At least 685 records · Page 38

Sensitivity Studies of Air Ingress Acidents in Modular HTGRs

Postulated air ingress accidents, while of very low probability in a modular high-temperature gas-cooled reactor (HTGR), are of considerable interest to the plant designer, operator, and regulator because of the possibility that the core could sustain significant damage under some circumstances. Sensitivity analyses are described that cover a wide spectrum of conditions affecting outcomes of the postulated accident sequences, for both prismatic and pebble-bed core designs. The major factors affecting potential core damage are the size and location of primary system leaks, flow path resistances, the core temperature distribution, and the long-term availability of oxygen in the incoming gas from a confinement building. Typically, all the incoming oxygen entering the core area is consumed within the reactor vessel, so it is more a matter of where, not whether, oxidation occurs. An air ingress model with example scenarios and means for mitigating damage are described. Representative designs of modular HTGRs included here are a 400-MW(th) pebble-bed reactor (PBR), and a 600-MW(th) prismatic-core modular reactor (PMR) design such as the gas-turbine modular helium reactor (GT-MHR).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Charge Analyzer Responsive Local Oscillations

The first transatlantic radio transmission, demonstrated by Marconi in December of 1901, revealed the essential role of the ionosphere for radio communications. This ionized layer of the upper atmosphere controls the amount of radio power transmitted through, reflected off of, and absorbed by the atmospheric medium. Low-frequency radio signals can propagate long distances around the globe via repeated reflections off of the ionosphere and the Earth's surface. Higher frequency radio signals can punch through the ionosphere to be received at orbiting satellites. However, any turbulence in the ionosphere can distort these signals, compromising the performance or even availability of space-based communication and navigations systems. The physics associated with this distortion effect is analogous to the situation when underwater images are distorted by convecting air bubbles. In fact, these ionospheric features are often called 'plasma bubbles' since they exhibit some of the similar behavior as underwater air bubbles. These events, instigated by solar and geomagnetic storms, can cause communication and navigation outages that last for hours. To help understand and predict these outages, a world-wide community of space scientists and technologists are devoted to researching this topic. One aspect of this research is to develop instruments capable of measuring the ionospheric plasma bubbles. Figure 1 shows a photo of the Charge Analyzer Responsive to Local Oscillations (CARLO), a new instrument under development at NASA Marshall Space Flight Center (MSFC). It is a frequency-domain ion spectrum analyzer designed to measure the distributions of ionospheric turbulence from 1 Hz to 10 kHz (i.e., spatial scales from a few kilometers down to a few centimeters). This frequency range is important since it focuses on turbulence scales that affect VHF/UHF satellite communications, GPS systems, and over-the-horizon radar systems. CARLO is based on the flight-proven Plasma Local Anomalous Noise Environment (PLANE) instrument, previously flown on a U.S. Air Force low-Earth orbiting satellite, which successfully measured ion turbulence in five frequency decades from 0.1 Hz to 10 kHz (fig 2).

Krause, Linda Habash↗

Comprehensive Analysis of Model Parameter Uncertainty Influence on Evaluation of HVAC Operation to Mitigate Indoor Virus: A Case Study for an Office Building in a Cold and Dry Climate

Simulation-based studies of HVAC operation to mitigate indoor virus have been conducted to understand tradeoffs between indoor air quality (IAQ) and energy consumption. However, the influence of model parameter uncertainty in these studies has not been systematically quantified, which is critical when providing guidance to building operators. To address this gap, we identify 20 model parameters for a typical medium office building system in a cold and dry climate that can influence IAQ and energy consumption for indoor virus scenarios. Next, the distributions of the parameter values are estimated from literature and a set of simulation samples for three representative days is generated that simultaneously sample all of the parameters from their distributions. Two HVAC virus mitigation strategies are studied: increased filtration using MERV 13 filters and increased ventilation, via supply of 100% outdoor air into buildings. The model parameter uncertainty leads to significant variability in the results, particularly for the IAQ because of the highly uncertain virus generation rate. Use of 100% outdoor air can be beneficial for some uncertain scenarios on the hot day, but shows less IAQ improvement and/or significant energy increases on the other days. The virus removal efficiency and pressure drop of the HVAC filter, fan efficiency, and internal heat gain are the most important parameters to determining the tradeoffs of the two strategies. Our results demonstrate how this model parameter uncertainty analysis methodology can provide practical guidance to building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Aerodynamic effects on outer ash deposition rates in second generation atmospheric pressure oxy-coal combustion systems

