Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “verifications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

New Developments and Applications of Superheated Emulsions: Warhead Verification and Special Nuclear Material Interdiction

In recent years, neutron detection with superheated emulsions has received renewed attention thanks to improved detector manufacturing and read-out techniques, and thanks to successful applications in warhead verification and special nuclear material (SNM) interdiction. Detectors are currently manufactured with methods allowing high uniformity of the drop sizes, which in turn allows the use of optical read-out techniques based on dynamic light scattering. Furthermore, small detector cartridges arranged in 2D matrices are developed for the verification of a declared warhead without revealing its design. For this application, the enabling features of the emulsions are that bubbles formed at different times cannot be distinguished from each other, while the passive nature of the detectors avoids the susceptibility to electronic snooping and tampering. Large modules of emulsions are developed to detect the presence of shielded special nuclear materials hidden in cargo containers ‘interrogated’ with high energy X-rays. In this case, the enabling features of the emulsions are photon discrimination, a neutron detection threshold close to 3 MeV and a rate-insensitive read-out.

d’Errico, Francesco↗

Neutron spectrometry for UF 6 enrichment verification in storage cylinders

Verification of declared UF 6 enrichment and mass in storage cylinders is of great interest in nuclear material nonproliferation. Nondestructive assay (NDA) techniques are commonly used for safeguards inspections to ensure accountancy of declared nuclear materials. Common NDA techniques used include gamma-ray spectrometry and both passive and active neutron measurements. In the present study, neutron spectrometry was investigated for verification of UF 6 enrichment in 30B storage cylinders based on an unattended and passive measurement approach. MCNP5 and Geant4 simulated neutron spectra, for selected UF 6 enrichments and filling profiles, were used in the investigation. The simulated neutron spectra were analyzed using principal component analysis (PCA). The PCA technique is a well-established technique and has a wide area of application including feature analysis, outlier detection, and gamma-ray spectral analysis. Results obtained demonstrate that neutron spectrometry supported by spectral feature analysis has potential for assaying UF 6 enrichment in storage cylinders. The results from the present study also showed that difficulties associated with the UF 6 filling profile and observed in other unattended passive neutron measurements can possibly be overcome using the approach presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification assessment of piston boundary conditions for Lagrangian simulation of compressible flow similarity solutions

This work is concerned with the use of similarity solutions of the compressible flow equations as benchmarks or verification test problems for finite-volume compressible flow simulation software. In practice, this effort can be complicated by the infinite spatial/temporal extent of many candidate solutions or “test problems.” Methods can be devised with the intention of ameliorating this inconsistency with the finite nature of computational simulation; the exact strategy will depend on the code and problem archetypes under investigation. For example, self-similar shock wave propagation can be represented in Lagrangian compressible flow simulations as rigid boundary-driven flow, even if no such “piston” is present in the counterpart mathematical similarity solution. The purpose of this work is to investigate in detail the methodology of representing self-similar shock wave propagation as a piston-driven flow in the context of various test problems featuring simple closed-form solutions of infinite spatial/temporal extent. The closed-form solutions allow for the derivation of similarly closed-form piston boundary conditions (BCs) for use in Lagrangian compressible flow solvers. Finally, the consequences of utilizing these BCs (as opposed to directly initializing the self-similar solution in a computational spatial grid) are investigated in terms of common code verification analysis metrics (e.g., shock strength/position errors and global convergence rates).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The 2014 Sandia Verification and Validation Challenge: Problem statement

This paper presents a case study in utilizing information from experiments, models, and verification and validation (V&V) to support a decision. It consists of a simple system with data and models provided, plus a safety requirement to assess. The goal is to pose a problem that is flexible enough to allow challengers to demonstrate a variety of approaches, but constrained enough to focus attention on a theme. This was accomplished by providing a good deal of background information in addition to the data, models, and code, but directing the participants' activities with specific deliverables. In this challenge, the theme is how to gather and present evidence about the quality of model predictions, in order to support a decision. This case study formed the basis of the 2014 Sandia V&V Challenge Workshop and this resulting special edition of the ASME Journal of Verification, Validation, and Uncertainty Quantification.

