Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Accelerators, Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Time-resolved soft x-ray absorption setup using multi-bunch operation modes at synchrotrons

Here, we report on a novel experimental apparatus for performing time-resolved soft x-ray absorption spectroscopy in the sub-ns time scale using non-hybrid multi-bunch mode synchrotron radiation. The present setup is based on a variable repetition rate Ti:sapphire laser (pump pulse) synchronized with the {approx}500 MHz x-ray synchrotron radiation bunches and on a detection system that discriminates and singles out the significant x-ray photon pulses by means of a custom made photon counting unit. The whole setup has been validated by measuring the time evolution of the L{sub 3} absorption edge during the melting and the solidification of a Ge single crystal irradiated by an intense ultrafast laser pulse. These results pave the way for performing synchrotron time-resolved experiments in the sub-ns time domain with variable repetition rate exploiting the full flux of the synchrotron radiation.

43 PARTICLE ACCELERATORS↗

Use of the focusing multi-slit ion optical system at RUssian Diagnostic Injector (RUDI)

The upgrade of the diagnostic neutral beam injector RUDI in 2010 was performed to increase the beam density at the focal plane in accordance with the requirements of charge-exchange recombination spectroscopy diagnostics. A new focusing ion-optical system (IOS) with slit beamlets and an enlarged aperture was optimized for 50% higher nominal beam current and reduced angular divergence with respect to the previous multi-aperture IOS version. The upgraded injector provides the beam current up to 3 A, the measured beam divergence in the direction along the slits is 0.35 deg. Additionally, the plasma generator was modified to extend the beam pulse to 8 s.

43 PARTICLE ACCELERATORS↗

Improvement of efficiency and temperature control of induction heating vapor source on electron cyclotron resonance ion source

An electron cyclotron resonance ion source (ECRIS) is used to generate multicharged ions for many kinds of the fields. We have developed an evaporator by using induction heating method that can generate pure vapor from solid state materials in ECRIS. We develop the new matching and protecting circuit by which we can precisely control the temperature of the induction heating evaporator. We can control the temperature within {+-}15 deg. C around 1400 deg. C under the operation pressure about 10{sup -4} Pa. We are able to use this evaporator for experiment of synthesizing process to need pure vapor under enough low pressure, e.g., experiment of generation of endohedral Fe-fullerene at the ECRIS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion energy distribution functions of low energy beams formed by wire extraction electrodes

The two-electrode extractor system made of 0.1 mm diameter tungsten wires separated by 0.7 mm has formed an argon ion beam with 50 V extraction potential. Energy spreads of the extracted beams were typically less than 2 eV when the beam current density was low. The beam intensity rapidly decreased as the distance between the extractor and the beam detector increased, indicating space charge limited transport of the beam. Problems associated with the emittance measurements are also discussed.

43 PARTICLE ACCELERATORS↗

The on-line charge breeding program at TRIUMF's Ion Trap For Atomic and Nuclear Science for precision mass measurements

TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) constitutes the only high precision mass measurement setup coupled to a rare isotope facility capable of increasing the charge state of short-lived nuclides prior to the actual mass determination in a Penning trap. Recent developments around TITAN's charge breeder, the electron beam ion trap, form the basis for several successful experiments on radioactive isotopes with half-lives as low as 65 ms and in charge states as high as 22+.

43 PARTICLE ACCELERATORS↗

One-shot spectrometer for several elements using an integrated conical crystal analyzer

Time-resolved x-ray spectrometry using an ultrastrong x-ray source such as an x-ray free electron laser is one of the new trends in the field of x-ray physics. To achieve such time-resolved measurement, the development of an one-shot spectrometer with a wide wavelength range, high efficiency, and good energy resolution is an essential prerequisite. Here we developed an integrated conical Ge crystal analyzer consisting of several conical rings, which were connected using spline surfaces to form a single body using our previously developed hot deformation technique, which can form a Si or Ge wafer into an arbitrary and accurate shape. We simultaneously focused several characteristic lines from an alloy sample onto different positions on a small x-ray charge-coupled device with very high image brightness (gain relative to planar analyzer: 100) and a good spatial resolution of 9-13 eV. The small radius of curvature of the crystal (28-50 mm) enabled us to realize a very short sample-detector distance of 214.4 mm. The present result shows the possibility of realizing a new focusing x-ray crystal spectrograph that can control the focal position as desired.

