Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CAMERAS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Long-wavelength 256x256 QWIP Hand-held Camera

In this paper, we discuss the development of very sensitive long wavelength infrared (LWIR) GaAs/AlxGa1-xAs quantum well infrared photodetectors (QWIPs), fabrication of random reflectors for efficient light coupling, and the demonstration of first hand-held long-wavelength 256x256 QWIP focal plane array camera. Excellent imagery, with a noise equivalent differential temperature of 25 mK has been achieved.

long↗

Optical Testing of MISR Lenses and Camera

A unique, highly automated thermal-vacuum facility for optical testing of lenses and cameras is described. In particular, measurements of MTF, boresight, and geometric image distortion over a large parameter space including wavelength, field of view and temperature will be discussed.

lens↗

Unsteady Pressure Sensitive Paint Camera Calibration Improvements

Data collection using unsteady pressure-sensitive paint (uPSP) has been greatly increased in recent large-scale demonstrations. With this significant increase comes challenges to process this magnitude of data. Techniques designed for several thousands of images collected in a lab do not necessarily scale to millions collected in a production-level system. Novel techniques are needed to meet the tighter requirements imposed on computation time, robustness, and accuracy. This paper outlines a number of such techniques and improvements in regards to the camera calibration process.

Camera calibration↗

Development of Level of Detail System and First-Person Camera for the GCAS Visualization Suite

The use of data-driven simulations has become standard practice as part of planning for future space missions. These simulations allow visualizing the data interactively to show what the data represents, as well as the importance of the data in the context of the mission. Using this visualized data can enhance users’ understanding of it and accelerate analysis efforts related to missions planned around it. Three-dimensional (3D) visualization software was developed to allow creating 3D representations of various communication systems, as well as the physical terrain of the Moon, for upcoming missions. The goal of this software development effort was to create interactive visualization capabilities in the Glenn Research Center Communication Analysis Suite (GCAS) using data exported from MATLAB® (MathWorks, Inc.) scripts. This software had the functionality to visualize the line of sight and dynamic link margins of the communication satellites orbiting the Earth and the Moon. One important addition to this was the visualization of the terrain data located within the GeoTIFF files, which were produced in an effort to understand the Moon’s terrain. Proper displacement values of this data have to be visualized to showcase where craters are located and how the shadow casting works with said craters at different points of the day, as well as analysis of possible landing sites for future lunar expeditions. The graphics library coded in JavaScript, three.js, had been previously selected for developing this visualization software. The software was revised to conform to modern standards, then further developed to convert the MATLAB® data into JavaScript 3D objects and Blender GL Transmission Format Binary file (GLB) objects, which were to be imported into the scene. In the process, a variety of other testing projects were created to be combined with this project at a later point; these included the first-person camera movements around spherical objects to portray human movement around the Moon, GeoTIFF loading methods, data transfer methods for incorporating the elevation data into the scene, and level of detail (LOD) capabilities to decrease memory usage and rendering time.

Visualization↗

Semi-automatic image annotation using 3D LiDAR projections and depth camera data

Efficient image annotation is necessary to utilize deep learning object recognition neural networks in nuclear safeguards, such as for the detection and localization of target objects like nuclear material containers (NMCs). This capability can help automate the inventory accounting of different types of NMCs within nuclear storage facilities. The conventional manual annotation process is labor-intensive and time-consuming, hindering the rapid deployment of deep learning models for NMC identifications. This paper introduces a novel semi-automatic method for annotating 2D images of nuclear material containers (NMCs) by combining 3D light detection and ranging (LiDAR) data with color and depth camera images collected from a handheld scan system. The annotation pipeline involves an operator manually marking new target objects on a LiDAR-generated map, and projecting these 3D locations to images, thereby automatically creating annotations from the projections. The semi-automatic approach significantly reduces manual efforts and the expertise in image annotation that is required to perform the task, allowing deep learning models to be trained on-site within a few hours. The paper compares the performance of models trained on datasets annotated through various methods, including semi-automatic, manual, and commercial annotation services. The evaluation demonstrates that the semi-automatic annotation method achieves comparable or superior results, with a mean average precision (mAP) above 0.9, showcasing its efficiency in training object recognition models. Additionally, the paper explores the application of the proposed method to instance segmentation, achieving promising results in detecting multiple types of NMCs in various formations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays

COCOA (COmpact COmpton cAmera) is a next-generation gamma-ray telescope designed for astrophysical observations in the MeV energy range. The detector comprises a scatterer volume employing the LiquidO detection technology and an array of scintillating crystals acting as absorber. Surrounding plastic scintillator panels serve as a veto system for charged particles. The detector's compact, scalable design enables flexible deployment on microsatellites or high-altitude balloons. Gamma rays at MeV energies have not been well explored historically (the so-called "MeV gap") and COCOA has the potential to improve the sensitivity in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

Predicting melt pool depth and grain length using multiple signatures from in-situ single camera two-wavelength imaging pyrometry for laser powder bed fusion

