Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CASE METHOD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

Role of fourth-order phase-space moments in collective modes of trapped Fermi gases

We study the transition from hydrodynamic to collisionless behavior in collective modes of ultracold trapped Fermi gases. To that end, we solve the Boltzmann equation for the trapped Fermi gas via the moments method. We showed previously that it is necessary to go beyond second-order moments if one wants to reproduce the results of a numerical solution of the Boltzmann equation. Here, we will give the detailed description of the method including fourth-order moments. We apply this method to the case of realistic parameters, and compare the results for the radial quadrupole and scissors modes at unitarity to experimental data obtained by the Innsbruck group. It turns out that the inclusion of fourth-order moments clearly improves the agreement with the experimental data. In particular, the fourth-order moments reduce the effect of collisions and therefore partially compensate the effect of the enhanced in-medium cross section at low temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Case-Based Capture and Reuse of Aerospace Design Rationale

The goal of this project is to apply artificial intelligence techniques to facilitate capture and reuse of aerospace design rationale. The project applies case-based reasoning (CBR) and concept mapping (CMAP) tools to the task of capturing, organizing, and interactively accessing experiences or "cases" encapsulating the methods and rationale underlying expert aerospace design. As stipulated in the award, Indiana University and Ames personnel are collaborating on performance of research and determining the direction of research, to assure that the project focuses on high-value tasks. In the first five months of the project, we have made two visits to Ames Research Center to consult with our NASA collaborators, to learn about the advanced aerospace design tools being developed there, and to identify specific needs for intelligent design support. These meetings identified a number of task areas for applying CBR and concept mapping technology. We jointly selected a first task area to focus on: Acquiring the convergence criteria that experts use to guide the selection of useful data from a set of numerical simulations of high-lift systems. During the first funding period, we developed two software systems. First, we have adapted a CBR system developed at Indiana University into a prototype case-based reasoning shell to capture and retrieve information about design experiences, with the sample task of capturing and reusing experts' intuitive criteria for determining convergence (work conducted at Indiana University). Second, we have also adapted and refined existing concept mapping tools that will be used to clarify and capture the rationale underlying those experiences, to facilitate understanding of the expert's reasoning and guide future reuse of captured information (work conducted at the University of West Florida). The tools we have developed are designed to be the basis for a general framework for facilitating tasks within systems developed by the Advanced Design Technologies Testbed (ADTT) project at ARC. The tenets of our framework are (1) that the systems developed should leverage a designer's knowledge, rather than attempting to replace it; (2) that learning and user feedback must play a central role, so that the system can adapt to how it is used, and (3) that the learning and feedback processes must be as natural and as unobtrusive as possible. In the second funding period we will extend our current work, applying the tools to capturing higher-level design rationale.

Leake, David B.↗

A Method to Estimate Mean Position, Motion Magnitude, Motion Correlation, and Trajectory of a Tumor From Cone-Beam CT Projections for Image-Guided Radiotherapy

Purpose: To develop a probability-based method for estimating the mean position, motion magnitude, and trajectory of a tumor using cone-beam CT (CBCT) projections. Method and Materials: CBCT acquisition was simulated for more than 80 hours of patient-measured trajectories for thoracic/abdominal tumors and prostate. The trajectories were divided into 60-second segments for which CBCT was simulated by projecting the tumor position onto a rotating imager. Tumor (surrogate) visibility on all projections was assumed. The mean and standard deviation of the tumor position and motion correlation along the three axes were determined with maximum likelihood estimation based on the projection data, assuming a Gaussian spatial distribution. The unknown position component along the imager axis was approximated by its expectation value, determined by the Gaussian distribution. Transformation of the resulting three-dimensional position to patient coordinates provided the estimated trajectory. Two trajectories were experimentally investigated by CBCT acquisition of a phantom. Results: The root-mean-square error of the estimated mean position was 0.05 mm. The root-mean-square error of the trajectories was <1 mm in 99.1% of the thorax/abdomen cases and in 99.7% of the prostate cases. The experimental trajectory estimation agreed with the actual phantom trajectory within 0.44 mm in any direction. Clinical applicability was demonstrated by estimating the tumor trajectory for a pancreas cancer case. Conclusions: A method for estimation of mean position, motion magnitude, and trajectory of a tumor from CBCT projections has been developed. The accuracy was typically much better than 1 mm. The method is applicable to motion-inclusive, respiratory-gated, and tumor-tracking radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-H-BRC-03: Evaluation of Very High-Energy Electron (VHEE) Beams in Comparison to VMAT and PBS Treatment Plans

