Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Adiabatic Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Towards an Enhanced Droplet Activation Scheme for Multi-Moment Bulk Microphysics Schemes

Initial droplet spectra produced upon activation impact the ensuing chain of microphysical processes andtherefore play a crucial role in cloud evolution. This work re-examines dependencies of newly formed clouddroplet size distribution (CDSD) characteristics on environmental and aerosol properties via parcel model simulationsthat serve as the basis for a multi-moment bulk microphysics droplet activation scheme suitable for acloud-resolving model (CRM). It is found that applying a fixed size threshold to define activated droplets versusemploying physical considerations can lead to erroneous activation and overly broad CDSDs for high aerosolconcentration and weak updraft conditions. Aerosol distributions characterized by larger median sizes and/orincreased solubility can result in greater activated droplet numbers, whereas impacts of these parameters onCDSD spectral width depend on both aerosol number concentration and updraft velocity. An expansion of theactivation scheme to include CDSD spectral width is proposed to aid efforts to extend high-order momentprediction to cloud droplet categories in CRMs as well as better represent variability in the activation process onthe cloud scale.simulations to investigate the regime dependence of the relative dispersion(d)1 of newly activated CDSDs, where d is the ratio of dropletradius standard deviation (σ) to the mean radius (r ). C16 demonstratedthat increasing Na resulted in increasing (decreasing) d values via reducedcondensational narrowing (spectral broadening) rates within theAL (UL) regime, with d values peaking in the TR regime. Their findingssuggest a similar regime dependence for d as R09 noted for Nc and helpexplain reportedly conflicting relationships between Na and CDSDspectral characteristics (cf. Hudson and Noble, 2014; Liu et al., 2014),although the applicability of these results within bulk microphysicalschemes was not addressed.Simulating aerosol-cloud interactions with CRMs employing bulkmicrophysics requires that the scheme minimally predict two CDSDparameters, namely mass and number concentrations, and represent thedroplet activation process. Various activation schemes aim to determineNc from aerosol and environmental properties and include analyticalexpressions (e.g., Abdul-Razzak et al., 1998; Morrison et al., 2005) aswell as lookup tables (LUTs) based on detailed parcel model calculations(e.g., Saleeby and Cotton, 2004, hereafter SC04; Segal and Khain,2006; Thompson and Eidhammer, 2014). Expressions to diagnose CDSDspectral width from Nc (Grabowski, 1998; Liu et al., 2006; Morrison andGrabowski, 2007) or cloud water content (Geoffroy et al., 2010) havealso been developed, although more robust methods to obtain CDSDspectral width upon activation are presently lacking. This latter point isrelevant for triple-moment (3 M) bulk microphysics that aim to predictdistribution spectral width alongside number and mass concentrations(e.g., Loftus et al., 2014; Milbrandt and Yau, 2005).The current work extends the findings of C16 to the current LUTbasedaerosol activation scheme used in the Regional AtmosphericModeling System (RAMS) (Cotton et al., 2003; SC04; Saleeby and vanden Heever, 2013, hereafter SvdH13) and additionally examinesaerosol size and solubility impacts on newly activated CDSD properties.Because early cloud development processes such as condensationalgrowth, evaporation, and droplet self-collection depend on and impactCDSD spectral width (Hudson and Yum, 1997; Seifert and Beheng 2001;Lu and Seinfeld, 2006; Igel and van den Heever, 2017), an expansion ofthe activation LUTs to include CDSD spectral width is proposed as apreliminary step for extending 3M prediction to CDSDs in CRMs forimproved simulations of aerosol-cloud interactions.2. MethodologyThe current RAMS two-moment microphysics module determinesthe fractional number of aerosol particles that activate to cloud