Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BEAM MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Real-Time Inference For MI/RR Deblending

The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.

Yu, Kellen [Cornell U.]↗

Collimation and tagging instrumentation for the GlueX Photon Beamline

A new high energy polarized photon source is being constructed for the GlueX experiment at Jefferson Lab. Linear polarization is obtained using coherent bremsstrahlung from an oriented diamond radiator. By collimating the photon beam to a fraction of the characteristic bremsstrahlung angle $m_e/E_0$, linear polarization of 40\% is obtained at a photon energy of 9~GeV, for an incident electron beam of 12~GeV. Active stabilization of the photon beam spot on the collimator face is required in order to establish and maintain the alignment of the beam on the collimator axis with the required degree of accuracy. A photon beam centroid monitor has been developed for this purpose, based on the design of an electron beam halo detector that was invented for use at SLAC 30 years ago. Beam tests of this device in Hall B at 6 GeV show that it has the required bandwidth and sensitivity to be used in an active feedback loop in the electron beam steering controls. Such a feedback circuit is capable of locking the Hall D photon beam on the Hall D collimator with the required accuracy for GlueX at frequencies up to 1~kHz, over a wide range in beam current.

Jones, Richard↗

Exploration of Real Time Inference for MI-RR Deblending on GPU/TPU Systems

The Fermilab Main Injector (MI) and Recycler Ring (RR) share a common beam loss monitor (BLM) system, making loss events difficult to attribute to their source machine when beam is present in both simultaneously. The Real-time Edge AI for Distributed Systems (READS) project addresses this by deblending BLM readings in real time using machine learning (ML). The current FPGA based implementation meets the sub-3 ms latency requirement but carries a resource intensive hls4ml development cycle, motivating exploration of GPU based deployment. This paper characterizes inference latency on an NVIDIA Jetson Orin Nano and introduces a packet organization scheme for assembling synchronized event frames from seven distributed BLM DAQ streams. Using a Python based DAQ simulation with injected timing jitter in place of unavailable live beam data, the pipeline achieved an average end to end latency of 0.456 ms (σ = 0.122 ms) across 167,000 test frames, comfortably meeting the timing constraint. Early outliers were attributed to TensorRT warm-up rather than steady state limitations, suggesting GPU based inference is a viable alternative to the existing FPGA implementation.

Yu, Kellen [Fermilab; Cornell U.]↗

Measurements of the Propagation of EM Waves through the Vacuum Chamber of the PEP-II Low Energy Ring for Beam Diagnostics

We present the results of our measurements of the electron cloud density in the PEP-II low energy ring (LER) by propagating a TE wave into the beam pipe. By connecting a signal generator to a beam position monitor button we can excite a signal above the vacuum chamber cut-off frequency and measure its propagation through the beam pipe with a spectrum analyzer connected to another button about 50 meters away. The measurement can be performed with different beam conditions and also at different settings of the solenoids used to reduce the build up of electrons. The presence of a modulation in the TE wave transmission, synchronous with the beam revolution frequency, which appear to increase in depth when the solenoids are switched off, seem to be directly correlated to the electron cloud density in the region between the two BPM's. In this paper we present and discuss the measurements taken in the Interaction Region 12 straight of the LER during 2006 and the first part of 2007.

43 PARTICLE ACCELERATORS↗

Measurement and analysis of fast transient instabilities

In this study, a novel beam diagnostics technique to detect fast beam transient instabilities and glitches has been developed at National Synchrotron Light Source II (NSLS-II). Vertical spikes of beam size and centroid have been observed occasionally and randomly during high current operations. These spikes are believed to be caused by ion instabilities associated with vacuum activity localized in the ring. With the functionality of gated beam position monitor (BPM), the newly developed technique utilizes turn-by-turn (TBT) data to detect beam centroid glitches. Whenever one turn trajectory deviates from a predefined window, a global control event is generated to trigger an online TBT data acquisition. The data acquisition is synchronized for all BPMs around the ring. In the meantime, the bunch-by-bunch (BxB) data, which is acquired from a single dedicated feedback BPM, has also been collected for analyzing possible coupled bunch instabilities (CBI). In addition to CBI caused mainly by ion bursts, other types of fast transient motions, such as, the top-off residual disturbance and fast orbit disturbance, have been captured with the new tool. Lastly, the sources of the glitches can be approximately localized with the synchronized TBT data from multiple BPMs around the ring.

