Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMPACTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Modified magnetic field distribution in relativistic magnetron with diffraction output for compact operation

A modified magnetic field distribution in relativistic magnetron with diffraction output (MDO) for compact operation is proposed in this paper. The principle of how the modified magnetic field confines electrons drifting out of the interaction space is analyzed. The results of the particle-in-cell (PIC) simulations of the MDO with the modified magnetic field distribution show that the output power of the MDO is improved, and the long cylindrical waveguide used for collecting the drifting electrons can be omitted. The latter measure allows the horn antenna of the MDO to produce more focused energy with better directivity in the far field than it does with the long cylindrical waveguide. The MDO with the modified magnetic field distribution promises to be the real most compact narrow band high power microwave source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact post-acceleration scheme for laser-generated protons

Protons generated by irradiating a thin metal foil with a high-intensitylaser have shown to posses interesting characteristics in terms of energy, emittance, current, and pulse duration. Therefore, in the near future, they might become a competitive source with respect to conventional proton sources. Previous theoretical, numerical, and experimental studies have already demonstrated efficient coupling between laser-accelerated proton beams with traditional radio frequency (RF)-based particle accelerators. These hybrid proton accelerators benefit from both the excellent properties of the laser-based source and the flexibility, reliability, and know-how of beam handling as provided by RF-based accelerator structures. In this paper, state of the art experimental results of laser-accelerated proton beams are used as input for a numerical study using compact and innovative conventional accelerator structures designed for medical applications. Results show that this compact hybrid accelerator allows even more efficient capture and acceleration of the laser-generated proton beam.

43 PARTICLE ACCELERATORS↗

Modeling of early stages of island growth during pulsed deposition: Role of closed compact islands

After a brief review of recent modeling of growth during Pulsed Laser Deposition (PLD), we present the study of a role of adatom interactions on growth of surface islands during PLD in submonolayer regime. We employ kinetic Monte Carlo simulation with reversible growth. Attachment of monomers to islands is irreversible at low temperatures while it becomes reversible at higher temperatures, small islands become unstable with growing temperature. In the case of real system we have to take into account not only diffusion of monomers but also diffusivity of dimers and larger clusters and theirs stability. Our new code allows us to study processes which proceed on different time scales which are typical in PLD experiments: fast deposition (on scale order of 10{sup -5} s) during individual pulses, and relaxation of a system between pulses (on scale order of 0.1 s). We calculate and compare the temperature dependence of island density for two modes pulsed deposition and continuous Molecular Beam Epitaxy (MBE) growth. The island densities in PLD mode are substantially higher than in MBE mode, provided the temperature is sufficiently high. In the case of PLD, we observe anomalous temperature dependence of the island density in a certain temperature interval. It is due to the interplay between a cluster decay time and an interval between pulses. The cluster decay time depends not only on temperature but also on clusters size and shape. The anomalous behavior is caused by the temperature limited stability of the closed--compact clusters. This scenario was revealed for the simplified model with only nearest-neighbor interaction. Now, it is elucidated further and we also include interaction to second and third neighbors. We analyze role of the closed-compact surface island in kinetics of both growth modes. Furthermore, by varying interactions energies, diffusion barrier and parameters of deposition, we compare results of simulations with the PLD experiment for Fe/Mo system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Scintillator Materials for Compact Electron Antineutrino Detectors

Developments in the fields of chemistry and materials science provide new components that hold the potential to improve the performance of liquid scintillation electron antineutrino detectors used for the monitoring of nuclear reactors. New compounds can provide for more efficient, stable, and safer operation of these detectors. Current detectors and their detector materials raise issues regarding size, quantum efficiency, stability, and spatial resolution for the vertex detection. For compact detectors (1 m{sup 3} active volume) improvement of these issues with existing liquid scintillation cocktails can be obtained by means of developing stable and efficient neutron capture agents. These agents comprise of boron or lithium containing coordination compounds, in addition advances in fluorescence detection technologies and optimization of solvent characteristics can improve the overall efficiency. Focus points of the new detector material design are to enable a compact, robust, and direction sensitive electron antineutrino detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact AMS System At Yamagata University

A new compact accelerator mass spectrometry (AMS) system has been installed in the Kaminoyama research institute at Yamagata University. The AMS system is based on a 0.5 MV Pelletron accelerator developed by National Electrostatics Corp. The performance of the system was investigated using C series samples (C1-C8), standard samples (HOxII), and reagent graphite without any chemical treatment. The precision of {sup 14}C measurements for the standard samples is typically higher than 0.3%. The ratio of {sup 14}C to {sup 12}C is less than 6x10{sup -16} for the reagent graphite. In this paper, we present the performance of the new compact AMS system, as well as of the fully automated 20-reactor graphite lines equipped at the research institute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High resolution, large field of view x-ray differential phase contrast imaging on a compact setup