dropletsfrom five-dimensional LUTs based on model predicted air temperature(T), w, Na, and the geometric median radius (rg) and soluble fraction (ε)of the aerosol size distribution (SvdH13). These LUTs are created offlineusing a one-dimensional Lagrangian adiabatic parcel model (Feingoldand Heymsfield, 1992; Heymsfield and Sabin, 1989; SC04) to simulateexplicit droplet activation and initial CDSD growth for a range of ambientatmospheric conditions [T, w] and binned lognormal aerosol sizedistributions given by= ⎡⎣ ⎢− ⎤⎦ ⎥N r Nr π σr rσ( )2 lnexp[ln( / )]2(ln )aggg22 (1)where r is the dry aerosol particle bin radius and σg is the geometricstandard deviation of the distribution. As the parcel model simulationsfocus on the activation process, other processes such as coalescence,sedimentation, and mixing are not considered. Details of the parcelmodel can be found in SC04 and SvdH13, and only a brief description isprovided here. At the onset of parcel model calculations, the initiallydry aerosol particles in all bins first deliquesce and reach theirequilibrium diameters in a sub-saturated environment based on theKöhler equation for solution droplets. The parcel is then lifted at a fixedupward velocity w, and particle growth by vapor diffusion, along withconcurrent changes in the ambient environment, are iteratively computedusing the Variable-coefficient Ordinary Differential Equation(VODE) solver (Brown et al., 1989). The time resolution of these calculationsis determined within the VODE solver, and the frequency atwhich the solver is called is controlled by a longer model time stepbased on fixed upward parcel displacement increments (Δz) at thespecified w (Δt=Δz/w). Model calculations proceed until the parcelreaches a height 50m beyond the level of maximum saturation ratio(Smax) or total parcel displacement exceeds 2 km. Upon model termination,Smax and the fractional number of aerosols (factv) resulting innewly formed cloud droplets, defined as particles having diameters of atleast 2 μm, are cataloged in the LUTs according to the specified T, w, Na,rg, and ε parameter values.A critical point regarding the creation of these LUTs is the use of afixed minimum diameter (Dmin) to define cloud droplets in the parcelmodel, which can produce erroneous CDSD characteristics, particularlywithin the UL regime. For aerosol distributions with large rg valuesunder low SS conditions, for example, deliquesced aerosols within thelarge tail of the distribution can exceed 2 μm in diameter yet remainunactivated as ‘haze’ particles (Levin and Cotton, 2009; McFigganset al., 2006). For this study, aerosol particles activate to cloud dropletsbased on the critical diameter Dcrit as a function of parcel supersaturationratio (Sr) as in R09:D = σ MS RTρ83 ln( ) critsol wr w (2)where σsol is the surface tension of a solution droplet, Mw and ρw are themolar mass and density of liquid water, respectively, and R is theuniversal gas constant. Additionally, at relatively large w values withinthe AL regime, Nc stabilizes shortly after reaching supersaturation.However, parcel ascent and condensational growth continue beyondthe level of Smax, potentially causing additional narrowing of the CDSD.In the current work, model calculations terminate upon reaching Smaxas changes in Nc are negligible with continued ascent (Peng et al., 2007;R09).Parcel model simulations are performed to examine the sensitivitiesof CDSD characteristics to w, Na, rg, and ε, with the ranges for theseparameters listed in Table 1. Aerosols are assumed to be a mix of solubleand insoluble material of equal density, specified by ε, where fullysoluble aerosols correspond to ammonium sulfate with hygroscopicityparameter κ=0.61 (Petters and Kreidenweis, 2007). FollowingSvdH13, aerosol geometric standard deviation is fixed at σg=1.8, andaerosol distributions (Eq. 1) are partitioned into 100 logarithmicallyspacedbins spanning a size range specific to each rg value. For all simulations,Δz=1 m, and initial values of relative humidity, air temperatureand pressure are set to RH=0.99, T=10 °C and p=900 hPa,respectively.

