Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “tunable”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Subresolution imaging - Use of wavelength and angular diversity techniques

The paper demonstrates the possibility of using an illumination system tunable in angle or wavelength to determine the amplitude and height structure of an object within the resolution cell defined by the resolving power of some imaging system. It is noted that since the value of the electric field at a point on the image of an object varies with the wavelength or angle of illumination on the object, the Fourier transform of this variation provides directly the amplitude and phase structure of the object within the resolution cell corresponding to the image point of interest. This Fourier transform is calculated, and it is shown that the transform of the electric-field intensity with respect to the inverse wavelength dimension is simply the autocorrelation of the electric-field variation with wavelength. Practical techniques that can be employed to measure the subresolution detail of an object are briefly discussed.

Jain, A.↗

Dimensional stability of fused silica, Invar, and several ultralow thermal expansion materials

A method is developed for testing the long-term dimensional stability of an iodine-stabilized He-Ne laser, using a technique whereby thermal expansion coefficients are measured by forming a Fabry-Perot etalon from the sample and monitoring the optical resonant frequencies with tunable sidebands impressed on a laser beam from a frequency-stabilized He-Ne laser. A change of 1 ppm over a 3-yr period on the part of fused silica dimensions and the differential thermal expansion of Invar LR-35 and Super Invar materials are noted. The method is of interest for the metrology of extremely stable structures such as telescopes and optical resonators.

Berthold, J. W., III↗

Optoacoustic measurements of water vapor absorption at selected CO laser wavelengths in the 5-micron region

Measurements of water vapor absorption were taken with a resonant optoacoustical detector (cylindrical pyrex detector, two BaF2 windows fitted into end plates at slight tilt to suppress Fabry-Perot resonances), for lack of confidence in existing spectral tabular data for the 5-7 micron region, as line shapes in the wing regions of water vapor lines are difficult to characterize. The measurements are required for air pollution studies using a CO laser, to find the differential absorption at the wavelengths in question due to atmospheric constituents other than water vapor. The design and performance of the optoacoustical detector are presented. Effects of absorption by ambient NO are considered, and the fixed-frequency discretely tunable CO laser is found suitable for monitoring urban NO concentrations in a fairly dry climate, using the water vapor absorption data obtained in the study.

Menzies, R. T.↗

Ozone spectroscopy with a CO2 waveguide laser

Ozone spectral measurements were conducted with a waveguide CO2 laser, which was continuously tunable over a + or - 450-MHz region, about several lines in the P-branch of the band near the 9.5-micron wavelength region. A passively stabilized low-pressure CO2 laser was also used to provide reference CO2 frequencies. The frequencies of several ozone lines were determined in the nu-3 band, which are near CO2 laser line frequencies in the 9.5-micron wavelength region. The absolute measurement accuracy is estimated to be + or - 6 MHz, and the measurements indicate that the ozone line frequencies listed in currently available spectral compilations are 0.003-0.006 per cm too high. The size of this error is small by conventional IR standards, but extremely important when CO2 laser instruments are used to monitor stratospheric ozone, where line widths in this spectral region are typically 0.001/cm. Empirically determined absorption curves must be constructed in order to calibrate laser differential absorption instrument properly when low-altitude ozone measurements are conducted.

Menzies, R. T.↗

A 230-GHz radiometer system employing a second-harmonic mixer

A radiometer system for use in the 1.3 mm region has been constructed and used for radio astronomical observations. A second-harmonic mixer employing a single Schottky diode downconverts the incident power to an IF frequency of about 1400 MHz. The measured double-sideband system noise temperature is 6000 K (noise figure = 13 dB) and the double-sideband mixer conversion loss is calculated to be 10 dB. The mixer is tunable over a range of at least 15 GHz.

Goldsmith, P. F.↗

Recent advances in birefringent filters

In the past several years, important developments have been made in the construction and theory of birefringent filters. Tunable filters that operate from 4500 to 7000 A with full widths at half maximum of 0.05 A and maximum transmissions of almost 20 percent have been constructed. Inexpensive large-aperture (at least 15 cm) achromatic waveplates have been fabricated which allow full use of resolution-solid angle products that are 100 times that of Fabry-Perots and 10,000 times that of grating systems.

