Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ARTIFACTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Triple ion beam cutting of diamond/Al composites for interface characterization

A novel triple ion beam cutting technique was employed to prepare high-quality surfaces of diamond/Al composites for interfacial characterization, which has been unachievable so far. Near-perfect and artifact-free surfaces were obtained without mechanical pre-polishing. Hence, the as-prepared surfaces are readily available for further study and also, ready to be employed in a focus ion beam system for preferential selection of transmission electron microscopy samples. Dramatically different diamond/Al interface configurations — sub-micrometer Al{sub 2}O{sub 3} particles and clean interfaces were unambiguously revealed. - Highlights: • A new triple ion beam technique was employed to prepare diamond/Al composites. • Near-perfect and artifact-free surfaces were obtained for interface characterization. • Sub-micrometer Al{sub 2}O{sub 3} particles and clean interfaces were unambiguously revealed.

36 MATERIALS SCIENCE↗

Comparison of Computed Tomography Scout Based Reference Point Localization to Conventional Film and Axial Computed Tomography

Identification of source positions after implantation is an important step in brachytherapy planning. Reconstruction is traditionally performed from films taken by conventional simulators, but these are gradually being replaced in the clinic by computed tomography (CT) simulators. The present study explored the use of a scout image-based reconstruction algorithm that replaces the use of traditional film, while exhibiting low sensitivity to metal-induced artifacts that can appear in 3D CT methods. In addition, the accuracy of an in-house graphical software implementation of scout-based reconstruction was compared with seed location reconstructions for 2 phantoms by conventional simulator and CT measurements. One phantom was constructed using a planar fixed grid of 1.5-mm diameter ball bearings (BBs) with 40-mm spacing. The second was a Fletcher-Suit applicator embedded in Styrofoam (Dow Chemical Co., Midland, MI) with one 3.2-mm-diameter BB inserted into each of 6 surrounding holes. Conventional simulator, kilovoltage CT (kVCT), megavoltage CT, and scout-based methods were evaluated by their ability to calculate the distance between seeds (40 mm for the fixed grid, 30-120 mm in Fletcher-Suit). All methods were able to reconstruct the fixed grid distances with an average deviation of <1%. The worst single deviations (approximately 6%) were exhibited in the 2 volumetric CT methods. In the Fletcher-Suit phantom, the intermodality agreement was within approximately 3%, with the conventional sim measuring marginally larger distances, with kVCT the smallest. All of the established reconstruction methods exhibited similar abilities to detect the distances between BBs. The 3D CT-based methods, with lower axial resolution, showed more variation, particularly with the smaller BBs. With a software implementation, scout-based reconstruction is an appealing approach because it simplifies data acquisition over film-based reconstruction without requiring any specialized equipment and does not carry risk of misreads caused by artifacts.

61 RADIATION PROTECTION AND DOSIMETRY↗

An analysis of the nucleon spectrum from lattice partially-quenched QCD.

The chiral extrapolation of the nucleon mass, M{sub n}, is investigated using data coming from 2-flavour partially-quenched lattice simulations. A large sample of lattice results from the CP-PACS Collaboration is analysed using the leading one-loop corrections, with explicit corrections for finite lattice spacing artifacts. The extrapolation is studied using finite-range regularised chiral perturbation theory. The analysis also provides a quantitative estimate of the leading finite volume corrections. It is found that the discretisation, finite volume and partial quenching effects can all be very well described in this framework, producing an extrapolated value of Mn in agreement with experiment. Furthermore, determinations of the low energy constants of the nucleon mass's chiral expansion are in agreement with previous methods, but with significantly reduced errors. This procedure is also compared with extrapolations based on polynomial forms, where the results are less encouraging.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correcting nonlinear drift distortion of scanning probe and scanning transmission electron microscopies from image pairs with orthogonal scan directions

Unwanted motion of the probe with respect to the sample is a ubiquitous problem in scanning probe and scanning transmission electron microscopies, causing both linear and nonlinear artifacts in experimental images. We have designed a procedure to correct these artifacts by using orthogonal scan pairs to align each measurement line-by-line along the slow scan direction, by fitting contrast variation along the lines. We demonstrate the accuracy of our algorithm on both synthetic and experimental data and provide an implementation of our method.