Loftus, Adrian M.↗

Cryogenics and Fluids at NASA-Goddard Space Flight Center

Abstract: Spacecraft thermal design presents unique thermal and fluid challenges caused by a variety of harsh spacecraft thermal environments. In addition, at cryogenic temperatures (i.e., less than 123 K (-150° C), and sometimes as low as 50 milliKelvin), more challenges arise, such as the increasing importance of mitigating thermal radiation, the effects of coefficient of thermal expansion mismatches between different materials, changes in the physics behavior of materials, and increasing thermodynamic difficulty of lifting heat up large temperature gradients. In this talk, Dr. Rueger will present a broad overview of spacecraft thermal environments; cryogenic design practices; components of interest for the Cryogenics and Fluids Branch (e.g., cryocoolers, adiabatic demagnetization refrigerators, heat switches, and superconducting leads); cryogenic considerations in some current NASA mission examples (e.g., the DragonFly mission to Titan and the X-ray Imaging and Spectroscopy Mission); and capabilities of the Cryogenics and Fluids Branch at NASA.

Paul Rueger↗

Adiabatic expansion cooling of antihydrogen

Magnetically trapped antihydrogen atoms can be cooled by expanding the volume of the trap in which they are confined. We report a proof-of-principle experiment in which antiatoms are deliberately released from expanded and static traps. Antiatoms escape at an average trap depth of 0.08 ± 0.01 K (statistical errors only) from the expanded trap while they escape at average depths of 0.22 ± 0.01 and 0.17 ± 0.01 K from two different static traps. (We employ temperature-equivalent energy units.) Detailed simulations qualitatively agree with the escape times measured in the experiment and show a decrease of 38 % (statistical error < 0.2 % ) in the mean energy of the population after the trap expansion without significantly increasing antiatom loss compared to typical static confinement protocols. This change is bracketed by the predictions of one-dimensional and three-dimensional semianalytic adiabatic expansion models. These experimental, simulational, and model results are consistent with obtaining an adiabatically cooled population of antihydrogen atoms that partially exchanged energy between axial and transverse degrees of freedom during the trap expansion. This result is important for future antihydrogen gravitational experiments which rely on adiabatic cooling, and it will enable antihydrogen cooling beyond the fundamental limits of laser cooling. Published by the American Physical Society 2024

Ahmadi, M.↗

Observed and Bin Model Simulated Evolution of Drop Size Distributions in High-Based Cumulus Congestus Over the United Arab Emirates

This study examines microphysical processes in developing high-based cumulus congestus over the United Arab Emirates using aircraft observations and a large-eddy-simulation model with bin microphysics. A notable feature of this case is the lack of mm-sized drops despite having a liquid cloud layer >3.5 km deep, contrasting with copious large drops observed in maritime tropical cumulus congestus having a similar vertical extent. Modeled drop size distributions are similar to observations at various temperatures between 9.5 and –12°C, including the lack of mm-sized drops. Cloud dilution leads to low-to-moderate liquid water contents (~0.5–1.5 g m –3 ) in most of the cloud core, several times smaller than adiabatic values. Dilution is enhanced in the inflowing branch of the toroidal circulations associated with individual cloud thermals, which are favored regions for secondary droplet activation (activation above cloud base). Secondary activation in general contributes substantially to the droplet population. Turning it off leads to a sharp decrease in droplet concentration and increase in mean size aloft, but does little to increase rain drop production. Warm rain generation (or lack thereof) in this case is therefore determined more by the sub-cloud aerosol and the cloud base droplet size distribution (DSD) than DSD evolution aloft from secondary droplet activation. Decreasing the aerosol concentration by a factor of 10 greatly increases production of large drops via collision-coalescence. Thus, despite its high base (low temperatures) and substantial dilution, the simulated cloud is thermodynamically and dynamically capable of rapidly producing copious mm-sized drops from collision-coalescence under pristine aerosol conditions.

54 ENVIRONMENTAL SCIENCES↗

Operation of an ADR Using Helium Exchange Gas as a Substitute for a Failed Heat Switch

The Soft X-ray Spectrometer (SXS) is one of four instruments on the Japanese Astro-H mission, which is currently planned for launch in late 2015. The SXS will perform imaging spectroscopy in the soft X-ray band (0.3-12 keV) using a 6 6 pixel array of microcalorimeters cooled to 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR) that rejects heat to either a superfluid helium tank (at 1.2 K) or to a 4.5 K Joule-Thomson (JT) cryocooler. Four gas-gap heat switches are used in the assembly to manage heat flow between the ADR stages and the heat sinks. The engineering model (EM) ADR was assembled and performance tested at NASA/GSFC in November 2011, and subsequently installed in the EM dewar at Sumitomo Heavy Industries, Japan. During the first cooldown in July 2012, a failure of the heat switch that linked the two colder stages of the ADR to the helium tank was observed. Operation of the ADR requires some mechanism for thermally linking the salt pills to the heat sink, and then thermally isolating them. With the failed heat switch unable to perform this function, an alternate plan was devised which used carefully controlled amounts of exchange gas in the dewar's guard vacuum to facilitate heat exchange. The process was successfully demonstrated in November 2012, allowing the ADR to cool the detectors to 50 mK for hold times in excess of 10 h. This paper describes the exchange-gas-assisted recycling process, and the strategies used to avoid helium contamination of the detectors at low temperature.

