Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CaSe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Highlights of Two Case Studies Illustrate the Diverse Renewable Energy Opportunities for Colorado Agriculture

This presentation highlights the findings from two renewable energy case studies conducted by the Joint Institute for Strategic Energy Analysis (JISEA) for the Colorado Department of Agriculture and the Colorado Energy Office in 2021. The case studies; one exploring renewable energy integration for greenhouses and one evaluating biogas production potential for a dairy, illustrate the wide variety of renewable energy opportunities and the significant potential benefits of renewable energy in the agriculture sector in Colorado.

agriculture↗

NREL On-Demand Transit Research and Fort Erie Case Study

On-demand systems have increased in popularity in recent years, especially in rural and smaller-sized communities. This presentation provides a brief introduction to NREL's on-demand mobility research and an in-depth case study of the town of Fort Erie, Ontario. Fort Erie is a relatively sparsely populated region of 32,901 residents, spread across a land area of 166 square kilometers (64 square miles), for an average population density of 193 residents per square kilometer (500 per square mile). In October 2021, the town implemented a mobility-on-demand system integrated with smartphone software to replace its fixed-route community bus system, which consisted of four buses with three routes, each with a roughly 1-hour, one-way loop. The new service utilizes a fleet of six minivans, two of which are retrofitted with wheelchair-accessible ramps. The system may require that a passenger requesting a standard van walk up to 400 meters (a quarter mile) to their pickup location to optimize vehicle routing while providing origin-to-destination service. The on-demand system proved effective in providing service, eclipsing pre-pandemic ridership by 40%, decreasing greenhouse gas emissions per ride by 63%, and decreasing the cost to the town per ride by 29%. This presentation documents both the previous system and the new system in terms of routes, ridership, costs, fuel, and other notable system parameters. This work is part of an ongoing series of case studies on providing small communities with on-demand, right-sized vehicle service coupled with a smartphone application.

emerging technology↗

Initial PIP-II Beam Current Monitor Fault Case Analyses & Beam Position Monitor Linearity Studies in CST Studio Suite

The use of non-invasive sensors & systems to measure particle beam characteristics is a crucial part of modern accelerator control systems due to their ability to return real time beam data while minimizing negative effects on beam quality. To ensure that one can be reasonably confident these sensors will behave as desired upon be-ing implemented within the beamline, simulations pre-dicting the performance of these sensors under beamline conditions can be used as a valuable tool for checking sensor functionality without a physical test bench. This paper details the design, testing, and results of two sensor models developed using CST Studio Suite soft-ware designed to mimic two sensors to be implemented within the PIP-III beamline: an elliptical, large-aperture beam position monitor (BPM) for which vertical & hori-zontal position signal linearity was analyzed, and an AC current transformer (ACCT) beam current monitor (BCM) used to search for potential fault cases within the BCM and beam pipe flange gaps. Special focus is given to the discovery of linearity variations within the BPM and the use of frequency domain techniques in the BCM fault case analyses.

Rouzky, A. R.↗

GSA Oklahoma City Federal Building: Smart Buildings Case Study

The purpose of this smart buildings case study is to showcase a leading example of a GEB renovation project in the federal buildings space and provide key information on the project roles, processes, costs, and benefits. The findings from this successful GEB project can be used to help pave the way for additional GEB-ready retrofits in the future. The General Services Administration’s (GSA’s) Oklahoma City (OKC) Federal Building, located in downtown Oklahoma City, Oklahoma, demonstrates that GEB-ready strategies and technologies can be realistically deployed today across buildings with minimal investment. The project team implemented nine energy conservation measures (ECMs) and/or smart building technologies, making it a leading example of a smart, sustainable, and efficient commercial building. The case study highlights the challenges and the lessons learned throughout the project design and execution in addition to some of the best practices and considerations when implementing GEB technologies.

Butrico, Mark↗

The HTR-Proteus Benchmark: Analysis and Use as a Verification and Validation Case

This presentation outlines the evaluation and application of the HTR-Proteus benchmark as a verification and validation (V&V) case for advanced reactor modeling tools. The work supports the U.S. Department of Energy’s HALEU Availability Program (HAP) and the joint DOE/NRC DNCSH project, which aims to reduce criticality safety uncertainties in commercial-scale HALEU fuel cycle and transportation systems. The HTR-Proteus experiments, conducted at the Paul Scherrer Institute, provide high-fidelity data for TRISO-fueled, graphite-moderated pebble bed reactors with high neutron leakage—conditions relevant to HALEU transport scenarios. This study focuses on Cores 4.2 and 4.3 of the HTR-Proteus benchmark, analyzing key sources of uncertainty including pebble packing, TRISO particle positioning, and core height. Using Project Chrono for realistic pebble geometries and Serpent, SHIFT, and MCNP for neutronics simulations, the study quantifies the impact of these uncertainties on the effective multiplication factor (keff). Results show that a sample size of 110 pebble configurations is sufficient to converge keff, with ±30 pcm uncertainty due to packing randomness. TRISO positioning and core height variations also significantly influence keff, highlighting the importance of detailed modeling in V&V efforts. The benchmark serves as a valuable test case for validating the Griffin reactor physics code and improving confidence in HALEU system simulations.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling and Energy Analysis of Refrigeration Systems in Supermarkets: A Case Study