36 MATERIALS SCIENCE↗

Image registration of low signal-to-noise cryo-STEM data

Combining multiple fast image acquisitions to mitigate scan noise and drift artifacts has proven essential for picometer precision, quantitative analysis of atomic resolution scanning transmission electron microscopy (STEM) data. For very low signal-to-noise ratio (SNR) image stacks – frequently required for undistorted imaging at liq- uid nitrogen temperatures – image registration is particularly delicate, and standard approaches may either fail, or produce subtly specious reconstructed lattice images. We present an approach which effectively registers and averages image stacks which are challenging due to their low-SNR and propensity for unit cell misalignments. Registering all possible image pairs in a multi-image stack leads to significant information surplus. In combination with a simple physical picture of stage drift, this enables identi cation of incorrect image registrations, and determination of the optimal image shifts from the complete set of relative shifts. Here, we demonstrate the effectiveness of our approach on experimental, cryogenic STEM datasets, highlighting subtle artifacts endemic to low-SNR lattice images and how they can be avoided. High-SNR average images with information transfer out to 0.72 Å are achieved at 300 kV and with the sample cooled to near liquid nitrogen temperature.

47 OTHER INSTRUMENTATION↗

The effect of scanning jitter on geometric phase analysis in STEM images

Geometric phase analysis (GPA) is a useful method to map strain distribution in atomically resolved scanning/transmission electron microscopy (S/TEM) images. Nevertheless, the inevitable periodic jitter of electron probe in STEM along the scanning direction due to the interference of electric power supply, including grounding, can give rise to major artifacts, as evidenced by the appearance of satellite spots surrounding all main peaks in the power spectrum of the images. Here we reveal the origin of the image artifacts related to the probe jitter by mapping the image distortion component εxx using the GPA algorithm. The effect is verified by introducing a periodic displacement field to a STEM image simulated from a perfect crystal structure, and the calculated εxx maps show very good agreement with the experimental observations. Based on the quantitative analysis of the images distortion, we propose and test a feasible strategy to eliminate the effect of probe jitter from STEM images. Successful examples illustrate that the approach can help improve the accuracy in quantification of STEM images.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Toward accurate measurement of electromagnetic field by retrieving and refining the center position of non-uniform diffraction disks in Lorentz 4D-STEM

Recent advancement in scanning transmission electron microscopy (STEM) allows the use of 4D-STEM, a technique that captures an electron diffraction pattern at each scan point in STEM, to measure electrostatic and magnetic potential and field in materials. However, accurate measurement, separation of the magnetic and electric signals, and removal of artifacts remain challenging, especially in the presence of complex non-uniform diffraction contrast within the disks. In this work, based on dynamic simulations of 4D-STEM patterns built upon superstructures consisting of millions of atoms to account for different sample thickness and edge geometries, we show how the shape and intensity distribution of the central disk are affected by multiple scattering. We propose a robust refinement procedure through iteration of the spin-sensitive peak position of the disk-center in the circular Hough transform filtered images from experimental Lorentz 4D-STEM dataset after minimizing the possible artifacts, such as those due to the change of thickness, dynamic scattering, and scanning process. We verify that caution must be taken as in practice the rigid-disk-shift model used to reconstruct induction maps can easily break down due to disk-protrusion when there exists a nonconstant phase gradient or thickness within the width of the probe. Through quantitative analysis and comparing experiment with calculation the effect of the non-spin-related intensity distribution inside the disk as well as that causes the disk shift due to the intensity-protrusion can be removed, and high-quality magnetic field mapping is possible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A Level Set Evaporation Model for Heterogeneous Atom Probe Tip

With the development of local electrode atom probe tomography (LEAP), the materials systems feasible for atomic structure determination has expanded from predominantly metals to include heterogeneous materials with complex structure and compositions. This makes the 3D atomic structure determination possible for most energy materials in battery, fuel cell, semiconductor, and nuclear applications. Atom probe tomography (APT) has been utilized to study multiphase materials with segregation and interface problems. The unique and quantitative information retrieved from APT can provide a foundation for the study of kinetic pathways, nanoscale composition mapping, multilayer interfacial segregation, dislocations and grain boundaries. However, a new challenge surfaces when the materials systems expand into heterogeneous materials: the traditional structure reconstruction introduces false magnification and large artifacts due to the underlying assumption of uniform and isotropic evaporation.

