Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Buildings”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Pathway for decarbonizing residential building operations in the US and China beyond the mid-century

With global carbon budget targets looming, residential buildings in top economies must become carbon neutral as soon as possible to reserve more emission space for emerging carbon-emitting economies. This study is the first to compare the operational decarbonization process of China’s and the United States (US) residential buildings from 2000 to 2060 by combining the end-use emission model with the decomposing structural decomposition (DSD) method and Monte Carlo simulation. The results show that from 2001 to 2020 China decarbonized 1544 mega-tons of carbon dioxide (MtCO 2 ) and the US decarbonized 1848 MtCO 2 . In the business-as-usual scenario, China will hit its emission peak in 2031 (±3) with 934 (±61) MtCO 2 , while the US will maintain a lock-in level of 736 (±133) MtCO 2 since the 2030s. In the decarbonization scenario, operational carbon neutrality for residential buildings in 2060 is promoted by an increase in clean power generation proportion, building-integrated power generation level, building electrification level, and a reduction in end-use energy intensity, which will contribute 34.4 %, 21.4 %, 14.3 %, and 29.9 % in China and 32.9 %, 33.1 %, 8.2 %, and 25.8 % in the US, respectively. Especially, building-integrated power generation in China only costs about 40 % of what it costs in the US. Besides, high-decarbonization strategies for residential building operations are proposed as references for governments to formulate targeted climate policies. Overall, this study offers data benchmarks for buildings’ carbon neutrality of top economies to further promote synergistic carbon neutrality with the buildings of emerging economies in the age of Post COP27.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Protecting building occupants against the inhalation of outdoor-origin aerosols

During normal operations, buildings can protect their occupants from outdoor airborne particle hazards of all types, including airborne pollutants. A long-term international research effort has advanced our knowledge of building protection physics. Recently we have developed an operationally efficient, regional-scale methodology - Regional Shelter Analysis - to account for both building protection effects and the typical distribution of people in and among buildings. To provide input to this capability, we estimate here the degree of protection afforded by the currently existing US building stock. Here, we first assemble and summarize the published literature relevant to indoor particle losses including (a) deposition to indoor surfaces, (b) losses that occur when particles penetrate through the building envelope, and (c) heating, ventilation and air conditioning (HVAC) system filtration efficiencies as well as general building operating conditions. Building protection against inhaling particulate hazards varies strongly, by orders of magnitude, according to particle size, airborne particle loss rate, and to a lesser extent building use (occupancy). Protection increases modestly as particle size increases from 0.1 to 1 μm and significantly as particle size increases from 1 to 10 μm. Model results are placed in context with previously reported measurements. Suggestions for future work, including enhanced validation datasets are provided.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hybrid LCA model for assessing the embodied environmental impacts of buildings in South Korea

The assessment of the embodied environmental impacts of buildings can help decision-makers plan environment-friendly buildings and reduce environmental impacts. For a more comprehensive assessment of the embodied environmental impacts of buildings, a hybrid life cycle assessment model was developed in this study. The developed model can assess the embodied environmental impacts (global warming, ozone layer depletion, acidification, eutrophication, photochemical ozone creation, abiotic depletion, and human toxicity) generated directly and indirectly in the material manufacturing, transportation, and construction phases. To demonstrate the application and validity of the developed model, the environmental impacts of an elementary school building were assessed using the developed model and compared with the results of a previous model used in a case study. The embodied environmental impacts from the previous model were lower than those from the developed model by 4.6–25.2%. Particularly, human toxicity potential (13 kg C{sub 6}H{sub 6} eq.) calculated by the previous model was much lower (1965 kg C{sub 6}H{sub 6} eq.) than what was calculated by the developed model. The results indicated that the developed model can quantify the embodied environmental impacts of buildings more comprehensively, and can be used by decision-makers as a tool for selecting environment-friendly buildings. - Highlights: • The model was developed to assess the embodied environmental impacts of buildings. • The model evaluates GWP, ODP, AP, EP, POCP, ADP, and HTP as environmental impacts. • The model presents more comprehensive results than the previous model by 4.6–100%. • The model can present the HTP of buildings, which the previous models cannot do. • Decision-makers can use the model for selecting environment-friendly buildings.

