Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BODY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Efficacy of Lower-Body Shielding in Computed Tomography Fluoroscopy-Guided Interventions

Purpose: Computed tomography (CT) fluoroscopy-guided interventions pose relevant radiation exposure to the interventionalist. The goal of this study was to analyze the efficacy of lower-body shielding as a simple structural method for decreasing radiation dose to the interventionalist without limiting access to the patient. Material and Methods: All examinations were performed with a 128-slice dual source CT scanner (12 Multiplication-Sign 1.2-mm collimation; 120 kV; and 20, 40, 60, and 80 mAs) and an Alderson-Rando phantom. Scatter radiation was measured with an ionization chamber and a digital dosimeter at standardized positions and heights with and without a lower-body lead shield (0.5-mm lead equivalent; Kenex, Harlow, UK). Dose decreases were computed for the different points of measurement. Results: On average, lower-body shielding decreased scatter radiation by 38.2% within a 150-cm radius around the shielding. This decrease is most significant close to the gantry opening and at low heights of 50 and 100 cm above the floor with a maximum decrease of scatter radiation of 95.9% close to the scanner's isocentre. With increasing distance to the gantry opening, the effect decreased. There is almost no dose decrease effect at {>=}150 above the floor. Scatter radiation and its decrease were linearly correlated with the tube current-time product (r{sup 2} = 0.99), whereas percent scatter radiation decrease was independent of the tube current-time product. Conclusion: Lower-body shielding is an effective way to decrease radiation exposure to the interventionalist and should routinely be used in CT fluoroscopy-guided interventions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Techniques for Intravascular Foreign Body Retrieval

As endovascular therapies increase in frequency, the incidence of lost or embolized foreign bodies is increasing. The presence of an intravascular foreign body (IFB) is well recognized to have the potential to cause serious complications. IFB can embolize and impact critical sites such as the heart, with subsequent significant morbidity or mortality. Intravascular foreign bodies most commonly result from embolized central line fragments, but they can originate from many sources, both iatrogenic and noniatrogenic. The percutaneous approach in removing an IFB is widely perceived as the best way to retrieve endovascular foreign bodies. This minimally invasive approach has a high success rate with a low associated morbidity, and it avoids the complications related to open surgical approaches. We examined the characteristics, causes, and incidence of endovascular embolizations and reviewed the various described techniques that have been used to facilitate subsequent explantation of such materials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fluoroscopy-Guided Percutaneous Vertebral Body Biopsy Using a Novel Drill-Powered Device: Technical Case Series

BackgroundA novel coaxial biopsy system powered by a handheld drill has recently been introduced for percutaneous bone biopsy. This technical note describes our initial experience performing fluoroscopy-guided vertebral body biopsies with this system, compares the yield of drill-assisted biopsy specimens with those obtained using a manual technique, and assesses the histologic adequacy of specimens obtained with drill assistance.MethodsMedical records of all single-level, fluoroscopy-guided vertebral body biopsies were reviewed. Procedural complications were documented according to the Society of Interventional Radiology classification. The total length of bone core obtained from drill-assisted biopsies was compared with that of matched manual biopsies. Pathology reports were reviewed to determine the histologic adequacy of specimens obtained with drill assistance.ResultsTwenty eight drill-assisted percutaneous vertebral body biopsies met study inclusion criteria. No acute complications were reported. Of the 86 % (24/28) of patients with clinical follow-up, no delayed complications were reported (median follow-up, 28 weeks; range 5–115 weeks). The median total length of bone core obtained from drill-assisted biopsies was 28 mm (range 8–120 mm). This was longer than that obtained from manual biopsies (median, 20 mm; range 5–45 mm; P = 0.03). Crush artifact was present in 11 % (3/28) of drill-assisted biopsy specimens, which in one case (3.6 %; 1/28) precluded definitive diagnosis.ConclusionsA drill-assisted, coaxial biopsy system can be used to safely obtain vertebral body core specimens under fluoroscopic guidance. The higher bone core yield obtained with drill assistance may be offset by the presence of crush artifact.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Robotically Assisted Sonic Therapy (RAST) for Noninvasive Hepatic Ablation in a Porcine Model: Mitigation of Body Wall Damage with a Modified Pulse Sequence