43 PARTICLE ACCELERATORS↗

Versatile high-repetition-rate phase-locked chopper system for fast timing experiments in the vacuum ultraviolet and x-ray spectral region

A novel light chopper system for fast timing experiments in the vacuum-ultraviolet (VUV) and x-ray spectral region has been developed. It can be phase-locked and synchronized with a synchrotron radiation storage ring, accommodating repetition rates in the range of {approx}8 to {approx}120 kHz by choosing different sets of apertures and subharmonics of the ring frequency (MHz range). Also the opening time of the system can be varied from some nanoseconds to several microseconds to meet the needs of a broad range of applications. Adjusting these parameters, the device can be used either for the generation of single light pulses or pulse packages from a microwave driven, continuous He gas discharge lamp or from storage rings which are otherwise often considered as quasi-continuous light sources. This chopper can be utilized for many different kinds of experiments enabling, for example, unambiguous time-of-flight (TOF) multi-electron coincidence studies of atoms and molecules excited by a single light pulse as well as time-resolved visible laser pump x-ray probe electron spectroscopy of condensed matter in the valence and core level region.

43 PARTICLE ACCELERATORS↗

Note: Voltage and intensity dependence of the saturation curves of free-air ionization chambers irradiated with chopped synchrotron radiation beams

Current saturation characteristics of free-air ionization chambers with electrode gaps of 4.2 and 8.4 mm were investigated using pulsed photon beam obtained by periodically interrupting synchrotron radiation beams with a chopper. Pulsed photon beams of 10 and 15 keV with pulse duration of 2.5 {mu}s and a frequency of 230 Hz were produced by chopping the beam. The measured recombination rate was found to be proportional to the intensity and inversely proportional to the applied voltage.

43 PARTICLE ACCELERATORS↗

Ultrahigh resolution soft x-ray emission spectrometer at BL07LSU in SPring-8

An extremely high resolution flat field type slit less soft x-ray emission spectrometer has been designed and constructed for the long undulator beamline BL07LSU in SPring-8. By optimizing the ruling parameters of two cylindrical gratings, a high energy resolution {Delta}E < 100 meV and/or an E/{Delta}E{approx} 10 000 are expected for the energy range of 350 eV - 750 eV taking into account the broadening by the spatial resolution (25 {mu}m) of a CCD detector. A coma-free operation mode proposed by Strocov et al., is also applied to eliminate both defocus and coma aberrations. The spectrometer demonstrated experimentally that E/{Delta}E= 10 050 and 8046 for N 1s (402.1 eV) and Mn 2p (641.8 eV) edges, respectively.

43 PARTICLE ACCELERATORS↗

Asymmetric-cut variable-incident-angle monochromator

A novel asymmetric-cut variable-incident-angle monochromator was constructed and tested in 1997 at the Advanced Photon Source of Argonne National Laboratory. The monochromator was originally designed as a high heat load monochromator capable of handling 5-10 kW beams from a wiggler source. This was accomplished by spreading the x-ray beam out on the surface an asymmetric-cut crystal and by using liquid metal cooling of the first crystal. The monochromator turned out to be a highly versatile monochromator that could perform many different types of experiments. The monochromator consisted of two 18 deg. asymmetrically cut Si crystals that could be rotated about 3 independent axes. The first stage ({Phi}) rotates the crystal around an axis perpendicular to the diffraction plane. This rotation changes the angle of the incident beam with the surface of the crystal without changing the Bragg angle. The second rotation ({Psi}) is perpendicular to the first and is used to control the shape of the beam footprint on the crystal. The third rotation ({Theta}) controls the Bragg angle. Besides the high heat load application, the use of asymmetrically cut crystals allows one to increase or decrease the acceptance angle for crystal diffraction of a monochromatic x-ray beam and allows one to increase or decrease the wavelength bandwidth of the diffraction of a continuum source like a bending-magnet beam or a normal x-ray-tube source. When the monochromator is used in the doubly expanding mode, it is possible to expand the vertical size of the double-diffracted beam by a factor of 10-15. When this was combined with a bending magnet source, it was possible to generate an 8 keV area beam, 16 mm wide by 26 mm high with a uniform intensity and parallel to 1.2 arc sec that could be applied in imaging experiments.

43 PARTICLE ACCELERATORS↗

Lifetime measurements in an electrostatic ion beam trap using image charge monitoring

A technique for mass-selective lifetime measurements of keV ions in a linear electrostatic ion beam trap is presented. The technique is based on bunching the ions using a weak RF potential and non-destructive ion detection by a pick-up electrode. This method has no mass-limitation, possesses the advantage of inherent mass-selectivity, and offers a possibility of measuring simultaneously the lifetimes of different ion species with no need for prior mass-selection.