54 ENVIRONMENTAL SCIENCES↗

Enhancing EnergyPlus capabilities to model dynamic building envelopes using python plugin

Nearly half of the energy consumption in the United States is related to buildings, resulting in an urgent need to develop innovative technologies to improve building energy efficiency. Dynamic building envelopes, comprising switchable insulation and thermal energy storage materials, have been proposed recently as a promising solution to reduce buildings' heating and cooling loads by thermally coupling the indoor environment with the ambient environment when beneficial while decoupling them when outdoor conditions are not favorable. Although various related technologies are still underway, the whole-building energy modeling tools, like EnergyPlus, do not have the capability to simulate the transient and dynamic nature of dynamic envelope materials and components to accurately predict their impact on building energy use. The objective of this study is to formulate a method in EnergyPlus simulation engine to model multilayer envelopes, comprising dynamic building materials with variable thermophysical properties, and discuss the changes made to the program using a Python plugin. Furthermore, the thermal performance of the dynamic envelopes using the proposed method is compared and verified with the results from a well-established commercial code, COMSOL Multiphysics. A parametric assessment is also conducted to evaluate the energy efficiency benefits of dynamic envelopes in a single-family residential building, demonstrating total annual energy savings up to 11.6 %, when a dynamic envelope operates alone, and up to 18.2 % when it is combined with a thin layer of phase change material as a thermal storage medium. Finally, a United States wide energy efficiency assessment is presented to showcase the geographical spread of the energy savings. The method designed and implemented in this study provides the researchers with the ability to implement their dynamic insulation methods in EnergyPlus and evaluate the whole building energy impact.

25 ENERGY STORAGE↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cloud-based implementation of white-box model predictive control for a GEOTABS office building: A field test demonstration

Model predictive control (MPC) has been proven in simulations and pilot case studies to be a superior control strategy for large buildings. MPC can utilize the weather and occupancy schedule forecasts, together with the system model, to predict the future thermal behavior of the building and minimize the overall energy use and maximize thermal comfort. However, these advantages come with the cost of increased modeling effort, computational demands, communication infrastructure, and commissioning efforts. Thus a typical approach is to, often rapidly, simplify the building modeling and MPC optimization problem while paying a price of not reaching the full performance potential. It has been shown that by employing accurate physics-based models, MPC performance can be notably increased closer to its theoretical performance bound. However, implementation of such high-fidelity MPC in real buildings remains a challenge, resulting in a lack of successful field test studies. This work presents the methodology and field test demonstration of a computationally efficient implementation of the white-box MPC in an office building in Belgium. The detailed model of the building is based on first-principle physical equations. The deployment and supervision of MPC operation in a practical setting are supported by an automated cloud-based communication infrastructure. The motivating factor behind the cloud-based architecture is its compatibility with a commercially appealing control as a service concept. The building is equipped with a ground source heat pump (GSHP) and thermally activated building structures (TABS), where the combination of both is also known as GEOTABS. From a control perspective, GEOTABS buildings are particularly challenging systems due to large scale, complex heating, ventilation and air conditioning (HVAC) system, and slow dynamics with time delays. On the other hand, there is an increased potential for energy savings due to the high thermal mass, which acts as thermal storage. The MPC operation is demonstrated during the challenging transient seasons (switching between heating and cooling), and its performance is compared to a traditional rule-based controller (RBC). We provide a proof of concept of real MPC operation for the most difficult seasons with notable GSHP energy use savings equal to 53.5% and thermal comfort improvement by 36.9%. Other MPC applications found in the literature describe tests for only cooling or only heating, and up to now only for a black-box or a grey-box approach.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Localized Actual Meteorological Year File Creator (LAF): A tool for using locally observed weather data in building energy simulations

