Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BLOOD VESSELS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Investigation of the Hemodynamic Effect of Stent Wires on Renal Arteries in Patients with Abdominal Aortic Aneurysms Treated with Suprarenal Stent-Grafts

The purpose of the study was to investigate the hemodynamic effect of stent struts (wires) on renal arteries in patients with abdominal aortic aneurysms (AAAs) treated with suprarenal stent-grafts. Two sample patients with AAA undergoing multislice CT angiography pre- and postsuprarenal fixation of stent-grafts were selected for inclusion in the study. Eight juxtarenal models focusing on the renal arteries were generated from the multislice CT datasets. Four types of configurations of stent wires crossing the renal artery ostium were simulated in the segmented aorta models: a single wire crossing centrally, a single wire crossing peripherally, a V-shaped wire crossing centrally, and multiple wires crossing peripherally. The blood flow pattern, flow velocity, wall pressure, and wall shear stress at the renal arteries pre- and post-stent-grafting were analyzed and compared using a two-way fluid structure interaction analysis. The stent wire thickness was simulated with a diameter of 0.4, 1.0, and 2.0 mm, and hemodynamic analysis was performed at different cardiac cycles. The interference of stent wires with renal blood flow was mainly determined by the thickness of stent wires and the type of configuration of stent wires crossing the renal ostium. The flow velocity was reduced by 20-30% in most of the situations when the stent wire thickness increased to 1.0 and 2.0 mm. Of the four types of configuration, the single wire crossing centrally resulted in the highest reduction of flow velocity, ranging from 21% to 28.9% among three different wire thicknesses. Wall shear stress was also dependent on the wire thickness, which decreased significantly when the wire thickness reached 1.0 and 2.0 mm. In conclusion, our preliminary study showed that the hemodynamic effect of suprarenal stent wires in patients with AAA treated with suprarenal stent-grafts was determined by the thickness of suprarenal stent wires. Research findings in our study are useful for follow-up of patients treated with suprarenal stent-grafts to ensure long-term safety of the suprarenal fixation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Portal Vein Embolization with Radiolabeled Polyvinyl Alcohol Particles in a Swine Model: Hepatic Distribution and Implications for Pancreatic Islet Cell Transplantation

The distribution of radiolabeled polyvinyl alcohol microspheres (PVAMs) when infused into the portal vein of domestic swine was investigated, with the purpose of assessing implications for pancreatic islet cell transplantation. PVAMs measuring 100-300 {mu}m (Contour SE) and labeled with {sup 99m}Tc were infused into the main portal vein of 12 swine, with intermittent portal venous pressure measurements. The infusion catheter was introduced antegradely via direct or indirect cannulation of the portal vein. The liver was subsequently divided into anatomical segments. Radioactivity (decay corrected) was measured for {sup 99m}Tc microsphere synthesis, dose preparation, gross organ activities, tissue samples, and blood. Particulate labeling, catheter positioning, and infusion were successful in all cases. The number of particles used was (185,000 {+-} 24,000) with a volume of 1 ml. Mean portal pressure at 5 min was significantly higher than baseline, but without a significant difference at 15 min. Extrahepatic tissue and serum radioactivity was negligible. A significant difference in number of radioactive particles per gram was detected between segments 6/7 and segments 5/8. Intrasegmental activity was analyzed, and for segments 2/3 a significant difference in the percentage dose per gram across samples was demonstrated (P = 0.001). Effective and stable radiolabeling of PVAMs with {sup 99m}Tc-sulfur colloid was demonstrated. Portal venous infusion of 100- to 300-{mu}m particles showed entrapment in the sinusoidal hepatic system with transient portal pressure elevation. Preferential embolization into the right lateral and posterior segments occurs, suggesting that flow dynamics/catheter tip position plays a role in particle distribution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Intra-Arterial Chemotherapy and Embolization Before Limb Salvage Surgery for Osteosarcoma of the Lower Extremity