Purpose: Robotically assisted sonic therapy (RAST) is a nonthermal, noninvasive ablation method based on histotripsy. Prior animal studies have demonstrated the ability to create hepatic ablation zones at the focal point of an ultrasound therapy transducer; however, these treatments resulted in thermal damage to the body wall within the path of ultrasound energy delivery. The purpose of this study was to evaluate the efficacy and safety of a pulse sequence intended to mitigate prefocal body wall injury. Materials and Methods: Healthy swine (n = 6) underwent hepatic RAST (VortxRx software version 1.0.1.3, HistoSonics, Ann Arbor MI) in the right hepatic lobe. A 3.0 cm spherical ablation zone was prescribed for each. Following treatment, animals underwent MRI which was utilized for ablation zone measurement, evaluation of prefocal injury, and assessment of complications. Each animal was euthanized, underwent necropsy, and the tissue was processed for histopathologic analysis of the ablation zone and any other sites concerning for injury. Results: No prefocal injury was identified by MRI or necropsy in the body wall or tissues overlying the liver. Ablation zones demonstrated uniform cell destruction, were nearly spherical (sphericity index = 0.988), and corresponded closely to the prescribed size (3.0 × 3.1 × 3.4 cm, p = 0.70, 0.36, and 0.01, respectively). Ablation zones were associated with portal vein (n = 3, one occlusive) and hepatic vein thrombosis (n = 4, one occlusive); however, bile ducts remained patent within ablation zones (n = 2). Conclusions: Hepatic RAST performed with a modified ultrasound pulse sequence in a porcine model can mitigate prefocal body wall injuries while maintaining treatment efficacy. Further study of hepatic RAST appears warranted, particularly in tumor models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Nonclassical Fracture Problems for Prestressed Bodies with Interacting Cracks

We consider two types of nonclassical fracture mechanisms, namely, the fracture of cracked bodies with initial (residual) stresses acting along the crack planes and the fracture of solids under compression along parallel cracks. To investigate nonaxisymmetric and axisymmetric problems for infinite solids containing two parallel coaxial cracks or a periodic set of coaxial parallel cracks, we use a combined analytic-numerical method within the framework of the three-dimensional linearized mechanics of solids. The analysis involves the representation of stresses and displacements in the linearized theory via harmonic potential functions. With the use of the integral Fourier–Hankel transformations, the problems are reduced to the solution of Fredholm integral equations of the second kind. This approach allows us to investigate problems in a unified general form for compressible and noncompressible homogeneous isotropic or transversely isotropic elastic bodies with an arbitrary structure of the elastic potential, and the material specification of the model is carried out only in the stage of numerical analysis of the resolving equations obtained in the general form. The effects of initial stresses on the stress intensity factors are analyzed for highly elastic materials and layered composites (modeled as transversely isotropic elastic bodies). The “resonance-like” effects are revealed when compressive initial stresses reach the values corresponding to the local loss of stability of the material in the vicinity of cracks, which, according to the indicated combined method, allows one to determine the critical (limiting) load parameters under the conditions of compression of the body along the cracks. The conclusions concerning the dependences of the stress intensity factors and critical (limiting) parameters of compression on the geometric parameters of the problems are formulated as well as concerning the dependences on physical and mechanical characteristics of the materials.

