Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CCD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

An efficient low- and moderate-resolution spectrograph for the Hale telescope

A new low-to-moderate resolution spectrograph has been designed and built for the Cassegrain focus of the Hale 5.08-meter telescope. To maximize efficiency, resolution, and wavelength coverage the light is divided into two spectra regions by a dichroic filter behind the entrance slit, after which there are two completely separate spectrographs. The blue spectrograph operates from 3200 A to 5200 A while the red one goes from 5200 A to 10,000 A. The red detector is an 800 x 800 TI CCD while the blue detector is a 320 x 512 RCA CCD or a Shectrograph image pulse-counting system. A Boksenberg IPCS can also be mounted on the blue camera. The overall efficiency of the Cassegrain telescope, spectrographs, and CCD's combined, ranges from 5 percent to 13 percent between 3600 A and 8200 A. The spectrograph is usable from 3200 A to 10,400 A.

Oke, J. B.↗

An evaluation of an ICCD imager of dynamic range expansion technique and application of insitu procedures for life-time extension

Research toward practical implementation of the Intensified Charge Coupled Device (ICCD) as a photon-counting array detector for astronomy is reported. The first area of concentration was to determine the rate and extent of the lifetime limiting damage to the CCD caused by the impact of high energy electrons, and to find whether various methods of annealing the damage were productive. The second effort was to determine the performance of the ICCD in a photon-counting mode to produce extended dynamic range measurements. There are two main effects that appear as the practical results of the electron damage to the CCD. One is an increase in the leakage current, i.e., the normal thermal generation of charge carriers in the silicon that provides a background dark signal that adds to the light produced image. In an undamaged CCD, the leakage current is usually fairly uniform across the photosensitive area of the silicon chip, with the exception of various bright pixels which have an anomalous leakage current well above the overall level.

Currie, D. G.↗

Aluminum/ammonia heat pipe gas generation and long term system impact for the Space Telescope's Wide Field Planetary Camera

In the Space Telescope's Wide Field Planetary Camera (WFPC) project, eight heat pipes (HPs) are used to remove heat from the camera's inner electronic sensors to the spacecraft's outer, cold radiator surface. For proper device functioning and maximization of the signal-to-noise ratios, the Charge Coupled Devices (CCD's) must be maintained at -95 C or lower. Thermoelectric coolers (TEC's) cool the CCD's, and heat pipes deliver each TEC's nominal six to eight watts of heat to the space radiator, which reaches an equilibrium temperature between -15 C to -70 C. An initial problem was related to the difficulty to produce gas-free aluminum/ammonia heat pipes. An investigation was, therefore, conducted to determine the cause of the gas generation and the impact of this gas on CCD cooling. In order to study the effect of gas slugs in the WFPC system, a separate HP was made. Attention is given to fabrication, testing, and heat pipe gas generation chemistry studies.

Jones, J. A.↗

Isolation Mounting for Charge-Coupled Devices

CCD's suspended by wires under tension. Remote thermoelectric cooling of charge coupled device allows vibration isolating mounting of CCD assembly alone, without having to suspend entire mass and bulk of thermoelectric module. Mounting hardware simple and light. Developed for charge-coupled devices (CCD's) in infrared telescope support adaptable to sensors in variety of environments, e.g., sensors in nuclear reactors, engine exhausts and plasma chambers.

Goss, W. C.↗

Acousto-optic/CCD real-time SAR data processor

The SAR processor which uses an acousto-optic device as the input electronic-to-optical transducer and a 2-D CCD image sensor, which is operated in the time-delay-and-integrate (TDI) mode is presented. The CCD serves as the optical detector, and it simultaneously operates as an array of optically addressed correlators. The lines of the focused SAR image form continuously (at the radar PRF) at the final row of the CCD. The principles of operation of this processor, its performance characteristics, the state-of-the-art of the devices used and experimental results are outlined. The methods by which this processor can be made flexible so that it can be dynamically adapted to changing SAR geometries is discussed.

Psaltis, D.↗

Programmable scan/read circuitry for charge coupled device imaging detectors

A circuit for scanning and outputting the induced charges in a solid state charge coupled device (CCD) image detector is disclosed in an image detection system for use in a spacecraft attitude control system. The image detection system includes timing control circuitry for selectively controlling the output of the CCD detector so that video outputs are provided only with respect to induced charges corresponding to predetermined sensing element lines of the CCD detector. The timing control circuit and the analog to digital converter are controlled by a programmed microprocessor which defines the video outputs to be converted and further controls the timing control circuit so that no video outputs are provided during the delay associated with analog to digital conversion.