42 ENGINEERING↗

The Sedov Blast Wave as a Radial Piston Verification Test

The Sedov blast wave is of great utility as a verification problem for hydrodynamic methods. The typical implementation uses an energized cell of finite dimensions to represent the energy point source. We avoid this approximation by directly finding the effects of the energy source as a boundary condition (BC). Furthermore, the proposed method transforms the Sedov problem into an outward moving radial piston problem with a time-varying velocity. A portion of the mesh adjacent to the origin is removed and the boundaries of this hole are forced with the velocities from the Sedov solution. This verification test is implemented on two types of meshes, and convergence is shown. Our results from the typical initial condition (IC) method and the new BC method are compared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Verification Studies for the Noh Problem using Non-ideal Equations of State and Finite Strength Shocks

We present that the Noh verification test problem is extended beyond the commonly studied ideal gamma-law gas to more realistic equations of state (EOSs) including the stiff gas, the Noble-Abel gas, and the Carnahan-Starling EOS for hard-sphere fluids. Self-similarity methods are used to solve the Euler compressible flow equations, which in combination with the Rankine-Hugoniot jump conditions provide a tractable general solution. This solution can be applied to fluids with EOSs that meet criterion such as it being a convex function and having a corresponding bulk modulus. For the planar case the solution can be applied to shocks of arbitrary strength, but for cylindrical and spherical geometries it is required that the analysis be restricted to strong shocks. Finally, the exact solutions are used to perform a variety of quantitative code verification studies of the Los Alamos National Laboratory Lagrangian hydrocode FLAG.

42 ENGINEERING↗

Verification and Validation of the FLAG Hydrocode for Impact Cratering Simulations

Verification and validation (V&V) are necessary processes to ensure accuracy of the computational methods used to solve problems key to vast numbers of applications and industries. Simulations are essential for addressing impact cratering problems, because these problems often exceed experimental capabilities. We show that the free Lagrange (FLAG) hydrocode, developed at Los Alamos National Laboratory (Los Alamos, NM), can be used for impact cratering simulations by verifying FLAG against two analytical models of aluminum-on-aluminum impacts at different impact velocities and validating FLAG against a glass-into-water laboratory impact experiment. Our verification results show good agreement with the theoretical maximum pressures, with relative errors as low in magnitude as 1.00%. Our validation results demonstrate FLAG's ability to model various stages of impact cratering, with crater radius relative errors as low as 3.48% and crater depth relative errors as low as 0.79%. Our mesh resolution study shows that FLAG converges at resolutions low enough to reduce the required computation time from about 28 h to about 25 min. We anticipate that FLAG can be used to model larger impact cratering problems with increased accuracy and decreased computational cost on current systems relative to other hydrocodes tested by Pierazzo et al. (2008, “Validation of Numerical Codes for Impact and Explosion Cratering: Impacts on Strengthless and Metal Targets,” MAPS, 43(12), pp. 1917–1938).

97 MATHEMATICS AND COMPUTING↗

Verification, Validation, and Uncertainty Quantification in Thermal Hydraulics, Freeman Scholar Lecture (2019)

Engineering problems are generally solved by analytical models or computer codes. These models, in addition to conservation equations, also include many empirical relationships and approximate numerical methods. Each of these components contributes to the uncertainty in the prediction. A systematic approach to judge the applicability of the code to the intended application is needed. It starts from verification of implementation of formulation in the code, identification of important phenomena, finding relevant tests with quantified uncertainty for these phenomena, and validation of the code by comparing predictions with the relevant test data. The relevant tests must address phenomena as expected in the intended application. In case of small size or limited condition tests, the scaling analyses are needed to assess the relevancy of the tests. Finally, a statement of uncertainty in the prediction is needed. Systematic approaches are described to aggregate uncertainties from different components of the code for intended application. Here, verification, validation, and uncertainty quantifications (VVUQs) are briefly described.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Code Verification of Multiple Physics-Fidelity Models in Hypersonic Aerodynamics

Hypersonic aerodynamics models exist across a range of physics fidelities with associated computational expenses. These models may be run independently or in a multifidelity framework that leverages their complementary strengths of speed for lower-fidelity and accuracy for higher-fidelity models. This work presents applied code verification of two lower-fidelity models contained within the Sandia hypersonic aerodynamics code. Each model has a different form that requires individualized verification approaches, including comparison to analytical solutions as well as manufactured solutions with order-of-accuracy testing. In conclusion, results of this effort include the identification and resolution of code errors and shortcomings, as well as the demonstration of code correctness and consistency for both models.