Recent measurements in scenarios representative of second generation atmospheric pressure oxy-coal combustion systems have shown a significant increase in ash deposition rates in comparison to combustion in air. However, the causative mechanisms behind this increase have not been well understood. To fill this void, well-characterized experiments including fuel and deposit particle size distributions (PSDs) were coupled with highly resolved numerical simulations to isolate the aerodynamic effects impacting the deposition process such that mechanisms could be hypothesized. Three combustion scenarios (AIR, OXY27, OXY70) spanning a factor of three variation in flue gas volumetric flow rates were simulated and the deposition characteristics (impaction rates, deposit PSD, temperature, residence times, capture rates) tracked/predicted using a customized deposition module. The measured deposit PSD was significantly different from the PSD of the parent fuel indicating significant physio-chemical transformations (coalescence and particle growth in particular) at play. The use of simplistic modeling approaches (swelling parameter variations) to model particle growth led to inaccurate deposit ash PSD and rate predictions. A more satisfactory agreement between the measurements and simulations was obtained when the functional form of the parent fuel PSD (spread parameter) was modified to conform closely to the deposit PSD while still ensuring the fidelity of temperature and velocity predictions. Based on the measured ash compositions, identical capture criteria were employed across all three scenarios. Here this study further supports the theory that the ash deposition rates in these systems are dominated by aerodynamic effects with the ash PSD playing a dominant role.

42 ENGINEERING↗

Operating a commercial building HVAC load as a virtual battery through airflow control

Virtual battery (VB) is an innovative method to model flexibility of building loads and effectively coordinate them with other resources at a system level. Unlike a real battery with a dedicated power conversion system for charging control, methods are required for operating building loads to deviate from the baseline to respond to grid signals. This paper presents a VB control for a commercial heating, ventilation, and air conditioning (HVAC) system to follow the desired power consumption in real-time by adjusting zonal airflow rates. The proposed method consists of two parts. At the system level, a mixed feedforward and feedback control is used to estimate the desired total airflow rate. At the zone level, two priority-based algorithms are then proposed to distribute the total airflow rate to individual zones. In particular, a zonal airflow limit estimation method is proposed using machine-learning techniques, in contrast to physics-based thermal models in existing studies, to more accurately capture zonal thermal dynamics and improve temperature control performance. An office building on the Pacific Northwest National Laboratory campus is implemented in EnergyPlus, and used to illustrate and validate the proposed control.

Wang, Jiyu↗

Atomization of liquid fuels. Part I

In the present treatise we will consider chiefly the problem of solid injection in comparison with air injection. On leaving the valve or nozzle through one or more small openings, the fuel is split up into innumerable fine drops, which penetrate the combustion chamber in divergent directions in the form of a conical jet. The efficiency of this jet is judged from the following three viewpoints: 1) with respect to the fineness of atomization; 2) with respect to the direction or distribution of sprayed particles; 3) with respect to the penetration of the particles.

FUELS - TESTS↗

Demonstration of Data Center Energy Use Prediction Software

This report documents a demonstration of a software modeling tool from Romonet that was used to predict energy use and forecast energy use improvements in an operating data center. The demonstration was conducted in a conventional data center with a 15,500 square foot raised floor and an IT equipment load of 332 kilowatts. It was cooled using traditional computer room air handlers and a compressor-based chilled water system. The data center also utilized an uninterruptible power supply system for power conditioning and backup. Electrical energy monitoring was available at a number of locations within the data center. The software modeling tool predicted the energy use of the data center's cooling and electrical power distribution systems, as well as electrical energy use and heat removal for the site. The actual energy used by the computer equipment was recorded from power distribution devices located at each computer equipment row. The model simulated the total energy use in the data center and supporting infrastructure and predicted energy use at energy-consuming points throughout the power distribution system. The initial predicted power levels were compared to actual meter readings and were found to be within approximately 10 percent at a particular measurement point, resulting in a site overall variance of 4.7 percent. Some variances were investigated, and more accurate information was entered into the model. In this case the overall variance was reduced to approximately 1.2 percent. The model was then used to predict energy use for various modification opportunities to the data center in successive iterations. These included increasing the IT equipment load, adding computer room air handler fan speed controls, and adding a water-side economizer. The demonstration showed that the software can be used to simulate data center energy use and create a model that is useful for investigating energy efficiency design changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-I-90: Characterizing Small Animal Lung Properties Using Speckle Observed with An In-Line X-Ray Phase Contrast Benchtop System

