Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Averages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Low-Cost, High-Performance Carbon Fiber for Compressed Natural Gas Storage Tanks (Final Technical Report – Down Select Report)

The aim of this project is to reduce the cost of Type IV, carbon fiber (CF) composite overwrap compressed gas storage tanks by reducing the cost of CF and CF composites. The project team worked to reduce the cost of CF by exploring and testing opportunities for a low-cost alternative precursor material for CF production to supplant market-dominant and costly polyacrylonitrile (PAN). Concurrently, the team aimed to reduce the cost of the tanks at the composite level by improving the interfacial adhesion between the fibers and the matrix resin through the incorporation of low-cost nanoparticles recycled from waste materials, which would reduce the volume of costly CF required to achieve the same tank performance. At the end of the first year, the project team selected mesophase pitch as the primary precursor candidate from a field of materials based on the superior mechanical performance and cost-saving potential. During the second year, the team produced CFs derived from mesophase pitch achieving an average tensile strength of 365.6 ksi and average tensile modulus of 40.74 Msi. Facility availability for spinning and converting these fibers at greater scale has hindered scale-up demonstration, but the team has identified opportunities to conduct this work in the near term. Cost modeling shows that these mesophase pitch-derived CFs can be up to 40% less expensive than PAN-derived CFs due to the lower cost of the feedstock material, higher throughput, greater conversion yield, and lower cost spinning method and compared to PAN. Additionally, the team has demonstrated at lab-scale that nanoparticle coating CFs can significantly increase the interfacial shear strength and load transfer efficiency of CFs in a matrix. Single filament pull-out testing showed a 27% average increase in max interfacial shear strength due to this coating. A continuous method of applying these coatings to a tow of CF has been developed for scale-up. 26 m tows of coated CFs were produced using this system and formed into composite ring samples for ASTM ring burst testing. Issues with the testing protocol have limited assessment of these results. A prototype Type IV tank was designed to meet ANSI HGV2 standards, and the design criteria set out by DOE, using the CF properties developed by the team paired with a proprietary resin matrix, a polyamide liner, and aluminum end bosses. The tank weighs 153.1 kg and with a total capacity of 5.8 kg H2 (5.6 kg usable), which yields a gravimetric capacity of 1.17 kWh/kg. Cost modeling predicts that the tank will have a projected cost of $15.73/kWh. Tank performance modeling does not include considerations for fiber-matrix load transfer efficiency improvements offered by nanoparticle coating method.

08 HYDROGEN↗

Turbulent Processes that Influence Boundary-Layer Cloud Structure (Final Technical Report)

Many models of the atmosphere simulate vertical profiles of observable fields, such as temperature, moisture, and vertical velocity. To assess the realism of such model output, it is important to evaluate the modeled profiles against observations. However, many extant evaluations consist of comparing time averaged profiles from the model and the observations. Such time averages can smooth out unrealistic features that appear in instantaneous profiles. In this way, the time averages may obscure certain model errors from detection. For instance, many models misrepresent turbulent processes, leading to profiles that are too smoothed out or too noisy. E.g., if a model has coarse vertical resolution and overly strong diffusion, then the model may be unable to produce observed sharp peaks. On the other hand, a model may have artificial approximations that produce spurious jumps in the vertical. Much can be learned by browsing through instantaneous snapshots of model output. But the volume of output produced by a global model is far too great to rely purely on visual inspection. In addition, we need a way to statistically characterize the profiles, so that anomalies can be detected more conveniently.

54 ENVIRONMENTAL SCIENCES↗

Hydraulic Testing of the Lost Lake Aquifer Near Recovery Well RWM001R

An aquifer pumping test was conducted on the Lost Lake Aquifer Zone (LLAZ) at the recently installed recovery well RWM001R in accordance with the approved test plan (Dixon, 2024). The objective of the testing was to determine baseline well performance parameters and aquifer hydraulic conductivity. This testing consisted of two step-drawdown tests to determine well performance properties and two constant pumping rate aquifer tests with recovery periods to determine aquifer hydraulic properties. Well performance parameters determined included specific capacity, well efficiency, and head loss coefficients. The results of the step-drawdown testing are presented in Tables ES1 and ES2 whereas the results of the constant pumping rate testing are presented in Table ES3. The average specific capacity of RWM001R operating at pump capacity (~54 gpm) was 2.2 gpm/ft using data from the final step of both tests. The average well efficiency determined from both step-drawdown tests was 56% using data from the final step of both tests. For both step-drawdown tests, well efficiency was inversely related to the pumping rate with the average efficiency decreasing from approximately 79% to 56%. Aquifer head loss coefficients from both tests were comparable (Table ES2).

