Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “AC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Mitigating challenges in aberration-corrected electron-beam lithography on electron-opaque substrates

Aberration-corrected electron-beam lithography (AC-EBL) using ultra-thin electron transparent membranes has achieved single-digit nanometer resolution in two widely used electron-beam resists: poly (methyl methacrylate) (PMMA) and hydrogen silsesquioxane. On the other hand, AC-EBL implementation on thick, electron-opaque substrates is appealing for conventional top-down fabrication of quantum devices with nanometer-scale features. To investigate the performance of AC-EBL on thick substrates, we measured the lithographic point spread function of a 200 keV aberration-corrected scanning transmission electron microscope by defining both positive and negative patterns in PMMA thin films, spin-cast on thick SiO 2 /Si substrates. We present the problems encountered during pre-exposure beam focusing and discuss methods to overcome them. In addition, applying some of these methods using commercial 50 nm thick SiN X membranes with thick Si support frames, we printed arrays of holes in PMMA with pitches around 26 nm on SiN X /Si substrates with increasing Si thickness. Here, our results show that proximity effects from even 50 nm thick SiN X membranes limit hole arrays to 20 nm pitch; however, down to this limit, the effect of the substrate thickness on the pattern quality is minimal. These results highlight the need for novel resists less susceptible to proximity effects, or resists which can be used directly, after development, as the dielectric material in periodic gates in 2D quantum devices.

2D quantum devices↗

Directed motion of liquid crystal skyrmions with oscillating fields

Abstract Using continuum simulations, we show that under a sinusoidal electric field, liquid crystal skyrmions undergo periodic shape oscillations which produce controlled directed motion. The speed of the skyrmion is non-monotonic in the frequency of the applied field, and exhibits multiple reversals of the motion as a function of changing frequency. We map out the dynamical regime diagram of the forward and reverse motion for two superimposed ac driving frequencies, and show that the reversals and directed motion can occur even when only a single ac driving frequency is present. Using pulsed ac driving, we demonstrate that the motion arises due to an asymmetry in the relaxation times of the skyrmion shape. We discuss the connection between our results and ratchet effects observed in systems without asymmetric substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic field effects and transverse ratchets in charge lattices coupled to asymmetric substrates

We examine a charge lattice coupled to a one-dimensional asymmetric potential in the presence of an applied magnetic field, which induces gyrotropic effects in the charge motion. This system could be realized for Wigner crystals in nanostructured samples, dusty plasmas, or other classical charge-ordered states where gyrotropic motion and damping can arise. For zero magnetic field, an applied external ac drive can produce a ratchet effect in which the particles move along the easy flow direction of the substrate asymmetry. The zero field ratchet effect can only occur when the ac drive is aligned with the substrate asymmetry direction; however, when a magnetic field is added, the gyrotropic forces generate a Hall effect that leads to a variety of new behaviors, including a transverse ratchet motion that occurs when the ac drive is perpendicular to the substrate asymmetry direction. We show that this system exhibits commensuration effects as well as reversals in the ratchet effect and the Hall angle of the motion. The magnetic field also produces a nonmonotonic ratchet efficiency when the particles become localized at high fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Emergency department visits in California associated with wildfire PM 2.5 : differing risk across individuals and communities

