Joint Inversion of Regional Waveform, First-Motion Polarity, and Synthetic Aperture Radar Surface Displacement for the Fourth and Sixth North Korean Declared Nuclear Explosions

Here, this study analyzed the Democratic People’s Republic of Korea’s (DPRK) fourth (DPRK4, 6 January 2016 M w 4.49) and sixth (DPRK6, 7 September 2017 M w 5.2) declared nuclear tests, employing a joint seismic and Interferometric Synthetic Aperture Radar (InSAR) inversion to improve understanding of these events and enhance moment tensor (MT) inversion capabilities. The recent efforts have focused on employing seismic waveform and InSAR geodetic deformation data separately to analyze these and the previous nuclear tests (e.g., Chiang et al., 2018; Myers et al., 2018; Wang et al., 2018). Building upon our previous work (Chi-Durán et al., 2021), we performed a joint regional waveform, first-motion (FM) polarity, and surface displacement inversion, which demonstrated improved source-type discrimination, a revised MT solution with reduced scalar moment uncertainty, and an independently constrained location. In this article, we build on the previous results for DPRK6 by including an analysis using a four-layered velocity model with free-surface topography to compute the near-source static deformation Green’s functions. The model consists of a 50 m basalt layer (⁠V P = 2.07 km/s, V S = 1.2 km/s⁠), a 250 m stratified volcanic deposit layer (⁠V P = 1.73 km/s, V S = 1.0 km/s⁠), a 700 m weathered granodiorite layer (⁠V P = 2.5 km/s, V S = 1.3 km/s⁠⁠), and a granodiorite half-space (⁠V P = 5.35 km/s, V S = 3.09 km/s⁠⁠). The half-space shares the velocity of the regional MDJ2 velocity model (Ford et al., 2010), which has proven effective for waveform inversion in the region. This model considers the range of reported values for various lithologies and weathering effects. Our findings show that using the layered velocity model enhances the recovery of source location and depth for both the explosions by improving fits and reducing uncertainties. The joint inversion also improves source-type discrimination and better constrains the scalar seismic moment necessary for downstream yield estimation.

58 GEOSCIENCES↗

Multipole effects on dynamic aperture in JLEIC ion collider ring

In a collider, stronger focusing at the interaction point (IP) for low beta-star and high luminosity produces large beams at final focusing quadrupoles (FFQs). To achieve the high luminosity requirement in the Jefferson Lab Electron-Ion Collider (JLEIC), the interaction region (IR) beta functions peak at ~4.2 km in downstream FFQs. These large beta functions and FFQ multipoles reduce the dynamic aperture (DA) of the ring. A study of the multipole effects on the DA was performed to determine limits on multipoles, and to include a multipole compensation scheme to increase the DA and beam lifetime.

Rajput-Ghoshal, Renuka↗

Dynamic aperture studies at the Fermilab recycler ring

As part of the Proton Improvement Plan II (PIP-II), Fermilab aims to increase beam intensity delivered to neutrino experiments. In this context, higher intensity injection into the Recycler Ring enhances space charge effects, pushing operations closer to third-order resonances. These resonances reduce the Dynamic Aperture (DA), leading to increased beam loss. This study presents simulations of DA as a function of tune in the Recycler Ring, incorporating chaos indicators such as the Reversibility Error Method (REM) and Frequency Map Analysis (FMA). The effectiveness of existing resonance mitigation strategies is evaluated by quantifying their ability to delay DA degradation. Additionally, the study examines how space charge detuning and DA limitations dictate viable operational tune points for the Recycler Ring.

Gonzalez-Ortiz, Cristhian [Fermilab]↗

Dynamic aperture evaluation of the proposed lattices for the RHIC 2009 polarized proton run

In the article we evaluate the dynamic apertures of the proposed lattices for the coming Relativistic Heavy Ion Collider (RHIC) 2009 polarized proton (pp) 100 GeV and 250 GeV runs. One goal of this study is to find out the appropriate β ∗ for the coming 2009 pp runs. Another goal is to study the effect of second order chromaticity correction in the RHIC pp runs.

43 PARTICLE ACCELERATORS↗

Dynamic Aperture Calculation for 100 GeV Au-Au and 250GeV pp Lattices with Near Third Order Resonance Working Point

In the preparation for the 2011 RHIC 250 GeV polarized proton (pp) run, both experiment and simulation were carried out to investigate the possibility to accelerate the proton beam with a vertical tune near 2/3. It had been found experimentally in Run-9 that accelerating the proton beam with a vertical tune close to 2/3 will greatly benefit the transmission of the proton polarization. In this note, we report the calculated dynamic apertures with the 100 GeV Au run and 250 GeV proton run lattices with vertical tunes close to the third order resonance. We will compare the third order resonance band width between the beam experiment and the simulation with the 100 GeV Au lattices. And we also will compare the calculated resonance band width between the 100 GeV Au and 250 GeV proton run lattices.