42 ENGINEERING↗

Whole Body MRI: Non-oncological Musculoskeletal Applications

Purpose of the Review: Whole-body MRI is an emerging imaging technique on continuous evolution, used in many oncologic indications and introduced more recently in rheumatologic and systemic disorders. In this article, we review the recent musculoskeletal applications of this technique outside the field of cancer. Recent Findings: Whole-body MRI, with its high sensitivity to bone marrow and soft-tissue alterations, and ability of extensive body coverage, is progressively regarded as an effective and powerful imaging tool for the detection, staging, and monitoring under treatment of many rheumatic diseases and systemic pathologies affecting the musculoskeletal system. Disease specific imaging protocols have been designed. Summary: Whole-body MRI is an appealing, non-irradiating tool emerging in musculoskeletal imaging. It is becoming the imaging of choice in several non-oncologic indications, and its application field is on continuous expansion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of n-3PUFAs on autophagy and inflammation of hypothalamus and body weight in mice

Highlights: • The effect of fat-1 gene on body weight is achieved via regulating expression of inflammatory and autophagy in hypothalamus. • The body weight, body and the Lee’s index are decreased in fat-1 transgenic mice. • The autophagy increased and the inflammation decreased in hypothalamus of fat-1 transgenic mice. Fat-1 transgenic mice were used as a model to study the effect of endogenous n-3 polyunsaturated fatty acids (n-3PUFAs) on the body weight, inflammatory factors and autophagy proteins in hypothalamus to explore the mechanism of n-3PUFAs inhibiting obesity.

60 APPLIED LIFE SCIENCES↗

A MPET 2 -mPBPK model for subcutaneous injection of biotherapeutics with different molecular weights: From local scale to whole-body scale

Subcutaneous injection of biotherapeutics has attracted considerable attention in the pharmaceutical industry. However, there is limited understanding of the mechanisms underlying the absorption of drugs with different molecular weights and the delivery of drugs from the injection site to the targeted tissue. Here, we propose the MPET 2 -mPBPK model to address this issue. This multiscale model couples the MPET 2 model, which describes subcutaneous injection at the local tissue scale from a biomechanical view, with a post-injection absorption model at injection site and a minimal physiologically-based pharmacokinetic (mPBPK) model at whole-body scale. Utilizing the principles of tissue biomechanics and fluid dynamics, the local MPET 2 model provides solutions that account for tissue deformation and drug absorption in local blood vessels and initial lymphatic vessels during injection. Additionally, we introduce a model accounting for the molecular weight effect on the absorption by blood vessels, and a nonlinear model accounting for the absorption in lymphatic vessels. The post-injection model predicts drug absorption in local blood vessels and initial lymphatic vessels, which are integrated into the whole-body mPBPK model to describe the pharmacokinetic behaviors of the absorbed drug in the circulatory and lymphatic system. We establish a numerical model which links the biomechanical process of subcutaneous injection at local tissue scale and the pharmacokinetic behaviors of injected biotherapeutics at whole-body scale. With the help of the model, we propose an explicit relationship between the reflection coefficient and the molecular weight and predict the bioavalibility of biotherapeutics with varying molecular weights via subcutaneous injection. The considered drug absorption mechanisms enable us to study the differences in local drug absorption and whole-body drug distribution with varying molecular weights. This model enhances the understanding of drug absorption mechanisms and transport routes in the circulatory system for drugs of different molecular weights, and holds the potential to facilitate the application of computational modeling to drug formulation.

59 BASIC BIOLOGICAL SCIENCES↗

Irradiation of Spinal Metastases: Should We Continue to Include One Uninvolved Vertebral Body Above and Below in the Radiation Field?

