Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “testing statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Convergent Concordant Mode Approach for Molecular Vibrations: CMA-2

The concordant mode approach (CMA) is a promising new scheme for dramatically increasing the system size and level of theory achievable in quantum chemical computations of molecular vibrational frequencies. Here, we achieve advances in the CMA hierarchy by computations targeting CCSD(T)/cc-pVTZ (coupled cluster singles and doubles with perturbative triples using a correlation-consistent polarized-valence triple-ζ basis set) benchmarks within the G2 molecular test set, executing a statistical analysis for 1501 frequencies from 111 compounds and then separately solving the refractory case of pyridine. First, MP2/cc-pVTZ (second-order Møller–Plesset perturbation theory with the same basis set) proves to be an excellent and preferred choice for generating the underlying (Level B) normal modes of the CMA scheme. Utilizing this Level B within the CMA-0A method reproduces the 1501 benchmark frequencies with a mean absolute error (MAE) of only 0.11 cm –1 and an attendant standard deviation of 0.49 cm –1 . Second, a convergent CMA-2 method is constituted that allows efficient computation of higher level (Level A) frequencies to any reasonable accuracy threshold by using only Hartree–Fock (HF) and MP2 or density functional theory (DFT) data to generate ξ parameters, which select the sparse off-diagonal force field elements for explicit evaluation at Level A. When Level B = MP2/cc-pVTZ, a cutoff of ξ = 0.02 provides an average maximum absolute error per molecule of only 0.17 cm –1 by incurring merely a 33% increase in average cost over CMA-0A. This CMA-2 method also eradicates the 4 problematic CMA-0A outliers of pyridine with even less effort (ξ = 0.04, 22% increase). Finally, the newly developed CMA procedures are shown to be highly successful when applied to 1-(1H-pyrrol-3-yl)ethanol, a new test molecule with diverse types of vibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Feasibility of Correlation-Aware Inference and Universal Precision Scaling in Bonse–Hart Ultra-Small-Angle Neutron Scattering

Bonse–Hart ultra-small-angle neutron scattering (USANS) provides access to micrometre-scale structure, but useful measurements often require long counting times. In this work, we test whether the expected smoothness of the scattering profile can be exploited to improve data quality at lower counting statistics. We apply a Gaussian-process-based method to Bonse–Hart USANS data and evaluate its performance on pseudo-measurements generated from high-statistics experiments under Poisson statistics. This provides a stringent test of how well the underlying I(Q) profile can be reconstructed when the available counts are substantially reduced. We further show that, in the counting-limited regime, the reconstruction error follows a universal scaling behaviour that differs from the usual independent-counting expectation. At higher counts, the improvement crosses over to a resolution-limited regime set by analyser-angle discretization and rocking-curve width. These results clarify when correlation-aware inference is useful in USANS and provide a practical basis for improving measurement efficiency and beam-time usage.

Tung, Chi-Huan [ORNL] (ORCID:0000000221972074)↗

Does Size Really Matter? Analysis of the Effect of Large Fibroids and Uterine Volumes on Complication Rates of Uterine Artery Embolisation

The purpose of this study was to determine whether there is a correlation between large uterine fibroid diameter, uterine volume, number of vials of embolic agent used and risk of complications from uterine artery embolisation (UAE). This was a prospective study involving 121 patients undergoing UAE embolisation for symptomatic uterine fibroids at a single institution. Patients were grouped according to diameter of largest fibroid and uterine volume. Results were also stratified according to the number of vials of embolic agent used and rate of complications. No statistical difference in complication rate was demonstrated between the two groups according to diameter of the largest fibroid (large fibroids were classified as {>=}10 cm; Fisher's exact test P = 1.00), and no statistical difference in complication rate was demonstrated according to uterine volume (large uterine volume was defined as {>=}750 cm{sup 3}; Fisher's exact test P = 0.70). 84 of the 121 patients had documentation of the number of vials used during the procedure. Patients were divided into two groups, with {>=}4 used defined as a large number of embolic agent. There was no statistical difference between these two groups and no associated increased risk of developing complications. This study showed no increased incidence of complications in women with large-diameter fibroids or uterine volumes as defined. In addition, there was no evidence of increased complications according to quantity of embolic material used. Therefore, UAE should be offered to women with large fibroids and uterine volumes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Data Collection for Determining Statistical Distributions of Module Power Undergoing Potential-Induced Degradation: Preprint