54 ENVIRONMENTAL SCIENCES↗

FY24 Task 5: Leachate Disposition

Directly feeding sludge solids to the high-level waste (HLW) Waste Treatment Plant represents an alternative flowsheet seeking to initiate sludge processing as soon as possible. Key processing functions previously captured during baseline pretreatment operations include leaching and washing prior to solids concentration. These operations should be considered in the potential direct feed flowsheets to maximize waste feed loading, minimize HLW volume, and mitigate corrosion challenges associated with vitrification of high phosphate and fluoride concentrations. Additionally, single-shell tank (SST) retrievals and waste transfers to double-shell tanks (DSTs) in a direct feed flowsheet would likely also benefit from some level of leaching, washing, and solids concentration in order to reduce DST space and mission duration. These operations could occur in a new facility or potentially in available DSTs. If washing and leaching are utilized, an effective disposition pathway for the wash water and leachate solutions are needed. Three target species that benefit significantly from leaching and washing are phosphate, fluoride and aluminum. Phosphate (PO 4 3- ) and fluoride (F - ) can contribute substantially to the amount of carrier fluid needed for dissolution, and the resulting volume of liquid generated. Disposition of this retrieval solution should be evaluated in order to prevent crystallization of these anions throughout system processing. Since there is a high probability that any retrieval solutions will be at or near their PO 4 3- and F - solubility limits, evaporation or blending with a high Na supernate (>3.5 M) is not recommended for the wash water streams without a method to remove precipitants prior to solution disposal. Additionally, aluminum present in the southeast quadrant of the Hanford site represents roughly 60% of the waste solids in the initial processing tanks. These aluminum solids are in the form of gibbsite (Al(OH) 3 ) and can pose significant challenges for processing due to the fast-settling times and high solids loading associated with these materials. Easily remediated by caustic addition to the solids, these wash solutions could be processed through crystalline silicotitanate (CST) ion exchange columns to prepare the supernate solutions for disposition. The current target for feed conditions to the Low Activity Waste (LAW) melter are waste streams that contain nominally 5-6 M Na. Fractions within the tanks contain upwards of 0.2 M phosphate and fluoride in solution at 3.5 M Na. Concentrating these solutions above 5 M Na would result in an exceedance of the solubility limits, and potential for uncontrolled precipitation of the phosphate and fluoride crystal material. The resulting crystalline salt material is typically sodium fluoride phosphate, also referred to as natrophosphate (Na 7 FPO 4 ·19H 2 O). Salt phases are of importance in tank waste due to their chemical reactivity, which can result in precipitation, dissolution, or transformation, impacting any downstream processes (Bolling et al. 2020, Russell, Snow, and Peterson 2010). Salt generation and precipitation could pose challenges by causing system plugging and melter corrosion if left in the supernate stream, or limit sodium molarity of the supernate that would be accepted without incident in waste operations. To understand the impact of this salt generation, the crystallization of natrophosphate in multiple simulant feed matrices was studied to understand the implications of various tank waste supernate chemistries. Three matrices were examined: high PO 4 3- /low F - , low PO 4 3- /high F - , and an average matrix. Subsequent testing was performed with the average matrix with the inclusion of CsNO 3 , and a final run with the average matrix including CsNO 3 and a 137 Cs spike for tracer purposes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Southern Ocean Aerosols Field Campaign Report