In laser powder bed fusion (LPBF), the in-situ process signatures are known to have a direct correlation with the microstructural properties of the solidified melt pool (MP). It is known that the MP cooling and heating rates, and laser processing parameters can critically determine the grain structure and thereby affect the part properties. The objective of this work is to study the feasibility of using in-process, high-speed imaging pyrometry for evaluating the solidified MP properties “below” the surface, such as depth and microstructural properties. To accomplish this, we employ an in-house single camera-based two-wavelength imaging pyrometry (STWIP) system for monitoring the printing of single-scan tracks with Inconel 718 on a commercial LPBF printer (EOS M290). Further, the lab designed STWIP system is a coaxial high-speed (>10,000 fps) imaging system capable of monitoring MP temperature, morphology, and intensity profiles. The temperature measurements from STWIP are emissivity independent. The STWIP measured MP signatures of the printed tracks are correlated with the ex-situ microscopy characterized MP depth and the average grain lengths. From the data analysis, using support vector machine (SVM)-based regression models, we found that the MP temperature signatures are crucial for an accurate prediction of MP depth and the grain length, thus validating the novelty and necessity of the developed in-situ monitoring methods and analysis.

36 MATERIALS SCIENCE↗

Spectroscopic camera analysis of the roles of molecularly assisted reaction chains during detachment in JET L-mode plasmas

The roles of the molecularly assisted ionization (MAI), recombination (MAR) and dissociation (MAD) reaction chains with respect to the purely atomic ionization and recombination processes were studied experimentally during detachment in low-confinement mode (L-mode) plasmas in JET with the help of experimentally inferred divertor plasma and neutral conditions, extracted previously from filtered camera observations of deuterium Balmer emission, and the reaction coefficients provided by the ADAS, AMJUEL and H2VIBR atomic and molecular databases. The direct contribution of MAI and MAR in the outer divertor particle balance was found to be inferior to the electron–atom ionization (EAI) and electron–ion recombination (EIR). Near the outer strike point, a strong atom source due to the D$^+_2$ -driven MAD was, however, observed to correlate with the onset of detachment at outer strike point temperatures of T e,osp = 0.9 –2.0 eV via increased plasma-neutral interactions before the increasing dominance of EIR at T e,osp < 0.9 eV, followed by increasing degree of detachment. The analysis was supported by predictions from EDGE2D-EIRENE simulations which were in qualitative agreement with the experimental observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Addressing the impact of Lyman opacity in inference of divertor plasma conditions with 2D spectroscopic camera analysis of Balmer emission during detachment in JET L-mode plasmas

The impact of re-absorption of the deuterium Lyman series emission was addressed in inferring divertor plasma conditions from Balmer series emission with 2D spectroscopic camera analysis during detachment in JET L-mode plasmas. The previously presented methodology was amended by modifying the standard photon emission coefficients and ionization and recombination rate coefficients of the ADAS database to consider the re-population of excited states due to Lyman opacity. This resulted in the estimate for the atomic density near the outer strike point to decrease by up to 75% at the onset of detachment at strike point temperatures of T e,osp ≈ 1.0–3.0 eV with respect to the strongly overestimated previously obtained values, whereas the estimated electron temperature and density were unaffected by the opacity correction within the scatter of the data and only a moderate reduction by up to 20% was observed in the estimate for the molecularly induced fraction of the Balmer emission. No noticeable change was seen in the ionization rate, calculated from the estimated outer strike point conditions, due to the decrease in the atomic density estimate compensating for the increased values of the opacity-corrected ADAS rate coefficients for ionization. In detached conditions at T e,osp ≈ 0.5–1.0 eV, 25%–35% lower recombination rates were provided by the opacity-corrected model. The observed effects on the experimental analysis were supported by a corresponding synthetic analysis based on EDGE2D-EIRENE simulations.

Balmer emission↗

Scaling Individual Tree Transpiration With Thermal Cameras Reveals Interspecies Differences to Drought Vulnerability

Abstract Understanding tree transpiration variability is vital for assessing ecosystem water‐use efficiency and forest health amid climate change, yet most landscape‐level measurements do not differentiate individual trees. Using canopy temperature data from thermal cameras, we estimated the transpiration rates of individual trees at Harvard Forest and Niwot Ridge. PT‐JPL model was used to derive latent heat flux from thermal images at the canopy‐level, showing strong agreement with tower measurements ( R 2 = 0.70–0.96 at Niwot, 0.59–0.78 at Harvard at half‐hourly to monthly scales) and daily RMSE of 33.5 W/m 2 (Niwot) and 52.8 W/m 2 (Harvard). Tree‐level analysis revealed species‐specific responses to drought, with lodgepole pine exhibiting greater tolerance than Engelmann spruce at Niwot and red oak showing heightened resistance than red maple at Harvard. These findings show how ecophysiological differences between species result in varying responses to drought and demonstrate that these responses can be characterized by deriving transpiration from crown temperature measurements.