43 PARTICLE ACCELERATORS↗

A Deployable Fast-Neutron Coded-Aperture Imager for Quantifying Nuclear Material

This brief report describes a newly constructed fast-neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M4FT-13OR0402053, “Construct Imager,” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast-Neutron Imaging to Quantify Nuclear Materials - ORNL.” The first measurements taken with the imager will be reported later this year. For quantifying plutonium holdup, fast-neutron imaging is an appealing mode of measurement in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. The use of fast neutrons (as opposed to the more numerous gamma rays) is appealing because of their ability to penetrate equipment and nuclear material that is opaque to gamma radiation. However, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager sufficiently compact to be amenable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Furthermore, while fast-neutron detection is commonly achieved via organic liquid scintillators, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34.

Hausladen, Paul↗

The Deployable Fast-Neutron Coded-Aperture Imager: Demonstration of Locating One or More Sources in Three Dimensions

This brief report describes commissioning measurements performed using a newly constructed fast neutron coded-aperture imager intended for performing quantitative measurements of plutonium holdup at fuel cycle facilities. The present report was prepared in fulfillment of milestone M3FT-13OR0402054, “Imager commissioning and 3D source configuration measurements” of Fuel Cycle R&D Material Protection, Accounting, and Control Technology (MPACT) work package FT-13OR040205, “Fast Neutron Imaging to Quantify Nuclear Materials - ORNL.” In addition to representing the first measurements made with the new device, these measurements also demonstrate for the first time the ability to localize one or more neutron sources in three dimensions by combining imaging data from multiple measurements in which the imager was positioned at different locations. The development and use of fast-neutron imaging technology are motivated by a desire to locate and quantify plutonium holdup in scenarios where contact measurements with non-imaging detectors may be impractical or their results ambiguous because of surrounding material or nearby sources. Considering the goal of quantitative measurements, fast neutrons (as opposed to the more numerous gamma rays) are preferred in many situations because of their ability to penetrate equipment and nuclear material that are essentially opaque to gamma radiation. However, there are many challenges associated with constructing a practical imager for fast neutrons. For example, the ability of fast neutrons to penetrate material also leads to challenges in constructing a fast-neutron imager that is sufficiently compact to be suitable for use in a facility while remaining sufficiently sensitive to neutron emanations from plutonium or other actinides. Moreover, use of the imager in a production environment favors mechanically robust detectors that do not contain flammable liquid, unlike the organic liquid scintillators that are typically used to achieve fast-neutron detection. Last of all, a single-sided measurement geometry, as is typically used in imaging applications, necessitates accurate measurement of the location of a deposit of plutonium holdup in three dimensions in order to correctly infer the source strength. In response to these challenges, Oak Ridge National Laboratory (ORNL) has built a fast-neutron imager that has a compact footprint and whose segmented neutron detectors are built from the first cast plate of the recently developed plastic scintillator with pulse shape discrimination properties developed by Lawrence Livermore National Laboratory and commercially available from Eljen Technologies as experimental scintillator EJ-299-34. This report presents a description and preliminary analysis of mock holdup measurements intended to determine the three-dimensional location of one or more neutron sources placed in prototypical equipment from a set of imaging measurements that scanned the extent of the equipment.

Hausladen, Paul↗

Analysis to determine the maximum dimensions of flexible apertures in sensored security netting products.

Although technological advances provide new capabilities to increase the robustness of security systems, they also potentially introduce new vulnerabilities. New capability sometimes requires new performance requirements. This paper outlines an approach to establishing a key performance requirement for an emerging intrusion detection sensor: the sensored net. Throughout the security industry, the commonly adopted standard for maximum opening size through barriers is a requirement based on square inches typically 96 square inches. Unlike standard rigid opening, the dimensions of a flexible aperture are not fixed, but variable and conformable. It is demonstrably simple for a human intruder to move through a 96-square-inch opening that is conformable to the human body. The longstanding 96-square-inch requirement itself, though firmly embedded in policy and best practice, lacks a documented empirical basis. This analysis concluded that the traditional 96-square-inch standard for openings is insufficient for flexible openings that are conformable to the human body. Instead, a circumference standard is recommended for these newer types of sensored barriers. The recommended maximum circumference for a flexible opening should be no more than 26 inches, as measured on the inside of the netting material.

