Discrete event simulation and the resultant data storage system response in the operational mission environment of Jupiter-Saturn /Voyager/ spacecraft

The Data Storage Subsystem Simulator (DSSSIM) simulating (by ground software) occurrence of discrete events in the Voyager mission is described. Functional requirements for Data Storage Subsystems (DSS) simulation are discussed, and discrete event simulation/DSSSIM processing is covered. Four types of outputs associated with a typical DSSSIM run are presented, and DSSSIM limitations and constraints are outlined.

Mukhopadhyay, A. K.↗

System and method for phase retrieval for radio telescope and antenna control

Disclosed herein are systems, methods, and non-transitory computer-readable storage media for radio phase retrieval. A system practicing the method gathers first data from radio waves associated with an object observed via a first aperture, gathers second data from radio waves associated with the object observed via an introduced second aperture associated with the first aperture, generates reduced noise data by incoherently subtracting the second data from the first data, and performs phase retrieval for the radio waves by modeling the reduced noise data using a single Fourier transform. The first and second apertures are at different positions, such as side by side. This approach can include determining a value Q which represents a ratio of wavelength times a focal ratio divided by pixel spacing. This information can be used to accurately measure and correct alignment errors or other optical system flaws in the apertures.

Dean, Bruce H.↗

Ground Operations Demonstration Unit for Liquid Hydrogen Initial Test Results

NASA operations for handling cryogens in ground support equipment have not changed substantially in 50 years, despite major technology advances in the field of cryogenics. NASA loses approximately 50% of the hydrogen purchased because of a continuous heat leak into ground and flight vessels, transient chill down of warm cryogenic equipment, liquid bleeds, and vent losses. NASA Kennedy Space Center (KSC) needs to develop energy-efficient cryogenic ground systems to minimize propellant losses, simplify operations, and reduce cost associated with hydrogen usage. The GODU LH2 project has designed, assembled, and started testing of a prototype storage and distribution system for liquid hydrogen that represents an advanced end-to-end cryogenic propellant system for a ground launch complex. The project has multiple objectives including zero loss storage and transfer, liquefaction of gaseous hydrogen, and densification of liquid hydrogen. The system is unique because it uses an integrated refrigeration and storage system (IRAS) to control the state of the fluid. This paper will present and discuss the results of the initial phase of testing of the GODU LH2 system.

liquefaction↗

A Passive fuel-Cell Surface power System (PaCeSS)

This effort produces a fully-passive surface power generation capability for fuel cell technology. The concept replaces the actively pumped thermal management of a state of the art (SOA) fuel cell/electrolyzer stack with a passive 2-phase thermosyphon for heat transport and a passive shape memory actuating radiator for temperature management. The concept addresses NASA fuel cell technology roadmap needs for greater reliability and longer operating life by eliminating life limiting elements of SOA fuel cell system design that drive failure modes associated with moving parts and control complexity. Applications map to surface power (primary fuel cell), surface energy storage (regenerable fuel cell) and in-situ resource utilization (electrolyzer/unitized reversible fuel cell). The first year of this effort concluded with independent demonstrations of 2-phase thermosyphon heat transport from a simulated fuel cell and temperature driven actuation of a shape memory actuating radiator. Results are in-character with underlying physics and demonstrate the potential to realize the objectives of this concept. his effort produces a fully-passive surface power generation capability for fuel cell technology. The concept replaces the actively pumped thermal management of a state of the art (SOA) fuel cell/electrolyzer stack with a passive 2-phase thermosyphon for heat transport and a passive shape memory actuating radiator for temperature management.

deionized water↗

Devices and systems for material transportation

Various embodiments relate to devices for transporting high-assay low-enriched uranium (HALEU). A device may include at least one section, wherein each section of the at least one section includes a number of storage tubes. Each storage tube, which is configured to receive and hold a container, extends from adjacent a first end of the section toward a second, opposite end of the section. Each section further includes a number of flux traps, wherein each storage tube of the number of storage tubes is at least partially surrounded by a flux trap of the number of flux traps Associated systems are also disclosed.