We report our experience with the use of intra-arterial chemotherapy and embolization before limb salvage surgery in patients with osteosarcoma of the lower extremity. We evaluated the effect of this procedure on the degree of tumor necrosis and on the amount of blood loss during surgery. We reviewed the medical records of all patients who received intra-arterial chemotherapy and embolization before undergoing limb salvage surgery for osteosarcoma of the lower extremity at our institution between January 2003 and April 2008. Patient demographic, tumor characteristics, treatment details, postembolization complications, and surgical and pathological findings were recorded for each patient. We evaluated the operative time, estimated blood loss (EBL), and volume of blood transfusion during surgery and in the postoperative period in all patients in the study group. The same parameters were recorded for 65 other patients with lower extremity osteosarcoma who underwent limb salvage operation at our institution without undergoing preoperative intervention. The study included 47 patients (25 males and 22 females). Angiography showed that the tumors were hypervascular. Intra-arterial chemotherapy and embolization were performed successfully, resulting in a substantial reduction or complete disappearance of tumor stain in all patients. No major complications were encountered. At the time of surgery, performed 3-7 days after embolization, a fibrous edematous band around the tumor was observed in 43 of the 47 patients, facilitating surgery. The goal of limb salvage was achieved successfully in all cases. Percentage tumor necrosis induced by treatment ranged from 70.2% to 94.2% (average, 82.9%). EBL during surgery, EBL from drains in the postoperative period, total EBL, and transfusion volumes were significantly lower in the 47 study patients compared to the 65 patients who underwent surgery without preoperative treatment with intra-arterial chemotherapy and embolization. The mean operative time was also significantly less in the intervention group compared to the nonintervention group (73.2 vs. 88.5 min; p < 0.05). In conclusion, intra-arterial chemotherapy and embolization performed 3 to 7 days before limb salvage surgery in patients with lower extremity osteosarcomas can cause substantial tumor necrosis, reduce the EBL and transfusion requirements during surgery, and induce formation of a false capsule around the tumor, thus facilitating surgical excision of the tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Whole-Body Magnetic Resonance Angiography at 3 Tesla Using a Hybrid Protocol in Patients with Peripheral Arterial Disease

The purpose of this study was to determine the diagnostic performance of 3T whole-body magnetic resonance angiography (WB-MRA) using a hybrid protocol in comparison with a standard protocol in patients with peripheral arterial disease (PAD). In 26 consecutive patients with PAD two different protocols were used for WB-MRA: a standard sequential protocol (n = 13) and a hybrid protocol (n = 13). WB-MRA was performed using a gradient echo sequence, body coil for signal reception, and gadoterate meglumine as contrast agent (0.3 mmol/kg body weight). Two blinded observers evaluated all WB-MRA examinations with regard to presence of stenoses, as well as diagnostic quality and degree of venous contamination in each of the four stations used in WB-MRA. Digital subtraction angiography served as the method of reference. Sensitivity for detecting significant arterial disease (luminal narrowing {>=} 50%) using standard-protocol WB-MRA for the two observers was 0.63 (95%CI: 0.51-0.73) and 0.66 (0.58-0.78). Specificities were 0.94 (0.91-0.97) and 0.96 (0.92-0.98), respectively. In the hybrid protocol WB-MRA sensitivities were 0.75 (0.64-0.84) and 0.70 (0.58-0.8), respectively. Specificities were 0.93 (0.88-0.96) and 0.95 (0.91-0.97). Interobserver agreement was good using both the standard and the hybrid protocol, with {kappa} = 0.62 (0.44-0.67) and {kappa} = 0.70 (0.59-0.79), respectively. WB-MRA quality scores were significantly higher in the lower leg using the hybrid protocol compared to standard protocol (p = 0.003 and p = 0.03, observers 1 and 2). Distal venous contamination scores were significantly lower with the hybrid protocol (p = 0.02 and p = 0.01, observers 1 and 2). In conclusion, hybrid-protocol WB-MRA shows a better diagnostic performance than standard protocol WB-MRA at 3 T in patients with PAD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrieval of Cement Embolus from Inferior Vena Cava After Percutaneous Vertebroplasty