The Localized Actual Meteorological Year File Creator (LAF) application provides web-based access to real meteorological data and processes it into a weather file suitable for building energy modeling. Building energy consumption is affected by what is inside the building (such as occupants, appliances, HVAC systems, etc.) and by what is outside: the weather conditions the building is exposed to. However, freely available weather data files are limited to a number of specific locations, usually airports, which are often located away from city centers where buildings are concentrated. The authors have developed a new tool that supports the investigation and quantification of micro-climate conditions on building energy consumption. LAF is built on the Python open-source programming language and has a Graphical User Interface (GUI) that allows users to create custom weather data files for building energy simulations. Many sets of actual meteorological year weather data for long time periods are publicly available online (such as the MesoWest database) for thousands of locations in the US. LAF selects weather data according to user specifications and automatically processes it through an API across multiple weather stations and multiple time periods. The user may easily select a specific location, time frame, and time step that best meets their needs. This article presents a useful tool for energy modelers, building designers and operators to assist with building performance analysis and optimization.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Inferring building height from footprint morphology data

As cities continue to grow globally, characterizing the built environment is essential to understanding human populations, projecting energy usage, monitoring urban heat island impacts, preventing environmental degradation, and planning for urban development. Buildings are a key component of the built environment and there is currently a lack of data on building height at the global level. Current methodologies for developing building height models that utilize remote sensing are limited in scale due to the high cost of data acquisition. Other approaches that leverage 2D features are restricted based on the volume of ancillary data necessary to infer height. Here, we find, through a series of experiments covering 74.55 million buildings from the United States, France, and Germany, it is possible, with 95% accuracy, to infer building height within 3 m of the true height using footprint morphology data. Our results show that leveraging individual building footprints can lead to accurate building height predictions while not requiring ancillary data, thus making this method applicable wherever building footprints are available. The finding that it is possible to infer building height from footprint data alone provides researchers a new method to leverage in relation to various applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling of two-storey precast school building using Ruaumoko 2D program

The long-distant earthquake loading from Sumatra and Java Island had caused some slight damages to precast and reinforced concrete buildings in West Malaysia such as cracks on wall panels, columns and beams. Subsequently, the safety of existing precast concrete building is needed to be analyzed because these buildings were designed using BS 8110 which did not include the seismic loading in the design. Thus, this paper emphasizes on the seismic performance and dynamic behavior of precast school building constructed in Malaysia under three selected past earthquakes excitations ; El Centro 1940 North-South, El Centro East-West components and San Fernando 1971 using RUAUMOKO 2D program. This program is fully utilized by using prototype precast school model and dynamic non-linear time history analysis. From the results, it can be concluded that two-storey precast school building has experienced severe damage and partial collapse especially at beam-column joint under San Fernando and El Centro North-South Earthquake as its exceeds the allowable inter-storey drift and displacement as specified in Eurocode 8. The San Fernando earthquake has produced a massive destruction to the precast building under viscous damping, ξ = 5% and this building has generated maximum building displacement of 435mm, maximum building drift of 0.68% and maximum bending moment at 8458kNm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing Facility Operations by Applying Machine Learning to the Army Reserve Enterprise Building Control System (Final Report)

Thousands of U.S. Department of Defense (DoD) buildings have building automation systems (BASs) and/or advanced meters. Although these systems have a wealth of data, performance optimization requires time and expertise to review and act on that information. Machine learning (ML) can provide automated and actionable insights to controls operators. This demonstration implemented proven ML methods on the Army Reserve Enterprise Building Control System. ML refers to algorithms that “learn” from data and improve their performance on a given task over time. In the buildings domain these tasks range from predicting future energy consumption, to identifying operational issues before faults occur, to optimizing control decisions. To learn, ML requires input data, which – for buildings – typically consists of instrument data such as energy consumption data and subsystem controls information such as set-point temperatures, and context data consisting of information such as the physical location of the building, the area of the building, and the weather. ML models use the relationships learned from the input data to make predictions with new, previously unseen, data. The team was able to investigate and successfully implement the following ML use cases: labeling consumption data as anomalous or non-anomalous; baseline whole-building load prediction (unknown fault status); fault detection (validation not possible); and site prioritization for energy-related projects. Due to the constraints of the project, interventions were not able to be implemented during the demonstration; therefore, assessments of operational cost savings and maintenance avoided could not be performed. The project has been presented at two leading national building conferences and two additional publications to peer-reviewed journals are currently in preparation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resilience Issues in Building Energy Codes