Eidelpes, Elmar F.↗

The impact of non-ideal phase change properties on phase change thermal energy storage device performance

Phase change materials have been known to improve the performance of energy storage devices by shifting or reducing thermal/electrical loads. While an ideal phase change material is one that undergoes a sharp, reversible phase transition, real phase change materials do not exhibit this behavior and often have one or more non-idealities – glide, hysteresis, supercooling – associated with them. Experimental and modeling techniques to characterize these non-ideal properties are reasonably well understood, however, their impact on the performance of a thermal energy storage system is not fully understood. Herein, we analyze the performance of a heat exchanger with a phase change material as a function of the different non-idealities, for a heating and a cooling application. We focus on the impact of these non-ideal behaviors on different modes of operation of the thermal energy storage device, which will serve as a useful guide to researchers on the relative importance of the non-ideal properties, along with the necessary accuracy required during an experimental characterization.

25 ENERGY STORAGE↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule-Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency RTE to increase the temperature of heat rejection. This paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost trade-offs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat, including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorable versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous United States in high temperature scenarios.

CHP↗

FARM supervisory capabilities for thermal energy storage

The FARM (Feasible Actuator Range Modifier) module is a component of the RAVEN-based FORCE framework for the analysis of Integrated Energy Systems (IES). FARM aids HERON in the solution of the power dispatch problem by evaluating feasible set-point signals to be issued to the control systems of the different IES unit components. Set-points need to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). To enforce all these limits, a two-stage approach is adopted. First, the power dispatcher algorithm in HERON module estimates set-points that meet the constraints on the production variables, e.g., power levels and power ramp rate limits. These constraints are called explicit constraints. Then, if necessary, FARM adjusts these set-points to ensure the respect of the limits on the process variables of interest, given the knowledge of the system dynamics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). In this report, an overview of the major capabilities of the latest release of FARM is provided, along with a summary of the tool demonstration campaign conducted at the Dynamic Energy Technology and Integration Laboratory (DETAIL) facility. These results assess the performance of the control system architecture embedding FARM both as a Validator of the HERON power dispatcher and as a real time Supervisory control scheme. Additionally, the report outlines the areas that FARM might benefit from, along with proposed solutions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Solar +: Clean Energy Strategies for the Sunshine State (Final Technical Report (FTR) of the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR))

This reports on a four-year effort to provide foundational research, analysis, strategies and assistance to help Florida, and other states that might learn from this work, to grow solar energy in conjunction with other distributed energy resources by addressing and overcoming existing barriers, and in way that delivers increased value. The start of this effort coincided with an inflection point of sorts into a new dawn for solar energy in Florida, where the Sunshine state’s national ranking in total installed solar, according to the Solar Energy Industries Association (SEIA), has rose from 13th to 4th. Florida has now become the national leader in annual utility-scale solar growth as dozens of large plants have come online. Also, during this time, Florida utilities have expressed a strong and growing interest in understanding the role of energy storage and how to best plan for and deploy this unique resource as part of strategies to grow solar. The utility-scale solar growth experienced has been fueled by the economics of solar cost-parity with natural gas combined cycle plants and Florida Public Service Commission’s (PSC) approval of cost-recovery for the Investor-Owned Utilities (IOU’s), primarily through the Solar Base Rate Adjustment (SoBRA) mechanism. This has led to gigawatts (GW’s) of rate-based solar capacity additions over several years, along with fairly significant amounts of energy storage. Meanwhile, municipal electric utilities, which, collectively, are the third largest source of power in the state, have been increasing solar considerably through power purchase agreements (PPA’s) and are on track to have close to 1 GW of grid-connected solar by 2024. Florida’s municipal utilities and the Florida Municipal Electric Association (FMEA) have been key partners in the Florida Alliance for Accelerating Solar and Storage Technology Readiness (FAASSTeR), formed to carry out this effort. The six largest of these have been Core Team utilities, engaging throughout the project in weekly calls, discussions, and project direction, participating in and hosting workshops and benefiting from technical assistance in several areas.