Title, A. M.↗

High resolution absorption cross sections for the A2Pi-X2Pi system of ClO

High-resolution ultraviolet absorption cross-sections for the ClO molecule are obtained, with the aim of facilitating studies of ozone depletion resulting from the injection of chlorofluorocarbons into the atmosphere. The spectroscopic analysis, which involves a frequency-doubled tunable dye laser with a bandwidth of 0.015 A, is described. Studies of the rotational lines of the ClO A 2Pi 3/2-X2Pi 3/2 9-10 band were conducted. Peak cross-sections for the P and R lines of the 9-0 band are found to be 10.0, 9.6, 8.6, 10.6, 10.3, and 9.2 times ten to the negative seventeenth power cm squared, with estimated accuracy of plus or minus 25%. Problems in distinguishing between Cl-35 and Cl-37 absorption are also considered.

Wine, P. H.↗

An infrared upconverter for astronomical imaging

An imaging upconverter has been constructed which is suitable for use in the study of the thermal 10-micron radiation from astronomical sources. The infrared radiation is converted to visible radiation by mixing in a 1-cm-long proustite crystal. The phase-matched 2-kayser bandpass is tunable from 9 to 11 microns. The conversion efficiency is 2 by 10 to the -7th power and the field of view of 40 arc seconds on the sky contains several hundred picture elements, approximately diffraction-limited resolution in a large telescope. The instrument has been used in studies of the sun, moon, Mercury, and VY Canis Majoris.

Boyd, R. W.↗

Remote infrared spectroscopy of the earth

The infrared reflexion-spectra of minerals and rocks are used for remote sensing of targets. The reflexion-spectra of silicate rocks vary quite significantly from mineral to mineral in the wave length region from 8 to 12 micrometers. The rock forming minerals like quartz, feldspar, mica and the clay minerals show very different spectral shapes and positions of their maximum of the spectral reflexion. The presence of a good atmospherical window in that spectral region makes the method of differential-reflexion measurement feasible, for remote sensing application. A tunable CO2-laser was used as transmitter for infrared radiation. Laboratory tests showed the feasibility of the method under different simulated environmental conditions. Because of the very narrow bandwidth of the laser-emission lines, reflexion-spectra with extremely high spectral resolution were obtained.

Steinmann, C. R.↗

Broadband photoexcitation of lasers

Existing techniques are reviewed and novel approaches for broadband photoexcitation of lasers are discussed. This subject is of interest because of the emergence of future intense near equilibrium and blackbody sources, such as the gas core reactor, and electric discharge plasma devices, which are the key to the development of intense broadband radiation sources. The possible use of radiation from solar concentrators in space also fits into this general area. The varied use of photoexcitation of lasers are discussed ranging over direct optical pumping, photodissociation, and photoreionization. In addition, the new uses of laser transitions and chemical reactions is shown. This is accomplished through multiline operation of high pressure tunable lasers which can use the broadband radiation for multiphoton excitation.

Hess, R. V.↗

Simultaneous determination of rotational and translational temperatures of OH/2 Pi/ in a gas discharge

A simultaneous determination of the rotational and translational temperatures of OH(2 Pi) in a water-vapor discharge is reported. These temperatures were determined by measuring the strength and line shape of the absorption lines in the 2 Pi (v = 0) - 2 Sigma(+) (v = 0) transitions of OH using a CW tunable laser. It was found that the rotational distribution was thermalized, but the corresponding rotational temperature was much lower than the translational temperature. Possible implications of these results are discussed.

Wang, C. C.↗

A quantum yield determination of O/1D/ production from ozone via laser flash photolysis

The quantum yield of electronically excited atomic oxygen produced from ozone photolysis was measured at 298 K from wavelengths of 293.0 to 316.5 nm. The reaction of the atomic oxygen with N2O to form excited NO2 was used to monitor the O production; a frequency-doubled flashlamp-pumped dye laser which provided tunable ultraviolet in the desired spectral region with 0.1-nm linewidth served as the photolysis source. The atomic oxygen quantum yield was found to be constant below 300 nm, with a sharp decrease centered at 308 nm and a diminution to less than one tenth of the constant value by 313.5 nm.

