Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ABLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 685 records · Page 38

Process and structures for fabrication of solar cells with laser ablation steps to form contact holes

Contact holes of solar cells are formed by laser ablation to accomodate various solar cell designs. Use of a laser to form the contact holes is facilitated by replacing films formed on the diffusion regions with a film that has substantially uniform thickness. Contact holes may be formed to deep diffusion regions to increase the laser ablation process margins. The laser configuration may be tailored to form contact holes through dielectric films of varying thickness.

14 SOLAR ENERGY↗

High throughput solar cell ablation system

A solar cell is formed using a solar cell ablation system. The ablation system includes a single laser source and several laser scanners. The laser scanners include a master laser scanner, with the rest of the laser scanners being slaved to the master laser scanner. A laser beam from the laser source is split into several laser beams, with the laser beams being scanned onto corresponding wafers using the laser scanners in accordance with one or more patterns. The laser beams may be scanned on the wafers using the same or different power levels of the laser source.

14 SOLAR ENERGY↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Methods for multiphase laser ablation analysis

Methods of liquid and solid materials analysis by laser induced ablation spectroscopy are disclosed. The liquid and solid materials are analyzed in an instrument having one pulsed laser to produce emissive plasma plumes and ablate solid material. Liquid phase samples are aerosolized before streaming to an analysis zone where they are dissociated into a plasma plume. A large number of sites within solid phase sample structures and be analyzed using a movable x-y-z stage and displayed in a chemical map.

Bol'shakov, Alexander A.↗

Laser ablation sampling system and method

A method and system for sampling a solid sample material can include the step of mounting the sample material on a support. A sample surface is coated with a surface treatment composition in a dry deposition process. A solvent supply conduit for supplying solvent to the sample surface and a solvent exhaust conduit for withdrawing solvent from the sample surface can be provided. Solvent is flowed from the solvent supply conduit to the surface treatment composition and the sample surface such that the solvent contacts the surface treatment composition. A laser beam is directed from a laser source to the sample and the surface treatment composition. The laser beam will ablate the sample and the surface treatment composition in portions intersected by the laser beam. Ablated sample material enters the solvent liquid and will be transported with the solvent away from the sample surface through the solvent exhaust conduit.

Kertesz, Vilmos↗

Spatially tracking carbon through the root-rhizosphere-soil system using laser ablation-IRMS

The intimate relationships between plant roots, rhizosphere, and soil are fostered by the release of organic compounds from the plant into soil through various forms of rhizodeposition and the simultaneous harvestingof inorganic nutrients from the soil to the plant. Here we present a method to spatially track and map the migration of plant-derived carbon (C) through roots into the rhizosphere and surrounding soil using laser ablation-isotope ratio mass spectrometry (LA-IRMS). Weused switchgrass microcosms containing soil from field plots at the Kellogg Biological Station (Hickory Corners, Michigan, USA), which have been cropped with switchgrass since 2008. We used a 13 CO 2 tracerto isotopically label switchgrass plants for two diel cycles and tracked subsequent movement of labeled C using the spatially specific (<100 µm resolution) δ 13 C analysis enabled by LA-IRMS.This approach permitted assessment of variable C flow through different roots and enabled mapping of spatial variability of C allocation to the rhizosphere. Highly 13 C-enriched C (consistent with production during the 13 CO 2 application period) extended ~0.5 – 1 mm from the root into the soil, suggesting that the majority of recent plant-derived C was within this distance of the root after 48 hours. Tracking the physical extent of root exudation into the rhizosphere can help evaluate the localization of plant-microbe interactions in highly variable subsurface environments,and the use of the isotopic label can differentiate freshly fixed C (presumably from root exudates) from other types of subsurface C (e.g., plant necromass and microbial turnover). The LA-IRMS technique mayalso serve as a valuable screening technique to identify areas of high activity for additional microbial or geochemicalassays.

59 BASIC BIOLOGICAL SCIENCES↗

Fast-charging lithium-ion batteries: Synergy of carbon nanotubes and laser ablation

Advancing lithium-ion battery (LiB) technology to achieve 10–15-min extreme fast charging (XFC) while maintaining high energy density and longevity poses a significant challenge. Addressing Li-plating is crucial, as it depletes useable Li, causing deterioration and safety issues. Here, this study explores a holistic approach incorporating Single-Wall Carbon Nanotubes (SWCNTs) and Laser Ablation (LA) to mitigate Li-plating while maintaining high charge acceptance under 10–15-min XFC. SWCNTs enhance the electrical conductivity and mechanical integrity of the positive electrode (PE), reducing overall cell overpotential at high charging rates. Concurrently, LA is applied to negative electrodes (NE) to reduce tortuosity of ion-diffusion pathways and increase surface wettability, improving Li-ion transport. Combining SWCNTs in the PE and LA on the NE, our experimental findings demonstrate a significant reduction in Li-plating and maintained high charge acceptance of ~84.33 % after 800 5C (12 min) charge cycles for cells having PE with ~3.3 mAh cm –2 and NE with 3.9 mAh cm –2 loadings. This study highlights the potential of combining SWCNTs and LA to address Li-plating in LiBs and opens new avenues for designing battery systems capable of achieving 10–15-min XFC.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report for completed IPP Project:"Development of Plasma Ablation for Soft Tissue and Bone Surgery"