X-ray grating interferometry is a well established technique to perform differential phase contrast imaging on conventional x-ray tubes. So far, the application of this technique in commercial micro computed tomography scanners has remained a major challenge due to the compact setup geometry. In this letter, we report on the design of a compact imaging setup using a microfocus source. Due to the extreme wave front curvature, the gratings are fabricated on a flexible substrate, enabling precise cylindrical shaping. A laboratory setup and a modified SCANCO {mu}CT100 scanner have been built, allowing high resolution and large field of view imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact permanent magnet helicon plasma source for ion beam bioengineering

A compact helicon plasma source was developed as a millimeter-sized ion source for ion beam bioengineering. By employing a stacked arrangement of annular-shaped permanent magnets, a uniform axial magnetic flux density up to 2.8 kG was obtained. A cost effective 118 MHz RF generator was built for adjusting forward output power from 0 to 40 W. The load impedance and matching network were then analyzed. A single loop antenna and circuit matching elements were placed on a compact printed circuit board for 50 {Omega} impedance matching. A plasma density up to 1.1 x 10{sup 12} cm{sup -3} in the 10 mm diameter tube under the magnetic flux density was achieved with 35 W applied RF power.

43 PARTICLE ACCELERATORS↗

A compact P-band coaxial relativistic backward wave oscillator with only three periods slow wave structure

A compact P-band coaxial relativistic backward wave oscillator (BWO) with only three periods slow wave structure (SWS) is investigated both theoretically and numerically. The characteristics of the coaxial SWS are analyzed when the SWS is changed from the structure with only outer conductor ripple to the structure with both inner and outer conductor ripples. It is found that the existence of the inner conductor ripple can reduce the period length of coaxial SWS to maintain the same operating frequency of the BWO and can largely increase the temporal growth rate and the spatial growth rate of the device. Then, the effects of SWS period numbers on the generation of the microwave in the P-band relativistic BWO are studied by PIC simulations. The results show that three periods SWS cannot only make the device more compact but also has a wide region of single-frequency operation and relatively large efficiency and output power in a wide range of the diode voltage. Typical simulation results show that, with a 585 kV and 7.85 kA electron beam guided by a 0.8 T solenoidal field, the microwave of 1.65 GW is generated at the frequency of 900 MHz, and the interaction efficiency is about 36%. Compared with the conventional P-band coaxial relativistic BWO with five periods SWS, the axial length of the SWS is reduced by about one half, which is only 38.4 cm, and the saturation time of the microwave signal is reduced by about 10 ns.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Passive compact molten salt reactor (PCMSR), modular thermal breeder reactor with totally passive safety system

Design Study Passive Compact Molten Salt Reactor (PCMSR) with totally passive safety system has been performed. The term of Compact in the PCMSR name means that the reactor system is designed to have relatively small volume per unit power output by using modular and integral concept. In term of modular, the reactor system consists of three modules, i.e. reactor module, turbine module and fuel management module. The reactor module is an integral design that consists of reactor, primary and intermediate heat exchangers and passive post shutdown cooling system. The turbine module is an integral design of a multi heating, multi cooling, regenerative gas turbine. The fuel management module consists of all equipments related to fuel preparation, fuel reprocessing and radioactive handling. The preliminary calculations show that the PCMSR has negative temperature and void reactivity coefficient, passive shutdown characteristic related to fuel pump failure and possibility of using natural circulation for post shutdown cooling system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A compact high vacuum heating chamber for in-situ x-ray scattering studies

A very compact multi purpose high vacuum heating chamber for x-ray scattering techniques was developed. The compact design allows the chamber to be installed on high precision diffractometers which usually cannot support heavy and/or large equipment. The chamber is covered by a Be dome allowing full access to the hemisphere above the sample which is required for in-plane grazing incident x-ray diffraction and out-off plane wide angle x-ray diffraction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the compact proton beam therapy system dedicated to spot scanning with real-time tumor-tracking technology

Hokkaido University and Hitachi Ltd. have started joint development of the Gated Spot Scanning Proton Therapy with Real-Time Tumor-Tracking System by integrating real-time tumor tracking technology (RTRT) and the proton therapy system dedicated to discrete spot scanning techniques under the {sup F}unding Program for World-Leading Innovative R and D on Science and Technology (FIRST Program){sup .} In this development, we have designed the synchrotron-based accelerator system by using the advantages of the spot scanning technique in order to realize a more compact and lower cost proton therapy system than the conventional system. In the gated irradiation, we have focused on the issues to maximize irradiation efficiency and minimize the dose errors caused by organ motion. In order to understand the interplay effect between scanning beam delivery and target motion, we conducted a simulation study. The newly designed system consists of the synchrotron, beam transport system, one compact rotating gantry treatment room with robotic couch, and one experimental room for future research. To improve the irradiation efficiency, the new control function which enables multiple gated irradiations per synchrotron cycle has been applied and its efficacy was confirmed by the irradiation time estimation. As for the interplay effect, we confirmed that the selection of a strict gating width and scan direction enables formation of the uniform dose distribution.