Philen, D. L.↗

Deuterated ammonia toward the Orion Nebula

The detection of transitions in NH2D at 85926.2 and 110153.4 MHz from the Orion molecular cloud is reported. An 11-m radio telescope with an 80-120 GHz cooled Cassegrain receiver and a tunable quasi-optical rejection filter was used in the investigations. Equations of statistical equilibrium for the lowest 34 energy levels of NH2D were solved. It seems unlikely that the observed lines arise in the very extended CO cloud. However, they could originate either in the molecular 'ridge' or the unresolved (Kleinmann-Low) core of the cloud or both. A column density of about 50 trillion/sq cm is deduced. The NH2D spectra, with 1 MHz resolution, are shown in a graph. Using previously reported column densities for NH3, a value of 0.05 with an estimated maximum uncertainty factor of 10 is found for the ratio NH2D/NH3.

Rodriguez Kuiper, E. N.↗

Atmospheric monitoring using heterodyne detection techniques

Both passive and active remote-monitoring instruments using discretely tunable infrared gas lasers and heterodyne receivers have been used for measurements of ozone and other trace constituents in the atmosphere. A ground-based solar heterodyne radiometer has been used in discrete spectral regions near 9.5 microns to measure altitude profiles of ozone in both the troposphere and stratosphere. Results indicate that this technique shows promise in providing calibration points for earth-orbiting ozone-measurement instruments. An airborne laser absorption spectrometer has been used to measure tropospheric ozone in two series of flights during the winter and spring of 1977, and these operations are described. Plans are also in progress to fly a balloon-borne heterodyne radiometer during the fall of 1977 in order to measure stratospheric trace species.

Menzies, R. T.↗

Diode laser spectra of CC12F2 near 10.8 microns; air-broadening effects

A tunable diode laser absorption spectrometer with resolution of about 0.0001/cm was used to record air-broadened spectra of CC12F2 in two regions near 922.8/cm and 921.7/cm. In the 922.8/cm region the structure shows good intensity contrast at pressures corresponding to upper atmospheric pressures. The absorption features have a spacing of 0.014/cm, which is sufficiently wide to retain spectral structure at pressures as high as 48 torr or altitudes as low as 19 km. The apparent broadening is 2 MHz/torr. The single-line broadening coefficient for CC12F2 can be estimated to be 8 + or - 2 MHz/torr FWHM. In the 921.7/cm region the high-resolution structure is discernible up to 24 torr, but the intensity contrast is not sufficiently strong to be of use in analysis of stratospheric spectra.

Jennings, D. E.↗

Stratospheric ozone measurement with an infrared heterodyne spectrometer

Measurements of a stratospheric ozone concentration profile are made by detecting infrared absorption lines with a heterodyne spectrometer. The infrared spectrometer is based on a line-by-line tunable CO2 lasers, a liquid-nitrogen cooled HgCdTe photomixer, and a 64-channel spectral line receiver. The infrared radiation from the source is mixed with local-oscillator radiation. The difference frequency signal in a bandwidth above and below the local-oscillator frequency is detected. The intensity in each sideband is found by subtracting sideband contributions. It is found that absolute total column density is 0.32 plus or minus 0.02 cm-atm with a peak mixing ratio at about 24 km. The (7,1,6)-(7,1,7) O3 line center frequency is identified as 1043.1772/cm. Future work will involve a number of ozone absorption lines and measurements of diurnal variation. Completely resolved stratospheric lines may be inverted to yield concentration profiles of trace constituents and stratospheric gases.

Abbas, M. M.↗

Saturated absorption in NH3 demonstrated using a tuneable diode laser

Saturation of molecular transitions using a tunable diode laser has been demonstrated for the first time using a standing-wave-cavity configuration with the laser beam focused at the sample. Observed saturation effects in NH3 transitions near 888 kaysers include sub-Doppler (Lamb-dip) resonances at the line center.

Jennings, D. E.↗

Lens window simplifies TDL housing

Lens window seal in tunable-diode-laser housing replaces plan parallel window. Lens seals housing and acts as optical-output coupler, thus eliminating need for additional reimaging or collimating optics.

Robinson, D. M.↗