43 PARTICLE ACCELERATORS↗

Machine-Protection System for the PIP-II Linear Accelerator: Architecture and Data Processing Schemes

PIP-II at Fermilab features a brand-new, 800 MeV leading-edge Linear Accelerator (Linac) that will enable the Fermilab complex to deliver more than a megawatt of beam power to the Long Base-line Neutrino Facility (LBNF), requiring a robust Machine Protection System (MPS) to prevent beam-induced damage to delicate cryomodules and vacuum components. Signals in various accelerator components, in both analog and digital format, are collected and processed to assest the operating conditions of the accelerator. In the situation a potential damage is foreseen, the beam permit signal will be drop. A critical element of this system is the fast Analog Machine Protection System, a high-bandwidth platform designed for real-time beam loss monitoring. The system utilizes a modular, FPGA-based architecture to digitize signals from beam-sensing devices, such as AC Current Transformers (ACCTs), non-invasive Ring Pickups (RPUs) and beam scrapers. To eliminate both high frequency as well as 60 Hz noise that might be picked up in the industrial environment, data processing schemes beyond regular digital filtering are planned and implemented.

Wu, Jinyuan [Fermilab] (ORCID:0000000344329521)↗

SU-F-T-237: The Imaging and Radiation Oncology Core (IROC) Cooperatives Activities Supporting the NCI’s National Clinical Trial Network

Purpose: The Imaging and Radiation Oncology Core (IROC) Cooperative has been active for the past two years supporting the National Clinical Trial Network and the details of that support are reported. Methods: There are six QA centers (Houston, Ohio, Philadelphia-RT, Philadelphia-DI, Rhode Island, St. Louis) providing an integrated RT and DI quality control program in support of the NCI’s clinical trials. The QA Center’s efforts are focused on assuring high quality data for clinical trials designed to improve the clinical outcomes for cancer patients worldwide. This program is administered through five core services: site qualification, trial design support, credentialing, data management, and case review. Results: IROC currently provides core support for 172 NCTN trials with RT, DI and RT/DI components. Many of these trials were legacy trial from the previous cooperative group program. IROC monitors nearly 1800 RT photon and 20 proton institutions. Over 28,000 beams outputs were monitored with 8% of the sites requiring repeat audits due to beam out of criteria. As part of credentialing, 950 QA phantoms have been irradiated, 515 imaging modalities evaluated and almost 4000 credentialing letters have been issued. In just year 2, 5290 RT and 4934 DI patient datasets were received (many using TRIAD) by IROC QA Centers to be prepared for review. During the past 2 years, a total of 6300 RT cases and 19,000 DI image sets were reviewed by IROC technical staff. To date, IROC has published 36 manuscripts. Conclusion: The QA services provided by IROC are numerous and are continually being evaluated for effectiveness, harmonized across all NCTN Groups and administered in an efficient and timely manner to enhance accurate and per protocol trial data submission. These efforts increase each NCTN Group’s ability to derive meaningful outcomes from their clinical trials. This work was supported by DHHS NIH grant 5U24CA180803.