14 SOLAR ENERGY↗

Design-Point Techno-Economics of Brayton Cycle PTES for Combined Heat and Power

Pumped thermal energy storage (PTES) systems are grid batteries that use heat pumps to create both hot and cold thermal energy stores when there is excess electricity and then use a power cycle to convert the thermal energy into electricity when there is demand for electricity. In normal operation, Joule–Brayton PTES discharges low-grade heat at temperatures useful for thermal energy consumers like district and industrial heating. Furthermore, PTES designs, like conventional combined heat and power (CHP) technology, can be modified to sacrifice some round-trip efficiency (RTE) to increase the temperature of heat rejection. Here, this paper uses design-point performance and cost models that provide a detailed understanding of the efficiency and cost tradeoffs of rejecting heat at various temperatures in ideal-gas Brayton PTES configurations. First, we keep the heat rejection in its nominal location in the PTES system: in the discharge cycle after the low-pressure exit of the recuperator before the cold-storage heat exchanger. Next, we move the heat rejection to the discharge turbine exit. We define design-point metrics that isolate both the cost and performance penalty associated with the hotter heat rejection and attribute it exclusively to the heat economic metrics. Finally, we estimate the performance of electric heater technology to generate heat at equivalent temperatures. We find that the levelized cost of heat (LCOH), including the cost of thermal energy storage (TES) buffering the PTES and heat off-taker, compares favorably versus electric technologies and is less than the cost of natural gas for low temperature scenarios and competitive with the cost of natural gas in some regions of the contiguous U.S. in high temperature scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Super enrichments of Fe-group nuclei in solar flares and their association with large He-3 enrichments

Data on solar flares and perodic particle intensity enhancements in the energy range from 1 to 20 MeV/n are examined. It is found that: (1) Fe/He-4 ratios range from about 1 to 1000 times the solar ratio of 0.0004; (2) these high ratios mitigate against extended storage and large amounts of nuclear processing; (3) the CNO/He-4 ratio has a much smaller range of variability and a mean value of 0.02; (4) large He-3 and Fe enrichments are strongly associated, but not on a one-to-one basis; (5) large Fe enhancements sometimes occur without correspondingly large He-3 enrichments; and (6) none of the models so far advanced adequately explains the observed He-3 and heavy-nucleus enrichments.

Anglin, J. D.↗

Delivery of Dynamic Thermal Energy Storage Models and Advanced Reactor Concept Models to the HYBRID Repository

This publication details newly created energy storage and reactor models developed within the HYBRID modeling repository as part of the Department of Energy Office of Nuclear Energy (DOE-NE) Integrated Energy Systems (IES) program, led by Idaho National Laboratory (INL). Model development to-date includes creation of dynamic systems-level models of a pebble bed high temperature gas reactor (HTGR), sodium fast reactor (SFR), compressed air energy storage (CAES), liquid air energy storage (LAES) and Modelica standard library based two-tank sensible heat storage (SHS) in the IES-based HYBRID repository. Models are developed using the latest publicly available data and incorporate the possibility of control strategy inclusion for use with the existing IES modeling, analysis, and optimization toolset. Simulations showcase the abilities of each technology to flexibly operate in ways consistent with IES operation expectations. When these models are available, they can be utilized within different integrated energy park concepts to understand optimal system operation, control, and dispatching. Moreover, given the generic nature of the models, industrial partner technologies can be quickly added to the repository using the existing models as a basis. Additional dynamic models for thermal energy storage concepts can be developed and added to the HYBRID repository as needed. Also detailed in this report are future development goals for the HYBRID repository including adding suites of steady-state models, economic costing information, and reduced-order models. By adding these models in addition to the physical transient models currently existing within HYBRID, HYBRID will be a fully integrable tool for FORCE users.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Redesign of the Apollo cryogenic storage system

An assessment of the Apollo 13 mission resulted in establishing new and revised requirements for the design of the oxygen tanks and the associated spacecraft system. Areas discussed include new system requirements, system changes to Apollo 14, revised operational requirements, instrumentation, operational redlines, component isolation modes, and return enhancement capabilities. In order to show the relationship of the cryogenic system to the spacecraft, a short description of the system is presented.

Bouman, C. P.↗

Global warming potential estimates of mass timber constructions beyond the first life: A dynamic radiative forcing modeling approach