Adiabatic demagnetization↗

The terrain of evolution of isotropic adiabatic supernova remnants

Models of the evolution of supernova remnants in isotropic media are reviewed and generalized. It is shown that properties of remnants (including cooling and volume-filling aspects) are almost history-independent functions of their instantaneous average density and postshock temperature. These properties, presented as a contour diagram in the density-temperature plane, thus define the territory through which remnant properties evolve. In different models, remnants merely take different paths across the available terrain. For the Milky Way, M101, and the LMC, the portions of this terrain which might actually be sampled by the remnant populations are discussed briefly.

Cox, D. P.↗

Experimental characterization of hot-electron emission and shock dynamics in the context of the shock ignition approach to inertial confinement fusion

We report on planar target experiments conducted on the OMEGA-EP laser facility performed in the context of the shock ignition (SI) approach to inertial confinement fusion. The experiment aimed at characterizing the propagation of strong shock in matter and the generation of hot electrons (HEs), with laser parameters relevant to SI (1-ns UV laser beams with I ~10 16 W/cm 2 ). Time-resolved radiographs of the propagating shock front were performed in order to study the hydrodynamic evolution. The hot-electron source was characterized in terms of Maxwellian temperature, T h , and laser to hot-electron energy conversion efficiency η using data from different x-ray spectrometers. The post-processing of these data gives a range of the possible values for T h and η [i.e., T h [keV] ϵ (20, 50) and η ϵ (2%, 13%)]. These values are used as input in hydrodynamic simulations to reproduce the results obtained in radiographs, thus constraining the range for the HE measurements. According to this procedure, we found that the laser converts ~10% ± 4% of energy into hot electrons with T h = 27 ± 8 keV. The paper shows how the coupling of different diagnostics and numerical tools is required to sufficiently constrain the problem, solving the large ambiguity coming from the post-processing of spectrometers data. The effect of the hot electrons on the shock dynamics is then discussed, showing an increase in the pressure around the shock front. Furthermore, the low temperature found in this experiment without pre-compression laser pulses could be advantageous for the SI scheme, but the high conversion efficiency may lead to an increase in the shell adiabat, with detrimental effects on the implosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alignment Thresholds of Molecules

Molecules have long been known to align in moderately intense, far off-resonance laser fields with a large variety of applications in physics and optics. Here, we illustrate and describe the physical origin of a previously unexplored phenomenon in the adiabatic alignment dynamics of molecules, which is fundamentally interesting and also has an important practical implication. Specifically, the intensity dependence of the degree of adiabatic alignment exhibits a threshold behavior, below which molecules are isotropically distributed rotationally and above which the alignment rapidly reaches a plateau. Furthermore, we show that both the intensity and the temperature dependencies of the alignment of all linear molecules exhibit universal curves and derive analytical forms to describe these dependencies. Finally, we illustrate that the alignment threshold occurs very generally at a lower intensity than the off-resonance ionization threshold, a numerical observation that is readily illustrated analytically. The threshold behavior is attributed to a tunneling mechanism that rapidly switches off at the threshold intensity, where tunneling between the potential wells corresponding to the two orientations of the aligned molecules becomes impossible. The universal threshold behavior of molecular alignment is a simple phenomenon, but one that was not realized before and can be readily tested experimentally.