60 APPLIED LIFE SCIENCES↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

Deuteron EDM Polarimetry

Following an introduction to the physics motivation for the search for an intrinsic electric dipole moment, the possibility of developing a storage ring search using a polarized deuteron beam is reviewed. Such a search involves continuous monitoring of the deuteron beam polarization during the beam store. Polarimeter concepts for this project are developed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The beam diagnostic instruments in Beijing radioactive ion-beam facilities isotope separator on-line

The beam diagnostic instruments for Beijing Radioactive Ion-beam Facilities Isotope Separator On-Line are introduced [B. Q. Cui, Z. H. Peng, Y. J. Ma, R. G. Ma, B. Tang, T. Zhang, and W. S. Jiang, Nucl. Instrum. Methods 266, 4113 (2008); T. J. Zhang, X. L. Guan, and B. Q. Cui, in Proceedings of APAC 2004, Gyeongju, Korea, 2004, http://www.jacow.org , p. 267]. For low intensity ion beam [30–300 keV/1 pA–10 μA], the beam profile monitor, the emittance measurement unit, and the analyzing slit will be installed. For the primary proton beam [100 MeV/200 μA], the beam profile scanner will be installed. For identification of the nuclide, a beam identification unit will be installed. The details of prototype of the beam diagnostic units and some experiment results will be described in this article.

43 PARTICLE ACCELERATORS↗

Ion beam emittance from an ECRIS

Simulation of ion beam extraction from an Electron Cyclotron Resonance Ion Source (ECRIS) is a fully 3 dimensional problem, even if the extraction geometry has cylindrical symmetry. Because of the strong magnetic flux density, not only the electrons are magnetized but also the Larmor radius of ions is much smaller than the geometrical dimension of the plasma chamber (Ø 64 × 179 mm). If we assume that the influence of collisions is small on the path of particles, we can do particle tracking through the plasma if the initial coordinates of particles are known. We generated starting coordinates of plasma ions by simulation of the plasma electrons, accelerated stochastically by the 14.5 GHz radio frequency power fed to the plasma. With that we were able to investigate the influence of different electron energies on the extracted beam. Using these assumptions, we can reproduce the experimental results obtained 10 years ago, where we monitored the beam profile with the help of viewing targets. Additionally, methods have been developed to investigate arbitrary 2D cuts of the 6D phase space. To this date, we are able to discuss full 4D information. Currently, we extend our analysis tool towards 5D and 6D, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-636: ProteusONE Machine QA Procedure and Stabiity Study: Half Year Clinical Operation

Purpose: The objective of this study is to evaluate the stability of ProteusOne, the 1st commercial PBS proton system, throughout the daily QA and monthly over 6 month clinical operation. Method: Daily QA test includes IGRT position/repositioning, output in the middle of SOBP, beam flatness, symmetry, inplane and crossplane dimensions as well as energy range check. Daily range shifter QA consist of output, symmetry and field size checks to make sure its integrity. In 30 mins Daily QA test, all the measurements are performed using the MatriXXPT (IBA dosimetry). The data from these measurement was collected and compare over the first 6 month of clinical operation. In addition to the items check in daily QA, the summary also includes the monthly QA gantry star shots, absolute position check using a novel device, XRV-100. Results: Average machine output at the center of the spread out bragg peak was 197.5±.8 cGy and was within 1%of the baseline at 198.4 cGy. Beam flatness was within 1% cross plane with an average of 0.67±0.12% and 2% in-plane with an average of 1.08±0.17% compared to baseline measurements of 0.6 and 1.03, respectively. In all cases the radiation isocenter shift was less than or equal to 1mm. Output for the range shifter was within 2% for each individual measurement and averaged 34.4±.2cGy compare to a baseline reading of 34.5cGy. The average range shifter in and cross plane field size measurements were 19.8±0.5cm and 20.5±0.4cm compared with baseline values of 20.19cm and 20.79cm, respectively. Range shifter field symmetry had an average of less 1% for both in-plane and cross plane measurements. Conclusion: All machine metrics over the past 6 months have proved to be stable. Although, some averages are outside the baseline measurement they are within 1% tolerance and the deviation across all measurements is minimal.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of delta ray electrons on measurement uncertainties of harp system

