Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CURRENT AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Optoelectronic Infrastructure for Radio Frequency and Optical Phased Arrays

Optoelectronic integrated circuits offer radiation-hardened solutions for satellite systems in addition to improved size, weight, power, and bandwidth characteristics. ODIS, Inc., has developed optoelectronic integrated circuit technology for sensing and data transfer in phased arrays. The technology applies integrated components (lasers, amplifiers, modulators, detectors, and optical waveguide switches) to a radio frequency (RF) array with true time delay for beamsteering. Optical beamsteering is achieved by controlling the current in a two-dimensional (2D) array. In this project, ODIS integrated key components to produce common RF-optical aperture operation.

Cai, Jianhong↗

High-Voltage Power Supply With Fast Rise and Fall Times

A special-purpose high-voltage power supply can be electronically switched on and off with fast rise and fall times, respectively. The output potential is programmable from 20 to 1,250 V. An output current of 50 A can be sustained at 1,250 V. The power supply was designed specifically for electronically shuttering a microchannel plate in an x-ray detector that must operate with exposure times as short as 1 ms. The basic design of the power supply is also adaptable to other applications in which there are requirements for rapid slewing of high voltages. The power-supply circuitry (see figure) includes a preregulator, which is used to program the output at 1/30 of the desired output potential. After the desired voltage has been set, the outputs of a pulse width modulator (PWM) are enabled and used to amplify the preregulator output potential by 30. The amplification is achieved by use of two voltage doublers with a transformer that has two primary and two secondary windings. A resistor is used to limit the current by controlling the drive voltage of two field-effect transistors (FETs) during turn-on of the PWM. A pulse transformer is used to turn on four FETs to short-circuit four output capacitors when the outputs of the PWM have been disabled. The most notable aspects of the performance of the power supply are a rise time of only 80 s and a fall time of only 60 s at a load current of 50 A or less. Another notable aspect is that the application of a 0-to-5-V square wave to a shutdown pin of the PWM causes the production of a 0-to-1,250-V square wave at the output terminals.

Bearden, Douglas B.↗

Theoretical simulation of carrier capture and relaxation rates in quantum-dot semiconductor optical amplifiers

Based on Auger scattering mechanism, carrier-carrier scattering dynamics between the two-dimensional carrier reservoir (also called wetting layer, i.e., WL) and the confined quantum dot ground and first excited state in quantum-dot semiconductor optical amplifiers (QD-SOAs) are investigated theoretically in this paper. The scattering rates for independent electron and hole densities are calculated. The results show an ultra-fast carrier capture (relaxation) rate up to 1 ps{sup −1}, and there is a complex dependence of the Coulomb scattering rates on the WL electron and hole densities. In addition, due to the different effective mass and the level distribution, the scattering rates for electron and hole are very different. Finally, in order to provide a direction to control (increase or decrease) the input current in realistic QD-SOA systems, a simple method is proposed to determine the trends of the carrier recovery rates with the WL carrier densities in the vicinity of the steady-state.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relative contributions of mean-state shifts and ENSO-driven variability to precipitation changes in a warming climate

The El Niño–Southern Oscillation (ENSO) is an important driver of regional hydroclimate variability through far-reaching teleconnections. This study uses simulations performed with coupled general circulation models (CGCMs) to investigate how regional precipitation in the twenty-first century may be affected by changes in both ENSO-driven precipitation variability and slowly evolving mean rainfall. First, a dominant, time-invariant pattern of canonical ENSO variability (cENSO) is identified in observed SST data. Next, the fidelity with which 33 state-of-the-art CGCMs represent the spatial structure and temporal variability of this pattern (as well as its associated precipitation responses) is evaluated in simulations of twentieth-century climate change. Possible changes in both the temporal variability of this pattern and its associated precipitation teleconnections are investigated in twenty-first-century climate projections. Models with better representation of the observed structure of the cENSO pattern produce winter rainfall teleconnection patterns that are in better accord with twentieth-century observations and more stationary during the twenty-first century. Finally, the model-predicted twenty-first-century rainfall response to cENSO is decomposed into the sum of three terms: 1) the twenty-first-century change in the mean state of precipitation, 2) the historical precipitation response to the cENSO pattern, and 3) a future enhancement in the rainfall response to cENSO, which amplifies rainfall extremes. Lastly, by examining the three terms jointly, this conceptual framework allows the identification of regions likely to experience future rainfall anomalies that are without precedent in the current climate.