We propose a method for increasing the frequency of data collection and reducing the time and cost of accelerated lifetime testing of photovoltaic modules undergoing potential-induced degradation (PID). This consists of in-situ measurements of dark current-voltage curves of the modules at elevated stress temperature, their use to determine the maximum power at 25 degrees C standard test conditions (STC), and distribution statistics for determining degradation rates as a function of stress level. The semi-continuous data obtained by this method clearly show degradation curves of the maximum power, including an incubation phase, rates and extent of degradation, precise time to failure, and partial recovery. Stress tests were performed on crystalline silicon modules at 85% relative humidity and 60 degrees C, 72 degrees C, and 85 degrees C. Activation energy for the mean time to failure (1% relative) of 0.85 eV was determined and a mean time to failure of 8,000 h at 25 degrees C and 85% relative humidity is predicted. No clear trend in maximum degradation as a function of stress temperature was observed.

14 SOLAR ENERGY↗

Variability of Gross Tumor Volume Delineation in Head-and-Neck Cancer Using PET/CT Fusion, Part II: The Impact of a Contouring Protocol

The purpose of this study was to assess the efficacy of a gross tumor volume (GTV) contouring protocol on interobserver variability between 4 physicians in positron emission therapy/computed tomography (PET/CT) treatment planning of head-and-neck cancer. A GTV contouring protocol for PET/CT treatment planning was developed utilizing 4 stages: Preliminary contouring on CT alone, determination of appropriate PET windowing, accurate image registration, and modification of CT contouring with correctly formatted PET/CT display and rules for modality disagreement. Two neuroradiologists and 2 radiation oncologists (designated as A, B, C, and D, respectively) were given a tutorial of PET/CT coregistered imaging individualized to their skill level, which included a step-by-step explanation of the protocol with clinical examples. Opportunities for questions and hands-on practice were given. The physicians were asked to re-contour 16 head-and-neck patients from Part I on PET/CT fusion imaging. Differences in volume magnitude were analyzed for statistical significance by analysis of variance (ANOVA) and paired t-tests ({alpha} < 0.05). Volume overlap was analyzed for statistical significance using Wilcoxon signed-rank tests ({alpha} < 0.05). Volume overlap increased significantly from Part I to Part II (p < 0.05). One previously significant difference between physicians disappeared with the protocol in place. The mean fusion volume of Physician C, however, remained significantly larger than that of Physician D (p < 0.01). This result is unchanged from Part I. The multidisciplinary contouring protocol significantly improved the coincidence of GTVs contoured by multiple physicians. The magnitudes of the volumes showed marginal improvement in consistency. Developing an institutional contouring protocol for PET/CT treatment planning is highly recommended to reduce interobserver variability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Target Detection via Cognitive Radars Using Change-Point Detection, Learning, and Adaptation

Many radar detection algorithms that assume a stationary environment (clutter) have been proposed and analyzed over the years. However, in practice, changes in the nonstationary environment can perturb the parameters of the clutter distribution, or even alter the clutter distribution family, which can greatly deteriorate the target detection capability. To avoid such potential performance degradation, cognitive radar systems are envisioned which are required to rapidly realize the nonstationarity, accurately learn the new characteristics of the environments, and adaptively update the detector. In this paper, aiming to develop a fully cognitive radar for target detection in nonstationary environments, we propose a unifying framework that integrates (i) change-point detection of clutter distributions by using a data-driven cumulative sum (CUSUM) algorithm and its extended version, (ii) learning/identification of clutter distribution by applying sparse theory and kernel density estimation methods, and (iii) adaptive target detection by automatically modifying the likelihood-ratio test and corresponding detection threshold. Further, with extensive numerical examples, we demonstrate the achieved improvements in detection performance due to the proposed framework in comparison to a nonadaptive case, an adaptive matched filter (AMF) method, and the clairvoyant case. Herein, we also use Wilcoxon rank-sum tests to evaluate the statistical significance of the performance improvements

42 ENGINEERING↗

Texture analysis of placental MRI: can it aid in the prenatal diagnosis of placenta accreta spectrum?

