Bridging the Gap Between Pure and Mixed-Gas Performance of Thin-Film Composite Membranes
This study examines the influence of cell design on mixed-gas testing with PolyActive™ TFC membranes, featuring pure-gas CO₂ permeance of 1700–3100 GPU, representative of state-of-the-art CO₂/N₂ separation membranes. By designing and 3D-printing a counter-current permeation cell with optimized flow efficiency, we achieved a 33–41% increase in mixed-gas CO₂ permeance compared to traditional cells. Additionally, a comparison of sweep-gas and vacuum permeation methods revealed that vacuum operation mitigates downstream polarization, enhancing mixed-gas CO₂ permeance by 41%. These results underscore the critical role of permeation cell design and testing methods in accurately evaluating membrane performance, with significant implications for scaling up TFC membranes and optimizing industrial processes.