Atmospheric processes over the Southern Ocean have a profound influence on regional and global climate. This is a part of the world where global climate models perform particularly poorly, with models persistently overpredicting the amount of sunlight reaching the Earth's surface (Regayre et al. 2020). A major challenge when trying to improve the representation of atmospheric processes in this part of the globe is the scarcity of observations capable of constraining our understanding. During 2024/25 a U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility field campaign (CAPE-k) deployed a suite of instrumentation at the kennaook/Cape Grim atmospheric monitoring station in Tasmania, Australia to provide detailed cloud-aerosol observations in this region in order to address the greatest source of uncertainty in climate models – atmospheric aerosols and how they influence cloud formation (Carslaw et al. 2013). In support of the ARM observations, an Australian Research Council (ARC)-funded project “Southern Ocean aerosols: sources, sinks and impact on cloud properties,” led by the Queensland University of Technology, complemented the ARM measurements with a suite of chemical measurements at the kennaook/Cape Grim site in northwestern Tasmania to provide more information on the processes controlling aerosol formation and growth. The deployment of the University of York LIF-SO2 instrument (Temple et al. 2025) in the ARM mobile facility container was part of this chemistry-focused deployment. Increased observational efforts are critical for understanding sources and sinks of Southern Ocean aerosols, in particular the role of marine micro-organisms (phytoplankton, algae) on aerosols formation, their properties and growth, cloud droplet formation, and the conversion of cloud droplets to ice crystals and precipitation. The observational focus of the ARC-funded project is aerosol chemical composition and their gaseous precursors. The remote nature of the Southern Ocean poses a significant analytical challenge when studying gaseous precursors, as low concentrations are often below the limits of detection of commercial instrumentation. Historically this has meant that observations have had to be time-averaged over days to weeks to achieve the limits of detection required. Although useful when considering overall average levels of aerosol precursors, this time-averaging obscures temporal variability that can provide insight into the controlling processes. Over recent years advances in analytical techniques have made high-time-resolution measurements of key gas-phase aerosol precursors achievable with sufficiently low limits of detection.

54 ENVIRONMENTAL SCIENCES↗

Ultrasonic Characterization of Lithium Ion Thermal Runaway Conditions for Real-time Ultrasonic Enabled BMS Integration

The demand for energy storage is growing, and lithium-ion batteries are a promising technology to meet this need due to their high power/energy density, high round-trip efficiency, rapid response time, and portability. However, recent catastrophic events caused by thermal runaway have slowed their adoption, highlighting the need for an early warning system for battery failure. In this work, ultrasound is used to detect physical changes in 950 mAh batteries by identifying material property changes independent of voltage and current. [Ultrasound signal features (e.g., time of flight, maximum frequency component) were extracted as the batteries were cycled and subjected to both constant current and constant voltage overcharge and were used to develop two metrics identifying failure: a warning to detect the start of overcharge and an emergency stop (E-stop) to immediately take the battery out of service. The identification method involved locating magnitude differences of several ultrasound features compared to baseline operation considering different currents and temperatures, and the warning/stopping metrics were consistent across all experiments. For an average overcharge time of 140 minutes, the average warning was issued 124 minutes before the failure and the average E-stop was triggered 94 minutes before failure. As a test of using ultrasound for early warning detection, a battery was forced into overcharge and returned to normal cycling conditions based on the previously determined warning metric. Both the voltage profile and the ultrasound measurements returned to their baseline behavior, indicating that ultrasonic detection can not only identify battery failure before a catastrophic event, but can also provide early enough warnings such that overcharges can be detected and corrected quickly enough so the battery does not need to be decommissioned.]

25 ENERGY STORAGE↗

Electrify Monterey Bay

The Electrify Monterey Bay project, delivered by Central Coast Energy Services (CCES) under DOE Weatherization Assistance Program Enhancement & Innovation (E&I) funding, was designed to demonstrate scalable, low-income residential electrification across the Monterey Bay region over a 36-month performance period. The original production goal was to electrify at least 50 households; CCES exceeded this benchmark by completing electrification work in 86 households. Targeting criteria prioritized households located in disadvantaged communities and/or with an energy burden >6.5% (defined as average household energy costs divided by average household countable income). Across participating households, the average energy burden was 28%, indicating a high-need population and supporting the program’s equity and affordability objectives.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electric Utility Distribution Costs: Scoping Study on Trends, Drivers, and Possible Response Strategies [Slides]