Atom probe, heterogeneous structure, evporation mo↗

High-Resolution Field Emission Scanning Electron Microscopy (FESEM) Imaging of Cellulose Microfibril Organization in Plant Primary Cell Walls

Abstract We have used field emission scanning electron microscopy (FESEM) to study the high-resolution organization of cellulose microfibrils in onion epidermal cell walls. We frequently found that conventional “rule of thumb” conditions for imaging of biological samples did not yield high-resolution images of cellulose organization and often resulted in artifacts or distortions of cell wall structure. Here we detail our method of one-step fixation and dehydration with 100% ethanol, followed by critical point drying, ultrathin iridium (Ir) sputter coating (3 s), and FESEM imaging at a moderate accelerating voltage (10 kV) with an In-lens detector. We compare results obtained with our improved protocol with images obtained with samples processed by conventional aldehyde fixation, graded dehydration, sputter coating with Au, Au/Pd, or carbon, and low-voltage FESEM imaging. The results demonstrated that our protocol is simpler, causes little artifact, and is more suitable for high-resolution imaging of cell wall cellulose microfibrils whereas such imaging is very challenging by conventional methods.

biofuels (including algae and biomass), bio-inspir↗

A Simple Preparation Method for Full-Range Electron Tomography of Nanoparticles and Fine Powders

Abstract Electron tomography has become a valuable and widely used tool for studying the three-dimensional nanostructure of materials and biological specimens. However, the incomplete tilt range provided by conventional sample holders limits the fidelity and quantitative interpretability of tomographic images by leaving a “missing wedge” of unknown information in Fourier space. Imaging over a complete range of angles eliminates missing wedge artifacts and dramatically improves tomogram quality. Full-range tomography is usually accomplished using needle-shaped samples milled from bulk material with focused ion beams, but versatile specimen preparation methods for nanoparticles and other fine powders are lacking. In this work, we present a new preparation technique in which powder specimens are supported on carbon nanofibers that extend beyond the end of a tungsten needle. Using this approach, we produced tomograms of platinum fuel cell catalysts and gold-decorated strontium titanate photocatalyst specimens. Without the missing wedge, these tomograms are free from elongation artifacts, supporting straightforward automatic segmentation and quantitative analysis of key materials properties such as void size and connectivity, and surface area and curvature. This approach may be generalized to other samples that can be dispersed in liquids, such as biological structures, creating new opportunities for high-quality electron tomography across disciplines.

Materials Science↗

Focused Ion Beam Preparation of Low Melting Point Metals: Lessons Learned From Indium

Indium (In) and other low melting point metals are used as interconnects in a variety of hybridized circuits and a full understanding of the metallurgy of these interconnects is important to the reliability and performance of the devices. Here, this paper shows that room temperature focused ion beam (FIB) preparation of cross-sections, using Ga + or Xe + can result in artifacts that obscure the true In microbump structure. The use of modified milling strategies to minimize the increased local sample temperature are shown to produce cross-sections that are representative of the In bump microstructure in some sample configurations. Furthermore, cooling of the sample to cryogenic temperatures is shown to reliably eliminate artifacts in FIB prepared cross-sections of In bumps allowing the true bump microstructure to be observed.

36 MATERIALS SCIENCE↗

Coupled Cluster Theory for Nonadiabatic Dynamics: Nuclear Gradients and Nonadiabatic Couplings in Similarity Constrained Coupled Cluster Theory

Coupled cluster theory is one of the most accurate electronic structure methods for predicting ground and excited state chemistry. However, the presence of numerical artifacts at electronic degeneracies, such as complex energies, has made it difficult to apply the method in nonadiabatic dynamics simulations. While it has already been shown that such numerical artifacts can be fully removed by using similarity constrained coupled cluster (SCC) theory [J. Phys. Chem. Lett. 2017, 8(19), 4801–4807], simulating dynamics requires efficient implementations of gradients and nonadiabatic couplings. Here, we present an implementation of nuclear gradients and nonadiabatic derivative couplings at the similarity constrained coupled cluster singles and doubles (SCCSD) level of theory, thereby making possible nonadiabatic dynamics simulations using a coupled cluster theory that provides a correct description of conical intersections between excited states. We present a few numerical examples that show good agreement with literature values and discuss some limitations of the method.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The many-body expansion for aqueous systems revisited: 1. Water-water interactions