43 PARTICLE ACCELERATORS↗

Design and performance of a versatile curved-crystal spectrometer for high-resolution spectroscopy in the tender x-ray range

A complete in-vacuum curved-crystal x-ray emission spectrometer in Johansson geometry has been constructed for a 2-6 keV energy range with sub natural line-width energy resolution. The spectrometer is designed to measure x-ray emission induced by photon and charged particle impact on solid and gaseous targets. It works with a relatively large x-ray source placed inside the Rowland circle and employs position sensitive detection of diffracted x-rays. Its compact modular design enables fast and easy installation at a synchrotron or particle accelerator beamline. The paper presents main characteristics of the spectrometer and illustrates its capabilities by showing few selected experimental examples.

43 PARTICLE ACCELERATORS↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

Source fabrication and lifetime for Li{sup +} ion beams extracted from alumino-silicate sources

A space-charge-limited beam with current densities (J) exceeding 1 mA/cm{sup 2} have been measured from lithium alumino-silicate ion sources at a temperature of {approx}1275 deg. C. At higher extraction voltages, the source appears to become emission limited with J{>=} 1.5 mA/cm{sup 2}, and J increases weakly with the applied voltage. A 6.35 mm diameter source with an alumino-silicate coating, {<=}0.25 mm thick, has a measured lifetime of {approx}40 h at {approx}1275 deg. C, when pulsed at 0.05 Hz and with pulse length of {approx}6 {mu}s each. At this rate, the source lifetime was independent of the actual beam charge extracted due to the loss of neutral atoms at high temperature. The source lifetime increases with the amount of alumino-silicate coated on the emitting surface, and may also be further extended if the temperature is reduced between pulses.

43 PARTICLE ACCELERATORS↗

Diamond detector for high rate monitors of fast neutrons beams

A fast neutron detection system suitable for high rate measurements is presented. The detector is based on a commercial high purity single crystal diamond (SDD) coupled to a fast digital data acquisition system. The detector was tested at the ISIS pulsed spallation neutron source. The SDD event signal was digitized at 1 GHz to reconstruct the deposited energy (pulse amplitude) and neutron arrival time; the event time of flight (ToF) was obtained relative to the recorded proton beam signal t{sub 0}. Fast acquisition is needed since the peak count rate is very high ({approx}800 kHz) due to the pulsed structure of the neutron beam. Measurements at ISIS indicate that three characteristics regions exist in the biparametric spectrum: i) background gamma events of low pulse amplitudes; ii) low pulse amplitude neutron events in the energy range E{sub dep}= 1.5-7 MeV ascribed to neutron elastic scattering on {sup 12}C; iii) large pulse amplitude neutron events with E{sub n} < 7 MeV ascribed to {sup 12}C(n,{alpha}){sup 9}Be and 12C(n,n')3{alpha}.

43 PARTICLE ACCELERATORS↗

Indus synchrotron source: A national facility

Indus Synchrotron Radiation complex at Raja Ramanna Centre for Advanced Technology at Indore, India houses two synchrotron radiation sources: Indus-1 and Indus-2 respectively. Indus-1 is a 450 MeV source emitting in VUV and soft x-ray region and operating at 100 mA since 1990 and Indus-2, designed for 2.5 GeV, 300 mA and is currently operating at 2 GeV and 100 mA. Indus-1 has five operational beamlines while Indus-2 has six beamlines installed and operational. Several materials research related problems have been investigated using the reflectivity and photo-electron spectroscopy beamlines at Indus-1 and also the beamlines at Indus-2. Here we will report the current status of both these sources and discuss a few of our studies carried out using these beamlines.

43 PARTICLE ACCELERATORS↗

Neutron beam imaging at neutron spectrometers at Dhruva

A low efficiency, 2-Dimensional Position Sensitive Neutron Detector based on delay line position encoding is developed. It is designed to handle beam flux of 10{sup 6}-10{sup 7} n/cm{sup 2}/s and for monitoring intensity profiles of neutron beams. The present detector can be mounted in transmission mode, as the hardware allows maximum neutron transmission in sensitive region. Position resolution of 1.2 mm in X and Y directions, is obtained. Online monitoring of beam images and intensity profile of various neutron scattering spectrometers at Dhruva are presented. It shows better dynamic range of intensity over commercial neutron camera and is also time effective over the traditionally used photographic method.

43 PARTICLE ACCELERATORS↗

Optimization of drift bias in an UHV based pulsed positron beam system

We report here the design of ultra high vacuum (UHV) compatible pulsed positron beam lifetime system, which combines the principles of a conventional slow positron beam and RF based pulsing scheme. The mechanical design and construction of the UHV system to house the beam has been completed and it has been tested for a vacuum of {approx} 10{sup -10} mbar. The voltages applied to the drift tube as a function of positron energies have been optimized using SIMION.

43 PARTICLE ACCELERATORS↗