In the face of a warming planet, steps must be taken to reduce the greenhouse gas emissions (GHG) associated with our building industry, which is a significant contributor to global emissions. Large, prefabricated wood elements such as mass timber panels (MTP) have great potential to achieve these reductions as they help displace high-embodied‑carbon materials like concrete and steel. Furthermore, storing the wood's biogenic carbon in buildings benefits the climate because it delays the eventual release of the carbon into the atmosphere. While these climate impacts have been assessed for the construction phase of mass timber buildings, relatively few life cycle assessment (LCA) studies have evaluated the climate impacts for the buildings' end-of-life (EOL) phase. This research estimates the climate impacts of four EOL scenarios for MTP: reusing as MTP, recycling into particleboard, incinerating, and landfilling. Using dynamic radiative forcing modeling and factoring in temporal GHG emissions and biogenic carbon storage, the global warming potential impacts are calculated for construction, deconstruction, and EOL processing of hybrid mass timber buildings in the U.S. Pacific Northwest for 160 years (GWP 160 ). The 160-year temporal scale used in this paper is an arbitrary scale, with the first 80 years being the assumed life of the building, followed by a series of reuse, recycle, or disposal scenarios over the second 80 years of that temporal scale. Of the four EOL scenarios considered in this paper, the ‘reuse’ scenario has the lowest net GWP 160 impact (calculated by summing the GWP 160 and carbon storage benefits, i.e., GWP$^{bioCS}_{160}$ ), emerging as a climate-preferred scenario, followed by ‘landfill’, ‘incinerate’, and ‘recycle’ scenarios. The lower net GWP 160 impact associated with the reuse scenario is due to the low fossil carbon emissions during EOL processing, as well as the biogenic carbon storage benefits. The results of this study also highlight the importance of efficient reuse and recycling strategies for wood in MTP.

42 ENGINEERING↗

Tree Diversity, Site Index, and Carbon Storage Decrease With Aridity in Douglas-Fir Forests in Western Canada

Forests are important for biodiversity, timber production and carbon accumulation, but these ecosystem services may be impacted by climate change. Field data collected from individual forest types occurring across a climatic gradient can contribute to forecasting these consequences. We examined how changes in temperature, precipitation and aridity affect ecosystem services in 23 mature Douglas-fir (Pseudotsuga menziesii) forests in nine climatic regions across a 900 km gradient in British Columbia, Canada. Using Canadian National Forest Inventory methodology, we assessed richness and diversity of plant functional groups, site index, and above- and below-ground carbon stocks. As aridity increased, ecosystem-level tree species richness declined on average from four to one species, Douglas-fir site index declined from 30 to 15 m, and ecosystem carbon storage decreased from 565 to 222 Mg ha –1 . Tree species richness was positively and herb species richness negatively correlated with carbon storage. Carbon storage by ecosystem compartment was largest in aboveground live tree biomass, declining in the following order: mineral soils > coarse woody debris and dead standing trees > forest floor > small and fine woody debris > understory plants. Mineral soil carbon at depths of 0-15 cm, 15-35 cm, and 35-55 cm increased with increasing mean annual precipitation and decreasing aridity. Our results indicate that as aridity increases and precipitation decreases, tree species richness, site index and carbon storage in existing Douglas-fir forests declines. However, assisted or natural migration of Douglas-fir into more humid regions could be associated with more diverse, productive, carbon-rich forests. This study informs carbon stock vulnerability and provides empirical data essential for carbon stock forecasts.

54 ENVIRONMENTAL SCIENCES↗

HYBRID Modeling Validation and Verification Status Matrix

The HYBRID modeling repository is a premier resource for integrated energy systems modeling. HYBRID models have been developed since 2015 to describe the physical operation of tightly coupled thermal systems including power generators, thermal transport systems, thermal storage, thermal-to-electric conversion systems, and other thermal applications. Due to the increased size of the repository, a concise summary matrix of available models is desired. This matrix will consolidate not only the list of available models but also indicate original information sources, publications that have model examples, and level of validation and verification that exists for the models. Validation and verification (V&V) levels begin from simplified algebraic relationship and advance to dynamic data validation. Moving forward, as new models are contributed to HYBRID, their V&V level will be included, updating this matrix.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

FECM/NETL Offshore CO2 Saline Storage Cost Model

The FECM/NETL Offshore CO2 Saline Storage Cost Model (CO2_S_COM_Offshore) estimates costs for a CO2 storage project in an offshore saline formation or reservoir. It is applicable for storage projects located on the Outer Continental Shelf of the Gulf of America. The purpose is to model the costs associated with a project, using simplified geo-engineering equations to calculate reservoir values needed to determine costs (such as CO2 plume area and number of injection wells). To use the model, change any of the inputs, which are always in orange cells, to the values you desire. Although there are numerous values that can be changed, the values expected to be of most interest have input cells on the 'Key_Inputs' sheet. Last update: 5/2/2025; Version 1.1 corrects bug in reservoir thickness calculations.

Carbon storage↗