74 ATOMIC AND MOLECULAR PHYSICS↗

Generalized Lapse Rate Formulas for Use in Entraining CAPE Calculations

Abstract Common assumptions in temperature lapse rate formulas for lifted air parcels include neglecting mixing, hydrostatic balance, the removal of all condensate once it forms (pseudoadiabatic), and/or the retention of all condensate within the parcel (adiabatic). These formulas are commonly derived from the conservation of entropy, which leads to errors when nonequilibrium mixed-phase condensate is present. To evaluate these assumptions, a new general lapse rate formula is derived from an expression for energy conservation, rather than entropy conservation. This new formula incorporates mixing of the parcel with its surroundings, relaxes the hydrostatic assumption, allows for nonequilibrium mixed-phase condensate, and can be formulated for pseudoadiabatic or adiabatic ascent. The new formula is shown to exactly conserve entropy for reversible ascent. Predictions by the new formula are compared to that of older and less general formulas. The errors in previous formulas arise from the assumption of hydrostatic balance, which results in considerable warm biases due to the neglect of the energy sink from buoyancy. Predictions of ascent with entrainment using the new formula are then compared to parcel properties along trajectories in large eddy simulations. Simulated parcel properties are better predicted by the formula using a diluted analogy to adiabatic ascent, wherein condensate is diluted at the same rate as other parcel properties, than by the diluted analogy to pseudoadiabatic ascent, wherein all condensate is removed. These results suggest that CAPE should be computed with adiabatic, rather than pseudoadiabatic, parcel ascent.

54 ENVIRONMENTAL SCIENCES↗

Structure of the atmosphere of Venus up to 110 kilometers - Preliminary results from the four Pioneer Venus entry probes

Each of the four Pioneer Venus probes carried instruments to measure the structure of the atmosphere, both below the cloud deck and above it to an altitude of at least 120 km. Preliminary results are presented on lower-atmosphere structure, thermal contrasts, and atmospheric stability. Altitudes derived from the data are given along with the temperature profile from 67 to 105 km, derived from the first analysis of the entry data from the north probe. All four probes lost temperature data at the 640 K level, which is at an altitude of about 12 to 14 km. Values of temperature and pressure at touchdown are presented in a table. The pressure differences imply terrain elevation differences at the landing sites. Above 40 km, the measured profile moves from near-adiabatic toward the theoretical profile for radiative equilibrium.

Seiff, A.↗

Thermal shaft effects on load-carrying capacity of a fully coupled, variable-properties cryogenic journal bearing

The purpose of this work was to perform a rather complete analysis for a cryogenic (oxygen) journal bearing. The Reynolds equation required coupling and simultaneous solution with the fluid energy equation. To correctly account for the changes in the fluid viscosity, the fluid energy equation was coupled with the shaft and bearing heat conduction energy equations. The effects of pressure and temperature on the density, viscosity, and load-carrying capacity were further discussed as analysis parameters, with respect to relative eccentricity and the angular velocity. The isothermal fluid case and the adiabatic fluid case represented the limiting boundaries. The discussion was further extrapolated to study the Sommerfeld number dependency on the fluid Nusselt number and its consequence on possible total loss of load-carrying capacity and/or seizure (catastrophic failure).

Braun, M. J.↗

5-year lifetime hybrid superfluid helium dewar for the AXAF X-Ray Spectrometer (XRS)

The focal plane of the AXAF X-Ray Spectrometer requires an operating temperature of 0.1 K with a mission lifetime of 5 yrs. This demanding task is accomplished with a hybrid cryogenic subsystem consisting of mechanical coolers, a superfluid helium dewar and an adiabatic demagnetization refrigerator. By using mechanical coolers to remove heat from the dewar outer vapor-cooled shield, a 5-yr lifetime is achievable with only a 483-liter tank. This approach takes advantage of flight-proven, high-performance dewar technology and recent success in the development of split, Stirling-cycle mechanical coolers. Although the dewar design principles are similar to those used previously, parasitic heat flow is reduced to a new level by an optimized tension strap support system and careful attention to insulation system details. The benefit of the mechanical coolers is maximized by dewar interface design features that minimize parasitic heating and thermal impedance of the coupling. The dewar design and thermal performance analysis are discussed. Helium lifetime sensitivities and the effects of mechanical cooler failures are predicted.