Murton, Mark↗

Performance limits for maritime Inverse Synthetic Aperture Radar (ISAR)

The performance of an Inverse Synthetic Aperture Radar (ISAR) system depends on a variety of factors, many which are interdependent in some manner. In this report we specifically examine ISAR as applied to maritime targets (e.g. ships). It is often difficult to get your arms around the problem of ascertaining achievable performance limits, and yet those limits exist and are dictated by physics. This report identifies and explores those limits, and how they depend on hardware system parameters and environmental conditions. Ultimately, this leads to a characterization of parameters that offer optimum performance for the overall ISAR system. While the information herein is not new to the literature, its collection into a single report hopes to offer some value in reducing the seek time .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiphase Fluid Flow in Deformable Variable-Aperture Fractures (Final Report, February 1, 2009 – January 31, 2014)

Fractures provide flow paths that can potentially lead to fast migration of fluids or contaminants. A number of energy-­related applications involve fluid injections that significantly perturb both the pressures and chemical composition of subsurface fluids. These perturbations can cause both mechanical deformation and chemical alteration of host rocks with potential for significant changes in permeability. In fractured rock subjected to coupled chemical and mechanical stresses, it can be difficult to predict the sign of permeability changes, let alone the magnitude. This project integrated experimental and computational studies to improve mechanistic understanding of these coupled processes and develop and test predictive models and monitoring techniques. The project involved three major components: (1) study of two-­phase flow processes involving mass transfer between phases and dissolution of minerals along fracture surfaces (Detwiler et al., 2009; Detwiler, 2010); (2) study of fracture dissolution in fractures subjected to normal stresses using experimental techniques (Ameli, et al., 2013; Elkhoury et al., 2013; Elkhoury et al., 2014) and newly developed computational models (Ameli, et al., 2014); (3) evaluation of electrical resistivity tomography (ERT) as a method to detect and quantify gas leakage through a fractured caprock (Breen et al., 2012; Lochbuhler et al., 2014). The project provided support for one PhD student (Dr. Pasha Ameli; 2009-­2013) and partially supported a post-­doctoral scholar (Dr. Jean Elkhoury; 2010-­2013). In addition, the project provided supplemental funding to support collaboration with Dr. Charles Carrigan at Lawrence Livermore National Laboratory in connection with (3) and supported one MS student (Stephen Breen; 2011-­2013). Major results from each component of the project include the following: (1) Mineral dissolution in fractures occupied by two fluid phases (e.g., oil-­water or water-­CO 2 ) causes changes in local capillary forces and redistribution of fluids. These coupled processes enhance channel formation and the potential for development of fast flow paths through fractures. (2) Dissolution in fractures subjected to normal stress can result in behaviors ranging from development of dissolution channels and rapid permeability increases to fracture healing and significant permeability decreases. The timescales associated with advective transport of dissolved ions in the fracture, mineral dissolution rates, and diffusion within the adjacent porous matrix dictate the sign and magnitude of the resulting permeability changes. Furthermore, a high--resolution mechanistic model that couples elastic deformation of contacts and aperture-­dependent dissolution rates predicts the range of observed behaviors reasonably well. (3) ERT has potential as a tool for monitoring gas leakage in deep formations. Using probabilistic inversion methods further enhances the results by providing uncertainty estimates of inverted parameters.

02 PETROLEUM↗

Initial Estimates of Dynamic Aperture and Field Quality Specifications

In this report the target field quality for the inner triplets is given. This initial specification is based on the most recent estimate of the expected field quality provided by the magnet designers. The expected field quality has been probed by means of massive numerical simulations, which are aimed at computing the dynamic aperture and its dependence on the triplet quadrupoles field imperfections. The initial estimate of the required field quality will be further analysed against measured data, whenever available, in view of possible refinement of the target errors. A preliminary check of the impact of the field quality of the other insertion magnets, both separation dipoles and quadrupoles, from D1 to Q5 has been made and a quantitative specification of the field quality will follow, always based on the expected field quality estimates.