Salomon, P. M.↗

The Extended Range X-Ray Telescope center director's discretionary fund report

An Extended Range X-Ray Telescope (ERXRT) of high sensitivity and spatial resolution capable of functioning over a broad region of the X-ray/XUV portion of the spectrum has been designed and analyzed. This system has been configured around the glancing-incidence Wolter Type I X-ray mirror system which was flown on the Skylab Apollo Telescope Mount as ATM Experiment S-056. Enhanced sensitivity over a vastly broader spectral range can be realized by the utilization of a thinned, back-illuminated, buried-channel Charge Coupled Device (CCD) as the X-ray/XUV detector rather than photographic film. However, to maintain the high spatial resolution inherent in the X-ray optics when a CCD of 30 micron pixel size is used, it is necessary to increase the telescope plate scale. This can be accomplished by use of a glancing-incidence X-ray microscope to enlarge and re-focus the primary image onto the focal surface of the CCD.

Hoover, R. B.↗

Potential of CCDs for UV and X-ray plasma diagnostics

A program is under way to develop charge-coupled device (CCD) sensors for space-based X-ray astronomy imaging spectrometers. To date, laboratory line-emission spectra have been acquired throughout the range of 277 to 8000 eV (carbon through copper K-alpha emission) and CCD sensitivity has been demonstrated throughout the range of 1.1 through 8000 eV. Image resolution is excellent, limited almost entirely by the 15 micron pixel size. These results are presented and specialized techniques are described which permit such low energy response, high spectral resolution, and efficient charge collection. Finally, analysis is presented of one particular CCD characteristic which currently limits UV and X-ray performance: charge diffusion.

Janesick, J. R.↗

Nondispersive X-ray spectroscopy and imaging of plasmas using a charge-coupled device

A virtual-phase charge-coupled device (CCD) was used to obtain pinhole images and X-ray spectra of laser-produced, solid target plasmas. With the CCD used in the single-photon counting mode, the spectrum in the energy range 2-10 keV was obtained without a dispersive element. Typical spectra reveal two distinct temperatures: a cold component of approximately 200 eV and a hot component of approximately 5 keV. Also, multiline spectra comprising characteristic line emission (K alpha, K beta) from a multilayer target bombarded by beta-rays were recorded using a three-phase CCD. The results demonstrate the potential of CCDs as imaging spectrometers with application in space, laboratory, and fusion-plasma research.

Marsh, K.↗

Charge-coupled-device response to electron beam energies of less than 1 keV up to 20 keV

Recent developments of backside treatment for the backside-illuminated scientifc CCD imagers have shown near-theoretical efficiency even at the short wavelength region of the spectrum. By using SEM performance comparisons of backside-treated and untreated CCDs to an electron flux varying from 1 to 100 pA and beam energy ranging from less than 1 keV up to 20 keV are obtained. The theoretical analysis, the SEM testing procedure, and the quantum efficiency measurement results are presented. It is shown, for example, that the average quantum efficiency increases from less than 1 percent for an untreated CCD to nearly 40 percent for a backside-treated CCD at a beam energy of 1 kev.

Daud, Taher↗

Charge-coupled-device X-ray detector performance model

A model that predicts the performance characteristics of CCD detectors being developed for use in X-ray imaging is presented. The model accounts for the interactions of both X-rays and charged particles with the CCD and simulates the transport and loss of charge in the detector. Predicted performance parameters include detective and net quantum efficiencies, split-event probability, and a parameter characterizing the effective thickness presented by the detector to cosmic-ray protons. The predicted performance of two CCDs of different epitaxial layer thicknesses is compared. The model predicts that in each device incomplete recovery of the charge liberated by a photon of energy between 0.1 and 10 keV is very likely to be accompanied by charge splitting between adjacent pixels. The implications of the model predictions for CCD data processing algorithms are briefly discussed.

Bautz, M. W.↗

Lick Observatory charge-coupled-device data acquisition system

The Lick Observatory CCD data acquisition system is described, with some observational results to illustrate the system capability. The electronics for the CCD are subdivided into those attached to the dewar, a 'smart' controller near the dewar, and a computer connected by serial link to the smart controller. Software for the controller is in assembler code, while the software for data acquisition and on-line analysis is written in C and uses the UNIX operating system. The computers and controllers are programmed to recognize and operate several different types of CCD. Three separate instruments that use the CCDs are described briefly, together with examples of the data they produce.