The threats to human health from wildfires and wildfire smoke (WFS) in the United States (US) are increasing due to continued climate change. A growing body of literature has documented important adverse health effects of WFS exposure, but there is insufficient evidence regarding how risk related to WFS exposure varies across individual or community level characteristics. To address this evidence gap, we utilized a large nationwide database of healthcare utilization claims for emergency department (ED) visits in California across multiple wildfire seasons (May through November, 2012–2019) and quantified the health impacts of fine particulate matter <2.5 μm (PM 2.5 ) air pollution attributable to WFS, overall and among subgroups of the population. We aggregated daily counts of ED visits to the level of the Zip Code Tabulation Area (ZCTA) and used a time-stratified case-crossover design and distributed lag non-linear models to estimate the association between WFS and relative risk of ED visits. We further assessed how the association with WFS varied across subgroups defined by age, race, social vulnerability, and residential air conditioning (AC) prevalence. Over a 7 day period, PM 2.5 from WFS was associated with elevated risk of ED visits for all causes (1.04% (0.32%, 1.71%)), non-accidental causes (2.93% (2.16%, 3.70%)), and respiratory disease (15.17% (12.86%, 17.52%)), but not with ED visits for cardiovascular diseases (1.06% (–1.88%, 4.08%)). Analysis across subgroups revealed potential differences in susceptibility by age, race, and AC prevalence, but not across subgroups defined by ZCTA-level Social Vulnerability Index scores. These results suggest that PM 2.5 from WFS is associated with higher rates of all cause, non-accidental, and respiratory ED visits with important heterogeneity across certain subgroups. Notably, lower availability of residential AC was associated with higher health risks related to wildfire activity.

54 ENVIRONMENTAL SCIENCES↗

Ultralight dark matter detection with levitated ferromagnets

Levitated ferromagnets act as ultraprecise magnetometers, which can exhibit high quality factors due to their excellent isolation from the environment. These instruments can be utilized in searches for ultralight dark matter candidates, such as axionlike dark matter or dark-photon dark matter. In addition to being sensitive to an axion-photon coupling or kinetic mixing, which produce physical magnetic fields, ferromagnets are also sensitive to the effective magnetic field (or “axion wind”) produced by an axion-electron coupling. While the dynamics of a levitated ferromagnet in response to a dc magnetic field have been well studied, all of these couplings would produce ac fields. In this work, we study the response of a ferromagnet to an applied ac magnetic field and use these results to project their sensitivity to axion and dark-photon dark matter. We pay special attention to the direction of motion induced by an applied ac field, in particular, whether it precesses around the applied field (similar to an electron spin) or librates in the plane of the field (similar to a compass needle). We show that existing levitated ferromagnet setups can already have comparable sensitivity to an axion-electron coupling as comagnetometer or torsion balance experiments. In addition, future setups can become sensitive probes of axion-electron coupling, dark-photon kinetic mixing, and axion-photon coupling, for ultralight dark matter masses m DM ≲ feV . Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stripe and bubble ratchets on asymmetric substrates

We show that various nonmonotonic ratchet effects can arise when mesophase pattern-forming systems, which exhibit anisotropic crystal, stripe, and bubble regimes, are coupled to one-dimensional asymmetric substrates under ac driving. The patterns emerge in the absence of a substrate when the ratio of attraction to repulsion is varied for particles with competing short-range attraction and long-range repulsion potentials. In the presence of the substrate, we find that the ratchet efficiency varies nonmonotonically with increasing attraction, depending upon how well the mesophase morphology matches the substrate spacing and periodicity. For strong repulsion, there is a weak but finite ratchet effect, while at intermediate attraction, there is a robust ratchet effect in which the system forms stripes aligned with the substrate symmetry direction. For strong attraction, large bubbles appear that have weak or no ratchet effects when the bubble width exceeds the substrate lattice spacing, causing the bubble to be only weakly coupled to the substrate. For very strong attraction, small bubbles form and undergo a strong ratchet effect with an efficiency that oscillates as a function of ac drive amplitude. Although the small bubble regime is a strongly correlated regime in which each bubble contains many particles, the system behaves as if it is in a single-particle regime since the bubble width is much smaller than the substrate lattice spacing. We map out the different rectification phases as a function of the pattern morphology, substrate strength, and ac drive amplitude. The pronounced ratchet effects that we observe in some regimes can be exploited for pattern sorting in hard and soft matter systems. Published by the American Physical Society 2024

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A High-Frequency Planar Transformer with Medium-Voltage Isolation