Purpose: We demonstrate a novel X-ray phase-contrast (XPC) method for lung imaging representing a paradigm shift in the way small animal functional imaging is performed. In our method, information regarding airway microstructure that is encoded within speckle texture of a single XPC radiograph is decoded to produce 2D parametric images that will spatially resolve changes in lung properties such as microstructure sizes and air volumes. Such information cannot be derived from conventional lung radiography or any other 2D imaging modality. By computing these images at different points within a breathing cycle, dynamic functional imaging will be readily achieved without the need for tomography. Methods: XPC mouse lung radiographs acquired in situ with an in-line X-ray phase contrast benchtop system. The lung air volume is varied and controlled with a small animal ventilator. XPC radiographs will be acquired for various lung air volume levels representing different phases of the respiratory cycle. Similar data will be acquired of microsphere-based lung phantoms containing hollow glass spheres with known distributions of diameters. Image texture analysis is applied to the data to investigate relationships between texture characteristics and airspace/microsphere physical properties. Results: Correlations between Fourier-based texture descriptors (FBTDs) and regional lung air volume indicate that the texture features in 2D radiographs reveal information on 3D properties of the lungs. For example, we find for a 350 × 350 πm2 lung ROI a linear relationship between injected air volume and FBTD value with slope and intercept of 8.9×10{sup 5} and 7.5, respectively. Conclusion: We demonstrate specific image texture measures related to lung speckle features are correlated with physical characteristics of refracting elements (i.e. lung air spaces). Furthermore, we present results indicating the feasibility of implementing the technique with a simple imaging system design, short exposures, and low dose which provides potential for widespread use in laboratory settings for in vivo studies. This research was supported in part by NSF Award CBET1263988.

60 APPLIED LIFE SCIENCES↗

A mathematical model of extremely low frequency ocean induced electromagnetic noise

Magnetic Anomaly Detection (MAD) system uses the principle that ferromagnetic objects disturb the magnetic lines of force of the earth. These lines of force are able to pass through both water and air in similar manners. A MAD system, usually mounted on an aerial vehicle, is thus often employed to confirm the detection and accomplish localization of large ferromagnetic objects submerged in a sea-water environment. However, the total magnetic signal encountered by a MAD system includes contributions from a myriad of low to Extremely Low Frequency (ELF) sources. The goal of the MAD system is to detect small anomaly signals in the midst of these low-frequency interfering signals. Both the Range of Detection (R{sub d}) and the Probability of Detection (P{sub d}) are limited by the ratio of anomaly signal strength to the interfering magnetic noise. In this paper, we report a generic mathematical model to estimate the signal-to-noise ratio or SNR. Since time-variant electro-magnetic signals are affected by conduction losses due to sea-water conductivity and the presence of air-water interface, we employ the general formulation of dipole induced electromagnetic field propagation in stratified media [1]. As a first step we employ a volumetric distribution of isolated elementary magnetic dipoles, each having its own dipole strength and orientation, to estimate the magnetic noise observed by a MAD system. Numerical results are presented for a few realizations out of an ensemble of possible realizations of elementary dipole source distributions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of tunnel sidewall boundary-layer-control systems for high-lift airfoil testing

An experimental study was conducted in the NASA Langley Low-Turbulence Pressure Tunnel to evaluate a suction sidewall boundary-layer-control (BLC) technique used in testing 2D high-lift airfoils. Sidewall BLC is required to maintain spanwise two-dimensionality of the flow over the airfoil at large angles of attack. A supercritical-type high-lift air-foil, equipped with a double-slotted flap and a leading-edge slat, was used for the study which was conducted at a Mach number of 0.2 and Reynolds numbers based on chord of 9 and 16 million. The sidewall BLC technique, which features distributed suction through porous endplates connected to a venting system, was able to control sidewall boundary-layer separation and maintain two-dimensional flow over the high-lift configuration for both Reynolds numbers tested. Discussions on porous endplate optimization and effects of suction on section lift are presented. Results obtained with the suction system were also compared with previous data obtained with a tangential blowing BLC system for the same high-lift configuration.