ACCPHY↗

Motion measurement for synthetic aperture radar

Synthetic Aperture Radar (SAR) measures radar soundings from a set of locations typically along the flight path of a radar platform vehicle. Optimal focusing requires precise knowledge of the sounding source locations in 3-D space with respect to the target scene. Even data driven focusing techniques (i.e. autofocus) requires some degree of initial fidelity in the measurements of the motion of the radar. These requirements may be quite stringent especially for fine resolution, long ranges, and low velocities. The principal instrument for measuring motion is typically an Inertial Measurement Unit (IMU), but these instruments have inherent limi ted precision and accuracy. The question is %22How good does an IMU need to be for a SAR across its performance space?%22 This report analytically relates IMU specifications to parametric requirements for SAR. - 4 - Acknowledgements Th e preparation of this report is the result of a n unfunded research and development activity . Although this report is an independent effort, it draws heavily from limited - release documentation generated under a CRADA with General Atomics - Aeronautical System, Inc. (GA - ASI), and under the Joint DoD/DOE Munitions Program Memorandum of Understanding. Sandia National Laboratories is a multi - program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of En ergy's National Nuclear Security Administration under contract AC04-94AL85000.

47 OTHER INSTRUMENTATION↗

Limits to Clutter Cancellation in Multi-Aperture GMTI Data

Multi-aperture or multi-subaperture antennas are fundamental to Ground Moving Target Indicator (GMTI) radar systems in order to detect slow-moving targets with Doppler characteristics similar to clutter. Herein we examine the performance of several subaperture architectures for their clutter cancelling performance. Significantly, more antenna phase centers isn’t always better, and in fact is sometimes worse, for detecting targets.

42 ENGINEERING↗

Apodized RFI Filtering of Synthetic Aperture Radar Images

Fine resolution Synthetic Aperture Radar (SAR) systems necessarily require wide bandwidths that often overlap spectrum utilized by other wireless services. These other emitters pose a source of Radio Frequency Interference (RFI) to the SAR echo signals that degrades SAR image quality. Filtering, or excising, the offending spectral contaminants will mitigate the interference, but at a cost of often degrading the SAR image in other ways, notably by raising offensive sidelobe levels. This report proposes borrowing an idea from nonlinear sidelobe apodization techniques to suppress interference without the attendant increase in sidelobe levels. The simple post-processing technique is termed Apodized RFI Filtering (ARF).

42 ENGINEERING↗

A parametric study of rate of advance and area coverage rate performance of synthetic aperture radar.

The linear ground distance per unit time and ground area covered per unit time of producing synthetic aperture radar (SAR) imagery, termed rate of advance (ROA) and area coverage rate (ACR), are important metrics for platform and radar performance in surveillance applications. These metrics depend on many parameters of a SAR system such as wavelength, aircraft velocity, resolution, antenna beamwidth, imaging mode, and geometry. Often the effects of these parameters on rate of advance and area coverage rate are non-linear. This report addresses the impact of different parameter spaces as they relate to rate of advance and area coverage rate performance.

47 OTHER INSTRUMENTATION↗

Event Localization in Bulk Scintillator Crystals Using Coded Apertures

The localization of radiation interactions in bulk scintillators is generally limited by the size of the light distribution at the readout surface of the crystal/light-pipe system. By finding the centroid of the light spot, which is typically of order centimeters across, practical single-event localization is limited to ~2 mm/cm of crystal thickness. Similar resolution can also be achieved for the depth of interaction by measuring the size of the light spot. Through the use of near-field coded-aperture techniques applied to the scintillation light, light transport simulations show that for 3-cm-thick crystals, more than a five-fold improvement (millimeter spatial resolution) can be achieved both laterally and in event depth. At the core of the technique is the requirement to resolve the shadow from an optical mask placed in the scintillation light path between the crystal and the readout. In this paper, experimental results are presented that demonstrate the overall concept using a 1D shadow mask, a thin-scintillator crystal and a light pipe of varying thickness to emulate a 2.2-cm-thick crystal. Spatial resolutions of ~ 1 mm in both depth and transverse to the readout face are obtained over most of the crystal depth.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A parameterized ray-tracing model for evaluation of hemispherical lensing of a uniform, telecentric object aperture -- performance improvement estimates for segmented scintillators with miniature lens arrays

A parametric model describing the collimation of radiation from a uniform circular aperture by a hemispherical lens of the same radius has been developed for rapid estimation of the potential benefit of miniature dielectric lens arrays in lens-coupled gamma ray cameras (GRCs) with segmented scintillators. A simplified ray-tracing approach is adopted that makes use of small angle approximations relevant to GRCs used in nuclear science at Los Alamos National Laboratory and elsewhere. Application of this analysis technique in a first-pass design optimization process results in the optimistic estimate that miniature lenses fabricated from typical optical quality glass might boost optical coupling by as much as a factor of 4 (6 dB gain). However, this is not likely to be economically attractive compared to other techniques, such as reduction of the GRC lens f-number.

47 OTHER INSTRUMENTATION↗