This report, prepared for the International Energy Agency’s Building Energy Codes Working Group (BECWG, part of the IEA Energy in Buildings and Communities Technical Collaboration Programme, or IEA EBC), focuses on the application of building energy codes to improve the ability of buildings to provide a minimum healthy level of thermal comfort and function during extreme events. It reviews the relationship of building energy codes to the other building resilience policies and strategies, such as other building life/safety codes, community planning or zoning to discourage rebuilding in areas most prone to climate disasters, and other resilience planning strategies. The report provides an overview of how different jurisdictions address resilience issues in building energy codes in countries that are part of the IEA EBC Building Energy Codes Working Group.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Case Study about Energy and Cost Impacts for Different Community Scenarios Using a Community-Scale Building Energy Modeling Tool

The United States building sector consumed approximately 75% of electricity in 2019. By implementing renewable energy technologies and control strategies into buildings, future buildings will serve as energy generators as well as consumers. To accommodate this transition, communications among buildings and between buildings and the grid could provide more possibilities to optimize the energy performance of buildings. This paper develops a community-scale building energy model tool and conducts a case study adopting behind-the-meter distributed energy resources, sharing energy in different buildings, and using different electricity tariff structures. Three scenarios are studied: (1) electricity only supplied by the grid, (2) photovoltaic (PV) panels installed on and available to some but not all buildings, and (3) a connected community. To consider the impacts of locations and energy tariffs, this paper selects four cities and three electricity tariffs to evaluate the energy and cost performances of these three scenarios. The results show that the PV panels in Scenario 2 reduce 25% to 33% of the community-level electricity consumption and 20% to 30% of the community-level electricity cost compared with Scenario 1 in all studied locations and energy tariffs. By considering power management in the connected community (Scenario 3), the electricity consumption and cost can be further reduced by 6% to 7% and 5% to 11%, respectively, compared with Scenario 2.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advances in the Co-Simulation of Detailed Electrical and Whole-Building Energy Performance

This article describes recent co-simulation advances for the simultaneous modeling of detailed building electrical distribution systems and whole-building energy performance. The co-simulation architecture combines the EnergyPlus® engine for whole-building energy modeling with a new Modelica library for building an electrical distribution system model that is based on harmonic power flow. This new library allows for a higher-fidelity modeling of electrical power flows and losses within buildings than is available with current building electrical modeling software. We demonstrate the feasibility of the architecture by modeling a simple, two-zone thermal chamber with internal power electronics converters and resistive loads, and we validate the model using experimental data. The proposed co-simulation capability significantly expands the capabilities of building electrical distribution system models in the context of whole-building energy modeling, thus enabling more complex analyses than would have been possible with individual building performance simulation tools that are used to date.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scout: An Impact Analysis Tool for Building Energy-Efficiency Technologies

Evaluating the national impacts of candidate U.S. building energy-efficiency technologies has historically been difficult for organizations with large energy efficiency portfolios. In particular, normalizing results from technology-specific impact studies is time-consuming when those studies do not use comparable assumptions about the underlying building stock. To equitably evaluate its technology research, development, and deployment portfolio, the U.S. Department of Energy's Building Technologies Office has developed Scout, a software tool that quantitatively assesses the energy and CO2 impacts of building energy-efficiency measures on the national building stock. Scout efficiency measures improve upon the unit performance and/or lifetime operational costs of an equipment stock baseline that is determined from the U.S. Energy Information Administration Annual Energy Outlook (AEO). Scout measures are characterized by a market entry and exit year, unit performance level, cost, and lifetime. To evaluate measures on a consistent basis, Scout uses EnergyPlus simulation on prototype building models to translate measure performance specifications to whole-building energy savings; these savings impacts are then extended to a national scale using floor area weighting factors. Scout represents evolution in the building stock over time using AEO projections for new construction, retrofit, and equipment replacements, and competes technologies within market segments under multiple adoption scenarios. Scout and its efficiency measures are open-source, as is the EnergyPlus whole building simulation framework that is used to evaluate measure performance. The program is currently under active development and will be formally released once an initial set of measures has been analyzed and reviewed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Envelope Characteristics in Cold Climates