Aerodynamics↗

Verification of a Numerical Model of the Offshore Wind Turbine From the Alpha Ventus Wind Farm Within OC5 Phase III

The main objective of the Offshore Code Comparison Collaboration Continuation, with Correlation (OC5) project, is validation of aero-hydro-servo-elastic simulation tools for offshore wind turbines (OWTs) through comparison of simulated results to the response data of physical systems. Phase III of the OC5 project analyzes the Senvion 5M wind turbine supported by the OWEC Quattropod from the alpha ventus offshore wind farm. This paper shows results of the verification of the OWT models (code-to-code comparison). A subsequent publication will focus on their validation (comparison of simulated results to measured physical system response data). Based on the available data, the participants of Phase III set up numerical models of the OWT in their simulation tools. It was necessary to verify and to tune these models. The verification and tuning were performed against an OWT model available at the University of Stuttgart - Stuttgart Wind Energy (SWE) and documentation provided by Senvion and OWEC Tower. A very good match was achieved between the results from the reference SWE model and models set up by OC5 Phase III participants.

17 WIND ENERGY↗

TomoTherapy MLC verification using exit detector data

Purpose: Treatment delivery verification (DV) is important in the field of intensity modulated radiation therapy (IMRT). While IMRT and image guided radiation therapy (IGRT), allow us to create more conformal plans and enables the use of tighter margins, an erroneously executed plan can have detrimental effects on the treatment outcome. The purpose of this study is to develop a DV technique to verify TomoTherapy's multileaf collimator (MLC) using the onboard mega-voltage CT detectors. Methods: The proposed DV method uses temporal changes in the MVCT detector signal to predict actual leaf open times delivered on the treatment machine. Penumbra and scattered radiation effects may produce confounding results when determining leaf open times from the raw detector data. To reduce the impact of the effects, an iterative, Richardson-Lucy (R-L) deconvolution algorithm is applied. Optical sensors installed on each MLC leaf are used to verify the accuracy of the DV technique. The robustness of the DV technique is examined by introducing different attenuation materials in the beam. Additionally, the DV technique has been used to investigate several clinical plans which failed to pass delivery quality assurance (DQA) and was successful in identifying MLC timing discrepancies as the root cause. Results: The leaf open time extracted from the exit detector showed good agreement with the optical sensors under a variety of conditions. Detector-measured leaf open times agreed with optical sensor data to within 0.2 ms, and 99% of the results agreed within 8.5 ms. These results changed little when attenuation was added in the beam. For the clinical plans failing DQA, the dose calculated from reconstructed leaf open times played an instrumental role in discovering the root-cause of the problem. Throughout the retrospective study, it is found that the reconstructed dose always agrees with measured doses to within 1%. Conclusions: The exit detectors in the TomoTherapy treatment systems can provide valuable information about MLC behavior during delivery. A technique to estimate the TomoTherapy binary MLC leaf open time from exit detector signals is described. This technique is shown to be both robust and accurate for delivery verification.

60 APPLIED LIFE SCIENCES↗

SU-E-J-46: Development of a Compton Camera Prototype for Online Range Verification of Laser-Accelerated Proton Beams

Purpose: Development of a photon detection system designed for online range verification of laser-accelerated proton beams via prompt-gamma imaging of nuclear reactions. Methods: We develop a Compton camera for the position-sensitive detection of prompt photons emitted from nuclear reactions between the proton beam and biological samples. The detector is designed to be capable to reconstruct the photon source origin not only from the Compton scattering kinematics of the primary photon, but also to allow for tracking of the Compton-scattered electrons. Results: Simulation studies resulted in the design of the Compton camera based on a LaBr{sub 3}(Ce) scintillation crystal acting as absorber, preceded by a stacked array of 6 double-sided silicon strip detectors as scatterers. From the design simulations, an angular resolution of ≤ 2° and an image reconstruction efficiency of 10{sup −3} −10{sup −5} (at 2–6 MeV) can be expected. The LaBr{sub 3} crystal has been characterized with calibration sources, resulting in a time resolution of 273 ps (FWHM) and an energy resolution of about 3.8% (FWHM). Using a collimated (1 mm diameter) {sup 137}Cs calibration source, the light distribution was measured for each of 64 pixels (6×6 mm{sup 2}). Data were also taken with 0.5 mm collimation and 0.5 mm step size to generate a reference library of light distributions that allows for reconstructing the interaction position of the initial photon using a k-nearest neighbor (k-NN) algorithm developed by the Delft group. Conclusion: The Compton-camera approach for prompt-gamma detection offers promising perspectives for ion beam range verification. A Compton camera prototype is presently being developed and characterized in Garching. Furthermore, an arrangement of, e.g., 4 camera modules could even be used in a ‘gamma-PET’ mode to detect delayed annihilation radiation from positron emitters in the irradiation interrupts (with improved performance in the presence of an additional third (prompt) photon (as in 10C and 14O). This work was supported by the DFG Cluster of Excellence MAP (Munich-Centre for Advanced Photonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-213: Initial Experience with VMAT Plan and Delivery Verification Using a DICOM-RT Framework and Linac Delivery Log Files