Nieczkoski, Stephen J.↗

Aerodynamic Performance of a Supersonic Throughflow Fan Stage With a Convergent Flow Path

The results from an experimental evaluation of a supersonic throughflow (SSTF) fan stage with a convergent flow path are presented. The stage was designed for a pressure ratio of 2.46 at a tip speed of 1350 ft/s and an inlet Mach number 2.00. The stage was tested with flows at subsonic and supersonic inlet axial Mach numbers and with rotor speeds from 40 to 110 percent of design speed. The fan stage overall performance characteristics, as well as details of its performanc characteristics downstream of the stator vanes, are presented. These measurements were obtained with radially and circumferentially traversing probes. At the design condition, the measured overall pressure ratio was 2.366, and the corresponding adiabatic efficiency was 0.610. Transition from subsonic to supersonic flow was demonstrated at 80, 100 and 110 percent of design speed. At the design condition, the radial distribution of energy addition (temperature ratio) from the computational fluid dynamics (CFD) calculations is in excellent agreement with the measured values. The predicted pressure distributions agree reasonably well with those measured.

Royce D. Moore↗

Self-Consistent Superthermal Electron Effects on Plasmaspheric Refilling

The effects of self-consistently including superthermal electrons in the definition of the ambipolar electric field are investigated for the case of plasmaspheric refilling after a geomagnetic storm. By using the total electron population in the hydrodynamic equations, a method for incorporating superthermal electron parameters in the electric field and electron temperature calculation is developed. Also, the ambipolar electric field is included in the kinetic equation for the superthermal electrons through a change of variables using the total energy and the first adiabatic invariant. Calculations based on these changes are performed by coupling time-dependent models of the thermal plasma and superthermal electrons. Results from this treatment of the electric field and the self-consistent development of the solution are discussed in detail. Specifically, there is a decreased thermal electron density in the plasmasphere during the first few minutes of refilling, a slightly accelerated proton shock front, and a decreased superthermal electron flux due to the deceleration by the electric field. The timescales of plasmaspheric refilling are discussed and determined to be somewhat shorter than previously calculated for the thermal plasma and superthermal electron population due to the effects of the field-aligned potential.

Liemohn, M. W.↗

Progress on Computational Modeling of Water-Based NSTF (FY2021)

This report documents the FY21 progress and achievements made in the computational analyses of the water-based NSTF. Both system-level and high-fidelity Computational Fluid Dynamics (CFD) analyses were performed to gain a complete understanding of the complex flow and heat transfer phenomena in natural convection systems. The progress on the waterbased NSTF experimental testing is summarized in a companion report (ANL-ART-230). As a continuation of progress from previous years, in FY21 the RELAP5 model of the NSTF was first updated to include a representative heated cavity that incorporated convection and conduction means of heat transfer. Two different cavity models were developed, one that models the radiation heat exchange among all surfaces in one enclosure (Cavity Model 1), and another that employs multiple radiation enclosures with each considering the surfaces at one axial level (Cavity Model 2). This updated RELAP5 deck was benchmarked with single-phase test data to tune form loss coefficients of the elbows and tees, along with heat transfer coefficients within the cavity and off the external insulation panels. This tuned model was then found to accurately predict fluid temperatures within 2.5% and both system and riser flow rates within 6% during single-phase, steady-state simulations. For transient simulations, there is a slight over prediction of the flow rate, fluid temperatures, and heater temperatures during the heat-up period, which indicate that the transient heat loss may be underestimated. Following, the capabilities of RELAP5-3D were examined, which feature a conduction enclosure model that is not present in the current version of RELAP5-MOD3.3 used for all previous NSTF simulations. As an initial comparison of the two codes, single-phase simulations were run that used similar input decks. The results indicate that the single-phase flow predicted by the two codes was very similar, however RELAP5-3D appears to predict a higher system flow during the two-phase transient when compared to the flow rates predicted by RELAP5-MOD3.3. Furthermore, RELAP5-3D run did not capture the density wave oscillations or geysering phenomena, which are large oscillation flow instabilities observed in the experimental facility. To further the prediction capabilities for capturing two-phase instabilities, Options 55, 57, 58, 61, which are implemented by default in RELAP5-MOD3.3 but not in RELAP5-3D, were investigated. When enabling Option 61, RELAP5-3D agrees well with MOD3.3 in predicting the total system flow, while other options have negligible effect on the predicted total system flow by RELAP5-3D. However, none of these options enables RELAP5-3D to produce the same flow instabilities. For future steps, efforts are currently underway to investigate RELAP5-3D’s different behavior in predicting low-pressure two-phase instabilities. STAR-CCM+ was used to perform CFD analysis of the water-based test facility and provide simulation results for comparisons to experimental data. Efforts first focused on describing the characteristics of flow within the heated cavity. A study was performed on whether possible leakage flow between the two sides of the cavity could substantially impact and explain the results. An additional second assumption was examined which defined adiabatic side walls, so physical insulation structures were added to the models to allow conduction across this outer insulation. The results suggest that potential porosity of the insulation could be a major factor in the temperature distribution within the cavity and should be considered in any studies where it is desirable to know the cavity wall temperatures to higher accuracy.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase diagram to demarcate supercritical, transcritical, and continuous phase regimes for binary fluid equilibrium mixing relevant to combustion applications