Purpose: The aim of this study was to evaluate the performance of very high-energy electron (VHEE) beams in comparison to clinically delivered treatment plans generated with volumetric modulated arc therapy (VMAT) and proton pencil beam scanning (PBS) technology. Methods: Three clinical cases were selected (prostate, lung, and pediatric CNS). The VHEE plans were calculated in the Monte Carlo EGSnrc code and pencil beam doses were calculated using the DOSxyznrc MC code for 100 and 200 MeV beams. Treatment plans with VHEE, VMAT, and PBS were optimized in a research version of RayStation using an in house build script in order to minimize operator bias between the different techniques. Results: For the prostate cancer case, the PBS plan showed lower mean organ at risk (OAR) doses compared to the other modalities. An exception was the femoral heads, due to the lateral beam arrangements. The VMAT plan showed lower mean doses to the rectum and the bladder compared to the 100 MeV VHEE plan. The lung cancer case showed minor differences between the three modalities. However, the PBS plan showed a lower contralateral lung dose. The pediatric CNS case showed a better conformity and lower spinal cord dose for the 100 MeV VHEE plan. For all cases, the 200 MeV VHEE plans were found to be similar to or better than the 100 MeV VHEE plans. Conclusion: The present study showed that VHEE plans are similar or superior to VMAT plans with reduced mean OAR dose and increased target conformity for a variety of clinical cases. With increased VHEE energy, better conformity and even higher reductions in mean OAR doses can be achieved. Funding: DoD, Award#:W81XWH-13-1-0165, Weston Havens Foundation, Bio-X (Stanford University), the Office of the Dean of the Medical School, the Office of the Provost (Stanford University), and the Swedish Childhood Cancer Foundation. BL and PM are founders of TibaRay,Inc. BL and PM have received research grants from Varian and RaySearch Laboratory.

60 APPLIED LIFE SCIENCES↗

Wave convection regimes in a binary mixture in a modulated gravitational field

Nonlinear wave convection regimes are studied in a horizontal layer of an incompressible binary mixture with anomalous thermal diffusion in the gravitational field modulated with an arbitrary amplitude and finite frequency. Oscillation regimes are numerically simulated by the finite difference method for the case of a layer with impenetrable rigid boundaries, which better corresponds to experimental laboratory conditions. A qualitative difference is found in the dynamics of nonlinear quasi-periodic and subharmonic oscillations appearing in the initially stratified mixture and behaving as modulated and regular standing waves. The dependences of the intensity of convective flows on the modulation amplitude are obtained. The results of nonlinear calculations are compared with data on the boundaries of the equilibrium stability found from the linear theory. It is shown that a region of parameters exists where alternating action suppresses the convective motion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Incorporating single-side sparing in models for predicting parotid dose sparing in head and neck IMRT

Purpose: Sparing of single-side parotid gland is a common practice in head-and-neck (HN) intensity modulated radiation therapy (IMRT) planning. It is a special case of dose sparing tradeoff between different organs-at-risk. The authors describe an improved mathematical model for predicting achievable dose sparing in parotid glands in HN IMRT planning that incorporates single-side sparing considerations based on patient anatomy and learning from prior plan data. Methods: Among 68 HN cases analyzed retrospectively, 35 cases had physician prescribed single-side parotid sparing preferences. The single-side sparing model was trained with cases which had single-side sparing preferences, while the standard model was trained with the remainder of cases. A receiver operating characteristics (ROC) analysis was performed to determine the best criterion that separates the two case groups using the physician's single-side sparing prescription as ground truth. The final predictive model (combined model) takes into account the single-side sparing by switching between the standard and single-side sparing models according to the single-side sparing criterion. The models were tested with 20 additional cases. The significance of the improvement of prediction accuracy by the combined model over the standard model was evaluated using the Wilcoxon rank-sum test. Results: Using the ROC analysis, the best single-side sparing criterion is (1) the predicted median dose of one parotid is higher than 24 Gy; and (2) that of the other is higher than 7 Gy. This criterion gives a true positive rate of 0.82 and a false positive rate of 0.19, respectively. For the bilateral sparing cases, the combined and the standard models performed equally well, with the median of the prediction errors for parotid median dose being 0.34 Gy by both models (p = 0.81). For the single-side sparing cases, the standard model overestimates the median dose by 7.8 Gy on average, while the predictions by the combined model differ from actual values by only 2.2 Gy (p = 0.005). Similarly, the sum of residues between the modeled and the actual plan DVHs is the same for the bilateral sparing cases by both models (p = 0.67), while the standard model predicts significantly higher DVHs than the combined model for the single-side sparing cases (p = 0.01). Conclusions: The combined model for predicting parotid sparing that takes into account single-side sparing improves the prediction accuracy over the previous model.