43 PARTICLE ACCELERATORS↗

Characterization and calibration of compact array spectrometers in the ultraviolet spectral region

Array-based spectrometers, with their compact size, low weight, low cost, and fast measurement time, are now frequently used in place of both conventional single-channel scanning monochromators, and broadband meters. Their rapid measurement capability makes them an attractive option for routine solar UV spectral measurements, where shortterm variability in signal is a challenge. However, compactness, portability, low cost and high speed are achieved at the expense of the spectrometer's optical and electronic performance. Thus such spectrometers are more prone to measurement error from environmental changes, and more prone to other intrinsic sources of error such as stray light and detector non-linearity, which significantly affect solar UV measurements, than a scanning monochromator. The effects of stray light and non-linearity can be reduced either by improved optical and detector design or by a detailed spectrometer characterization. We present in this paper our investigation of the performance of three different commercial array spectrometers: two mini-spectrometers, and a more elaborate array spectrometer with an on-board image amplifier device. These were tested for a subset of performance parameters: their wavelength accuracy and stability, electronic linearity, responsivity linearity, stray light sensitivity, and mechanical stability and repeatability. With all three spectrometers we found that these parameters, particularly but not limited to stray light, had a significant impact on the measurement of the incoming optical radiation. This meant that, without characterization, the instruments would be unable to accurately measure the UV component of any source with significant visible radiation. We discuss various simple and low-cost solutions for improving the performance of these instruments, and providing a rigorous calibration using a straightforward set-up including optical filters and the quasi-monochromatic light from a double monochromator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digitizer based compact digital spectrometer for ion beam analysis using field programmable gate arrays and various energy algorithms

We report on the implementation of a compact multi-detector fully digital spectrometer and data acquisition system at a nuclear microprobe for ion beam analysis and imaging. The spectrometer design allows for system scalability with no restriction on the number of detectors. It consists of four-channel high-speed digitizer modules for detector signal acquisition and one low-speed digital-to-analog converter (DAC) module with two DAC channels and additional general purpose inputs/outputs to control ion beam scanning and data acquisition. Each digitizer module of the spectrometer provides its own Field Programmable Gate Array (FPGA) as digital signal processing unit to analyze detector signals as well as to synchronize the ion beam position in hard real-time. With the customized FPGA designs for all modules, all calculation intensive tasks are executed inside the modules, which reduces significantly the data stream to and CPU load on the control computer. To achieve an optimal energy resolution for all detector/preamplifier pulse shape characteristics, a user-definable infinite impulse response filter with high throughput for energy determination was implemented. The new spectrometer has an online data analysis feature, a compact size, and is able to process any type of detector signals such as particle induced x-ray emission, Rutherford backscattering spectrometry, or scanning transmission ion microscopy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new compact fixed-point blackbody furnace

More and more NMIs are realizing their primary scale themselves with fixed-point blackbodies as their reference standard. However, commercially available fixed-point blackbody furnaces of sufficient quality are not always easy to obtain. CHINO Corp. and NMIJ, AIST jointly developed a new compact fixed-point blackbody furnace. The new furnace has such features as 1) improved temperature uniformity when compared to previous products, enabling better plateau quality, 2) adoption of the hybrid fixed-point cell structure with internal insulation to improve robustness and thereby to extend lifetime, 3) easily ejectable and replaceable heater unit and fixed-point cell design, leading to reduced maintenance cost, 4) interchangeability among multiple fixed points from In to Cu points. The replaceable cell feature facilitates long term maintenance of the scale through management of a group of fixed-point cells of the same type. The compact furnace is easily transportable and therefore can also function as a traveling standard for disseminating the radiation temperature scale, and for maintaining the scale at the secondary level and industrial calibration laboratories. It is expected that the furnace will play a key role of the traveling standard in the anticipated APMP supplementary comparison of the radiation thermometry scale.