Purpose: Mobius3D/MobiusFX (M3D/MFX), a commercial DICOM-RT based plan and delivery verification system, was used to compare calculated and delivered volumetric modulated arc therapy (VMAT) dose distributions using TrueBeam delivery log files (TrajectoryLogs). Methods: M3D/MFX utilizes measured linac commissioning data to generate institution specific beam models for evaluating planned and delivered dose distributions. 30 RapidArc prostate plans and 30 head and neck SmartArc plans were used in this study. For every plan, CT images, contoured structure sets, RT-plan, and RT-dose files were exported to M3D, which recalculated the patients’ planning CT dose distributions using a collapsed-cone-convolutionsuperposition algorithm. MFX utilized the acquired TrajectoryLogs to compute patients’ delivered dose distributions based on actual treatment delivery parameters. The agreement between computed and delivered dose distributions was evaluated utilizing a (3%, 3mm) global 3D-gamma analysis and dose-volume histogram changes for targets and organs at risk. Results: Excellent 3D-gamma agreements were observed for all VMAT plans. On average, for computed and delivered RapidArc and SmartArc plans the gamma passing rates were (99.0%±1.4%) and (96.8%±1.8%), respectively. The average difference for primary target prescription dose percent-coverage between calculated and delivered plans was (− 0.09%±2.52%) for RapidArc and (−2.71%±4.62%) for SmartArc cases. Similarly, the planning target mean dose differences were (1.38%±0.96%) for RapidArc and (1.17%±0.72%) for SmartArc plans. For the prostate plans, the calculated and delivered variations of the maximum dose for a 2cc volume for bladder and rectum were (1.32%±1.26%) and (0.65%±1.44%), respectively. The spinal-cord 2cc maximum dose differences of (3.26%±1.68%) were observed for the SmartArc plans. Conclusions: Clinical quality assurance practice based on linac treatment log files for verification of delivered 3D dose distributions in the patients’ geometries represents a paradigm shift from dose measurements in a phantom. This approach captures treatment planning beam modeling differences as well as the linac uncertainties during treatment delivery of the plan.

60 APPLIED LIFE SCIENCES↗

SU-E-T-351: Verification of Monitor Unit Calculation for Lung Stereotactic Body Radiation Therapy Using a Secondary Independent Planning System

Purpose: To compare isocenter (IC) dose between X-ray Voxel Monte Carlo (XVMC) and Acuros XB (AXB) as part of an independent verification of monitor unit (MU) calculation for lung stereotactic body radiation therapy (SBRT) using a secondary independent treatment planning system (TPS). Methods: Treatment plans of 110 lesions from 101 patients who underwent lung SBRT with Vero4DRT (Mitsubishi Heavy Industries, Ltd., Japan, and BrainLAB, Feldkirchen, Germany) were evaluated retrospectively. Dose distribution was calculated with X-ray Voxel Monte Carlo (XVMC) in iPlan 4.5.1 (BrainLAB, Feldkirchen, Germany) on averaged intensity projection images. A spatial resolution and mean variance were 2 mm and 2%, respectively. The clinical treatment plans were transferred from iPlan to Eclipse (Varian Medical Systems, Palo Alto, CA, USA), and doses were recalculated with well commissioned AXB ver. 11.0.31 while maintaining the XVMC-calculated MUs and beam arrangement. Dose calculations were made in the dose-to-medium dose reporting mode with the calculation grid size of 2.5 mm. The mean and standard deviation (SD) of the IC dose difference between XVMC and AXB were calculated. The tolerance level was defined as |mean|+2SD. Additionally, the relationship between IC dose difference and the size of planning target volume (PTV) or computed tomography (CT) value of internal target volume (ITV) was evaluated. Results: The mean±SD of the IC dose difference between XVMC and AXB was −0.32±0.73%. The tolerance level was 1.8%. Absolute IC dose differences exceeding the tolerance level were observed in 3 patients (2.8%). There were no strong correlations between IC dose difference and PTV size (R=−0.14) or CT value of ITV (R=−0.33). Conclusion: The present study suggested that independent verification of MU calculation for lung SBRT using a secondary TPS is useful.