This paper presents the design of a low-loss, high-frequency planar transformer having medium-voltage (10’s of kV) isolation capability while transformer primary and secondary windings are interleaved to reduce losses. Medium-voltage isolation between adjacent printed circuit board (PCB) layers is extremely challenging using traditional PCB dielectrics. The isolation requirement is met using PCB with 7 kV/mil polyimide (Panasonic Felios RF775) as the dielectric, and by an appropriate layout of the windings and the inter-winding vias. The transformer is used to implement a dual active bridge (DAB) converter in a stackable dc-ac architecture where the dc port is connected to a photovoltaic (PV) string and ac outputs are connected in series to achieve direct PV string-to-medium voltage conversion without the need for low-voltage collection or a bulky line frequency transformer. Since each DAB transformer processes time-varying power, a design methodology is developed to minimize line-cycle-averaged losses. Experimental results are presented for a 1:1 planar transformer in a 7.5 kW SiC-based dc-to-ac module operating at 200 kHz. Isolation of 26 kV between the primary and secondary layers and between the windings and the core is verified using a hipot tester.

insulation resistance↗

Experimental Validation of a 40kW, 480V Point-to-Point DC Interlinks for Controller-Agnostic, Interoperable Networked Microgrids

This paper presents the experimental validation of point-to-point dc-interlinks for interconnecting two solar-based, laboratory-scale AC microgrids. DC interlinks provide a solution to numerous technical and operational challenges encountered in networked microgrids, including precise power flow control, stable and fast synchronization, enhanced stability, and improved voltage and frequency regulation. By decoupling microgrids through power converters, dc-interlinks enable power exchange among microgrids that can be owned by different entities (such as communities, utilities, or universities) and managed by diverse microgrid controller vendors. This characteristic makes this dc-interlinks a promising solution for networking real-world microgrids. The presented point-to-point dc interlink utilizes two four-quadrant converters: a 40kW 3-phase ac/dc regulating the dc-link voltage to 800V, and a 3-phase dc/ac controlling power flow. These converters, connected via a 20-foot dc cable, interconnect two ac microgrids operating at 480V, each featuring energy storage, photovoltaic generation, and load emulation. Experimental validation employs commercially available off-the-shelf (COTS) converters and real-world data from solar-powered microgrids in Adjuntas, Puerto Rico. To the authors’ knowledge, this work provides the first at-scale experimental validation of dc-interlinks for networked ac microgrids using COTS inverters, demonstrating their practicality and effectiveness in addressing real-world operational challenges.

Ferrari Maglia, Max [ORNL]↗

Cost and Efficiency Analysis for Hybrid AC/DC Distribution System Planning with PV and Battery

Distribution system planning is one of the main tasks for the electric utilities. Cost and energy efficiency are two main concerns in the distribution planning process. In this work, cost and efficiency analyses are conducted for the hybrid AC and DC distribution grids for the planning purposes. The IEEE 34-bus feeder has been applied for the case studies. The investment cost, operation and maintenance cost, replacement cost, etc., have been considered in the life cycle cost analysis. Power losses of both the AC and DC section are calculated with an open source simulation tool, the Open Distribution Simulator Software (OpenDSS). The proposed framework can be applied to quantitatively evaluate the cost and efficiency of hybrid AC and DC distribution grids and help comparing different planning options.

AC/DC hybrid system planning↗

Power Conversion Systems Enabled by SiC BiDFET Device

The BiDirectional Field-Effect Transistor (BiDFET) can enable circuit topologies requiring four quadrant switches, that were earlier designed using discrete combinations of MOSFETs, IGBTs, GaN HEMTs and PiN diodes. The monolithic nature of the BiDFET allows lower device count, smaller switch volume, lower inductance, and simpler packaging, and hence more reliable and commercially viable implementation in power electronics converters. Furthermore, the matrix converter topologies, now feasible using BiDFETs, can eliminate the bulky and unreliable dc link capacitors or inductors required for conventional voltage-source or current-source converters in ac-ac and ac dc applications. The 1.2 kV BiDFET has the potential to disrupt all the applications utilizing 1.2 kV switches, including electric vehicle (EV) drivetrain, bidirectional EV chargers, industrial motor drives, solid-state transformers, datacenter power supplies, elevator drives, dc microgrids, energy storage grid integration, solid-state breakers, etc.