42 ENGINEERING↗

Compact low resolution spectrograph, an imaging and long slit spectrograph for robotic telescopes

The COmpact LOw REsolution Spectrograph (COLORES) is a compact and lightweight (13 kg) f/8 imaging spectrograph designed for robotic telescopes, now installed and operating on the TELMA, a rapid-slewing 60 cm telescope of the BOOTES-2 observatory in Málaga (Spain). COLORES is a multi-mode instrument that enables the observer to seamlessly switch between low-dispersion spectroscopy and direct imaging modes during an observation. In this paper, we describe the instrument and its development, from the initial scientific requirements through the optical design process to final configuration with theoretical performance calculations. The mechanical and electronic design is described, methods of calibration are discussed and early laboratory and scientific results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility study for measurement of insulation compaction in the cryogenic rocket fuel storage tanks at Kennedy Space Center by fast/thermal neutron techniques

The liquid hydrogen and oxygen cryogenic storage tanks at John F. Kennedy Space Center (KSC) use expanded perlite as thermal insulation. Some of the perlite may have compacted over time, compromising the thermal performance and also the structural integrity of the tanks. Neutrons can readily penetrate through the 1.75 cm outer steel shell and through the entire 120 cm thick perlite zone. Neutrons interactions with materials produce characteristic gamma rays which are then detected. In compacted perlite the count rates in the individual peaks in the gamma ray spectrum will increase. Portable neutron generators can produce neutron simultaneous fluxes in two energy ranges: fast (14 MeV) and thermal (25 meV). Fast neutrons produce gamma rays by inelastic scattering which is sensitive to Si, Al, Fe and O. Thermal neutrons produce gamma rays by radiative capture in prompt gamma neutron activation (PGNA), which is sensitive to Si, Al, Na, K and H among others. The results of computer simulations using the software MCNP and measurements on a test article suggest that the most promising approach would be to operate the system in time-of-flight mode by pulsing the neutron generator and observing the subsequent die away curve in the PGNA signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of ball milling and dynamic compaction on magnetic properties of Al{sub 2}O{sub 3}/Co(P) composite particles

The evolution of the magnetic properties of composite Al{sub 2}O{sub 3}/Co(P) particles during ball milling and dynamic compaction is investigated. To prepare starting composite particles, the Al{sub 2}O{sub 3} granules were coated with a Co{sub 95}P{sub 5} shell by electroless plating. The magnetic and structural properties of the composite particles are characterized by scanning electron microscopy, X-ray diffraction, and the use of the Physical Property Measurement System. The use of composite core-shell particles as starting powder for mechanoactivation allows to decrease treatment duration to 1 h and to produce a more homogeneous bulk sample than in the case of the mixture of Co and Al{sub 2}O{sub 3} powders. The magnetic properties of the milled composite particles are correlated with changes in the microstructure. Reduction in grain size of Co during milling leads to an increase of the volume fraction of superparamagnetic particles and to a decrease of the saturation magnetization. The local magnetic anisotropy field depends on the amount of hcp-Co phase in sample. The anisotropy field value decreases from 8.4 kOe to 3.8 kOe with an increase in milling duration up to 75 min. The regimes of dynamic compaction were selected so that the magnetic characteristics—saturation magnetization and coercive field—remained unchanged.

36 MATERIALS SCIENCE↗

A super-compact metamaterial absorber cell in L-band

A super-compact metamaterial absorber (SMA) unit cell in L band (1–2 GHz) is proposed, which is composed of a pair of electric ring resonator (ERR) and its complementary ERR (CERR) with a high dielectric substrate sandwiched in between. The CERR has a cross sectional area where approximately the etched copper foil in ERR is now retained, and the remaining region is now etched. In contract with quarter-wavelength (λ/4) thickness which is required for conventional absorbers, the largest in-plane dimension and thickness of the SMA cell are only λ/33 and λ/250, respectively, leading to a super compact cell volume. While traditionally the long straight wire is introduced in electric-LC resonators for increasing inductance, the CERR achieves similar inductance with much shorter lengths. Thus, its cell dimensions can be drastically reduced without compromising its performance. In addition, simulations together with an automated phase correction algorithm show that the SMA is a type of metamaterial possessing simultaneous negative electric permittivity (NEP) and negative magnetic permeability (NMP). Further the SMA has a very large imaginary part of the NEP and NMP, resulting in significantly large imaginary part of the refractive index at resonant frequency. These properties are well suited to design excellent absorbers. In addition, numerical results demonstrate that the maximum absorption coefficient of the SMA can reach greater than 99% at resonant frequency, and the full-width half-maximum is roughly 1% of the operating frequency, and a wide incident angle of ±49° over 90% absorption. Meanwhile, it is pointed out that this type of absorber is rather sensitive to polarization characteristic of the incident electromagnetic wave.

36 MATERIALS SCIENCE↗