54 ENVIRONMENTAL SCIENCES↗

The link between shocks, turbulence, and magnetic reconnection in collisionless plasmas

Global hybrid (electron fluid, kinetic ions) and fully kinetic simulations of the magnetosphere have been used to show surprising interconnection between shocks, turbulence, and magnetic reconnection. In particular, collisionless shocks with their reflected ions that can get upstream before retransmission can generate previously unforeseen phenomena in the post shocked flows: (i) formation of reconnecting current sheets and magnetic islands with sizes up to tens of ion inertial length. (ii) Generation of large scale low frequency electromagnetic waves that are compressed and amplified as they cross the shock. These “wavefronts” maintain their integrity for tens of ion cyclotron times but eventually disrupt and dissipate their energy. (iii) Rippling of the shock front, which can in turn lead to formation of fast collimated jets extending to hundreds of ion inertial lengths downstream of the shock. The jets, which have high dynamical pressure, “stir” the downstream region, creating large scale disturbances such as vortices, sunward flows, and can trigger flux ropes along the magnetopause. This phenomenology closes the loop between shocks, turbulence, and magnetic reconnection in ways previously unrealized. These interconnections appear generic for the collisionless plasmas typical of space and are expected even at planar shocks, although they will also occur at curved shocks as occur at planets or around ejecta.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A strained silicon cold electron bolometer using Schottky contacts

We describe optical characterisation of a strained silicon cold electron bolometer (CEB), operating on a 350 mK stage, designed for absorption of millimetre-wave radiation. The silicon cold electron bolometer utilises Schottky contacts between a superconductor and an n{sup ++} doped silicon island to detect changes in the temperature of the charge carriers in the silicon, due to variations in absorbed radiation. By using strained silicon as the absorber, we decrease the electron-phonon coupling in the device and increase the responsivity to incoming power. The strained silicon absorber is coupled to a planar aluminium twin-slot antenna designed to couple to 160 GHz and that serves as the superconducting contacts. From the measured optical responsivity and spectral response, we calculate a maximum optical efficiency of 50% for radiation coupled into the device by the planar antenna and an overall noise equivalent power, referred to absorbed optical power, of 1.1×10{sup −16} W Hz{sup −1/2} when the detector is observing a 300 K source through a 4 K throughput limiting aperture. Even though this optical system is not optimized, we measure a system noise equivalent temperature difference of 6 mK Hz{sup −1/2}. We measure the noise of the device using a cross-correlation of time stream data, measured simultaneously with two junction field-effect transistor amplifiers, with a base correlated noise level of 300 pV Hz{sup −1/2} and find that the total noise is consistent with a combination of photon noise, current shot noise, and electron-phonon thermal noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat transport in active harmonic chains

We show that a harmonic lattice model with amplifying and attenuating elements, when coupled to two thermal baths, exhibits unique heat transport properties. Some of these novel features include anomalous nonequilibrium steady-state heat currents, negative differential thermal conductance, as well as nonreciprocal heat transport. We find that when these elements are arranged in a PT-symmetric manner, the domain of existence of the nonequilibrium steady state is maximized. We propose an electronic experimental setup based on resistive-inductive-capacitive (RLC) transmission lines, where our predictions can be tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-AB-BRB-03: Investigation of a Small Photomultiplier-Based Probe for Use in Beam Diagnostics and Medical Dosimetry