We revisit the Many-Body Expansion (MBE) for water-water interactions by examining the effects of the basis set, including those resulting from the Basis Set Superposition Error (BSSE) correction, on the various terms for selected sizes of water clusters up to n = 21. The analysis is performed at the second order Møller-Plesset (MP2) perturbation theory with the family of augmented correlation consistent basis sets up to five zeta quality for the (H2O)n, n = 7, 10, 13, 16 and 21 clusters, for which we report either the complete MBE (n = 7, 10) or the one through the 6-body (n = 13) and the 5-body terms (n = 16, 21). Our results suggest that any sizeable contributions to the total cluster binding energy arising from the 5-body and larger terms are solely an artifact of the size of the basis set. Indeed, all terms above the 4-body converge monotonically to practically zero at the Complete Basis Set (CBS) limit. The magnitudes of the 5-body and above terms are accurately reproduced even with the smaller basis set of the series (aug-cc-pVDZ) once the BSSE correction is taken into account. The same level of theory (MP2/aug-cc-pVDZ, BSSEcorrected) also accurately reproduces the MP2/CBS values of the 3- and 4-body terms. The contribution of electron correlation to the 3- and 4-body terms is quite small, so that neglecting the correlation contribution in all terms above the 3-body results in an error of ??(0.1%). The BSSE correction to the largest 2-body term in the MBE was accurately estimated from the function ?? [1 + erf(-?? ??)], which is proportional to the common (overlapping) area between two Gaussian distributions whose centers are separated by R, with the constants ??, ?? fitted to the calculated BSSE corrections for the individual 2-body terms of the clusters with each basis set. Our results unquestionably demonstrate that the MBE for water-water interactions converges to the 4-body term, since any finite terms above the 4-body are artifacts of the size of the basis set and can be safely truncated at the 4-body term when either a very large basis set is used or BSSE corrections are taken into account even with the aug-cc-pVDZ basis set. We expect these findings to have important consequences in the pursuit of accurate many-body molecular dynamics simulations for aqueous systems.

Heindel, Joseph↗

Challenges in Pulsed-Field Gradient Nuclear Magnetic Resonance on Magnetically Heterogeneous Interfaces: Sequence and Field-Dependent Apparent Diffusion Coefficients

It is well known that the internal gradient (gi) that exists within pores haunts the diffusion coefficient (D) as measured by the pulsed-field gradient (PFG) nuclear magnetic resonance (NMR). Several PFG-NMR methods developed to determine an accurate D were not successful. Then, the steady-state diffusion coefficient (Dapp,8) for the cation [C4mim]+ of [C4mim][Tf2N]; [1-butyl-3-methylimidazolium][bis(trifluoromethylsulfonyl)imde] ionic liquid confined in ordered mesoporous carbon (OMC) were determined by comparing Dapp,8 obtained from 1H PFG-NMR performed with three different stimulated echo sequences: STE, APFG, and MPFG under the two external magnetic field strength, B0 = 9.4 and 14.1 Tesla. The measured Dapp,8 which is an order of magnitude smaller than D of bulk [C4mim][Tf2N], is in good agreement between APFG and MPFG both in B0 = 9.4 and 14.1 Tesla. However, the strong gi artifact, which caused apparent diffusion coefficient (Dapp) depending strongly and weakly on B0 and temperature, respectively, in diffusion-time dependent Dapp, Dapp(?) obtained from a sequence with monopolar gradients (STE) was suppressed by using sequences employing bipolar gradients (APFG and MPFG) in the region of steady-state diffusion. But incompletely suppressed gi artifact resulting in the different behaviors of the early part of Dapp(?) between the sequences leads a ˜ 0.6 and 0.9 in MPFG and APFG, respectively, in the relationship between mean squared displacement and diffusion time: = 2Dta, where a = 0.5 and 1 for 1-dimensional single file diffusion and 3-dimensional bulk diffusion, respectively. The above observations clearly show that the diffusion behavior of ions/molecules within the pores and pore structure, such as the surface-to-volume ratio? (D?_app (?)=D_0 [1-4/(9vp) S/V v(D_0 ?)]) and tortuosity (T = D0/Dapp,8), are possible to be misunderstood, especially in the systems with a non-negligible gi. This work demonstrates that it may be necessary to test several PFG sequences under multiple external magnetic fields for the correct determination of the diffusion behavior of ions/molecules in the pores with a larger internal gradient, gi.