61 RADIATION PROTECTION AND DOSIMETRY↗

Nonlinear rescaling of control values simplifies fuzzy control

Traditional control theory is well-developed mainly for linear control situations. In non-linear cases there is no general method of generating a good control, so we have to rely on the ability of the experts (operators) to control them. If we want to automate their control, we must acquire their knowledge and translate it into a precise control strategy. The experts' knowledge is usually represented in non-numeric terms, namely, in terms of uncertain statements of the type 'if the obstacle is straight ahead, the distance to it is small, and the velocity of the car is medium, press the brakes hard'. Fuzzy control is a methodology that translates such statements into precise formulas for control. The necessary first step of this strategy consists of assigning membership functions to all the terms that the expert uses in his rules (in our sample phrase these words are 'small', 'medium', and 'hard'). The appropriate choice of a membership function can drastically improve the quality of a fuzzy control. In the simplest cases, we can take the functions whose domains have equally spaced endpoints. Because of that, many software packages for fuzzy control are based on this choice of membership functions. This choice is not very efficient in more complicated cases. Therefore, methods have been developed that use neural networks or generic algorithms to 'tune' membership functions. But this tuning takes lots of time (for example, several thousands iterations are typical for neural networks). In some cases there are evident physical reasons why equally space domains do not work: e.g., if the control variable u is always positive (i.e., if we control temperature in a reactor), then negative values (that are generated by equal spacing) simply make no sense. In this case it sounds reasonable to choose another scale u' = f(u) to represent u, so that equal spacing will work fine for u'. In the present paper we formulate the problem of finding the best rescaling function, solve this problem, and show (on a real-life example) that after an optimal rescaling, the un-tuned fuzzy control can be as good as the best state-of-art traditional non-linear controls.

Vanlangingham, H.↗

Consistent performance of large language models in rare disease diagnosis across ten languages and 4917 cases

Background Large language models (LLMs) are increasingly used medicine for diverse applications including differential diagnostic support. The training data used to create LLMs such as the Generative Pretrained Transformer (GPT) predominantly consist of English-language texts, but LLMs could be used across the globe to support diagnostics if language barriers could be overcome. Initial pilot studies on the utility of LLMs for differential diagnosis in languages other than English have shown promise, but a large-scale assessment on the relative performance of these models in a variety of European and non-European languages on a comprehensive corpus of challenging rare-disease cases is lacking. Methods We created 4917 clinical vignettes using structured data captured with Human Phenotype Ontology (HPO) terms with the Global Alliance for Genomics and Health (GA4GH) Phenopacket Schema. These clinical vignettes span a total of 360 distinct genetic diseases with 2525 associated phenotypic features. We used translations of the Human Phenotype Ontology together with language-specific templates to generate prompts in English, Chinese, Czech, Dutch, French, German, Italian, Japanese, Spanish, and Turkish. We applied GPT-4o, version gpt-4o-2024-08-06, and the medically fine-tuned Meditron3-70B to the task of delivering a ranked differential diagnosis using a zero-shot prompt. An ontology-based approach with the Mondo disease ontology was used to map synonyms and to map disease subtypes to clinical diagnoses in order to automate evaluation of LLM responses. Findings For English, GPT-4o placed the correct diagnosis at the first rank 19.9% and within the top-3 ranks 27.0% of the time. In comparison, for the nine non-English languages tested here the correct diagnosis was placed at rank 1 between 16.9% and 20.6%, within top-3 between 25.4% and 28.6% of cases. The Meditron3 model placed the correct diagnosis within the first 3 ranks for 20.9% of cases in English and between 19.9% and 24.0% for the other nine languages. Interpretation The differential diagnostic performance of LLMs across a comprehensive corpus of rare-disease cases was largely consistent across the ten languages tested. This suggests that the utility of LLMs in clinical settings may extend to non-English clinical settings.