Purpose: To determine if texture analysis can differentiate placenta accreta spectrum (PAS) from normal placenta on MRI. Methods: We performed retrospective image analysis of 80 patients, comprised of 46 patients with PAS and 34 patients without PAS. Histopathology was used as the reference standard. Sagittal single shot fast spin echo T2-weighted MRI sequences acquired from a single institution were analyzed. Placental heterogeneity was quantified using in-house software on a Matlab platform, including the standard deviation of pixel intensity, coefficient of variation, gray-level co-occurrence matrices (GLCM), histogram-oriented gradients (HOG), and fractal analysis with box sizes from 2 to 512. Two-tailed unpaired Student’s t test was used with statistical significance of p < 0.05. Results: PAS was associated with higher values for standard deviation of pixel intensity and fractal analysis at every box size. Fractal analysis at box sizes 256 (p = 0.011) and 32 (p = 0.021), and standard deviation of pixel intensity (p = 0.023) were the most statistically significant. Fractal values at box size 256 for PAS was 0.13 versus 0.090 for patients without PAS, while standard deviation of pixel intensity was 3.7 for PAS versus 2.5 for patients without PAS. No statistically significant association between PAS and GLCM, coefficient of variation, and HOG was found. Conclusion: Statistically significant differences were found between normal and abnormal groups using standard deviation of pixel intensity and fractal analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Embolization of the Gastroduodenal Artery Before Selective Internal Radiotherapy: A Prospectively Randomized Trial Comparing Platinum-Fibered Microcoils with the Amplatzer Vascular Plug II

The Amplatzer Vascular Plug II (AVP II) is a novel device for transcatheter vessel occlusion, for which only limited comparative data exist. Embolotherapy of the gastroduodenal artery (GDA) is essential before internal radiotherapy (SIRT) in order to prevent radiation-induced peptic ulcerations due to migration of yttrium-90 microspheres. The purpose of this study was to compare the vascular anatomical limitations, procedure time, effectiveness, and safety of embolization of the GDA with coils versus the AVP II. Fifty patients stratified for SIRT were prospectively randomized for embolization of the GDA with either coils or the AVP II. The angle between the aorta and the celiac trunk, diameter of the GDA, fluoroscopy time and total time for embolization, number of embolization devices, complications, and durability of vessel occlusion at follow-up angiography for SIRT were recorded. A t-test was used for statistical analysis. Embolizations with either coils or the AVP II were technically feasible in all but two patients scheduled for embolization of the GDA with the AVP II. In both cases the plug could not be positioned due to the small celiac trunk outlet angles of 17{sup o} and 21{sup o}. The mean diameter of the GDA was 3.7 mm (range, 2.2-4.8 mm) for both groups. The procedures differed significantly in fluoroscopy time (7.8 min for coils vs. 2.6 min for the AVP II; P < 0.001) and embolization time (23.1 min for coils vs. 8.8 min for the AVP II; P < 0.001). A mean of 6.0 {+-} 3.2 coils were used for GDA embolization, while no more than one AVP II was needed for successful vessel occlusion (P < 0.001). One coil migration occurred during coil embolization, whereas no procedural complication was encountered with the use of the AVP II. Vessel reperfusion was noted in only one patient, in whom coil embolization was performed. In conclusion, embolization of the GDA with the AVP II is safe, easy, rapid, and highly effective; only an extremely sharp-angled celiac trunk outlet represented an anatomical limitation for device deployment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Pneumothorax Complicating Coaxial and Non-coaxial CT-Guided Lung Biopsy: Comparative Analysis of Determining Risk Factors and Management of Pneumothorax in a Retrospective Review of 650 Patients