Here, a robust methodology to develop phase diagrams of binary fluid mixtures at fixed thermo dynamic conditions (pressure, temperature, and mole fraction) as well as of two initially separated fluids undergoing mixing near critical conditions are presented for fluids and con ditions relevant to rockets, gas turbines, and diesel engine applications. Phase equilibria of mixtures is first examined to provide insight into the continuous-phase mixing behavior (including but not limited to supercritical behavior), and to develop a broadly applicable phase-diagram for binary fluid mixtures at fixed conditions. Next, adiabatic mixing theory and reduced Helmholtz equations of state are used to predict the thermodynamic conditions required to attain continuous-phase binary fluid mixing near critical conditions. Then, a 3D surface diagram (P,T fuel ,T amb ) separating single and two-phase regions is constructed by varying the ambient pressure and the initial temperatures of the two fluids. Polynomial fits of the 3D surfaces for 10 different binary mixtures are tabulated for nitrogen-alkane and methane-oxygen blends relevant to air-breathing and propellant based engines, respectively.

42 ENGINEERING↗

Verification of an improved equation-free projective integration method for neoclassical plasma-profile evolution in tokamak geometry

A brute-force, long-time gyrokinetic simulation of plasma profile evolution in magnetic fusion devices is not desirable due to large computational resource requirements and a possible accumulation of numerical error. The equation-free projective integration method of Keverekidis et al. [Commun. Math. Sci. 1(4), 715–762 (2003)] is one of the outstanding candidates in projecting micro-scale simulations to a longer timescale. However, its application to tokamak plasma has not been fruitful due to the appearance of spurious transient oscillations in the lifting process, which are present when the kinetic simulations are initialized with a simplified model distribution function and which make the kinetic simulations to deviate from the desired paths. In this work, a kinetically informed lifting algorithm is added to the equation-free projective integration method, which is then verified in the electrostatic gyrokinetic particle-in-cell code XGCa [R. Hager and C. S. Chang, Phys. Plasmas 23, 042503 (2016)] for a neoclassical ion heat transport problem with adiabatic electrons. This new lifting operator is demonstrated to control spurious transients, enabling an over four-times reduction in the overall computing time in the time-evolution of the ion temperature profile in an axisymmetric toroidal plasma. Further reduction in the computing time is found to be limited due to the stability properties of the linear least squares projective integrator.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The early evolution of the solar system

The problems of relating collapse conditions in an interstellar cloud to a model of the primitive solar nebula are discussed. In such a nebula there is a radial force balance between gravity, the pressure gradient, and centrifugal forces due to the rotation. Approximate values are given for the combinations of temperature and density throughout the nebula, from a maximum of about 2000 K near the center to less than 200 K in the outer portion. These conditions are based upon the compression adiabats in the terminal stages of the collapse of an interstellar cloud. One general conclusion, of great importance for accumulation of bodies within the solar system, is that interstellar grains should not be completely evaporated at distances in the nebula beyond about one or more astronomical units.

Cameron, A. G. W.↗