Artificial intelligence↗

Benchmark Analysis of the HTR-10 with the MAMMOTH Reactor Physics Application

This report documents a set of benchmarks used to validate the Serpent and MAMMOTH neutron transport models of the HTR-10 reactor developed at Idaho National Laboratory. The high-fidelity Serpent Monte Carlo models of the HTR-10 critical and full core configurations include both random, discrete distributions of TRISO particles in the pebbles and random, discrete pebble distributions in the pebble bed core. The Serpent results agree very well with the critical and control rod worth measurements provided in the International Re- actor Physics Experiment Evaluation Project (IRPhEP) report if the ENDF/B-VII.r1 data- set is used. These Serpent models are subsequently used to prepare cross sections and flux tallies in a 10 coarse energy group structure for the MAMMOTH Reactor Physics MOOSE- based application. We find that MAMMOTH can reproduce the Monte Carlo solution for the HTR-10 reactor by using the PJFNK-SPH equivalence method. In all cases studied, the MAMMOTH results are within 120 pcm of the Monte Carlo reference calculation and the maximum errors in neutron absorption and generation rates are within 0.536% and 0.215% from the reference calculation, respectively. A set of benchmark exercises from the International Atomic Energy Agency (IAEA) HTR-10 benchmark in IAEA-TECDOC-1382 were conducted including parts B1 (critical), B2 (temperature coefficient) and B3 (control rod worth). The results we obtain for the critical core are in excellent agreement with the expected value and we confirm that with ENDF/B-VII.r1 data we match the critical eigen- value keff=1 to within 100 pcm. Our temperature coefficient calculation is consistent with the VSOP results generated by the German participants. The Chinese and South African VSOP models produce lower temperature coefficients, a fact that was noted in the original IAEA benchmark, but for which no explanation was provided. Both a full and single control rod worth calculations with Serpent and MAMMOTH agree well with the results from the IAEA benchmark. Finally, and most importantly, this work demonstrates that MAM- MOTH can recover the Monte Carlo high-fidelity solutions to an excellent accuracy using the PJFNK-SPH method. This sets the stage for the ultimate goal of using MAMMOTH in transient, multi-physics scenarios where correction of the cross sections is obtained for steady-state conditions and then used in the transient scenario for which no Monte-Carlo solution is available.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The importance of round-robin validation when assessing machine-learning-based vertical extrapolation of wind speeds

The extrapolation of wind speeds measured at a meteorological mast to wind turbine rotor heights is a key component in a bankable wind farm energy assessment and a significant source of uncertainty. Industry-standard methods for extrapolation include the power-law and logarithmic profiles. The emergence of machine-learning applications in wind energy has led to several studies demonstrating substantial improvements in vertical extrapolation accuracy in machine-learning methods over these conventional power-law and logarithmic profile methods. In all cases, these studies assess relative model performance at a measurement site where, critically, the machine-learning algorithm requires knowledge of the rotor-height wind speeds in order to train the model. This prior knowledge provides fundamental advantages to the site-specific machine-learning model over the power-law and log profiles, which, by contrast, are not highly tuned to rotor-height measurements but rather can generalize to any site. Furthermore, there is no practical benefit in applying a machine-learning model at a site where winds at the heights relevant for wind energy production are known; rather, its performance at nearby locations (i.e., across a wind farm site) without rotor-height measurements is of most practical interest. To more fairly and practically compare machine-learning-based extrapolation to standard approaches, we implemented a round-robin extrapolation model comparison, in which a random-forest machine-learning model is trained and evaluated at different sites and then compared against the power-law and logarithmic profiles. We consider 20 months of lidar and sonic anemometer data collected at four sites between 50 and 100 km apart in the central United States. We find that the random forest outperforms the standard extrapolation approaches, especially when incorporating surface measurements as inputs to include the influence of atmospheric stability. When compared at a single site (the traditional comparison approach), the machine-learning improvement in mean absolute error was 28 % and 23 % over the power-law and logarithmic profiles, respectively. Using the round-robin approach proposed here, this improvement drops to 20 % and 14 %, respectively. These latter values better represent practical model performance, and we conclude that round-robin validation should be the standard for machine-learning-based wind speed extrapolation methods.