Prescriptive guidelines for thermal insulation in the design of buildings in cold climates have traditionally been derived by a holistic consideration of climatic factors, energy policy, environmental policy, and economics. The differences in thermal barrier requirements in buildings across the arctic and subarctic regions of the world are influenced as much by the differing priorities of the governing bodies that set these requirements as by actual physical demands and conditions. Usually, national requirements for building envelope characteristics such as thermal insulation values, building envelope airtightness, vapor permeability, building mass, and detailing are based on economics, durability, and environmental considerations. Consideration of thermal energy system resilience provides a new paradigm through which to view the optimization of these parameters. The paper describes specifics of construction in cold climates; summarizes best practice requirements for the building envelope characteristics for buildings located in cold and arctic climate of the United States, Canada, and Scandinavian countries; provides some details illustrating how to implement these requirements; and compares the effects of different levels of building envelope efficiency and building mass on indoor air temperature decay when heat supply is interrupted. The paper also presents results from experts' discussions during the consultation forum "Thermal Energy Systems Resilience in Cold/Arctic Climates" (ERDC 2020) and research conducted under the IEA EBC Annex 73, the Environmental Security Technology Certification Program (ESTCP) Project "Technologies Integration to Achieve Resilient, Low-Energy Military Installations," and U.S. Army Program project 633734T1500 under Military Engineering Technology Demonstration. The paper complements the Cold-Climate Design Guide (ASHRAE 2015) with a focus on the resilience of thermal energy systems.

Arctic↗

New U.S. Data Tools are Playing a Crucial Role in Decarbonizing Buildings at Speed, Scale, and Low Cost

Preparing buildings for retrofits traditionally requires expensive on-site audits or timeintensive simulation models. As a result, the majority of buildings fail to pursue cost-saving retrofits. To address these barriers, the U.S. Department of Energy (DOE) has introduced the Building Efficiency Targeting Tool for Energy Retrofits (BETTER)-a new, free, on-line tool that utilizes a data-driven analytical engine and user-friendly web interface to automatically analyze a building's monthly energy usage in response to weather conditions. The tool benchmarks a building's electric and fossil energy usage against peers; estimates energy, cost, and emissions reductions at the building and portfolio levels; recommends energy efficiency measures; and prioritizes buildings for net-zero energy retrofits. Thanks to interoperability with the DOE's Standard Energy Efficiency Data (SEED) platform, BETTER is supporting U.S. jurisdictions to prepare buildings for retrofit at speed, scale, and low cost to comply with energy policies. This paper discusses the use of BETTER and SEED by one of the branches of the California state government to streamline a retrofit program across 455 public non-residential buildings to align with state goals to reduce greenhouse gas emissions. It describes the organization's challenge to reduce energy consumption across a geographically diverse, aging portfolio; explores how BETTER and SEED improved workflow efficiency; presents preliminary results, including avoiding audit costs of $3.28 million and developing the groundwork for retrofit projects estimated to prevent emission of 2,271 t CO2e annually; and provides guidance for other jurisdictions seeking similar results.

BETTER↗

Urban microclimate and its impact on building performance: A case study of San Francisco

Urban microclimate exerts an increasing influence on urban buildings, energy, and sustainability. This study uses 10-year measured hourly weather data at 27 sites in San Francisco, California, to (1) analyze and visualize the urban microclimate patterns and urban heat island effect; (2) simulate annual energy use and peak electricity demand of typical large office buildings and large hotels to investigate the influence of urban microclimate on building performance; (3) simulate indoor air temperature of a single-family house without air-conditioning during the record three-day heatwave of 2017, to quantify the divergence of climate resilience due to urban microclimate effect. Results show significant microclimate effects in San Francisco with up to 11 °C outdoor air temperature difference between the coastal and downtown areas on September 1, 2017, during the record three-day heatwave. The simulated energy results of the prototype large office and large hotel buildings using the 2017 weather data show over 100% difference in annual heating energy use and 65% difference in annual cooling energy use across different stations; as well as up to 30% difference in peak cooling electricity demand. The impacts on annual site or source energy use are minimal (less than 5%) as cooling and heating in a mild climate are a relatively small portion of overall building energy use in San Francisco. Results also show the microclimate effects influence indoor air temperature of unconditioned homes by up to 5 °C. Newer buildings and homes are much less affected by microclimate effects due to more stringent performance requirements of the building envelope and energy systems. Furthermore, these findings inform that San Francisco microclimate variations should be considered in urban energy planning, building energy codes and standards, as well as heat resilience policymaking.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