Percutaneous vertebroplasty is an accepted treatment for painful vertebral compression fractures caused by osteoporosis and malignant disease. Venous leakage of cement and pulmonary cement embolism have been reported complications. We describe a paravertebral venous cement leak resulting in the deposition of a cement cast in the inferior vena cava and successful retrieval of the cement embolus.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bifurcated Endograft (Excluder) in the Treatment of Isolated Iliac Artery Aneurysm: Preliminary Report

The aim of this study was to evaluate the effectiveness of endovascular repair in the treatment of isolated iliac artery aneurysm (IAA) using Excluder bifurcated endograft. Eight consecutive patients with IAA were treated during a period of 45 months using Excluder bifurcated endograft. Two patients presented with isolated IAA rupture and were treated emergently, whereas the other six patients underwent elective treatment. All aneurysms lacked sufficient proximal necks and therefore were not suitable for tubular-shaped endograft. Follow-up imaging was performed at 1 week, at every 3 months during the first year, semiannually until 2 years, and annually afterward using angio-computed axial tomography and plain films. Technical success was achieved in all patients. No mortality was seen despite two patients having IAA rupture. Follow-up (12 to 60 months) was done in all but one patient. During this period, complications were observed in three patients. One patient developed sexual impotence at 3-month follow up; one patient presented unilateral gluteal claudication after the procedure, which resolved at 3 months; and one patient developed a graft porosity-related endoleak, which was successfully managed with placement of an additional ipsilateral iliac extension. Endovascular treatment of isolated IAA using bifurcated endograft is safe and can be an alternative to surgical treatment. The benefits from decreased morbidity and mortality of endoluminal treatment of isolated IAA using bifurcated endograft outweigh the minor complications associated with this technique, which are mostly related to occlusion of hypogastric arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory Displacement of the Thoracic Aorta: Physiological Phenomenon With Potential Implications for Thoracic Endovascular Repair

The purpose of this study was to assess the magnitude and direction of respiratory displacement of the ascending and descending thoracic aorta during breathing maneuvers. In 11 healthy nonsmokers, dynamic magnetic resonance imaging was performed in transverse orientation at the tracheal bifurcation during maximum expiration and inspiration as well as tidal breathing. The magnitude and direction of aortic displacement was determined relatively to resting respiratory position for the ascending (AA) and descending (DA) aorta. To estimate a respiratory threshold for occurrence of distinct respiratory aortic motion, the latter was related to the underlying change in anterior-posterior thorax diameter. Compound displacement between maximum expiration and inspiration was 24.3 {+-} 6.0 mm for the AA in the left anterior direction and 18.2 {+-} 5.5 mm for the DA in the right anterior direction. The mean respiratory thorax excursion during tidal breathing was 8.9 {+-} 2.8 mm. The respiratory threshold, i.e., the increase in thorax diameter necessary to result in respiratory aortic displacement, was estimated to be 15.7 mm. The data suggest that after a threshold of respiratory thorax excursion is exceeded, respiration is accompanied by significant displacement of the thoracic aorta. Although this threshold may not be reached during tidal breathing in the majority of individuals, segmental differences during forced respiration impact on aortic geometry, may result in additional extrinsic forces on the aortic wall, and may be of significance for aortic prostheses designed for thoracic endovascular aortic repair.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Telemetric Catheter-Based Pressure Sensor for Hemodynamic Monitoring: Experimental Experience