17 WIND ENERGY↗

An (R, S)-norm fuzzy information measure with its applications in multiple-attribute decision-making

In this paper, we introduce a quantity measure which is called (R, S)-norm entropy and discuss some of its major properties with Shannon’s and other entropies in the literature. Based on this (R, S)-norm entropy, we have proposed a new (R, S)-norm fuzzy information measure and discussed its validity and properties. Further, we have given its comparison with other fuzzy information measures to prove its effectiveness. Attribute weights play an important role in multiple-attribute decision-making problems. In the present communication, two methods of determining the attribute weights are introduced. First is the case when the information regarding attribute weights is incompletely known or completely unknown and second is when we have partial information about attribute weights. For the first case, the extension of ordinary entropy weight method is used to calculate attribute weights and minimum entropy principle method based on solving a linear programming model is used in the second case. Finally, two methods are explained through numerical examples.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-T-35: An Investigation of the Accuracy of Cervical IMRT Dose Distribution Using 2D/3D Ionization Chamber Arrays System and Monte Carlo Simulation

Purpose: The purpose of this work is to compare the verification results of three solutions (2D/3D ionization chamber arrays measurement and Monte Carlo simulation), the results will help make a clinical decision as how to do our cervical IMRT verification. Methods: Seven cervical cases were planned with Pinnacle 8.0m to meet the clinical acceptance criteria. The plans were recalculated in the Matrixx and Delta4 phantom with the accurate plans parameters. The plans were also recalculated by Monte Carlo using leaf sequences and MUs for individual plans of every patient, Matrixx and Delta4 phantom. All plans of Matrixx and Delta4 phantom were delivered and measured. The dose distribution of iso slice, dose profiles, gamma maps of every beam were used to evaluate the agreement. Dose-volume histograms were also compared. Results: The dose distribution of iso slice and dose profiles from Pinnacle calculation were in agreement with the Monte Carlo simulation, Matrixx and Delta4 measurement. A 95.2%/91.3% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Pinnacle distributions within 3mm/3% gamma criteria. A 96.4%/95.6% gamma pass ratio was obtained between the Matrixx/Delta4 measurement and Monte Carlo simulation within 2mm/2% gamma criteria, almost 100% gamma pass ratio within 3mm/3% gamma criteria. The DVH plot have slightly differences between Pinnacle and Delta4 measurement as well as Pinnacle and Monte Carlo simulation, but have excellent agreement between Delta4 measurement and Monte Carlo simulation. Conclusion: It was shown that Matrixx/Delta4 and Monte Carlo simulation can be used very efficiently to verify cervical IMRT delivery. In terms of Gamma value the pass ratio of Matrixx was little higher, however, Delta4 showed more problem fields. The primary advantage of Delta4 is the fact it can measure true 3D dosimetry while Monte Carlo can simulate in patients CT images but not in phantom.

60 APPLIED LIFE SCIENCES↗

Program Helps Design Tests Of Developmental Software

Computer program called "A Formal Test Representation Language and Tool for Functional Test Designs" (TRL) provides automatic software tool and formal language used to implement category-partition method and produce specification of test cases in testing phase of development of software. Category-partition method useful in defining input, outputs, and purpose of test-design phase of development and combines benefits of choosing normal cases having error-exposing properties. Traceability maintained quite easily by creating test design for each objective in test plan. Effort to transform test cases into procedures simplified by use of automatic software tool to create cases based on test design. Method enables rapid elimination of undesired test cases from consideration and facilitates review of test designs by peer groups. Written in C language.

Hops, Jonathan↗

Application of the method of discrete ordinates to the solution of the transport equation in the case of an inhomogeneous planetary atmosphere

A version of the method of discrete ordinate (MDO) which can be used for an optically thick inhomogeneous atmosphere was developed. The MDO may be implemented as an algorithm simpler than those proposed earlier. The algorithm is the same for each azimuth dependent component of intensity. The MDO can determine the scattered radiation field over its entire length along the vertical. It is shown the MDO, when used for homogeneous atmospheres is in agreement with the results obtained by other methods.

Zasova, L. V.↗

COG Beta-Effective Benchmarks

COG 11.3 calculations with the “new method” using ENDF/B-VIII.0 data are shown to produce results with |C/E – 1| < 3σ in all cases, whereas the other methods produce a few minor outliers. Furthermore, the “new method” using ENDF/B-VIII.0 data is observed to produce “over” and “under” results consistent with 50/50 expectations whereas the other methods appear to be slightly over or under predicting. JEFF-3.3 results are slightly larger overall than ENDF/B-VIII.0 results. In all but a few cases, it is also observed that $F_d/F_t ≥ (vF)_d/(vF)_t ≥ 1 – (k_{prompt}/k_{eff})$ and all estimators produce equivalent results for the most thermal systems. In those other cases, this relation holds within the given statistics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Maximizing the biological effect of proton dose delivered with scanned beams via inhomogeneous daily dose distributions