This scoping study synthesizes information that will help stakeholders understand the scope, scale, and drivers of recent increases in investor-owned utility (IOU) expenditures on local distribution power grids, while providing regulators and other decision-makers with potential strategies to keep electricity bills down. The study includes five distinct components. Drawing first on data from FERC Form 1, it summarizes key trends in past and recent IOU distribution costs. Next, through a review of a sample of distribution-system plans, it characterizes material drivers of planned distribution expenditures. Ultimately, regulators must approve cost recovery for IOU expenditures, including those for the distribution system. The study therefore also: examines trends in utility requests and regulatory approvals related to changes in retail rates and return on equity; identifies areas where utility shareholder and customer incentives may be misaligned; and develops a menu of options that state regulators might consider to optimize distribution system expenditures. Some of the key findings include: - IOU distribution spending at a national level has grown by 6%/yr since 2014 in real dollar terms, 4x faster than in the prior 20 years and consisting mostly of capital (not operating) expenditure. - On a per-kWh basis, increases in IOU distribution costs since 2014 represent over 30% of the overall national-average increase in retail electricity rates. - Regional spending growth has ranged from 2-8%/yr, with larger estimated rate impacts in CAISO, then NYISO & ISO-NE, and then the Southeast, MISO & PJM (see figure). - Some utilities are planning for significantly increased distribution system spending. Planned spending on managing the existing system (asset replacement, safety & reliability, and resilience are all important drivers) exceeds that for capacity expansion. - IOU rate increase requests ($18 billion in 2025) and public utility commission (PUC) approval levels (average of 64% of requested amounts from 2021-2025) have recently hit multi-decadal highs. - PUCs in New England and the Southeast have recently approved a greater fraction of rate requests (>75%, on average) than in ther regions, while PUCs in California and the Southeast have generally authorized higher equity returns than in other regions. - Regulators have many tools to tackle potential misalignments between utility and customer interests and, more specifically, to optimize and reduce distribution costs. Shorter-term options include those related to return on equity, capital structure, depreciation, trackers, construction work in progress, and securitization. Longer-term options include performance-based regulation and a wide variety of planning-related requirements. All options embed important tradeoffs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SILICON CARBIDE THERMOMETRY USING RAMAN SPECTROSCOPY ON IRRADIATED TRISO PARTICLES

Silicon carbide (SiC) passive thermometry has emerged as a promising post-irradiation examination (PIE) technique for estimating irradiation temperature near the end of irradiation. While dilatometry techniques have been traditionally used to analyze prismatic samples after irradiation, Raman spectroscopy has recently been shown to provide comparable results by analyzing Raman-active phonon modes. In this work, Raman spectroscopy has been applied to the SiC layer of cross-sectioned irradiation tristructural isotropic (TRISO) particles from the AGR-5/6/7 experiment to evaluate the feasibility of particle-scale passive thermometry. Two-dimensional Raman mapping was used to measure the position of the SiC longitudinal optical (LO) phonon, which was then converted to an apparent irradiation temperature using a previously established empirical correlation. Particles from AGR-5/6/7 Compacts 2-2-1 and 5-1-3 were selected as their calculated time-averaged, volume-averaged (TAVA) temperatures (828°C and 706°C, respectively) fall within the range of the sensitivity of the experimental approach. The use of SiC thermometry was anticipated to confirm or highlight potential deviations from calculated end-of-life TAVA temperature across compacts. Four particles from Compact 2-2-1 and two particles from Compact 5-1-3 were selected based on 110mAg inventory (either some measurable activity or below the minimum detection limit) which is commonly used as an indicator of in-pile temperature variation of particles within the same compact. Across every particle selected it was determined that the average LO peak position was located around 968 cm-1 to 969 cm-1. Using the previously determined empirical correlation, this corresponds to an irradiation temperature around 950°C to 966°C, which does not align with the reported TAVA temperature values. This discrepancy in apparent irradiation temperatures likely reflects a combination of uncertainties in the calculated particle temperatures and differences in irradiation history between the present specimens and those used to establish the empirical Raman calibration such as neutron flux (damage rate) and SiC microstructure (as fabricated and irradiated).