A harp system, which is a multi-wire beam profile monitoring (MWPM) system, is planned upstream of the spallation target to make in situ calibration of beam current density configuration on the target along with beam imaging from luminescent coating on the beam entrance window at the Second Target Station (STS) of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). This beam interception-based beam diagnostics system on the target will be used to ensure that the maximum beam loads on the target are within the design range during neutron production. Current design of the harp consists of three layers of measurement wires each of which is sandwiched between voltage biasing wire planes. The signal obtained from each measurement wire layer is disturbed by secondary electrons (SE) and delta rays produced by beam-matter interactions in neighboring wires and ionization of residual gases in accelerator vacuum. While the backgrounds from SE can be suppressed by voltage biasing, the delta-ray electrons with kinetic energies above keV ranges overcome the electric potential bias. In this paper, we study the effects of delta-rays on the measurement uncertainties of MWPM using the particle transport simulation code FLUKA. Furthermore, the cases where the harp system is installed in the proximity of a large delta ray sources such as proton beam window or in the core vessel filled with sub-atmospheric gas have been studied.

Lee, Yong Joong↗

Results From the 6D Diagnostics Test Bench at SNS

This paper presents the method and results for measuring the full six-dimensional phase space of a low energy, high intensity hadron beam. This was done by combining four-dimensional emittance measurement techniques along with dispersion measurement and a beam shape monitor to provide the energy and arrival time components. The measurements were performed on the new Beam Test Facility (BTF) at the Spallation Neutron Source (SNS), a 2.5 MeV functional duplicate of the SNS accelerator front end. The results include a correlation the had not previously been observed.

Cathey, Brandon↗

SNS BLM SYSTEM EVOLUTION: DETECTORS, ELECTRONICS AND SOFTWARE

SNS is a high intensity hadron beam facility; so the Beam Loss Monitor (BLM) system is a crucial part of Machine Protection System and an important tool for beam tuning. The paper presents the current status of installed detectors and experimental data obtained during SNS operations. We compare several different types of BLMs and show advantages and disadvantages of each type. The electronic parts obsolescence became a real issue since the original electronics was designed about 10 years ago. The first test of our next generation BLM system is expected to be done by summer 2009. The new system will contribute to significant noise reduction and will follow a modular concept of Smart Device to achieve a higher degree of reliability and maintainability.

Zhukov, Alexander P↗

6D Phase Space Measurement of Low Energy, High Intensity Hadron Beam

The goal of this project is to demonstrate a method for measuring the full six dimensional phase space of a low energy, high intensity hadron beam. This is done by combining four dimensional emittance measurement techniques along with dispersion measurement and a beam shape monitor to provide the energy and arrival time components. The measurements are performed on the new Beam Test Facility (BTF) at the Spallation Neutron Source (SNS), a 2.5 MeV functional duplicate of the SNS accelerator front end.

Cathey, Brandon L.↗

6D Phase Space Measurement of Low Energy, High Intensity Hadron Beam

The goal of this project is to demonstrate a method for measuring the full 6D phase space of an low energy, high intensity hadron beam. This is done by combining 4D emittance measurement techniques along with dispersion measurement and a beam shape monitor to provide the energy and phase space components. The measurement will be performed on new Beam Testing Facility (BTF) at the Spallation Neutron Source (SNS), a 2.5 MeV functional duplicate of the SNS accelerator front end.

Cathey, Brandon↗

Reflection high-energy electron diffraction phi scans for in situ monitoring the heteroepitaxial growth of Fe on GaN(0001) by molecular beam epitaxy

The heteroepitaxial growth of Fe films on GaN(0001) by molecular beam epitaxy is monitored in situ by reflection high-energy electron diffraction phi scans. The complex epitaxial orientation-relationship between Fe and GaN can be visualized by these phi scans already at an Fe coverage of two monolayers. By comparing the data to ex situ x-ray phi scans, we show that these measurements even allow a quantitative determination of the in-plane orientation-distribution of the heteroepitaxial film. The orientation-distribution is minimized for a growth temperature of 350 deg. C.

36 MATERIALS SCIENCE↗