ArthroCare is a medical device company that develops, manufactures, and markets an advanced surgical tool, a plasma electro-surgical system for cutting and removing tissue. The hand-held electrical discharge device produces plasma in a biocompatible conductive fluid and tissue to which it is applied during surgery. Its products allow surgeons to operate with increased precision and accuracy, limiting damage to surrounding tissue thereby reducing pain and speeding recovery for the patient. In the past, the design of ArthfoCare's plasma wands has been an empirical undertaking. One goal of this R&D program was to put the phenomena involved on a sound scientific footing, allowing optimization of existing plasma based electro-surgery system technology, and the design and manufacture of new and improved kinds of scalpels, in particular for the surgical cutting of bone. Another important related goal of the program was to develop, through an experimental approach, new plasma wand approaches to the cutting ('shaving') of hard bone tissue. The goals of the CRADA were accomplished - computer models were used to predict important parameters of the plasma discharge and the bone environment, and several different approaches to bone-shaving were developed and demonstrated. The primary goal of the project was to develop and demonstrate an atmospheric-pressure plasma tool that is suitable for surgical use for shaving bone in humans. This goal was accomplished, in fact with several different alternative plasma approaches. High bone ablation speeds were measured. The use of probes ('plasma wand' - the surgical tool) with moving active electrodes was also explored, and there are advantages to this method. Another important feature is that the newly-exposed bone surface have only a very thin necrosis layer; this feature was demonstrated. This CRADA has greatly advanced our understanding of bone removal by atmospheric pressure plasmas in liquid, and puts ArthroCare in a good position to develop the techniques for commercial (surgical) application.

43 PARTICLE ACCELERATORS↗

Titanium Dioxide Nanomaterial Ink Production Through Laser Ablation Synthesis in Solution for Printed Electronics Applications

Flexible and printed electronics have become increasingly popular as they make possible the production of flexible, low-cost, multifunction devices that are unachievable through traditional manufacturing methods. The printed films are significantly impacted and thus limited by the existing ink production process. Herein, an alternate technique of generating high-quality titanium dioxide (TiO 2 ) nanoparticle ink compatible with aerosol jet printing using laser ablation synthesis in solution (LASiS) is showcased. Dynamic light scattering data and transmission electron microscopy confirm the particle size distribution. UV–vis measurements are performed, and the Beer–Lambert relationship is used to determine the concentration of the generated ink. The inks generated at two different repetition rates are compared: 200 kHz and 1 MHz. X-Ray diffraction analysis of the aerosol jet printed thin film post-thermal sintering confirms the grain size and phase purity of the printed thin films. This work demonstrates the effectiveness of the LASiS technique in producing printable nanoparticle inks with little-to-no postprocessing.

36 MATERIALS SCIENCE↗

Transhepatic CT-Guided Radiofrequency Ablation of Adrenal Metastases from Hepatocellular Carcinoma

The prognosis of patients with adrenal metastases from hepatocellular carcinoma (HCC) has been poor, and aggressive treatment of these tumors is mandatory to improve patients' survival. Since adrenalectomy may be difficult to perform after previous surgery of the right liver lobe, other approaches are required to treat the adrenal mass. This report aims at demonstrating the feasibility of CT-guided transhepatic radiofrequency ablation of right adrenal HCC metastases pretreated with chemoembolization in patients unable to undergo surgical resection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image-Guided Radiofrequency Ablation of a Pancreatic Tumor with a New Triple Spiral-Shaped Electrode

Image-guided, minimally invasive treatment modalities have become an area of considerable interest and research during the last few years for the treatment of primary and secondary liver tumors. We report our experience with an unresectable pancreatic tumor, treated with application of radiofrequency ablation under CT guidance that even though a complication occurred during the procedure, had excellent results on follow-up CT scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pulmonary Artery Pseudoaneurysm Related to Radiofrequency Ablation of Lung Tumor

We describe a case of pulmonary artery (PA) pseudoaneurysm related to radiofrequency ablation (RFA) of lung tumor. We performed RFA for a pulmonary epithelioid hemangioendothelioma directly adjacent to a branch of the PA. Seventeen days later, the patient complained of hemoptysis. A chest CT image revealed PA pseudoaneurysm. Transcatheter coil embolization was performed 59 days after RFA. Although PA pseudoaneurysm is rare, with an incidence of 0.2% (1/538 sessions) at our institution, it should be recognized as a risk when treating lung tumors adjacent to a branch of the PA.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Life-Threatening Complication During Percutaneous Ablation of Adrenal Gland Metastasis: Takotsubo Syndrome