Vawdrey, Josh [ORNL]↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset consists of NPDs in the conterminous US with at least 100kW of theoretical potential based on earlier resource assessments. Historical daily streamflow (modeled or from USGS gauge records), hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs for HydroGenerate which determines design flow and turbine efficiencies and then calculates nominal capacity, daily generation, and capacity factor. These outputs are summarized on a monthly basis (i.e., generation (MWh) and capacity factor averaged for each month from January to December) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of 4.1 GW capacity is estimated across all 2,564 NPDs included in the dataset.

13 HYDRO ENERGY↗

Technical Potential for Hydropower Capacity at Non-powered Dams

In the last decade, retrofits of existing nonpowered dams (NPDs) have made up the largest share of capacity increases for US hydropower. Accurate estimates of potential capacity and generation at NPDs help identify sites that may be worth investing in detailed feasibility analyses and design exploration. This dataset contains estimates of technical potential capacity and generation at 2,616 NPDs in the conterminous US. This is based on a subset of dams that were found by earlier resource assessments to have at least 100kW of theoretical potential. Historical daily streamflow (modeled or from USGS gauge records) and hydraulic head (based on historical observations or primary purpose and dam height) are the main inputs to the HydroGenerate model, which determines design flow, turbine efficiencies, and assumed friction losses and then calculates nominal capacity, daily generation, and capacity factor. These estimates represent the conditions over the historical period of 1980-2015, and are summarized on a monthly basis (i.e., averaged for each month of the year) and overall (i.e., nominal capacity, average annual generation (MWh), and average annual capacity factor). A total of nearly 4 GW capacity is estimated across all 2,616 NPDs included in the dataset.

Hansen, Carly [Oak Ridge National Laboratory (ORNL↗

Chapter 7.1: Microalgae

Microalgae is a unique biomass resource that does not need to compete for land and water with other biomass feedstocks because it can be cultivated on low-quality unencumbered land using noncompetitive water types including saline and wastewater. It is included as a complementary resource alongside other biomass feedstocks reported in this study, albeit at higher biomass production costs reflective of more capital-intensive farming operations than typical for terrestrial biomass. Higher biomass costs can be offset by the potential to produce value-added coproducts unique to compositional constituents of microalgae. Relative to BT16, this chapter reflects the latest analysis from the 2022 Algae Harmonization Update, which uses the latest parameterized and high-performing saline algal strain, second-generation carbon capture of point-source waste CO2 and high-pressure pipeline transport resolved to specific point-source types, saline water sourcing up to 40,000 mg/L total dissolved solids for source and makeup water salinity, blowdown water treatment and recycle, and brine disposal handling. National-scale algal biomass availability potential was calculated at 152 million tons/yr ash-free dry weight (AFDW) (191 million tons/yr dry weight) at an average biomass productivity of 26.2 g/m2 -day AFDW (about 50 tons/acre/yr dry weight).1 The algal biomass was cultivated on 3.9 million acres of multi-criteria screened and potentially available land for CONUS and fixed 268 million tons of waste CO2 based on biomass uptake. The algae biomass can be produced at an average MBSP of $674/ton AFDW ($536/ton dry weight) in 2020 dollars,2 corresponding to a total energy potential of 3.3 quads/yr at an average MBSP of $31.2/MMBtu (higher-heating-value [HHV] basis).