60 APPLIED LIFE SCIENCES↗

TH-E-BRE-11: Adaptive-Beamlet Based Finite Size Pencil Beam (AB-FSPB) Dose Calculation Algorithm for Independent Verification of IMRT and VMAT

Purpose: In current IMRT and VMAT settings, the use of sophisticated dose calculation procedure is inevitable in order to account complex treatment field created by MLCs. As a consequence, independent volumetric dose verification procedure is time consuming which affect the efficiency of clinical workflow. In this study, the authors present an efficient Pencil Beam based dose calculation algorithm that minimizes the computational procedure while preserving the accuracy. Methods: The computational time of Finite Size Pencil Beam (FSPB) algorithm is proportional to the number of infinitesimal identical beamlets that constitute the arbitrary field shape. In AB-FSPB, the dose distribution from each beamlet is mathematically modelled such that the sizes of beamlets to represent arbitrary field shape are no longer needed to be infinitesimal nor identical. In consequence, it is possible to represent arbitrary field shape with combinations of different sized and minimal number of beamlets. Results: On comparing FSPB with AB-FSPB, the complexity of the algorithm has been reduced significantly. For 25 by 25 cm2 squared shaped field, 1 beamlet of 25 by 25 cm2 was sufficient to calculate dose in AB-FSPB, whereas in conventional FSPB, minimum 2500 beamlets of 0.5 by 0.5 cm2 size were needed to calculate dose that was comparable to the Result computed from Treatment Planning System (TPS). The algorithm was also found to be GPU compatible to maximize its computational speed. On calculating 3D dose of IMRT (∼30 control points) and VMAT plan (∼90 control points) with grid size 2.0 mm (200 by 200 by 200), the dose could be computed within 3∼5 and 10∼15 seconds. Conclusion: Authors have developed an efficient Pencil Beam type dose calculation algorithm called AB-FSPB. The fast computation nature along with GPU compatibility has shown performance better than conventional FSPB. This completely enables the implantation of AB-FSPB in the clinical environment for independent volumetric dose verification.

60 APPLIED LIFE SCIENCES↗

Feasibility study of a dual detector configuration concept for simultaneous megavoltage imaging and dose verification in radiotherapy

Purpose: To test the feasibility of a dual detector concept for comprehensive verification of external beam radiotherapy. Specifically, the authors test the hypothesis that a portal imaging device coupled to a 2D dosimeter provides a system capable of simultaneous imaging and dose verification, and that the presence of each device does not significantly detract from the performance of the other. Methods: The dual detector configuration comprised of a standard radiotherapy electronic portal imaging device (EPID) positioned directly on top of an ionization-chamber array (ICA) with 2 cm solid water buildup material (between EPID and ICA) and 5 cm solid backscatter material. The dose response characteristics of the ICA and the imaging performance of the EPID in the dual detector configuration were compared to the performance in their respective reference clinical configurations. The reference clinical configurations were 6 cm solid water buildup material, an ICA, and 5 cm solid water backscatter material as the reference dosimetry configuration, and an EPID with no additional buildup or solid backscatter material as the reference imaging configuration. The dose response of the ICA was evaluated by measuring the detector’s response with respect to off-axis position, field size, and transit object thickness. Clinical dosimetry performance was evaluated by measuring a range of clinical intensity-modulated radiation therapy (IMRT) beams in transit and nontransit geometries. The imaging performance of the EPID was evaluated quantitatively by measuring the contrast-to-noise ratio (CNR) and spatial resolution. Images of an anthropomorphic phantom were also used for qualitative assessment. Results: The measured off-axis and field size response with the ICA in both transit and nontransit geometries for both dual detector configuration and reference dosimetry configuration agreed to within 1%. Transit dose response as a function of object thickness agreed to within 0.5%. All IMRT test patterns and clinical IMRT beams had gamma pass rates of ≥98% at 2%/2 mm criteria. In terms of imaging performance, the measured CNR and spatial resolution (f{sub 50}) were 263.23 ± 24.85 and 0.4025 ± 1.25 × 10{sup −3} for dual detector configuration and 324 ± 26.65 and 0.4141 ± 1.14 × 10{sup −3} for reference imaging configuration, respectively. The CNR and spatial resolution were quantitatively worse in the dual detector configuration due to the additional backscatter. The difference in imaging performance was not visible in qualitative assessment of phantom images. Conclusions: Combining a commercially available ICA dosimetry device with a conventional EPID did not significantly detract from the performance of either device. Further improvements in imaging performance may be achieved with an optimized design. This study demonstrates the feasibility of a dual detector concept for simultaneous imaging and dosimetry in radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-E-J-138: On the Ion Beam Range and Dose Verification in Hadron Therapy Using Sound Waves