Paschal, K.↗

Light absorption enhancement of black carbon in a pyrocumulonimbus cloud

Abstract Pyrocumulonimbus (pyroCb) firestorm systems have been shown to inject significant amounts of black carbon (BC) to the stratosphere with a residence time of several months. Injected BC warms the local stratospheric air, consequently perturbing transport and hence spatial distributions of ozone and water vapor. A distinguishing feature of BC-containing particles residing within pyroCb smoke is their thick surface coatings made of condensed organic matter. When coated with non-refractory materials, BC’s absorption is enhanced, yet the absorption enhancement factor ( E abs ) for pyroCb BC is not well constrained. Here, we perform particle-scale measurements of BC mass, morphology, and coating thickness from inside a pyroCb cloud and quantify E abs using an established particle-resolved BC optics model. We find that the population-averaged E abs for BC asymptotes to 2.0 with increasing coating thickness. This value denotes the upper limit of E abs for thickly coated BC in the atmosphere. Our results provide observationally constrained parameterizations of BC absorption for improved radiative transfer calculations of pyroCb events.

54 ENVIRONMENTAL SCIENCES↗

HEMS: Home Energy Management System [SWR-15-12] - Stochastic Optimal Scheduling of Residential Appliances with Renewable Energy Sources

The HEMS algorithm schedules residential appliance operation to minimize the weighted sum of occupant discomfort, total energy cost, peak electricity consumption and carbon footprint, weighted according to occupant preferences. A centralized mixed integer linear programming (MILP) based optimization approach is taken, with the HEMS managing all appliances directly, following a Model Predictive Control (MPC) methodology which determines the optimal schedule over the user-specified scheduling horizon and repeats the optimization at configurable time intervals. The HEMS is developed on the General Algebraic Modeling System (GAMS) using the MILP solver. This system is able to effectively deal with the stochasticity in the distributed system by utilizing Monte Carlo simulation where uncertainties in future electricity price, outdoor temperature, water usage, solar and wind generation can be accounted for. The HEMS controls the operation of the heating, ventilation and air conditioning (HVAC) system, water heater, refrigerator, residential batteries, electric vehicles, standalone micro combined heat and power (CHP) generator, dishwasher, washer/dryer, pool pumps, and lighting.

Pratt, Annabelle↗

VOLTTRON/volttron-pnnl-aems

The Autonomous Energy Management Software (AEMS) system will continuously optimize the operations of the distributed energy resources in the small and medium size commercial building by minimizing energy consumption and cost, while providing a solution for maximizing decarbonization benefits from electrification of buildings. Initially, AEMS system will manage rooftop air conditioners and heat pumps but it can be extended in the future to manage, hot water heaters, storage (battery and thermal), electric vehicle charging and monitoring solar photovoltaic. AEMS support both energy efficiency and grid service features.

Bleeker, Amelia [Pacific Northwest National Labora↗

Effects of coolant parameters on steady state temperature distribution in phospheric-acid fuel cell electrode

The influence of thermophysical properties and flow rate on the steady-state temperature distribution in a phosphoric-acid fuel cell electrode plate was experimentally investigated. An experimental setup that simulates the operating conditions prevailing in a phosphoric-acid fuel cell stack was used. The fuel cell cooling system utilized three types of coolants to remove excess heat generated in the cell electrode and to maintain a reasonably uniform temperature distribution in the electrode plate. The coolants used were water, engine oil, and air. These coolants were circulated at Reynolds number ranging from 1165 to 6165 for water; 3070 to 6864 for air; and 15 to 79 for oil. Experimental results are presented.