Purpose: Historically, the appropriate target volume to be irradiated for spinal metastases is 1-2 vertebral bodies above and below the level of involvement for three reasons: (1) to avoid missing the correct level in the absence of simulation or (2) to account for the possibility of spread of disease to the adjacent level, and (3) to account for beam penumbra. In this study, we hypothesized that isolated failures occurring in the level adjacent to level treated with stereotactic body radiosurgery (SBRS) were infrequent and that with improved localization techniques with image-guided radiation therapy, treatment of only the involved level of spinal metastases may be more appropriate. Methods and Materials: Patients who had received SBRS treatments to only the involved level of the spine as part of a prospective trial for spinal metastases comprised the study population. Follow-up imaging with spine MRI was performed at 3-month intervals following initial treatment. Failures in the adjacent (V{+-}1, V{+-}2) and distant spine were identified and classified accordingly. Results: Fifty-eight patients met inclusion criteria for this study and harbored 65 distinct spinal metastases. At 18-month median follow-up, seven (10.7%) patients failed simultaneously at adjacent levels V{+-}1 and at multiple sites throughout the spine. Only two (3%) patients experienced isolated, solitary adjacent failures at 9 and 11 months, respectively. Conclusion: Isolated local failures of the unirradiated adjacent vertebral bodies may occur in <5% of patients with isolated spinal metastasis. On the basis of the data, the current practice of irradiating one vertebral body above and below seems unnecessary and could be revised to irradiate only the involved level(s) of the spine metastasis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Localization Accuracy and Immobilization Effectiveness of a Stereotactic Body Frame for a Variety of Treatment Sites

Purpose: The purpose of this study was to analyze the pretreatment setup errors and intrafraction motion using cone beam computed tomography (CBCT) for stereotactic body radiation therapy patients immobilized and localized with a stereotactic body frame for a variety of treatment sites. Methods and Materials: Localization errors were recorded for patients receiving SBRT for 141 lung, 29 liver, 48 prostate, and 45 spine tumors representing 1005 total localization sessions. All patients were treated in a stereotactic body frame with a large custom-molded vacuum pillow. Patients were first localized to the frame using tattoos placed during simulation. Subsequently, the frame was aligned to the room lasers according to the stereotactic coordinates determined from the treatment plan. Every patient received a pretreatment and an intrafraction CBCT. Abdominal compression was used for all liver patients and for approximately 40% of the lung patients to reduce tumor motion due to respiration. Results: The mean ± standard deviation pretreatment setup errors from all localizations were −2.44 ± 3.85, 1.31 ± 5.84, and 0.11 ± 3.76 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean pretreatment localization results among all treatment sites were not significantly different (F test, P<.05). For all treatment sites, the mean ± standard deviation intrafraction shifts were 0.33 ± 1.34, 0.15 ± 1.45, and −0.02 ± 1.17 mm in the anteroposterior, superoinferior, and lateral directions, respectively. The mean unidimensional intrafraction shifts were statistically different for several of the comparisons (P<.05) as assessed by the Tukey-Kramer test. Conclusions: Despite the varied tumor locations, the pretreatment mean localization errors for all sites were found to be consistent among the treatment sites and not significantly different, indicating that the body frame is a suitable immobilization and localization device for a variety of tumor sites. Our pretreatment localization errors and intrafraction shifts compare favorably with those reported in other studies using different types of immobilization devices.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Body Radiation Therapy for Oligometastatic Prostate Cancer