PurposeTo assess the scope and determining risk factors related to the development of pneumothorax throughout CT-guided biopsy of pulmonary lesions in coaxial and non-coaxial techniques and the outcome of its management.Materials and MethodsThe study included CT-guided percutaneous lung biopsies in 650 consecutive patients (407 males, 243 females; mean age 54.6 years, SD 5.2) from November 2008 to June 2013 in a retrospective design. Patients were classified according to lung biopsy technique into coaxial group (318 lesions) and non-coaxial group (332 lesions). Exclusion criteria for biopsy were lesions <5 mm in diameter, uncorrectable coagulopathy, positive-pressure ventilation, severe respiratory compromise, pulmonary arterial hypertension, or refusal of the procedure. Risk factors related to the occurrence of pneumothorax were classified into: (a) Technical risk factors, (b) patient-related risk factors, and (c) lesion-associated risk factors. Radiological assessments were performed by two radiologists in consensus. Mann–Whitney U test and Fisher’s exact tests were used for statistical analysis. p values <0.05 were considered statistically significant.ResultsThe incidence of pneumothorax complicating CT-guided lung biopsy was less in the non-coaxial group (23.2 %, 77 out of 332) than the coaxial group (27 %, 86 out of 318). However, the difference in incidence between both groups was statistically insignificant (p = 0.14). Significant risk factors for the development of pneumothorax in both groups were emphysema (p < 0.001 in both groups), traversing a fissure with the biopsy needle (p value 0.005 in non-coaxial group and 0.001 in coaxial group), small lesion, less than 2 cm in diameter (p value of 0.02 in both groups), location of the lesion in the basal or mid sections of the lung (p = 0.003 and <0.001 in non-coaxial and coaxial groups, respectively), and increased needle track path within the lung tissue of more than 2.5 cm (p = 0.01 in both groups). The incidence of pneumothorax in the non-coaxial group was significantly correlated to the number of specimens obtained (p = 0.006). This factor was statistically insignificant in the coaxial group (p = 0.45). The biopsy yield was more diagnostic and conclusive in the coaxial group in comparison to the non-coaxial group (p = 0.008). Simultaneous incidence of pneumothorax and pulmonary hemorrhage was 27.3 % (21/77) in non-coaxial group and in 30.2 % (26/86) in coaxial group. Conservative management was sufficient for treatment of 91 out of 101 patients of pneumothorax in both groups (90.1 %). Manual evacuation of pneumothorax was efficient in 44/51 patients (86.3 %) in both groups and intercostal chest tube was applied after failure of manual evacuation (7 patients: 13.7 %), from which one patient developed a persistent air leakage necessitating pleurodesis.ConclusionPneumothorax complicating CT-guided core biopsy of pulmonary lesions, showed the insignificant difference between coaxial and non-coaxial techniques. However, both techniques have the same significant risk factors including small and basal lesions, increased lesion’s depth from pleural surface, and increased length of aerated lung parenchyma crossed by biopsy needle and passing through pulmonary fissures in the needle tract.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Amplatzer Vascular Plugs Versus Coils for Embolization of Pulmonary Arteriovenous Malformations in Patients with Hereditary Hemorrhagic Telangiectasia

PurposeCoil embolization of pulmonary arteriovenous malformations (PAVMs) has a high re-canalization/re-perfusion rate. Embolization with Amplatzer plugs has been previously described, but the long-term efficacy is not established. This study reports the experience of a referral medical center with the use of coils and Amplatzer plugs for treating PAVMs in patients with hereditary hemorrhagic telangiectasia.MethodsThe study was approved by the Institutional Review Board with waiver of informed consent. The cohort included all patients who underwent PAVM embolization in 2004–2014 for whom follow-up imaging scans were available. The medical files were retrospectively reviewed for background data, embolization method (coils, Amplatzer plugs, both), and complications. Re-canalization of treated PAVMs was assessed from intrapulmonary angiograms (following percutaneous procedures) or computed tomography angiograms. Fisher’s exact test and Pearson Chi-squared test or t test were used for statistical analysis, with significance at p < 0.05.Results16 patients met the study criteria. Imaging scans were available for 63 of the total 110 PAVMs treated in 41 procedures. Coils were used for embolization in 37 PAVMs, Amplatzer plugs in 21, and both in five. Median follow-up time was 7.7 years (range 1.4–18.9). Re-canalization was detected in seven vessels, all treated with coils; there were no cases of re-canalization in plug-occluded vessels (p = 0.0413).ConclusionThe use of Amplatzer plugs for the embolization of PAVMs in patients with hemorrhagic telangiectasia is associated with a significantly lower rate of re-canalization of feeding vessels than coils. Long-term prospective studies are required to confirm these findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of a Curved Electrode with Controllable Direction in the Radiofrequency Ablation of Liver Tumors Behind Large Vessels