Purpose: Investigate the use of a small photomultiplier-based probe as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams was detected by a small photomultiplier tube (PMT). Measurements of Clinac beams were made both in air and by inserting the PMT directly into a water phantom. A conical collimator placed in front of the PMT reduced the angular acceptance and the detection of scattered light. With this arrangement, we obtained response curves as a function of depth along the central axis similar in shape and magnitude to those obtained with ionization chambers. Subsequent measurements were made with the PMT covered in aluminum foil, obtaining a signal arising primarily from direct Cerenkov light produced in the glass entrance window. With an oscilloscope and amplifier/MCA system, we were able to monitor the response to individual beam pulses and observe variations in the beam pulse shape and magnitude as a function of dose rate. Results: Using Cerenkov signals detected by a PMT, we were able to obtain reasonable beam quality metrics, and the response was found to be linear over a range of dose rates. The fast response of the PMT allowed for the observation of small changes in the shape and magnitude of the beam pulse. With this system we were able to detect small changes in the dose per pulse delivered by the accelerator. Conclusion: A small PMT probe has shown promise as a beam diagnostic and medical dosimetry tool. Its fast response allows for real time beam pulse monitoring, and the integrated response can yield relative and perhaps even absolute dose information with a properly calibrated system. For accelerator diagnostics, monitoring of the beam pulse shape can aid in beam tuning, particularly in electron mode, where no target current pulse is available.

60 APPLIED LIFE SCIENCES↗

Automatic gain control

An automatic gain control (AGC), designed to operate with the prototype Loran-C receiver, is described. The device is used to eliminate error which occurs when signals are received at different magnitudes. The automatic gain control is a three transistor circuit which requires a constant dc voltage of 8 volts. Tests conclude that this value may be in the range of 4 to 12 v without change in circuit performance. Two transistors are cascaded to pass and amplify the input signal. Their gain is controlled by a third transistor which itself is controlled by an external AGC voltage between 0 and 8 volts dc. The integrated circuit used is an 8 pin chip, which is a differential cascade amplifier designed for use in communications operating at frequencies from dc to 120 MHz. The integrated circuit was balanced for AGC capabilities, and has a wide operating current range. The maximum input current at pins 1 and 5 is 0.1 mAmps. AGC testing is described.

Roman, J. P.↗

The Link Between Shocks, Turbulence, and Magnetic Reconnection in Collisionless Plasmas

Global hybrid (electron fluid, kinetic ions) and fully kinetic simulations of the magnetosphere have been used to show surprising interconnection between shocks, turbulence and magnetic reconnection. In particular collisionless shocks with their reflected ions that can get upstream before retransmission can generate previously unforeseen phenomena in the post shocked flows: (i) formation of reconnecting current sheets and magnetic islands with sizes up to tens of ion inertial length. (ii) Generation of large scale low frequency electromagnetic waves that are compressed and amplified as they cross the shock. These 'wavefronts' maintain their integrity for tens of ion cyclotron times but eventually disrupt and dissipate their energy. (iii) Rippling of the shock front, which can in turn lead to formation of fast collimated jets extending to hundreds of ion inertial lengths downstream of the shock. The jets, which have high dynamical pressure, 'stir' the downstream region, creating large scale disturbances such as vortices, sunward flows, and can trigger flux ropes along the magnetopause. This phenomenology closes the loop between shocks, turbulence and magnetic reconnection in ways previously unrealized. These interconnections appear generic for the collisionless plasmas typical of space, and are expected even at planar shocks, although they will also occur at curved shocks as occur at planets or around ejecta.

MAGNETOSPHERE↗

Free-electron laser driven by the LBNL laser-plasma accelerator

A design of a compact free-electron laser (FEL), generating ultra-fast, high-peak flux, XUV pulses is presented. The FEL is driven by ahigh-current, 0.5 GeV electron beam from the Lawrence Berkeley National Laboratory (LBNL) laser-plasma accelerator, whose active acceleration length is only a few centimeters. The proposed ultra-fast source (~;;10 fs) would be intrinsically temporally synchronized to the drive laser pulse, enabling pump-probe studies in ultra-fast science. Owing to the high current (>10 kA) of the laser-plasma-accelerated electron beams, saturated output fluxes are potentially greater than 10^13 photons/pulse. Devices based both on self-amplified spontaneous emission and high-harmonic generated input seeds, to reduce undulator length and fluctuations, are considered.