42 ENGINEERING↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗

7.2 kV Three-Port SiC Single-Stage Current-Source Solid-State Transformer With 90 kV Lightning Protection

This article proposes a multiport modular single-stage current-source solid-state transformer (SST) for applications like photovoltaic, energy storage integration, electric vehicle fast charging, data center, etc. The 7.2 kV 50 kVA current-source SST consists of five input-series output-parallel modules, each based on 3.3 kV SiC reverse-blocking MOSFET-plus-diode modules. The proposed SST has some unique features. First, compared to the voltage-source or matrix converter-based SSTs, the current-source SST has a unique advantage of single-stage isolated AC/DC or AC/AC conversion with an inductive DC link, but no medium-voltage (MV) AC experiments have been reported. This article for the first time demonstrates MV AC current-source SST up to 7.5 kV peak. Second, the multiport SST has a buffer port for active power decoupling (APD) or energy storage integration. The double-line-frequency power ripple from single-phase AC grid normally results in a large capacitor size in MV SSTs. The APD scheme is proposed in MV applications for the first time to enable a reduced DC link and the electrolytic capacitor-less SST with high reliability. Third, as a direct grid-connected converter without line-frequency transformer, insulation and protection are critical. A medium-frequency transformer design passes 55 kV basic-insulation level (BIL) and 60 kV high potential dielectrics withstand test with only 0.09% leakage inductance. Importantly, a lightning protection scheme is presented to protect the SST itself from 90 kV BIL impulse. Fourth, the proposed current-source SST topology is a modular soft-switching solid-state transformer (M-S4T) with full-range zero-voltage switching and controlled dv/dt for low electromagnetic interference. Furthermore, these concepts are verified in a three-port M-S4T prototype with forced oil cooling under single-module, stacked-module, steady-state, and dynamic operations.

14 SOLAR ENERGY↗

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Exactness of OPF Relaxation on Three-phase Radial Networks with Delta Connections

Simulations have shown that while semi-definite relaxations of AC optimal power flow (AC-OPF) on three-phase radial networks with only wye connections tend to be exact, the presence of delta connections seem to render them inexact. This paper shows that such inexactness originates from the non-uniqueness of relaxation solutions and numerical errors amplified by the non-uniqueness. This finding motivates two algorithms to recover the exact solution of AC-OPF in unbalanced distribution networks featuring both wye and delta connections. In simulations using IEEE 13, 37 and 123-bus systems, the proposed algorithms provide exact optimal solutions up to numerical precision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Enhancement for Multi-Infeed High-Voltage DC Systems

Composed of multiple two-terminal high-voltage DC (HVDC) transmission systems, a multi-infeed HVDC (MIDC) system exchanges massive power among multiple asynchronous AC systems. However, as an intrinsically cyber-physical system, an MIDC system could suffer from cyber-attacks, leading to massive power mismatches in multiple AC systems, and resulting in catastrophic consequences. Since the sequential responses of an MIDC system and interconnected AC systems are in different timescales, this paper first establishes a two-timescale model to evaluate the sequential impacts caused by cyber-attacks. Then, an event-triggered cyber-defense strategy is proposed to enhance the cybersecurity of an MIDC system by mitigating multiple non-simultaneous cyber-attacks. Whenever new cyber-attack events occur, the proposed cyber-defense strategy, which is mathematically modeled as a mixed-integer quadratic programming problem, is executed on-line and updated in an event-triggered manner. Here, simulation results on an MIDC system demonstrate that the low-cost and almost blind cyber-attacks can cause severe frequency deviations, and the proposed strategy can mitigate multi-cyber-attacks effectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhanced domain dynamics in alternating current poled rhombohedral Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 single crystals