Robinson, L. B.↗

Imaging and spectroscopy of Comet P/Halley

The goals of this investigation are the analysis of a large set of high-resolution echelle/reticon spectra, and the reduction and analysis of a set of narrow-band-filtered charge coupled device (CCD) images of Comet Halley taken during the preperihelion period at Oak Ridge Observatory by Dr. R. E. McCrosky. The scientific objectives associated with these goals are the determination of the spatial distributions of several important radicals, atoms and ions in the coma. These include C2, CN, C3, H2O(+) and CO(+) from the image data. The analysis of the neutral species distribution with Monte Carlo models will aid in the understanding of their production and decay mechanisms as well as serve as an important indicator of the physical conditions in the inner coma. The spatial distributions of the ions will serve as a guide to constrain the complex model necessary for understanding the interaction of the solar wind and the cometary ions. Work during this past year has been devoted largely to the reduction of the standard star photometry for the CCD image data set, as well as the re-flat-fielding of a number of the comet images. We are pleased to report that despite a number of setbacks and the small effort devoted to this work (2 1/2 months for the PI and a generous share of completely unsupported time by Dr. McCrosky) that this portion of the work has been successfully completed. The goals for the upcoming final year of this project (under a new project number) are to complete the calibration of the CCD image data for inclusion in the IHW archive, to analyze a select portion of the neutral radical images with our Monte Carlo models, and to present the results of the 6300/region spectra as a guide to low-resolution spectral observers in order to yield the unambiguous separation of the contributions of cometary O(1D), airglow O(1D), and the numerous NH2 lines in that region of the spectrum.

Combi, Michael R.↗

Programmable, four-channel, 128-sample, 40-Ms/s analog-ternary correlator

A four-channel analog-ternary CCD correlator that extends the state of the art in several important areas is discussed. Surface acoustic wave, acoustic charge transport, and CCD implementation technologies are compared, and the architecture of the CCD device is described. It is shown that, in addition to a sampling rate up to 40 Ms (megasamples) per second, a dynamic range of 66 dB, and nonlinearity below -50 dB, the device exhibits a level of integration and user-friendliness not previously available. The correlator is intended for use in communications and radar systems where pseudonoise codes are employed.

Munroe, Scott C.↗

Evaluation of large format electron bombarded virtual phase CCDs as ultraviolet imaging detectors

In conjunction with an external UV-sensitive cathode, an electron-bombarded CCD may be used as a high quantum efficiency/wide dynamic range photon-counting UV detector. Results are presented for the case of a 1024 x 1024, 18-micron square pixel virtual phase CCD used with an electromagnetically focused f/2 Schmidt camera, which yields excellent simgle-photoevent discrimination and counting efficiency. Attention is given to the vacuum-chamber arrangement used to conduct system tests and the CCD electronics and data-acquisition systems employed.

Opal, Chet B.↗

HII regions in dwarf irregular galaxies of the local group

Deep, narrowband H alpha Charge Coupled Device (CCD) surveys of HII regions were carried out in several dwarf irregular galaxies in and near the local group. Data are now complete for these galaxies: NGC 6822, GR 8, IC 10, IC 1613, Sextans A, Sextans B, and Sag Irr. Observations are complete for DDO 47, 53, 167, 168 and 187. Details of some of the results for the surveys completed so far are discussed. For NGC 6822, CCD survey at H alpha resulted in the detection of 145 HII regions in the local group irregular galaxy NGC 6822. Most of them are newly detected, faint surface-brightness objects. Positions, maps and dimensions are being published elsewhere. For GR 8, a deep narrowband H alpha imaging of the nearby dwarf irregular galaxy GR 8 revealed a total of 32 HII regions. Positions, H alpha luminosities, and sizes of these objects were determined. The H alpha luminosity function has the same shape as that for more luminous galaxies, except for size of sample effects. Most HII regions detected are at the very low luminosity end of the general luminosity function. For IC 10, a deep CCD narrowband H alpha imaging of the local group dwarf irregular galaxy IC 10 revealed a total of 144 HII regions. Positions, H alpha luminosities, and sizes of these objects were determined. The H alpha luminosity function has the same shape as that for more luminous galaxies.

Hodge, Paul↗

New advancements in charge-coupled device technology - Sub-electron noise and 4096 x 4096 pixel CCDs

This paper reports on two new advancements in CCD technology. The first area of development has produced a special purpose CCD designed for ultra low-signal level imaging and spectroscopy applications that require sub-electron read noise floors. A nondestructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are reported. The second development involves the design and performance of a high resolution imager of 4096 x 4096 pixels, the largest CCD manufactured in terms of pixel count. The device utilizes a 7.5-micron pixel fabricated with three-level poly-silicon to achieve high yield.

Janesick, James R.↗

Solar x ray astronomy rocket program

The dynamics were studied of the solar corona through the imaging of large scale coronal structures with AS&E High Resolution Soft X ray Imaging Solar Sounding Rocket Payload. The proposal for this program outlined a plan of research based on the construction of a high sensitivity X ray telescope from the optical and electronic components of the previous flight of this payload (36.038CS). Specifically, the X ray sensitive CCD camera was to be placed in the prime focus of the grazing incidence X ray mirror. The improved quantum efficiency of the CCD detector (over the film which had previously been used) allows quantitative measurements of temperature and emission measure in regions of low x ray emission such as helmet streamers beyond 1.2 solar radii or coronal holes. Furthermore, the improved sensitivity of the CCD allows short exposures of bright objects to study unexplored temporal regimes of active region loop evolution.

Source record↗