43 PARTICLE ACCELERATORS↗

White noise of Nb-based microwave superconducting quantum interference device multiplexers with NbN coplanar resonators for readout of transition edge sensors

White noise of dissipationless microwave radio frequency superconducting quantum interference device (RF-SQUID) multiplexers has been experimentally studied to evaluate their readout performance for transition edge sensor (TES) photon counters ranging from near infrared to gamma ray. The characterization has been carried out at 4 K, first to avoid the low-frequency fluctuations present at around 0.1 K, and second, for a feasibility study of readout operation at 4 K for extended applications. To increase the resonant Q at 4 K and maintain low noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1 × 10{sup 4} ≤ Q ≤ 2 × 10{sup 4} and the square root of spectral density of current noise referred to the SQUID input √S{sub I} = 31 pA/√Hz. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Two-directional readout on the complex plane of the transmission component of scattering matrix S{sub 21} enables us to distinguish the flux noise from noise originating from other sources, such as the cryogenic high electron mobility transistor (HEMT) amplifier. Systematic noise measurements with various microwave readout powers P{sub MR} make it possible to distinguish the contribution of noise sources within the system as follows: (1) The achieved √S{sub I} is dominated by the Nyquist noise from a resistor at 4 K in parallel to the SQUID input coil which is present to prevent microwave leakage to the TES. (2) The next dominant source is either the HEMT-amplifier noise (for small values of P{sub MR}) or the quantization noise due to the resolution of 300-K electronics (for large values of P{sub MR}). By a decrease of these noise levels to a degree that is achievable by current technology, we predict that the microwave RF-SQUID multiplexer can exhibit √S{sub I} ≤ 5 pA/√Hz, i.e., close to √S{sub I} of state-of-the-art DC-SQUID-based multiplexers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thin-Film Air-Mass-Flow Sensor of Improved Design Developed

Researchers at the NASA Glenn Research Center have developed a new air-mass-flow sensor to solve the problems of existing mass flow sensor designs. NASA's design consists of thin-film resistors in a Wheatstone bridge arrangement. The resistors are fabricated on a thin, constant-thickness airfoil to minimize disturbance to the airflow being measured. The following photograph shows one of NASA s prototype sensors. In comparison to other air-mass-flow sensor designs, NASA s thin-film sensor is much more robust than hot wires, causes less airflow disturbance than pitot tubes, is more accurate than vane anemometers, and is much simpler to operate than thermocouple rakes. NASA s thin-film air-mass-flow sensor works by converting the temperature difference seen at each leg of the thin-film Wheatstone bridge into a mass-flow rate. The following figure shows a schematic of this sensor with air flowing around it. The sensor operates as follows: current is applied to the bridge, which increases its temperature. If there is no flow, all the arms are heated equally, the bridge remains in balance, and there is no signal. If there is flow, the air passing over the upstream legs of the bridge reduces the temperature of the upstream legs and that leads to reduced electrical resistance for those legs. After the air has picked up heat from the upstream legs, it continues and passes over the downstream legs of the bridge. The heated air raises the temperature of these legs, increasing their electrical resistance. The resistance difference between the upstream and downstream legs unbalances the bridge, causing a voltage difference that can be amplified and calibrated to the airflow rate. Separate sensors mounted on the airfoil measure the temperature of the airflow, which is used to complete the calculation for the mass of air passing by the sensor. A current application for air-mass-flow sensors is as part of the intake system for an internal combustion engine. A mass-flow sensor is used to provide accurate information about the amount of air entering the engine so that the amount of fuel can be adjusted to give the most efficient combustion. The ideal mass-flow sensor would be a rugged design that minimizes the disturbance to the flow stream and provides an accurate reading of both smooth and turbulent flows; NASA's design satisfies these requirements better than any existing design. Most of the mass-flow sensors used today are the hot wire variety. Hot wires can be fragile and cannot accurately measure a turbulent or reversing flow, which is often encountered in an intake manifold. Other types of mass-flow sensors include pitot tubes, vane anemometers, and thermocouple rakes-all of which suffer from some type of performance problem. Because it solves these performance problems while maintaining a simple design that lends itself to low-cost manufacturing techniques, NASA s thin-film resistance temperature detector air-mass-flow sensor should lead to more widespread use of mass-flow sensors.