Purpose: To investigate the role of a novel curved radiofrequency ablation (RFA) electrode with controllable direction in the ablation of tumors behind large hepatic vessels in ex vivo bovine and in vivo canine liver experiments. Materials and Methods: Approval from the institutional animal care and use committee was obtained. In ex vivo experiments, conventional multi-tines expandable electrodes, conventional monopolar straight electrodes and novel curved electrodes were used in the ablation of the bovine liver (n = 90). The ablated area, parallel axis, vertical axis and shape of different electrodes were compared. Then, 24 beagle dogs (10 months old, female) were used for in vivo experiments. Visual tumor targets deeply located in the portal vein were established, and ultrasound-guided liver ablation was performed with different electrodes. The ablation range, target coverage rate, percentage of normal tissue injury and damage to adjacent vessels were evaluated. The Kruskal–Wallis test and the Chi-squared test were used for statistical analysis. Results: For the ex vivo study with a 3-cm electrode, the ablation area of the multi-tines expandable electrode group (7.14 ± 0.16 cm{sup 2}) was significantly larger than that of the novel curved electrode group (5.01 ± 0.30 cm{sup 2}, P < 0.001) and the monopolar straight electrode group (5.43 ± 0.15 cm{sup 2}, P < 0.001). The results obtained with the 4-cm electrode in the three groups were in accordance with those of the 3-cm electrode. In vivo, the normal tissue damage area of the novel curved electrode group was smaller than that of the multi-tines expandable electrode group (1.10 ± 0.18 cm{sup 2} vs. 4.00 ± 0.18 cm{sup 2}, P < 0.001). The target coverage rate of the novel curved electrode group was better than that of the monopolar straight electrode group (100% vs. 80.86 ± 1.68%, P < 0.001). The hematoxylin and eosin (H&E) and TUNEL staining results showed that the ablation necrosis area was adjacent to large vessels, but the vascular wall was not significantly damaged in the novel curved electrode group. Conclusion: Our preliminary results showed that the novel curved RFA electrode with controllable direction could achieve accurate ablation for tumors behind large hepatic vessels, with a better target coverage rate and less damage to normal tissue, than conventional multi-tines expandable electrodes and monopolar straight electrodes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of NMME temperature and precipitation bias and forecast skill for South Asia

Systematic error and forecast skill for temperature and precipitation in two regions of Southern Asia are investigated using hindcasts initialized May 1 from the North American Multi-Model Ensemble. We focus on two contiguous but geographically and dynamically diverse regions: the Extended Indian Monsoon Rainfall (70–100E, 10–30 N) and the nearby mountainous area of Pakistan and Afghanistan (60–75E, 23–39 N). Forecast skill is assessed using the Sign test framework, a rigorous statistical method that can be applied to non-Gaussian variables such as precipitation and to different ensemble sizes without introducing bias. We find that models show significant systematic error in both precipitation and temperature for both regions. The multi-model ensemble mean (MMEM) consistently yields the lowest systematic error and the highest forecast skill for both regions and variables. However, we also find that the MMEM consistently provides a statistically significant increase in skill over climatology only in the first month of the forecast. While the MMEM tends to provide higher overall skill than climatology later in the forecast, the differences are not significant at the 95% level. We also find that MMEMs constructed with a relatively small number of ensemble members per model can equal or outperform MMEMs constructed with more members in skill. This suggests some ensemble members either provide no contribution to overall skill or even detract from it.

54 ENVIRONMENTAL SCIENCES↗

Z-Pinning approach for 3D printing mechanically isotropic materials

Conventional 3D printing approaches are restricted to building up material in a layer-by-layer format, which is more appropriately considered “2.5-D” printing. The layered structure inherently results in significant mechanical anisotropy in printed parts, causing the tensile strength in the build direction (z-axis) to be only a fraction of the in-plane strength – a decrease of 50–75% is common. In this study, a novel “z-pinning” approach is described that allows continuous material to be deposited across multiple layers within the volume of the part. Here, the z-pinning process is demonstrated using a Fused Filament Fabrication (FFF) printer for polylactic acid (PLA) and carbon fiber reinforced PLA. For both materials, z-pinning increased the tensile strength and toughness in the z-direction by more than a factor of 3.5. Direct comparisons to tensile strength in the x-axis showed a significant decrease in mechanical anisotropy as the volume of the pin was increased relative to the void in the rectilinear grid structure. In fact, the PLA sample with the largest pin volume demonstrated mechanically isotropic properties within the statistical uncertainty of the tests. Tensile test results were also analyzed relative to the functional area resisting deformation for each sample.