algae↗

Surface Structure of Reacting Solid Ramjet Fuels

Solid fuel ramjets are a developing technology that will enable extended range for supersonic vehicles. The simplicity of the system in terms of moving parts results in the performance being dictated by the solid fuel combustion processes. The physics near the surface, particularly in the fuel-rich recirculation zone, are challenging to resolve due to flow opacity. Here, regression rate measurements of hydroxyl-terminated polybutadiene from a miniature, portable slab burner are reported. Mass-averaged regression rates agree with correlations from the literature, suggesting that the proper physics in the burner are captured. Synchrotron-based phase-contrast imaging is used to quantify local surface features, including a multiphase froth layer, molten polymer transport, and local regression rate measurements in the recirculation zone. Regression rates near the inlet are less than the mass-averaged values, whereas near the reattachment point the local value exceeds the mass-averaged values. Further, the observed froth layer is as large as 2 mm near the inlet and decreases to sub-millimeter thicknesses near the reattachment point. An analytical heat transfer model is used to quantify the influence of the surface froth layer on the regression rates. Results indicate that the froth layer has an insulating effect and will reduce the local regression rate.

33 ADVANCED PROPULSION SYSTEMS↗

Transducer Resolution Effect on Pressure Fluctuations Beneath Hypersonic Turbulent Boundary Layers

The size of a pressure transducer is known to affect the accuracy of measurements of wall-pressure fluctuations beneath a turbulent boundary layer because of spatial averaging over the sensing area of the transducer. In this paper, the effect of finite transducer size is investigated by applying spatial averaging or wavenumber filters to a database of hypersonic wall pressure generated from a direct numerical simulation (DNS) that simulates the turbulent portion of the boundary layer over a sharp 7° half-angle cone at nominally Mach 8. Here, a good comparison between the DNS and the experiment in the Sandia Hypersonic Wind Tunnel at Mach 8 is achieved after spatial averaging is applied to the DNS data over an area similar to the sensing area of the transducer. The study shows that a finite sensor size similar to that of the PCB132 transducer can cause significant attenuation in the root-mean-square and power spectral density (PSD) of wall-pressure fluctuations, and the attenuation effect is identical between cone and flat plate configurations at the same friction Reynolds number. The Corcos theory is found to successfully compensate for the attenuated high-frequency components of the wall-pressure PSD.

42 ENGINEERING↗

Derivation of A Representative Elementary Volume (REV) for Upscaled Two-Phase Flow in Porous Media

Relative permeability plays an important role in the upscaling of multiphase flow in porous media from the pore scale to the Darcy scale. The entire concept of relative permeability is contingent on the existence of a representative elementary volume (REV). As we move to smaller samples to measure relative permeability, such as with digital core analysis, the concept of a classical REV has become increasingly unlikely when using the conventional approach to defining a representative volume. The “‘conventional”’ understanding of an REV is that a large enough volume must be considered such that spatial variability averages out. In digital rock methods, such as pore-scale simulations based on micro-computed tomography (CT) images, the domain size is typically 2 to 4 mm. This is approximately the length scale of a single-phase flow REV using the classic REV approach. However, the single-phase perspective does not consider the complex dynamics and fluctuations often observed in multiphase flow systems, even at centimeter-scale experiments and/or simulations. A fundamental question is, therefore, whether the domain size commonly used in digital rock simulations can provide a consistent energy budget such that the concept of relative permeability exists. Based on first principles, relative permeability accounts for the rate of energy dissipated in a stationary process. If the dynamics are fluctuating, the energy dissipated can vary but will average out over a long enough timescale. The key to determining the validity of the relative permeability is the timescale of the measurement, not the spatial scale. The conventional REV theory assumes that spatial, temporal, and ensemble averages are equivalent in an ergodic system, but it does not provide a way to test this assumption. We provide a formal way to identify the timescale where the relative permeability accurately captures energy dissipation as a way to validate relative permeability measurements and quantitatively assess their accuracy. This result will be tested for a practical SCAL test, determining how long a flow experiment needs to be run to accurately characterize the rate of energy dissipation by the flow. The outcome will be a best practice guide for the determination of relative permeability from core-scale experiments and/or digital core simulations that ensure the energy budget is fully accounted for in the relative permeability coefficient.