Fralick, Gustave C.↗

A 3D-Printed Microresonator Based on the Quartz-Enhanced Photoacoustic Spectroscopy Sensor for Methane Detection

A 3D-printed microresonator based on a quartz tuning fork has been developed. The sensor performance is evaluated by detection of methane with a fiber-coupled distributed feedback diode laser. In combination with wavelength modulation spectroscopy, a minimum detectable concentration of 15.6 ppb by volume is achieved at atmospheric pressure with an 8-mW average optical excitation power and a lock-in amplifier time constant of 1 s, which corresponds to a 1σ normalized noise equivalent absorption coefficient of 5·10{sup –9} cm{sup –1}·W/Hz{sup 1/2}. An Allan variance analysis shows that the system has long-term stability and can serve as the basis for a portable gas analyzer. Approaches to improve the current sensor performance are also discussed. This design greatly reduces the time of manufacturing the microresonator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Apoferritin Protein Nanoparticles Dually labeled with Aptamer and Horseradish Peroxidase as a Sensing Probe for Thrombin Detection

A sandwich-type electrochemical aptasensor has been developed for the detection of thrombin, based on dual signal-amplification using HRP and apoferritin. Aptamer1 (Apt1) loaded on core/shell Fe3O4/Au magnetic nanoparticle (AuMNP) was used as recognition elements, and apoferritin dually labeled with Aptamer2 (Apt2) and HRP was used as a detection probe. Sandwich-type complex, Apt1/thrombin/Apt2–apoferritin NPs–HRP was formed by the affinity reactions between AuMNPs–Apt1, thrombin, and Apt2–apoferritin–HRP. The complex was anchored on a screen-printed carbon electrode (SPCE). Differential pulse voltammetry (DPV) was used to monitor the electrode response. The proposed aptasensor yielded a linear current response to thrombin concentrations over a broad range of 0.5 pM to 100 pM with a detection limit of 0.07 pM (S/N = 3). The detection signal was amplified by using apoferritin and HRP. This nanoparticle-based aptasensor offers a new method for rapid, sensitive, selective, and inexpensive quantification of thrombin, and offers a promising potential in biomarker detection and disease diagnosis. --------------------------------------------------------------------------------

aptmer↗

Activities on Realization of High-Power and Steady-State ECRH System and Achievement of High Performance Plasmas in LHD

Electron Cyclotron Resonance Heating (ECRH) has contributed to the achievement of high performance plasma production, high electron temperature plasmas and sustainment of steady-state plasmas in the Large Helical Device (LHD). Our immediate targets of upgrading the ECRH system are 5 MW several seconds and 1 MW longer than one hour power injection into LHD. The improvement will greatly extend the plasma parameter regime. For that purpose, we have been promoting the development and installation of 77 GHz/1-1.5 MW/several seconds and 0.3 MW/CW gyrotrons in collaboration with University of Tsukuba. The transmission lines are re-examined and improved for high and CW power transmission. In the recent experimental campaign, two 77 GHz gyrotrons were operated. One more gyrotron, which was designed for 1.5 MW/2 s output, was constructed and is tested. We have been promoting to improve total ECRH efficiency for efficient gyrotron-power use and efficient plasma heating, e.g. a new waveguide alignment method and mode-content analysis and the feedback control of the injection polarization. In the last experimental campaign, the 77 GHz gyrotrons were used in combination with the existing 84 GHz range and 168 GHz gyrotrons. Multi-frequency ECRH system is more flexible in plasma heating experiments and diagnostics. A lot of experiments have been performed in relation to high electron temperature plasmas by realization of the core electron-root confinement (CERC), electron cyclotron current drive (ECCD), Electron Bernstein Wave heating, and steady-state plasma sustainment. Some of the experimental results are briefly described.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Texas petawatt laser and current experiments

The Texas Petawatt Laser is operational with experimental campaigns executed in both F/40 and F3 target chambers. Recent improvements have resulted in intensities of >2 Multiplication-Sign 10{sup 21} W/cm{sup 2} on target. Experimental highlights include, accelerated electron energies of >2 GeV, DD fusion ion temperatures >25 keV and isochorically heated solids to 10-50 eV.

43 PARTICLE ACCELERATORS↗