36 MATERIALS SCIENCE↗

Experimental investigation of probabilistic failure of SiC/SiC composite tubes under multiaxial loading

This paper presents an experimental investigation of the failure behavior of SiC fiber-reinforced SiC matrix (SiC/SiC) composite tubes under multiaxial loading. A new testing apparatus is designed to independently apply axial stress and internal pressure to SiC/SiC tubes. Acoustic emission (AE) is used to monitor the damage growth in the specimen. Based on the measured stress–strain response, a strain-based criterion is proposed to determine the proportional limit stress (PLS). The proposed strain-based criterion is compared with the PLS determined by the AE measurement. The PLS is determined for different loading ratios to form a multiaxial failure surface. By testing multiple replicates, the statistical variations of the PLS are determined. In conclusion, based on the experimental results, a mathematical model is developed to characterize the probability distribution of the PLS of SiC/SiC composites under multiaxial loading.

36 MATERIALS SCIENCE↗

Roles of Radiation Dose and Chemotherapy in the Etiology of Stomach Cancer as a Second Malignancy

Purpose: To evaluate the roles of radiation dose, chemotherapy, and other factors in the etiology of stomach cancer in long-term survivors of testicular cancer or Hodgkin lymphoma. Methods and Materials: We conducted a cohort study in 5,142 survivors of testicular cancer or Hodgkin lymphoma treated in the Netherlands between 1965 and 1995. In a nested case-control study, detailed information on treatment, smoking, gastrointestinal diseases, and family history was collected for 42 patients with stomach cancer and 126 matched controls. For each subject, the mean radiation dose to the stomach was estimated. Relative risks (RRs) of stomach cancer and the radiation-related excess relative risk (ERR) per gray were calculated by conditional logistic regression analysis. Results: The risk of stomach cancer was 3.4-fold increased compared with the general population. The risk increased with increasing mean stomach dose (p for trend, <0.001), at an ERR of 0.84 per Gy (95% confidence interval [CI], 0.12-15.6). Mean stomach doses of more than 20 Gy were associated with a RR of 9.9 (95% CI, 3.2-31.2) compared with doses below 11 Gy. The risk was 1.8-fold (95% CI, 0.8-4.4) increased after chemotherapy and 5.4-fold (95% CI, 1.2-23.9) increased after high doses of procarbazine (>=13,000 mg) vs. <10,000 mg. The RR of smoking more than 10 cigarettes per day vs. no smoking was 1.6 (95% CI, 0.6-4.2). Conclusions: Stomach cancer risk is strongly radiation dose dependent. The role of chemotherapy, particularly of procarbazine and related agents, needs further study, because of the relatively small numbers of chemotherapy-treated subjects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is Adjuvant Chemoradiotherapy Overtreatment in Cervical Cancer Patients With Intermediate Risk Factors?

Purpose: To determine whether adjuvant chemoradiotherapy (CRT) improves the outcome of cervical cancer patients with intermediate risk factors. Methods and Materials: Between January 2000 and June 2006, the medical records of 735 patients who had undergone radical surgery for Stage IB-IIA cervical cancer were reviewed retrospectively. Of the 735 patients, 172 with two or more intermediate risk factors (i.e., lymphovascular space involvement, deep stromal invasion, and tumor size {>=}2 cm) were grouped as follows according to the adjuvant treatment received: 34 patients, no further treatment; 49 patients, RT; and 89 patients, CRT. The significance of the clinical parameters and recurrence-free survival of each group were analyzed. Results: Of the 172 patients with any of the intermediate risk factors, 137 (79.6%) had two or more intermediate risk factors. Of the 172 patients, 12 developed recurrences (6.4%)->(7.0%), with 6 in the pelvis and 6 in distant sites. All 12 recurrences occurred in those who had two or more intermediate risk factors (sensitivity, 100%); however, only six recurrences were detected in patients who met the Gynecologic Oncology Group criteria for the intermediate-risk group (sensitivity, 50%; Z test, p < .05). A statistically significant difference was found in the 3-year recurrence-free survival rate among the no further treatment, RT, and CRT groups (67.5%, 90.5%, and 97.5%, respectively; p < .05). The incidence of Grade 3-4 hematologic and gastrointestinal toxicities was not significantly different statistically between the RT and CRT groups (6.1% and 13.4%, respectively; p > .05). Conclusion: Postoperative adjuvant CRT can improve the outcome of cervical cancer patients with intermediate risk factors, with low increase in toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of EORTC Prognostic Factors for Adults With Low-Grade Glioma: A Report Using Intergroup 86-72-51