Mcclure, James [Virginia Tech, Blacksburg]↗

Interfacial pressure improves calendar aging of lithium metal anodes

Lithium (Li) metal is a promising anode because its theoretical specific capacity is approximately ten times larger than graphite. However, Li anodes suffer from long-term capacity fade due to Li stranding (becoming electronically disconnected) and electrolyte decomposition. Applied interfacial pressure has been shown to improve Li anode cycling, likely due to reincorporating stranded or “dead” Li into the anode. Calendar aging can also lead to Li capacity loss due to electrolyte decomposition/Li corrosion and the formation of stranded Li. Some research suggests that calendar aging during cycling results in reversible capacity losses due to Li stranding and reconnection. We here investigate the effect of applied interfacial pressure on Li anode calendar aging during cycling with incorporated rest steps in a localized high-concentration electrolyte (LHCE) to understand if pressure can mitigate stranded Li formation during rest by manipulating the Li morphology. Pouch cells exhibit more stable cycling and denser Li deposits between 10 kPa and 1,000 kPa of applied pressure compared to no applied pressure. Despite drops in CE during periodic rest cycles, the average cumulative lost capacity and average coulombic efficiency (CE) of cells over 50 cycles show that cells aged with incorporated rest steps perform similarly to cells cycled without added rests. This similar average CE suggests that dead Li is largely responsible for drops in CE during rest rather than irreversible Li corrosion and that the dead Li can be reconnected in subsequent cycling. The addition of a lithiophilic ZnO coating to the Cu working electrode increases the adhesion and coverage of Li deposits at low pressures and improves CE during the first cycle.

25 ENERGY STORAGE↗

Physics-Informed Deep Learning for Reconstruction of Spatial Missing Climate Information in the Antarctic

Understanding the influence of the Antarctic on the global climate is crucial for the prediction of global warming. However, due to very few observation sites, it is difficult to reconstruct the rational spatial pattern by filling in the missing values from the limited site observations. To tackle this challenge, regional spatial gap-filling methods, such as Kriging and inverse distance weighted (IDW), are regularly used in geoscience. Nevertheless, the reconstructing credibility of these methods is undesirable when the spatial structure has massive missing pieces. Inspired by image inpainting, we propose a novel deep learning method that demonstrates a good effect by embedding the physics-aware initialization of deep learning methods for rapid learning and capturing the spatial dependence for the high-fidelity imputation of missing areas. We create the benchmark dataset that artificially masks the Antarctic region with ratios of 30%, 50% and 70%. The reconstructing monthly mean surface temperature using the deep learning image inpainting method RFR (Recurrent Feature Reasoning) exhibits an average of 63% and 71% improvement of accuracy over Kriging and IDW under different missing rates. With regard to wind speed, there are still 36% and 50% improvements. In particular, the achieved improvement is even better for the larger missing ratio, such as under the 70% missing rate, where the accuracy of RFR is 68% and 74% higher than Kriging and IDW for temperature and also 38% and 46% higher for wind speed. In addition, the PI-RFR (Physics-Informed Recurrent Feature Reasoning) method we proposed is initialized using the spatial pattern data simulated by the numerical climate model instead of the unified average. Compared with RFR, PI-RFR has an average accuracy improvement of 10% for temperature and 9% for wind speed. When applied to reconstruct the spatial pattern based on the Antarctic site observations, where the missing rate is over 90%, the proposed method exhibits more spatial characteristics than Kriging and IDW.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Mechanical Draft Cooling Tower Thermal Emissions from Visual Images of Plumes

Using a one-dimensional code, we computed the power (enthalpy discharge rate) of a twelve-cell mechanical draft cooling tower (MDCT) using over two hundred visible condensed water vapor plume volume measurements derived from images, weather data, and tower operating conditions. The plume images were simultaneously captured by multiple stationary digital cameras surrounding the cooling tower. An analysis technique combining structure from motion (SfM), a neural-network-based image segmentation algorithm, and space carving was used to quantify the volumes. Afterwards, the power output was computed using novel techniques in the one-dimensional code that included cooling tower exhaust plume adjacency effects implemented with a modified version of the entrainment function, weather data averaged from eleven stations, and fan operations at the times when plume volumes were measured. The model was then compared with the averaged observed power output, and it validated well with an average error ranging from 6 to 12%, depending on the meteorological data used in the simulations. This methodology can possibly determine power plant fuel consumption rates by applying visible imagery.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