The purpose of this study was to evaluate the technical and animal experimental feasibility of a percutaneously implantable pulmonary arterial implant for permanent hemodynamic monitoring. Two systems for measuring pulmonary artery pressure (PAP) as well as pulmonary artery occlusion pressure (PAOP) were developed by modifying a commercially available pulmonary artery catheter (PAC). First, a cable-bound catheter-based system was designed by implementation of a capacitive absolute-pressure sensor in the catheter tip. This system was developed further into a completely implantable telemetric system. The devices were tested in an acute setting in a total of 10 sheep. The implant was placed with its tip in the descending pulmonary artery via the right jugular approach. Results were compared with conventional PAC positioned in the contralateral pulmonary artery using Pearson's correlation coefficients and Bland-Altman plots. Implantation of the monitoring systems was uneventful in 10 animals. Data from two fully functional cable-bound and telemetric pressure monitoring systems were available, with a total of 18,506 measurements. There was an excellent correlation between reference data and the data obtained with the implants (r = 0.9944). Bland-Altman plots indicated a very good agreement between the techniques. We report the development and successful initial test of an implantable catheter-based device for long-term measurement of PAP and PAOP. Both devices may be applicable for hemodynamic monitoring. Further long-term studies for assessing reliability and durability of the device are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Therapeutic Approaches for Acute Superior Mesenteric Artery Occlusion

The purpose of this study was to characterize the outcome of attempted endovascular intervention in patients with acute embolic or thrombotic superior mesenteric artery (SMA) occlusion. The records of 21 patients during a 3-year period between 2005 and 2008 were retrieved from the in-hospital registry. The first group included 10 patients (6 women and 4 men; median age 78 years) with acute embolic occlusion of the SMA. The median duration of symptoms from symptom onset to angiography was 30 hours (range 6 to 120). Synchronous emboli (n = 12) occurred in 6 patients. Embolus aspiration was performed in 9 patients, and 7 of these had satisfactory results. Complementary local thrombolysis was successful in 2 of 3 patients. Residual emboli were present at completion angiography in all 7 patients who underwent successful aspiration embolectomy, and bowel resection was necessary in only 1 of these patients. One serious complication occurred because of a long SMA dissection. The in-hospital survival rate was 90% (9 of 10 patients). The second group included 11 patients (10 women and 1 man; median age 68 years) with atherosclerotic acute SMA occlusions. The median time of symptom duration before intervention was 97 hours (range 17 to 384). The brachial, femoral, and SMA routes were used in 6, 7, and 5 patients, respectively. SMA stenting was performed through an antegrade (n = 7) or retrograde (n = 3) approach. Bowel resection was necessary in 4 patients. No major complications occurred. The in-hospital survival rate was 82% (9 of 11 patients). Endovascular therapy of acute SMA occlusion provides a good alternative to open surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Systemic Hypertension and Transient Ischemic Attack in a 6-Year-Old Girl with Fibromuscular Dysplasia Treated with Percutaneous Angioplasty

We describe a 6-year-old girl with arterial hypertension secondary to fibromuscular dysplasia with stenoses of both renal arteries and transient ischemic attack due to extracranial right internal carotid artery subtotal occlusion as well as left internal carotid artery stenosis. She was treated with percutaneous angioplasty of both renal and both carotid arteries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Hemoptysis from Pulmonary Artery Pseudoaneurysm Caused by Lung Radiofrequency Ablation: Successful Treatment by Coil Embolization

A 75-year-old man received lung radiofrequency (RF) ablation to treat lung metastases from hepatocellular carcinoma. Massive hemoptysis occurred 1 week after lung RF ablation. Emergent contrast-enhanced CT and pulmonary arteriography revealed a pulmonary artery pseudoaneurysm, which was embolized with coils. The postembolization course was uneventful. Hemoptysis did not recur for 5 months.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Artery Pseudoaneurysm Related to Radiofrequency Ablation of Lung Tumor

We describe a case of pulmonary artery (PA) pseudoaneurysm related to radiofrequency ablation (RFA) of lung tumor. We performed RFA for a pulmonary epithelioid hemangioendothelioma directly adjacent to a branch of the PA. Seventeen days later, the patient complained of hemoptysis. A chest CT image revealed PA pseudoaneurysm. Transcatheter coil embolization was performed 59 days after RFA. Although PA pseudoaneurysm is rare, with an incidence of 0.2% (1/538 sessions) at our institution, it should be recognized as a risk when treating lung tumors adjacent to a branch of the PA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Nontarget Embolization Mechanisms During Embolization and Chemoembolization Procedures