Purpose: Accurate range verification is of great importance to fully exploit the potential benefits of ion beam therapies. Current research efforts on this topic include the use of PET imaging of induced activity, detection of emerging prompt gamma rays or secondary particles. It has also been suggested recently to detect the ultrasound waves emitted through the ion energy absorption process. The energy absorbed in a medium is dissipated as heat, followed by thermal expansion that leads to generation of acoustic waves. By using an array of ultrasound transducers the precise spatial location of the Bragg peak can be obtained. The shape and intensity of the emitted ultrasound pulse depend on several variables including the absorbed energy and the pulse length. The main objective of this work is to understand how the ultrasound wave amplitude and shape depend on the initial ion energy and intensity. This would help guide future experiments in ionoacoustic imaging. Methods: The absorbed energy density for protons and carbon ions of different energy and field sizes were obtained using Fluka Monte Carlo code. Subsequently, the system of coupled equations for temperature and pressure is solved for different ion pulse intensities and lengths to obtain the pressure wave shape, amplitude and spectral distribution. Results: The proposed calculations show that the excited pressure wave amplitude is proportional to the absorbed energy density and for longer ion pulses inversely proportional to the ion pulse duration. It is also shown that the resulting ionoacoustic pressure distribution depends on both ion pulse duration and time between the pulses. Conclusion: The Bragg peak localization using ionoacoustic signal may eventually lead to the development of an alternative imaging method with sub-millimeter resolution. It may also open a way for in-vivo dose verification from the measured acoustic signal.

60 APPLIED LIFE SCIENCES↗

SU-E-T-634: Pre-Verification of FFF Prostate VMAT Plans with Gamma Method and DVHs Reconstructed Based On Measurements with 2D-ARRAY (PTW 1500) and OCTAVIUS 4D

Purpose: The aim of this work was to characterize the clinical correctness of FFF prostate treatment VMAT plans based on analysis of DVHs reconstructed from pre-verification 2D-arrays measurements. Methods: The new 2D ion chamber array 1500 with rotational phantom cylindrical Octavius 4D and Verisoft 6.1 software with DVH option (PTW, Freiburg) were used to determine the clinical usefulness of the treatment plans. Ten patients treated with VMAT high-fractionated (2 fraction x 7,5 Gy) FFF prostate plans (TrueBeam, Varian) were analyzed using the 3D gamma analysis by local dose method with a 5% threshold for various tolerance parameters DTA [mm] and DD [%] were 1%/1, 2%/2, 3%/3. Additional, based on the measurements of irradiation dose distributions and patients’ CT scans with contoured structures of organs, the DVHs were reconstructed using a software. The obtained DVHs were compared to planned dose distributions and the deviations were analysed with parameters: for CTV D50, D98, D2, and D25, D50, Dmax for OARs — rectum, bladder and left/right femoral heads. Results: The analyzed treatment plans passed gamma criteria (3/3%; 95%), the results obtained were as follow: mean value and standard deviation of gamma score for criteria (DTA[mm]/DD[%]): 1/1% (L53.3±3.2); 2/2% (L87.0±2.2); 3/3% (L97.5±0.9). In the DVH analysis, the highest differences were observed for OARs (especially for bladder): the mean percentage differences values for rectum, bladder and left/right femoral heads were: D25 (1.67; 6.83)%, D50 (0.18; 7.18; 1.53; 0.30)%, Dmax (−0.84; −1.64; 0.37; −4.63)%, respectively. For the CTV mean relative deviations for proper parameters were in good agreement with TPS: D98 (0.95±2.21)%, D50 (1.93±0.67)%, D2 (1.76±0.76)%. Conclusion: The gamma method is recommended tool for pre-verification analysis of correctness of treatment plans. Moreover, the scrutiny checking with reconstructed DVH gives additional, clinical information about quality of plan, especially about coverage of CTV and sparing of health tissues.

62 RADIOLOGY AND NUCLEAR MEDICINE↗