC is verified on a 300-kW cascaded DAB converter prototype.

42 ENGINEERING↗

A Stable and Ultrafast Control for Multiparallel Grid-Tied SiC Inverters With LVRT Capability Considering Cable Impedance

The stability of multiparalleled grid-tied inverters remains a challenging issue especially during low-voltage ride-through (LVRT) in the presence of grid impedance. SiC device-based grid-tied inverters can achieve advantages such as higher efficiency, reduced size of interface filters, and fast dynamics; however, they can exacerbate this stability issue particularly when LVRT occurs along with high inrush current due to their low inertia characteristics. In this article, a direct deadbeat control method without any PI control loop is proposed for multiparallel grid-tied SiC inverters. The proposed control achieves instantaneous current regulations within switching cycles. In addition, it mitigates high inrush currents and maintains stability during LVRT transients without requiring mode transitions between normal and LVRT operation modes, thereby achieving an ultrafast response and seamless operation through this unified control method. The Lyapunov method is applied to analyze the multiparallel inverter stability in the presence of grid impedance with proposed deadbeat control method. The inverter V-I trajectories during LVRT transients are derived to illustrate the ultrafast and stable feature of proposed control. Finally, the experimental results of two grid-tied SiC inverters operating at LVRT transients are provided to verify the advantages of the proposed control method.

14 SOLAR ENERGY↗

Influence of Control and Limiter Schemes on Sequence-Domain Fault Models of Grid-Forming Inverter-Interfaced Distributed Generators

Unlike synchronous generators, the fault response of grid-forming (GFM) inverter-interfaced distributed generators (IIDGs) is notably governed by the selection of control and current limiting strategies rather than inherent physical traits. While recent research has focused on the sequence domain fault model of GFM IIDGs, a research gap exists in elucidating the influence of control and current limiting schemes on this model's characteristics. This article aims to fill this void by examining how different control and current limiting schemes influence the positive and negative sequence impedances in the phasor-domain fault model of GFM IIDGs. This investigation encompasses droop-based, virtual synchronous machine-based, and virtual oscillator-based reference generation controls alongside rotating and stationary reference-frame-based voltage controls. Furthermore, saturation-based, latching-based, circular and virtual impedance-based current limiting schemes are analyzed. To achieve this goal, a thorough numerical simulation study is conducted. Findings indicate that outer reference generation controls exhibit minimal impact. Conversely, the choice of voltage control and various current limiting schemes emerge as the predominant factors shaping the sequence models of GFM IIDGs. These analyses and results are instrumental in devising reliable protection strategies within inverter-based grids, as a comprehensive understanding of electrical elements in the sequence domain is imperative for effective protective measures.

current limiters↗

WAMS-Based HVDC Damping Control for Cyber Attack Defense

Owing to the fast and large power regulating the capacity of the HVDC system, the wide-area measurement system (WAMS) based high voltage direct current (HVDC) system has been regarded as a prospective solution to deal with the low-frequency oscillation issue. However, due to the vulnerability of the WAMS communication, WAMS based HVDC system control can be a prime target of malicious penetrations that could lead to disastrous events. To remediate this adverse effect, an improved WAMS based HVDC damping control framework is proposed in this paper. First, a lightweight network named Attack Shuffle convolutional neural Networks (ASNet) is proposed to learn the characteristics of cyber attacks. Then, a model-free-based cyber attack defense framework is introduced to quickly identify the attack types based on the continuous wavelet transform and ASNet. Additionally, an improved control framework of the WAMS and HVDC-based wide-area power oscillation damping control (WH-PODC) is developed to provide different response control for mitigation of the impact of cyber attacks. Finally, the performance of the proposed WH-PODC control framework is evaluated with real PMU data in multiple scenarios in RTDS, where the results indicate that the response intensity can be kept under multiple types of cyber attacks while providing similar effectiveness in oscillation suppression to conventional controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Anomaly Detection and Mitigation for Wide-Area Damping Control using Machine Learning

In an interconnected multi-area power system, wide-area measurement based damping controllers are used to damp out inter-area oscillations, which jeopardize grid stability and constrain the power flows below to their transmission capacity. The effect of wide-area damping control (WADC) significantly depends on both power and cyber systems. At the cyber system layer, an adversary can inflict the WADC process by compromising either measurement signals, control signals or both. Stealthy and coordinated cyber-attacks may bypass the conventional cybersecurity measures to disrupt the seamless operation of WADC. This paper proposes an anomaly detection (AD) algorithm using supervised Machine Learning and a model-based logic for mitigation. The proposed AD algorithm considers measurement signals (input of WADC) and control signals (output of WADC) as input to evaluate the type of activity such as normal, perturbation (small or large signal faults), attack and perturbation-and-attack. Upon anomaly detection, the mitigation module tunes the WADC signal and sets the control status mode as either wide-area mode or local mode. The proposed anomaly detection and mitigation (ADM) module works inline with the WADC at the control center for attack detection on both measurement and control signals and eliminates the need for ADMs at the geographically distributed actuators. Here, we consider coordinated and primitive data-integrity attack vectors such as pulse, ramp, relay-trip and replay attacks. The performance of the proposed ADM algorithms was evaluated under these attack vector scenarios on a testbed environment for 2-area 4-machine power system. The ADM module shows effective performance with 96:5% accuracy to detect anomalies.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