Refrigeration systems are the single largest consumer of electricity in supermarkets, accounting for approximately 40–60% of total store electricity use. As supermarkets face increasing pressures to improve efficiency and reduce operational costs, understanding the energy performance of refrigeration systems in supermarkets has become essential. In this paper, we investigate the energy performance and patterns of the refrigeration system using field measurements in one supermarket. The compressor coefficient of performance (COP) averaged 4.5 during nighttime steady-state operation, providing a practical efficiency benchmark. We develop simple physical-based load models for the display cases in the supermarket, where the refrigeration system uses R404A. The results show the display case models achieve a good agreement with measured data, validating its utility for energy estimation during unoccupied hours. Finally, the analysis reveals several challenges of data collection systems for refrigeration systems in the supermarket industry as well.

Chen, Yimin [ORNL] (ORCID:0000000338181655)↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Modelica-based modeling and simulation of district cooling systems: A case study

While equation-based object-oriented modeling language Modelica can evaluate practical energy improvements for district cooling systems, few have adopted Modelica for this type of large-scale thermo-fluid system. Further, to our best knowledge, district cooling modeling studies have yet to include hydraulics in piping networks alongside plant models featuring realistic mechanical systems and controls. These are critical details to include when looking to make energy and control improvements in many physical system installations. To fill these gaps, this study released new open-source district cooling models at the Modelica Buildings Library and leveraged these models for a real-world case study at the University of Colorado Boulder. Here, the site includes six buildings connected to a central chiller plant featuring a waterside economizer. Several energy saving strategies are pursued based on the validated model, including control setpoint optimization, equipment modification, and pump setpoint adjustments. Results indicate that a combination of the studied measures can save the campus annually 84.6 MWh of energy, 8.9% of electricity costs, 58.0 metric tons of carbon dioxide emissions, while the waterside economizer cuts down chillers’ run times by 201 days/year, reducing maintenance costs and extending chiller life.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overarching Properties as Means of Compliance: An Industrial Case Study

The Overarching Properties (OPs) have been created by an inter-national working group and are being evaluated by the National Aeronautics and Space Administration (NASA), the Federal Aviation Administration (FAA), industry, and other certifying agencies in an effort to streamline certification processes. Their intent is to facilitate the use of alternative approaches and to al-low flexibility to combine the system, software, and complex hardware certification. The hope is that the FAA may eventually establish an Advisory Circular that offers the OPs as a Means of Compliance (MoC) for software approval (and eventually systems and hardware) by showing the product possesses the three OPs: Intent (specification of the intended behavior), Correctness (implementation of the intended behavior) and Innocuity (safety of unintended behavior). In the certification community, there is still a concern about the practicability of using such high level properties in certification. This paper aims to address that concern by showing possession of the OPs in an industrial case study using assurance arguments. The two main contributions of this paper are: a certification process based on OPs as Means of Compliance, and a certification argument for an on-board physical model of an UAV, as industrial example. We pro-pose a hybrid approach for the certification process that combines OPs with existing certification standards. Thus, OPs can be used for parts of a system that uses technologies that are not supported by current standards or for which existing standards require additional effort without commensurate additional safety assurance.

certification↗

Students authoring molecular case studies as a partial course-based undergraduate research experience (CURE) for lab instruction

Understanding the relationship between protein structure and function is a core-learning goal in biochemistry. Students often struggle to visualize proteins as three-dimensional objects that interact with other molecules to affect its biochemical consequences. We describe here a partial course-based undergraduate research experiences that has students exploring protein structure and function hands-on while authoring a molecular case study intended for others to use.

59 BASIC BIOLOGICAL SCIENCES↗

A Verification Suite of Test Cases for the Barotropic Solver of Ocean Models

Abstract The development of any atmosphere or ocean model warrants a suite of test cases (TCs) to verify its spatial and temporal discretizations, order of accuracy, stability, reproducibility, portability, scalability, etc. In this paper, we present a suite of shallow water TCs designed to verify the barotropic solver of atmosphere and ocean models. These include the non‐dispersive coastal Kelvin wave; the dispersive inertia‐gravity wave; the dispersive planetary and topographic Rossby waves; the barotropic tide; and a non‐linear manufactured solution. These TCs check the implementation of the linear pressure gradient term; the linear constant or variable‐coefficient Coriolis and bathymetry terms; and the non‐linear advection terms. Simulation results are presented for a variety of time‐stepping methods as well as two spatial discretizations: a mimetic finite volume method based on the TRiSK scheme, and a high‐order discontinuous Galerkin spectral element method. The experimental procedure for conducting these numerical experiments is detailed. It underscores several key considerations that vary depending on the chosen spatial discretization method. Finally, convergence studies of every TC are conducted with refinement in both space and time, only in space, and only in time. The convergence slopes match the expected theoretical predictions.