Purpose: A prognostic index for survival was constructed and validated from patient data from two European Organisation for Research and Treatment of Cancer (EORTC) radiation trials for low-grade glioma (LGG). We sought to independently validate this prognostic index with a separate prospectively collected data set (Intergroup 86-72-51). Methods and Materials: Two hundred three patients were treated in a North Central Cancer Treatment Group-led trial that randomized patients with supratentorial LGG to 50.4 or 64.8 Gy. Risk factors from the EORTC prognostic index were analyzed for prognostic value: histology, tumor size, neurologic deficit, age, and tumor crossing the midline. The high-risk group was defined as patients with more than two risk factors. In addition, the Mini Mental Status Examination (MMSE) score, extent of surgical resection, and 1p19q status were also analyzed for prognostic value. Results: On univariate analysis, the following were statistically significant (p < 0.05) detrimental factors for both progression-free survival (PFS) and overall survival (OS): astrocytoma histology, tumor size, and less than total resection. A Mini Mental Status Examination score of more than 26 was a favorable prognostic factor. Multivariate analysis showed that tumor size and MMSE score were significant predictors of OS whereas tumor size, astrocytoma histology, and MMSE score were significant predictors of PFS. Analyzing by the EORTC risk groups, we found that the low-risk group had significantly better median OS (10.8 years vs. 3.9 years, p < 0.0001) and PFS (6.2 years vs. 1.9 years, p < 0.0001) than the high-risk group. The 1p19q status was available in 66 patients. Co-deletion of 1p19q was a favorable prognostic factor for OS vs. one or no deletion (median OS, 12.6 years vs. 7.2 years; p = 0.03). Conclusions: Although the low-risk group as defined by EORTC criteria had a superior PFS and OS to the high-risk group, this is primarily because of the influence of histology and tumor size. Co-deletion of 1p19q is a prognostic factor. Future studies are needed to develop a more refined prognostic system that combines clinical prognostic features with more robust molecular and genetic data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Validation of a Prognostic Model Using Blood Biomarker Information for Prediction of Survival of Non-Small-Cell Lung Cancer Patients Treated With Combined Chemotherapy and Radiation or Radiotherapy Alone (NCT00181519, NCT00573040, and NCT00572325)

Purpose: Currently, prediction of survival for non-small-cell lung cancer patients treated with (chemo)radiotherapy is mainly based on clinical factors. The hypothesis of this prospective study was that blood biomarkers related to hypoxia, inflammation, and tumor load would have an added prognostic value for predicting survival. Methods and Materials: Clinical data and blood samples were collected prospectively (NCT00181519, NCT00573040, and NCT00572325) from 106 inoperable non-small-cell lung cancer patients (Stages I-IIIB), treated with curative intent with radiotherapy alone or combined with chemotherapy. Blood biomarkers, including lactate dehydrogenase, C-reactive protein, osteopontin, carbonic anhydrase IX, interleukin (IL) 6, IL-8, carcinoembryonic antigen (CEA), and cytokeratin fragment 21-1, were measured. A multivariate model, built on a large patient population (N = 322) and externally validated, was used as a baseline model. An extended model was created by selecting additional biomarkers. The model's performance was expressed as the area under the curve (AUC) of the receiver operating characteristic and assessed by use of leave-one-out cross validation as well as a validation cohort (n = 52). Results: The baseline model consisted of gender, World Health Organization performance status, forced expiratory volume, number of positive lymph node stations, and gross tumor volume and yielded an AUC of 0.72. The extended model included two additional blood biomarkers (CEA and IL-6) and resulted in a leave-one-out AUC of 0.81. The performance of the extended model was significantly better than the clinical model (p = 0.004). The AUC on the validation cohort was 0.66 and 0.76, respectively. Conclusions: The performance of the prognostic model for survival improved markedly by adding two blood biomarkers: CEA and IL-6.

62 RADIOLOGY AND NUCLEAR MEDICINE↗