A rare life-threatening complication during percutaneous cryoablation of an adrenal gland metastasis from a lung carcinoma is reported. The patient presented hypertensive crisis at the beginning of the thawing cycle, followed by electrocardiographic change which necessitated interruption of the procedure and his transfer to the intensive care unit with suspicion of heart infarct. There was a slight increase in cardiac enzyme levels, and ventricular angiography demonstrated transient hypokinesis-dyskinesis of the mid left ventricular segments without apical involvement, while the coronary arteries showed no significant stenosis on coronarography. These findings led to the diagnosis of Takotsubo cardiomyopathy left ventricular dysfunction syndrome. This is the first case of Takotsubo cardiomyopathy occurring as a complication during percutaneous ablation of an adrenal gland tumor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrasound-Guided Radiofrequency Thermal Ablation of Uterine Fibroids: Medium-Term Follow-Up

Previous studies have shown that radiofrequency thermal ablation (RFA) of uterine fibroids through a percutaneous ultrasound (US)-guided procedure is an effective and safe minimally invasive treatment, with encouraging short-term results. The aim of this study was to assess the results in terms of volume reduction and clinical symptoms improvement in the midterm follow-up of fibroids with a diameter of up to 8 cm. Eleven premenopausal females affected by symptomatic fibroids underwent percutaneous US-guided RFA. Symptom severity and reduction in volume were evaluated at 1, 3, 6, 9, and 12 months. The mean symptom score (SSS) before the procedure was 50.30 (range 31.8-67.30), and the average quality of life (QOL) score value was 62 (range 37.20-86.00). The mean basal diameter was 5.5 cm (range 4.4-8) and the mean volume was 101.5 cm{sup 3} (range 44.58-278 cm{sup 3}). The mean follow-up was 9 months (range 3-12 months). The mean SSS value at the end of the follow-up was 13.38 (range 0-67.1) and the QOL 90.4 (range 43.8-100). At follow-up the mean diameter was 3.0 cm (range 1.20-4.5 cm), and the mean volume was 18 cm{sup 3} (range 0.90-47.6 cm{sup 3}). In 10 of 11 patients we obtained total or partial regression of symptoms. In one case the clinical manifestations persisted and it was thus considered unsuccessful. In conclusion, US-guided percutaneous RFA is a safe and effective treatment even for fibroids up to 8 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Case Report of 20 Lung Radiofrequency Ablation Sessions for 50 Lung Metastases from Parathyroid Carcinoma Causing Hyperparathyroidism

A 47-year-old man presented with multiple lung metastases from parathyroid carcinoma that caused hyperparathyroidism and refractory hypercalcemia. Lung radiofrequency (RF) ablation was repeated to decrease the serum calcium and parathyroid hormone levels and improve general fatigue. Pulmonary resection was combined for lung hilum metastases. The patient is still alive 4 years after the initial RF session. He has received 20 RF sessions for 50 lung metastases during this period.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of Local Progression After Computed Tomography-Guided Percutaneous Radiofrequency Ablation for Unresectable Lung Tumors: 9-Year Experience in a Single Institution

The purpose of this study was to retrospectively determine the local control rate and contributing factors to local progression after computed tomography (CT)-guided radiofrequency ablation (RFA) for unresectable lung tumor. This study included 138 lung tumors in 72 patients (56 men and 16 women; age 70.0 {+-} 11.6 years (range 31-94); mean tumor size 2.1 {+-} 1.2 cm [range 0.2-9]) who underwent lung RFA between June 2000 and May 2009. Mean follow-up periods for patients and tumors were 14 and 12 months, respectively. The local progression-free rate and survival rate were calculated to determine the contributing factors to local progression. During follow-up, 44 of 138 (32%) lung tumors showed local progression. The 1-, 2-, 3-, and 5-year overall local control rates were 61, 57, 57, and 38%, respectively. The risk factors for local progression were age ({>=}70 years), tumor size ({>=}2 cm), sex (male), and no achievement of roll-off during RFA (P < 0.05). Multivariate analysis identified tumor size {>=}2 cm as the only independent factor for local progression (P = 0.003). For tumors <2 cm, 17 of 68 (25%) showed local progression, and the 1-, 2-, and 3-year overall local control rates were 77, 73, and 73%, respectively. Multivariate analysis identified that age {>=}70 years was an independent determinant of local progression for tumors <2 cm in diameter (P = 0.011). The present study showed that 32% of lung tumors developed local progression after CT-guided RFA. The significant risk factor for local progression after RFA for lung tumors was tumor size {>=}2 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