Purpose: To review outcomes of patients with oligometastatic prostate cancer (PCa) treated with stereotactic body radiation therapy (SBRT) and to identify variables associated with local failure. Methods and Materials: We retrospectively reviewed records of patients treated with SBRT for oligometastatic PCa. Metastasis control (ie, control of the treated lesion, MC), biochemical progression-free survival, distant progression-free survival, and overall survival were estimated with the Kaplan-Meier method. Results: Sixty-six men with 81 metastatic PCa lesions, 50 of which were castrate-resistant, were included in the analysis. Lesions were in bone (n=74), lymph nodes (n=6), or liver (n=1). Stereotactic body radiation therapy was delivered in 1 fraction to 71 lesions (88%), at a median dose of 16 Gy (range, 16-24 Gy). The remaining lesions received 30 Gy in 3 fractions (n=6) or 50 Gy in 5 fractions (n=4). Median follow-up was 16 months (range, 3-49 months). Estimated MC at 2 years was 82%. Biochemical progression-free survival, distant progression-free survival, and overall survival were 54%, 45%, and 83%, respectively. On multivariate analysis, only the dose of SBRT was significantly associated with MC; lesions treated with 16 Gy had 58% MC, and those treated with ≥18 Gy had 95% MC at 2 years (P≤.001). At 2 years, MC for lesions treated with 18 Gy (n=21) was 88%. No patient treated with ≥18 Gy in a single fraction or with any multifraction regimen had local failure. Six patients (9%) had grade 1 pain flare, and 2 (3%) had grade 2 pain flare. No grade 2 or greater late toxicities were reported. Conclusions: Stereotactic body radiation therapy for patients with oligometastatic prostate cancer provided optimal metastasis control and acceptable toxicity with doses ≥18 Gy. Biochemical progression-free survival was 54% at 16 months with the inclusion of SBRT in the treatment regimen. Stereotactic body radiation therapy should be considered in patients with castration-refractory, oligometastatic prostate cancer who have limited options for systemic therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Study of Pseudoprogression After Spine Stereotactic Body Radiation Therapy

Purpose: To determine the incidence of pseudoprogression (PP) after spine stereotactic body radiation therapy based on a detailed and quantitative assessment of magnetic resonance imaging (MRI) morphologic tumor alterations, and to identify predictive factors distinguishing PP from local recurrence (LR). Methods and Materials: A retrospective analysis of 35 patients with 49 spinal segments treated with spine stereotactic body radiation therapy, from 2009 to 2014, was conducted. The median number of follow-up MRI studies was 4 (range, 2-7). The gross tumor volumes (GTVs) within each of the 49 spinal segments were contoured on the pretreatment and each subsequent follow-up T1- and T2-weighted MRI sagittal sequence. T2 signal intensity was reported as the mean intensity of voxels constituting each volume. LR was defined as persistent GTV enlargement on ≥2 serial MRI studies for ≥6 months or on pathologic confirmation. PP was defined as a GTV enlargement followed by stability or regression on subsequent imaging within 6 months. Kaplan-Meier analysis was used for estimation of actuarial local control, disease-free survival, and overall survival. Results: The median follow-up was 23 months (range, 1-39 months). PP was identified in 18% of treated segments (9 of 49) and LR in 29% (14 of 49). Earlier volume enlargement (5 months for PP vs 15 months for LR, P=.005), greater GTV to reference nonirradiated vertebral body T2 intensity ratio (+30% for PP vs −10% for LR, P=.005), and growth confined to 80% of the prescription isodose line (80% IDL) (8 of 9 PP cases vs 1 of 14 LR cases, P=.002) were associated with PP on univariate analysis. Multivariate analysis confirmed an earlier time to volume enlargement and growth within the 80% IDL as significant predictors of PP. LR involved the epidural space in all but 1 lesion, whereas PP was confined to the vertebral body in 7 of 9 cases. Conclusions: PP was observed in 18% of treated spinal segments. Tumor growth confined to the 80% IDL and earlier time to tumor enlargement were predictive for PP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An immersed interface method for the 2D vorticity-velocity Navier-Stokes equations with multiple bodies

We present an immersed interface method for the vorticity-velocity form of the 2D Navier Stokes equations that directly addresses challenges posed by nonconvex immersed bodies, multiply connected domains, and the calculation of force distributions on immersed surfaces. The immersed interface method is re-interpreted as a polynomial extrapolation of flow quantities and boundary conditions into the immersed solid bodies, reducing computational cost and enabling simulations with nonconvex bodies that could not be discretized with previous immersed interface methods. In the flow, the vorticity transport equation is discretized using a conservative finite difference scheme and explicit Runge-Kutta time integration. The velocity reconstruction problem is transformed to a scalar Poisson equation that is discretized with conservative finite differences, and solved using an FFT-accelerated iterative algorithm. The use of conservative differencing throughout leads to exact enforcement of a discrete Kelvin's theorem, allowing for simulations with multiply connected domains and outflow boundaries that have challenged other immersed interface vortex methods. We also explore novel methods for recovering time-dependent pressure distributions on immersed bodies within a vorticity-based method and present a novel control volume formulation for recovering aerodynamic moments from only the vorticity and velocity fields. The method achieves second order spatial accuracy and third order temporal accuracy, and is validated on a variety of 2D flows in internal and free-space domains.