Complications of embolization and chemoembolization remain a problem even with the development of low-profile catheter material and the introduction of new embolization agents. In recent years many new embolization materials have become available for clinical use, so the possibilities and limitations of these new materials must be understood to allow safe and effective embolization. Although up to now some scientific work has been published reporting the basic risk of embolization procedures, the underlying pathomechanism remains the object of speculation. Besides complications like drug toxicity, allergic reactions, and bleeding of the puncture site, the characteristics of embolization materials must be known to understand the potential complications of nontarget embolization and reflux of embolization material. This article gives an overview of established and new embolization materials, their potential risks, and the underlying pathophysiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Transarterial Infusion Chemotherapy Using Cisplatin-Lipiodol Suspension With or Without Embolization for Unresectable Hepatocellular Carcinoma

We evaluate the long-term prognosis and prognostic factors in patients treated with transarterial infusion chemotherapy using cisplatin-lipiodol (CDDP/LPD) suspension with or without embolization for unresectable hepatocellular carcinoma (HCC). Study subjects were 107 patients with HCC treated with repeated transarterial infusion chemotherapy alone using CDDP/LPD (adjusted as CDDP 10mg/LPD 1ml). The median number of transarterial infusion procedures was two (range, one to nine), the mean dose of CDDP per transarterial infusion chemotherapy session was 30 mg (range, 5.0-67.5 mg), and the median total dose of transarterial infusion chemotherapy per patient was 60 mg (range, 10-390 mg). Survival rates were 86% at 1 year, 40% at 3 years, 20% at 5 years, and 16% at 7 years. For patients with >90% LPD accumulation after the first transarterial infusion chemotherapy, rates were 98% at 1 year, 60% at 3 years, and 22% at 5 years. Multivariate analysis identified >90% LPD accumulation after the first transarterial infusion chemotherapy (p = 0.001), absence of portal vein tumor thrombosis (PVTT; p < 0.001), and Child-Pugh class A (p = 0.012) as independent determinants of survival. Anaphylactic shock was observed in two patients, at the fifth transarterial infusion chemotherapy session in one and the ninth in the other. In conclusion, transarterial infusion chemotherapy with CDDP/LPD appears to be a useful treatment option for patients with unresectable HCC without PVTT and in Child-Pugh class A. LPD accumulation after the first transarterial infusion chemotherapy is an important prognostic factor. Careful consideration should be given to the possibility of anaphylactic shock upon repeat infusion with CDDP/LPD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Circumflex Iliac Artery-Related Hemoperitoneum Formation After Surgical Drain Placement: Successful Transcatheter Embolization

A 53-year-old woman with liver cirrhosis and hepatocellular carcinoma underwent living donor liver transplantation. After transplantation, her hemoglobin and hematocrit levels decreased to 6.3 g/dl and 18.5%, respectively, during the course of 3 days. A contrast-enhanced abdominal computed axial tomography (CAT) scan showed a hemoperitoneum in the right perihepatic space with no evidence of abdominal wall hematoma or pseudoaneurysm formation. An angiogram of the deep circumflex iliac artery (DCIA) showed extravasation of contrast media along the surgical drain, which had been inserted during the transplantation procedure. Transcatheter embolization of the branches of the DCIA was successfully performed using N-butyl cyanoacrylate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of Uterine Arteriovenous Malformations Associated with Cyanotic Congenital Heart Disease

Uterine arteriovenous malformation (AVM) is a rare cause of vaginal bleeding and miscarriage. We report two cases of uterine AVMs in patients with a history of complex congenital heart disease, an association that has not been previously described. Both patients were treated by selective uterine artery embolization, a minimally invasive therapy that has revolutionized the management of uterine AVMs, thus offering an alternative to conventional hysterectomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