Javadian, Mostafa↗

A room-temperature polarization-sensitive CMOS terahertz camera based on quantum-dot-enhanced terahertz-to-visible photon upconversion

Detection of terahertz (THz) radiation has many potential applications, but presently available detectors are limited in many aspects of their performance, including sensitivity, speed, bandwidth and operating temperature. Most do not allow the characterization of THz polarization states. Recent observation of THz-driven luminescence in quantum dots offers a possible detection mechanism via field-driven interdot charge transfer. Here, we demonstrate a room-temperature complementary metal–oxide–semiconductor THz camera and polarimeter based on quantum-dot-enhanced THz-to-visible upconversion mechanism with optimized luminophore geometries and fabrication designs. Besides broadband and fast responses, the nanoslit-based sensor can detect THz pulses with peak fields as low as 10 kV cm–1. A related coaxial nanoaperture-type device shows a to-date-unexplored capability to simultaneously record the THz polarization state and field strength with similar sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Large field-of-view event-mode camera for high-precision epithermal neutron resonance imaging

A large-area event-mode camera system coupled with a 6 LiF-ZnS:Ag scintillator is applied for neutron resonance imaging (NRI) on the energy-resolved neutron imaging (ERNI) flight path, also known as Flight Path 5 (FP5), at the Los Alamos Neutron Science Center (LANSCE). This novel neutron imaging system, featuring a 120 x 120 mm 2 field of view, efficiently captures resonance information across the entire image in a single acquisition, significantly reducing beam time requirements compared to conventional energy-resolved neutron imaging systems. High-quality neutron radiographs with enhanced spatial resolution are achieved through the reconstruction of neutron events based on observations of individual photons emitted from the scintillator. The system demonstrates reduced background through neutron/gamma discrimination capabilities while maintaining sharpness across a large fields of view. In the measurements presented here, a spatial resolution of approximately 340 μm was achieved using center-of-gravity photon cluster centroiding. We demonstrate the system’s capability for quantitatively determining isotopic distributions in various thin samples, as well as automatically reconstructing complex scenes with overlapping resonances from diverse samples. These results are obtained using standard data analysis tools, despite the relatively slow 6 LiF-ZnS:Ag scintillator, which may not be optimal for absorption resonance detection. The capabilities demonstrated here offer a valuable, versatile, and cost-effective solution for high spatial and temporal resolution, large field-of-view energy-resolved neutron imaging, with potential applications across various scientific and industrial domains.

36 MATERIALS SCIENCE↗

Energy-resolved neutron imaging and diffraction including grain orientation mapping using event camera technology

Time-of-flight neutron diffraction and energy-resolved imaging each provide unique perspectives into material properties. Neutron diffraction is useful for assessing microstructural parameters such as phase composition, texture, and dislocation densities, though it typically provides averaged data over the sampled volume. Energy-resolved imaging, on the other hand, offers both spatial and spectral information by detecting Bragg edges and neutron absorption resonances, which enables detailed mapping of microstructure and isotopic composition. When combined, these techniques have the potential to enrich our understanding of material behavior across different scales, enhancing our understanding of complex materials. Traditionally, these modalities are conducted on separate instruments, which is time-consuming and poses challenges for data integration. Here, we report the integration of the LumaCam, an event-mode energy-resolved neutron imaging camera with the HIPPO time-of-flight diffractometer at LANSCE. This integration enables simultaneous diffraction and imaging across the full spectrum, with analysis optimized for diffraction and Bragg-edge imaging in the thermal range (0.45–10 Å) and resonance imaging in the epithermal range (0.5–3000 eV), facilitating comprehensive multi-modal analysis. We demonstrate its capabilities through case studies, including spatial mapping of grain orientations in a steel sample and accurate thickness estimations for irregular samples including a depleted uranium cylinder and a natural silver-containing mineral specimen. The combined setup enhances real-time sample alignment and provides comprehensive data for crystal structure, texture, and isotopic composition analysis. This approach opens new possibilities for advanced applications in nuclear engineering, archaeology, and materials science.

36 MATERIALS SCIENCE↗

Inferred UV fluence focal-spot profiles from soft x-ray pinhole-camera measurements on OMEGA

A method was developed with laser-irradiated Au planar foils to characterize the focal spot of UV laser beams on target at full energy from soft x-ray emission. A pinhole camera with a back-thinned charge-coupled–device detector and filtration with thin Be and Al foil filters provides images of the x-ray emission at photon energies <2 keV. This method requires a careful measurement of the relation between the applied UV fluence and the x-ray signal, which can be described by a power-law dependence. The measured exponent γ ~ 2 provides a dynamic range of ~25 for the inferred UV fluence. UV fluence profiles of selected beams were measured for 100-ps and 1-ns laser pulses and were compared to directly measured profiles from an UV equivalent-target-plane diagnostic. The inferred spot size and super-Gaussian order from the x-ray technique agree within several percent with the values measured with the direct UV measurements.

47 OTHER INSTRUMENTATION↗