97 MATHEMATICS AND COMPUTING↗

A sharp interface Lagrangian-Eulerian method for flexible-body fluid-structure interaction

This paper introduces a sharp-interface approach to simulating fluid-structure interaction (FSI) involving flexible bodies described by general nonlinear material models and across a broad range of mass density ratios. This new flexible-body immersed Lagrangian-Eulerian (ILE) scheme extends our prior work on integrating partitioned and immersed approaches to rigid-body FSI. Our numerical approach incorporates the geometrical and domain solution flexibility of the immersed boundary (IB) method with an accuracy comparable to body-fitted approaches that sharply resolve flows and stresses up to the fluid-structure interface. Unlike many IB methods, our ILE formulation uses distinct momentum equations for the fluid and solid subregions with a Dirichlet-Neumann coupling strategy that connects fluid and solid subproblems through simple interface conditions. As in earlier work, we use approximate Lagrange multiplier forces to treat the kinematic interface conditions along the fluid-structure interface. This penalty approach simplifies the linear solvers needed by our formulation by introducing two representations of the fluid-structure interface, one that moves with the fluid and another that moves with the structure, that are connected by stiff springs. This approach also enables the use of multi-rate time stepping, which allows us to use different time step sizes for the fluid and structure subproblems. Our fluid solver relies on an immersed interface method (IIM) for discrete surfaces to impose stress jump conditions along complex interfaces while enabling the use of fast structured-grid solvers for the incompressible Navier-Stokes equations. The dynamics of the volumetric structural mesh are determined using a standard finite element approach to large-deformation nonlinear elasticity via a nearly incompressible solid mechanics formulation. This formulation also readily accommodates compressible structures with a constant total volume, and it can handle fully compressible solid structures for cases in which at least part of the solid boundary does not contact the incompressible fluid. Selected grid convergence studies demonstrate second-order convergence in volume conservation and in the pointwise discrepancies between corresponding positions of the two interface representations as well as between first and second-order convergence in the structural displacements. The time stepping scheme is also demonstrated to yield second-order convergence. To assess and validate the robustness and accuracy of the new algorithm, comparisons are made with computational and experimental FSI benchmarks. Test cases include both smooth and sharp geometries in various flow conditions. Furthermore, we also demonstrate the capabilities of this methodology by applying it to model the transport and capture of a geometrically realistic, deformable blood clot in an inferior vena cava filter.

97 MATHEMATICS AND COMPUTING↗

A sharp immersed method for 2D flow-body interactions using the vorticity-velocity Navier-Stokes equations

Immersed methods discretize boundary conditions for complex geometries on background Cartesian grids. Here, this makes such methods especially suitable for two-way coupled flow-body problems, where the body mechanics are partially driven by hydrodynamic forces. However, for the vorticity-velocity form of the Navier-Stokes equations, existing immersed geometry discretizations for two-way coupled problems only achieve first order spatial accuracy near solid boundaries. Here we introduce a sharp-interface approach based on the immersed interface method to handle the one- and two-way coupling between an incompressible flow and one or more rigid bodies using the 2D vorticity-velocity Navier-Stokes equations. Our main contributions are three-fold. First, we develop and analyze a moving boundary treatment for sharp immersed methods that can be applied to PDEs with implicitly defined boundary conditions, such as those commonly imposed on the vorticity field. Second, we develop a two-way coupling methodology for the vorticity-velocity Navier-Stokes equations based on control-volume momentum balance that does not require the pressure field. Third, we show through extensive testing and validation that our resulting flow-body solver reaches second-order accuracy for most practical scenarios, and provides significant efficiency benefits compared to a representative first-order approach.