54 ENVIRONMENTAL SCIENCES↗

5G Communications in Nuclear: Potential Use Cases and Security Considerations

As fifth-generation (5G) communications continues to revolutionize the future of wireless technology, there is growing demand to utilize its benefits for critical infrastructures such as nuclear power plants (NPPs). In regard to achieving full automation and control in the operation of existing and future nuclear reactors, the unique capabilities of 5G can bring several potential advantages over other wireless technologies. However, a deep investigation is needed for the availability and security of 5G communications under various NPP operational scenarios. This article examines how 5G security capabilities can be architecturally deployed in nuclear applications so as to replace existing communication infrastructures. We discuss the current use of all wireless technologies in NPPs with their key features. Consequently, we investigated several NPP use cases in which 5G offers potential advantages but entails specific security considerations. The present article covers the characteristics of 5G communications, general challenges to its application in nuclear, and the security gaps that need to be addressed. We also highlight certain 5G security-by-design features that can help addressing current stringent NPP requirements. In addition, we discuss some future research direction that can facilitate the implementation of 5G in a nuclear facility. The findings presented herein can help foster 5G deployment in NPPs, thus enabling secured data transmission, cost savings, and increased operational efficiency with enhanced reliability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An On-Demand Electric Transit Case Study of New Rochelle, New York

Here, this article characterizes the performance and ridership patterns of an on-demand transit (ODT) service utilizing lightweight electric vehicles (EVs) in New Rochelle, New York. Ridership sociodemographics, travel patterns (both temporal and spatiotemporal), and energy use from the service were explored using travel and survey data from September 2019 through December 2023. The ODT service was found to be used more by women (nearly 60%) and younger demographics (>65% under the age of 42), with peak use in the middle of the day and a grocery store as a top origin and destination. The service was utilized primarily for short trips (86% under 2 mi), with approximately one-third of riders using the ODT service to connect to a train or bus. The costs associated with fueling/charging were compared for different types of fleet vehicles, and the small, right-sized EVs were found to have annual charging costs that were roughly half of the refueling costs for conventional hybrid vans, and 24 times lower than a fleet of diesel buses. Evaluating the vehicle fleet and mapping current socio-spatial travel demand can inform system performance, guide service area development, and support future planning such as expansion to nearby communities and transit hubs. The findings in this case study suggest that on-demand electric transit may be a significant and growing space for advancing highly valued public mobility services. Public transport interventions that consider right-sized, electric, on-demand vehicles can help improve mobility access and reduce energy use and refueling costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Materials Data on CaSe by Materials Project

CaSe is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Ca2+ is bonded to six equivalent Se2- atoms to form a mixture of edge and corner-sharing CaSe6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Ca–Se bond lengths are 2.98 Å. Se2- is bonded to six equivalent Ca2+ atoms to form a mixture of edge and corner-sharing SeCa6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Materials Data on CaSe by Materials Project

CaSe is Zincblende, Sphalerite structured and crystallizes in the cubic F-43m space group. The structure is three-dimensional. Ca2+ is bonded to four equivalent Se2- atoms to form corner-sharing CaSe4 tetrahedra. All Ca–Se bond lengths are 2.86 Å. Se2- is bonded to four equivalent Ca2+ atoms to form corner-sharing SeCa4 tetrahedra.

36 MATERIALS SCIENCE↗

NEWTS EPA FGD Effluent Case Studies

Case studies of selected streams from the EPA FGD Database. Includes OLI Studio and Geochemist's Workbench example files. Original data from: Nguyen, Dan-Tam, Eastern Research Group. Sep 29, 2015. Analytical Database for the Steam Electric Rulemaking - DCN SE05359. https://www.regulations.gov/document/EPA-HQ-OW-2009-0819-5640

Case Study↗

NEWTS USGS Brackish Water Case Studies

Case studies from the USGS Brackish Water Database. Includes OLI Studio and Geochemist's Workbench files. Original data from: Qi, S.L., and Harris, A.C., 2017, Geochemical Database for the Brackish Groundwater Assessment of the United States: U.S. Geological Survey data release, https://doi.org/10.5066/F72F7KK1.

Brackish Groundwater↗

NEWTS USGS Produced Waters Case Studies

Case studies from the USGS Produced Waters Database. Includes OLI Studio and Geochemist's Workbench files. Original data from: Blondes, M. S., Gans, K. D., Engle, M. A., Kharaka, Y. K., Reidy, M. E., Saraswathula, V., Thordsen, J. J., Rowan, E. L., & Morrissey, E. A. (2019). U.S. Geological Survey National Produced Waters Geochemical Database v2.3 [Data set]. U.S. Geological Survey. https://doi.org/10.5066/F7J964W8

Case Studies↗