Abstract The understanding of domain dynamics in ferroelectric materials is crucial for optimizing their performance in piezoelectric and electro‐optic applications. Although previous studies have focused on static domain structures and macroscopic characteristics, the time‐resolved approach of domains remains largely unexplored. In this study, we compare the dynamic responses of direct current (DC) and alternating current (AC) poled [001]‐oriented rhombohedral Pb(Mg 1/3 Nb 2/3 )O 3 –PbTiO 3 (PMN–PT) single crystals using X‐ray photon correlation spectroscopy (XPCS) during the application of external electric fields. Our results demonstrate that the AC‐poled sample exhibit enhanced reconfiguration of domain variants in response to driving fields compared to the DC‐poled counterpart, as evidenced by accelerated correlation decay and faster relaxation time. This phenomenon is attributed to enhanced reversible domain wall motion achieved through AC poling, which facilitates field‐induced domain realignment. These findings provide insight into the relationship between dynamics and macroscopic properties in relaxor‐PT single crystals for high‐performance applications.

36 MATERIALS SCIENCE↗

Capturing an elusive but critical element: Natural protein enables actinium chemistry

Actinium-based therapies could revolutionize cancer medicine but remain tantalizing due to the difficulties in studying and limited knowledge of Ac chemistry. Current efforts focus on small synthetic chelators, limiting radioisotope complexation and purification efficiencies. Here, we demonstrate a straightforward strategy to purify medically relevant radiometals, actinium(III) and yttrium(III), and probe their chemistry, using the recently discovered protein, lanmodulin. The stoichiometry, solution behavior, and formation constant of the 228 Ac 3+ -lanmodulin complex and its 90 Y 3+ / nat Y 3+ / nat La 3+ analogs were experimentally determined, representing the first actinium-protein and strongest actinide(III)-protein complex (sub-picomolar Kd) to be characterized. Lanmodulin’s unparalleled properties enable the facile purification recovery of radiometals, even in the presence of >10 +10 equivalents of competing ions and at ultratrace levels: down to 2 femtograms 90 Y 3+ and 40 attograms 228 Ac 3+ . The lanmodulin-based approach charts a new course to study elusive isotopes and develop versatile chelating platforms for medical radiometals, both for high-value separations and potential in vivo applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

A Bilevel Approach for Identifying the Worst Contingencies for Nonconvex Alternating Current Power Systems

We address the bilevel optimization problem of identifying the most critical attacks to an alternating current (AC) power flow network. The upper-level binary maximization problem consists of choosing an attack that is treated as a parameter in the lower-level defender minimization problem. Instances of the lower-level global minimization problem by themselves are NP-hard due to the nonconvex AC power flow constraints, and bilevel solution approaches commonly apply a convex relaxation or approximation to allow for tractable bilevel reformulations at the cost of underestimating some power system vulnerabilities. Our main contribution is to provide an alternative branch-and-bound algorithm whose upper bounding mechanism (in a maximization context) is based on a reformulation that avoids relaxation of the AC power flow constraints in the lower-level defender problem. Lower bounding is provided with semidefinite programming (SDP) relaxed solutions to the lower-level problem. We establish finite termination with guarantees of either a globally optimal solution to the original bilevel problem, or a globally optimal solution to the SDP-relaxed bilevel problem which is included in a vetted list of upper-level attack solutions, at least one of which is a globally optimal solution to the bilevel problem. We demonstrate through computational experiments applied to IEEE case instances both the relevance of our contribution, and the effectiveness of our contributed algorithm for identifying power system vulnerabilities without resorting to convex relaxations of the lower-level problem. We conclude with a discussion of future extensions and improvements.

97 MATHEMATICS AND COMPUTING↗