42 ENGINEERING↗

Characterization of the porous structures of the green body and sintered biomedical titanium scaffolds with micro-computed tomography

The present research was aimed at gaining an understanding of the porous structure changes from the green body through water leaching and sintering to titanium scaffolds. Micro-computed tomography (micro-CT) was performed to generate 3D models of titanium scaffold preforms containing carbamide space-holding particles and sintered scaffolds containing macro- and micro-pores. The porosity values and structural parameters were determined by means of image analysis. The result showed that the porosity values, macro-pore sizes, connectivity densities and specific surface areas of the titanium scaffolds sintered at 1200 °C for 3 h did not significantly deviate from those of the green structures with various volume fractions of the space holder. Titanium scaffolds with a maximum specific surface area could be produced with an addition of 60–65 vol% carbamide particles to the matrix powder. The connectivity of pores inside the scaffold increased with rising volume fraction of the space holder. The shrinkage of the scaffolds prepared with > 50 vol% carbamide space holder, occurring during sintering, was caused by the reductions of macro-pore sizes and micro-pore sizes as well as the thickness of struts. In conclusion, the final porous structural characteristics of titanium scaffolds could be estimated from those of the green body. - Highlights: •Porous structures of green body and sintered titanium scaffolds was studied. •Porous structures of both samples were quantitatively characterized with micro-CT. •Porous structures of scaffolds could be controlled from the green body. •Shrinkage mechanisms of titanium scaffolds during sintering was established.

36 MATERIALS SCIENCE↗

An improved understanding of the natural resonances of moonpools contained within floating rigid-bodies: Theory and application to oscillating water column devices

The fundamental interactions between waves, a floating rigid-body, and a moonpool that is selectively open to atmosphere or enclosed to purposefully induce pressure fluctuations are investigated. The moonpool hydrodynamic characteristics and the hydrodynamic coupling to the rigid-body are derived implicitly through reciprocity relations on an array of field points. By modeling the free surface of the moonpool in this manner, an explicit hydrodynamic coupling term is included in the equations of motion. This coupling results in the migration of the moonpool's natural resonance frequency from the piston frequency to a new frequency when enclosed in a floating rigid-body. Two geometries that highlight distinct aspects of marine vessels and oscillating water column (OWC) renewable energy devices are analyzed to reveal the coupled natural resonance migration. The power performance of these two OWCs in regular waves is also investigated. The air chamber is enclosed and a three-dimensional, linear, frequency domain performance model that links the rigid-body to the moonpool through a linear resistive control strategy is detailed. Furthermore, an analytic expression for the optimal linear resistive control values in regular waves is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The adenovirus E4 11 k protein binds and relocalizes the cytoplasmic P-body component Ddx6 to aggresomes

The adenovirus E4 11 k protein, product of E4 ORF3, is required in infection for processes including normal accumulation of viral late mRNAs. 11 k restructures both the nucleus and cytoplasm of infected cells by relocalizing specific host cell target proteins, most strikingly components of nuclear PML oncogenic domains. It is likely that in many cases relocalization inactivates target proteins to produce 11 k's effects, although the mechanism and targets for stimulation of late mRNA accumulation is unknown. We have identified a new set of proteins relocalized by 11 k: at least five protein components of cytoplasmic mRNA processing bodies (p-bodies) are found in 11 k-induced cytoplasmic aggresomes, sites where proteins are inactivated or destroyed. One of these p-body proteins, RNA helicase Ddx6, binds 11 k, suggesting a mechanism for relocalization. Because p-bodies are sites for mRNA degradation, their modification by 11 k may provide an explanation for the role of 11 k in viral late mRNA accumulation.

60 APPLIED LIFE SCIENCES↗