Purpose: Biological effect of radiation can be enhanced with hypofractionation, localized dose escalation, and, in particle therapy, with optimized distribution of linear energy transfer (LET). The authors describe a method to construct inhomogeneous fractional dose (IFD) distributions, and evaluate the potential gain in the therapeutic effect from their delivery in proton therapy delivered by pencil beam scanning. Methods: For 13 cases of prostate cancer, the authors considered hypofractionated courses of 60 Gy delivered in 20 fractions. (All doses denoted in Gy include the proton's mean relative biological effectiveness (RBE) of 1.1.) Two types of plans were optimized using two opposed lateral beams to deliver a uniform dose of 3 Gy per fraction to the target by scanning: (1) in conventional full-target plans (FTP), each beam irradiated the entire gland, (2) in split-target plans (STP), beams irradiated only the respective proximal hemispheres (prostate split sagittally). Inverse planning yielded intensity maps, in which discrete position control points of the scanned beam (spots) were assigned optimized intensity values. FTP plans preferentially required a higher intensity of spots in the distal part of the target, while STP, by design, employed proximal spots. To evaluate the utility of IFD delivery, IFD plans were generated by rearranging the spot intensities from FTP or STP intensity maps, separately as well as combined using a variety of mixing weights. IFD courses were designed so that, in alternating fractions, one of the hemispheres of the prostate would receive a dose boost and the other receive a lower dose, while the total physical dose from the IFD course was roughly uniform across the prostate. IFD plans were normalized so that the equivalent uniform dose (EUD) of rectum and bladder did not increase, compared to the baseline FTP plan, which irradiated the prostate uniformly in every fraction. An EUD-based model was then applied to estimate tumor control probability (TCP) and normal tissue complication probability (NTCP). To assess potential local RBE variations, LET distributions were calculated with Monte Carlo, and compared for different plans. The results were assessed in terms of their sensitivity to uncertainties in model parameters and delivery. Results: IFD courses included equal number of fractions boosting either hemisphere, thus, the combined physical dose was close to uniform throughout the prostate. However, for the entire course, the prostate EUD in IFD was higher than in conventional FTP by up to 14%, corresponding to the estimated increase in TCP to 96% from 88%. The extent of gain depended on the mixing factor, i.e., relative weights used to combine FTP and STP spot weights. Increased weighting of STP typically yielded a higher target EUD, but also led to increased sensitivity of dose to variations in the proton's range. Rectal and bladder EUD were same or lower (per normalization), and the NTCP for both remained below 1%. The LET distributions in IFD also depended strongly on the mixing weights: plans using higher weight of STP spots yielded higher LET, indicating a potentially higher local RBE. Conclusions: In proton therapy delivered by pencil beam scanning, improved therapeutic outcome can potentially be expected with delivery of IFD distributions, while administering the prescribed quasi-uniform dose to the target over the entire course. The biological effectiveness of IFD may be further enhanced by optimizing the LET distributions. IFD distributions are characterized by a dose gradient located in proximity of the prostate's midplane, thus, the fidelity of delivery would depend crucially on the precision with which the proton range could be controlled.

60 APPLIED LIFE SCIENCES↗

Microbial Community Metabolic Modeling: A Community Data-Driven Network Reconstruction: COMMUNITY DATA-DRIVEN METABOLIC NETWORK MODELING

Metabolic network modeling of microbial communities provides an in-depth understanding of community-wide metabolic and regulatory processes. Compared to single organism analyses, community metabolic network modeling is more complex because it needs to account for interspecies interactions. To date, most approaches focus on reconstruction of high-quality individual networks so that, when combined, they can predict community behaviors as a result of interspecies interactions. However, this conventional method becomes ineffective for communities whose members are not well characterized and cannot be experimentally interrogated in isolation. Here, we tested a new approach that uses community-level data as a critical input for the network reconstruction process. This method focuses on directly predicting interspecies metabolic interactions in a community, when axenic information is insufficient. We validated our method through the case study of a bacterial photoautotroph-heterotroph consortium that was used to provide data needed for a community-level metabolic network reconstruction. Resulting simulations provided experimentally validated predictions of how a photoautotrophic cyanobacterium supports the growth of an obligate heterotrophic species by providing organic carbon and nitrogen sources.

compartmentalized metabolic network↗