Alkasab, K. A.↗

Identifying Human Factors Research for Unmanned Aircraft Systems and Advanced Air Mobility

This paper identifies some of the key human factors (HF) challenges when integrating Unmanned Aircraft Systems (UAS) and Advanced Air Mobility (AAM) into the civil airspace. Unique HF considerations—those which are derived from the key differentiating aspects of UAS/AAM compared to conventional aviation—are the primary basis for identifying HF research opportunities. By identifying what makes UAS and AAM fundamentally different from conventional aviation, from a human integration perspective, HF research can be targeted to effectively inform best practices, standards, policy, guidance, and regulations associated with aircraft and air traffic systems and operations. HF research areas are discussed within the following topic areas: Sustained low-altitude operations; loss of natural sensing; novel aircraft; novel operations; link management and lost link; link performance; distributed pilot teams; and increased automation. The identified research descriptions are intended to serve as illustrative examples of what research is fundamental, and why. They are not intended to prescribe, prioritize or exclude research.

AAM↗

Identifying Human Factors Research for Unmanned Aircraft Systems (UAS) and Advanced Air Mobility (AAM)

This paper identifies some of the key human factors (HF) challenges when integrating Unmanned Aircraft Systems (UAS) and Advanced Air Mobility (AAM) into the civil airspace. Unique HF considerations—those which are derived from the key differentiating aspects of UAS/AAM compared to conventional aviation—are the primary basis for identifying HF research opportunities. By identifying what makes UAS and AAM fundamentally different from conventional aviation, from a human integration perspective, HF research can be targeted to effectively inform best practices, standards, policy, guidance, and regulations associated with aircraft and air traffic systems and operations. HF research areas are discussed within the following topic areas: Sustained low-altitude operations; loss of natural sensing; novel aircraft; novel operations; link management and lost link; link performance; distributed pilot teams; and increased automation. The identified research descriptions are intended to serve as illustrative examples of what research is fundamental, and why. They are not intended to prescribe, prioritize or exclude research.

AAM↗

Compliance Monitoring of Juvenile Yearling Chinook Salmon and Steelhead Survival and Passage at The Dalles Dam, Spring 2010

The purpose of this compliance study was to estimate dam passage survival of yearling Chinook salmon and steelhead smolts at The Dalles Dam during spring 2010. Under the 2008 Federal Columbia River Power System (FCRPS) Biological Opinion (BiOp), dam passage survival should be greater than or equal to 0.96 and estimated with a standard error (SE) less than or equal 0.015. The study also estimated smolt passage survival from the forebay boat-restricted zone (BRZ) to the tailrace BRZ at The Dalles Dam, as well as the forebay residence time, tailrace egress, and spill passage efficiency (SPE), as required in the Columbia Basin Fish Accords. A virtual/paired-release design was used to estimate dam passage survival at The Dalles Dam. The approach included releases of acoustic-tagged smolts above John Day Dam that contributed to the formation of a virtual release at the face of The Dalles Dam. A survival estimate from this release was adjusted by a paired release below The Dalles Dam. A total of 4,298 yearling Chinook salmon and 4,309 steelhead smolts were tagged and released in the investigation. The Juvenile Salmon Acoustic Telemetry System (JSATS) tag model number ATS-156dB, weighing 0.438 g in air, was used in this investigation. The dam passage survival results are summarized as follows: Yearling Chinook Salmon 0.9641 (SE = 0.0096) and Steelhead 0.9535 (SE = 0.0097).

24 POWER TRANSMISSION AND DISTRIBUTION↗

TPSAS-NF1676L-34528-DND

Since 2006, the Cloud-Aerosol Lidar with Orthogonal Polarization (CALIOP), aboard the Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) satellite, has provided a unique vertical perspective of Earth's atmosphere. These measurements have furthered our understanding of the role aerosols and clouds play in the climate system and have been leveraged for atmospheric modeling and air quality studies. In this seminar, the basics of LIDAR remote sensing will first be presented, including its operating principles, setup and geometry, the LIDAR equation, and different LIDAR types and techniques. Next, an overview of the LIDAR systems at NASA Langley Research Center will be provided, with an emphasis on the CALIPSO satellite mission, including available data products and examples of browse images. Lastly, several CALIPSO-based science applications and research projects will be discussed, including cloud contamination in passive satellite aerosol retrievals, aerosol detection limits, trends in aerosol vertical distribution, and air quality (PM2.5 concentrations).