Han, Kee Sung↗

Is There a Negative Thermal Expansion in Supported Metal Nanoparticles? An in Situ X-ray Absorption Study Coupled with Neural Network Analysis

Interactions with their support, adsorbates, and unique structural motifs are responsible for many intriguing properties and potential applications of supported metal nanoparticles (NPs). At the same time, they complicate the interpretation of experimental data. In fact, the methods and approaches that work well for the ex situ analysis of bulk materials may be inaccurate or introduce artifacts in the in situ analysis of nanomaterials. Here, we revisit the controversial topic of negative thermal expansion and anomalies in the Debye temperature reported for oxide-supported metal NPs. In situ X-ray absorption experimental data collected for Pt NPs in ultrahigh vacuum and an advanced data analysis approach based on an artificial neural network demonstrate that Pt NPs do not exhibit intrinsic negative thermal expansion. Similarly, as for bulk materials, in the absence of adsorbates and strong particle-support interaction, the bond lengths in metal NPs increase with temperature. Lastly, the previously reported anomalies in particle-size-dependent Debye temperatures can also be linked to the artifacts in the interpretation of conventional X-ray absorption data of disordered materials such as NPs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Parallel Electrochemical Treatment System and Application for Identifying Acid-Stable Oxygen Evolution Electrocatalysts

There are many energy technologies require electrochemical stability or preactivation of functional materials. Due to the long experiment duration required for either electrochemical preactivation or evaluation of operational stability, parallel screening is required to enable high throughput experimentation. We found that imposing operational electrochemical conditions to a library of materials in parallel creates several opportunities for experimental artifacts. We discuss the electrochemical engineering principles and operational parameters that mitigate artifacts int he parallel electrochemical treatment system. We also demonstrate the effects of resistive losses within the planar working electrode through a combination of finite element modeling and illustrative experiments. Operation of the parallel-plate, membrane-separated electrochemical treatment system is demonstrated by exposing a composition library of mixed metal oxides to oxygen evolution conditions in 1M sulfuric acid for 2h. This application is particularly important because the electrolysis and photoelectrolysis of water are promising future energy technologies inhibited by the lack of highly active, acid-stable catalysts containing only earth abundant elements.

14 SOLAR ENERGY↗

In-Source Fragmentation and the Sources of Partially Tryptic Peptides in Shotgun Proteomics

Partially tryptic peptides are often identified in shotgun proteomics using trypsin as the proteolytic enzyme; however, it has been controversial regarding the sources of such partially tryptic peptides. Herein we investigate the impact of in-source fragmentation on shotgun proteomics using three biological samples, including a standard protein mixture, a mouse brain tissue homogenate, and a mouse plasma sample. Since the in-source fragments of a peptide retain the same elution time with its parent fully tryptic peptide, the partially tryptic peptides from in-source fragmentation can be distinguished from the other partially tryptic peptides by plotting the observed retention times against the computationally predicted retention times. Most partially tryptic in-source fragmentation artifacts were misaligned from the linear distribution of fully tryptic peptides. The impact of in-source fragmentation on peptide identifications was clearly significant in a less complex sample such as a standard protein digest, where ~60 % of unique peptides were observed as partially tryptic peptides from in-source fragmentation. In mouse brain or mouse plasma samples, in-source fragmentation contributed to 1-3 % of all identified peptides. The other major source of partially tryptic peptides in complex biological samples is presumably proteolytic processing by endogenous proteases in the samples. By filtering out the in-source fragmentation artifacts from the identified partially tryptic or non-tryptic peptides, it is possible to directly survey in-vivo proteolytic processing in biological samples such as blood plasma.

59 BASIC BIOLOGICAL SCIENCES↗

All-optical image denoising using a diffractive visual processor

Abstract Image denoising, one of the essential inverse problems, targets to remove noise/artifacts from input images. In general, digital image denoising algorithms, executed on computers, present latency due to several iterations implemented in, e.g., graphics processing units (GPUs). While deep learning-enabled methods can operate non-iteratively, they also introduce latency and impose a significant computational burden, leading to increased power consumption. Here, we introduce an analog diffractive image denoiser to all-optically and non-iteratively clean various forms of noise and artifacts from input images – implemented at the speed of light propagation within a thin diffractive visual processor that axially spans <250 × λ, where λ is the wavelength of light. This all-optical image denoiser comprises passive transmissive layers optimized using deep learning to physically scatter the optical modes that represent various noise features, causing them to miss the output image Field-of-View (FoV) while retaining the object features of interest. Our results show that these diffractive denoisers can efficiently remove salt and pepper noise and image rendering-related spatial artifacts from input phase or intensity images while achieving an output power efficiency of ~30–40%. We experimentally demonstrated the effectiveness of this analog denoiser architecture using a 3D-printed diffractive visual processor operating at the terahertz spectrum. Owing to their speed, power-efficiency, and minimal computational overhead, all-optical diffractive denoisers can be transformative for various image display and projection systems, including, e.g., holographic displays.

36 MATERIALS SCIENCE↗