Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Detection of Head and Neck Cancer Based on Longitudinal Changes in Serum Protein Abundance

Head and Neck Squamous Cell Carcinoma (HNSCC) is significantly represented in the military population with substantial impact on military operations. Two-thirds of new HNSCC cases are first diagnosed at advanced stage III or IV with lymph node metastases. Thus, there is an urgent need of biomarkers for early detection and risk stratification. Archived serum samples from the Department of Defense Serum Repository provide a unique resource for longitudinal studies of HNSCC in the military and the identification of early detection biomarkers. Methods: We identified 175 patients diagnosed with HNSCC with 175 matched healthy controls and retrieved a total of 978 serum samples drawn at the time of diagnosis, 2 and 4 years prior to diagnosis, and 2 years after diagnosis. Following immunoaffinity depletion, serum samples were analyzed by targeted proteomics assays for multiplexed quantification of a panel of 146 candidate protein biomarkers from the curated literature. Results: We derived a 13-protein signature that distinguishes case versus controls based on longitudinal changes in serum protein concentration. The abundances of each of the 13 proteins remain constant over time in control subjects. The area under the curve for the derived random forest classifier was 0.90. Conclusions: This 13-protein classifier is highly promising for detection of HNSCC prior to overt symptoms. Impact: Use of longitudinal samples has significant potential to identify biomarkers for detection and risk stratification.

59 BASIC BIOLOGICAL SCIENCES↗

Detection of a multi–disease biomarker in saliva with graphene field effect transistors

Human carbonic anhydrase 1 (CA1) has been suggested as a biomarker for identification of several diseases including cancers, pancreatitis, diabetes, and Sjogren’s syndrome. However, the lack of a rapid, cheap, accurate, and easy-to-use quantification technique has prevented widespread utilization of CA1 for practical clinical applications. To this end, we present a label-free electronic biosensor for detection of CA1 utilizing highly sensitive graphene field effect transistors (G-FETs) as a transducer and specific RNA aptamers as a probe. The binding of CA1 with aptamers resulted in a positive shift in Dirac voltage V D of the G-FETs, the magnitude of which depended on target concentration. These aptameric G-FET biosensors showed the binding affinity (K D ) of ~2.3 ng/ml (70 pM), which is four orders lower than that reported using a gel shift assay. This lower value of K D enabled us to achieve a detection range (10 pg/ml - 100 ng/ml) which is well in line with the clinically relevant range. These highly sensitive devices allowed us to further prove their clinical relevance by successfully detecting the presence of CA1 in human saliva samples. In conclusion, the utilization of this label-free biosensor could facilitate the early stage identification of various diseases associated with changes in concentration of CAs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WHISPER: Wireless Home Identification and Sensing Platform for Energy Reduction

Many regions of the world benefit from heating, ventilating, and air-conditioning (HVAC) systems to provide productive, comfortable, and healthy indoor environments, which are enabled by automatic building controls. Due to climate change, population growth, and industrialization, HVAC use is globally on the rise. Unfortunately, these systems often operate in a continuous fashion without regard to actual human presence, leading to unnecessary energy consumption. As a result, the heating, ventilation, and cooling of unoccupied building spaces makes a substantial contribution to the harmful environmental impacts associated with carbon-based electric power generation, which is important to remedy. For our modern electric power system, transitioning to low-carbon renewable energy is facilitated by integration with distributed energy resources. Automatic engagement between the grid and consumers will be necessary to enable a clean yet stable electric grid, when integrating these variable and uncertain renewable energy sources. We present the WHISPER (Wireless Home Identification and Sensing Platform for Energy Reduction) system to address the energy and power demand triggered by human presence in homes. The presented system includes a maintenance-free and privacy-preserving human occupancy detection system wherein a local wireless network of battery-free environmental, acoustic energy, and image sensors are deployed to monitor homes, record empirical data for a range of monitored modalities, and transmit it to a base station. Several machine learning algorithms are implemented at the base station to infer human presence based on the received data, harnessing a hierarchical sensor fusion algorithm. Results from the prototype system demonstrate an accuracy in human presence detection in excess of 95%; ongoing commercialization efforts suggest approximately 99% accuracy. Using machine learning, WHISPER enables various applications based on its binary occupancy prediction, allowing situation-specific controls targeted at both personalized smart home and electric grid modernization opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combining MicroED and native mass spectrometry for structural discovery of enzyme–small molecule complexes

With the goal of accelerating the discovery of small molecule–protein complexes, we leverage fast, low-dose, event-based electron counting microcrystal electron diffraction (MicroED) data collection and native mass spectrometry. This approach, which we term electron diffraction with native mass spectrometry (ED-MS), allows assignment of protein target structures bound to ligands with data obtained from crystal slurries soaked with mixtures of known inhibitors and crude biosynthetic reactions. This extends to libraries of printed ligands dispensed directly onto TEM grids for later soaking with microcrystal slurries, and complexes with noncovalent ligands. ED-MS resolves structures of the natural product, epoxide-based cysteine protease inhibitor E-64, and its biosynthetic analogs bound to the model cysteine protease, papain. It further identifies papain binding to its preferred natural products, by showing that two analogs of E-64 outcompete others in binding to papain crystals, and by detecting papain bound to E-64 and an analog from crude biosynthetic reactions, without purification. ED-MS also resolves binding of the CTX-M-14 β-lactamase, a target of active drug development, to the non-β-lactam inhibitor, avibactam, alone or in a cocktail of unrelated compounds. These results illustrate the utility of ED-MS for natural product ligand discovery and for structure-based screening of small molecule binders to macromolecular targets, promising utility for drug discovery.

MicroED↗

DEEPEN 3D PFA Index Models for Exploration Datasets at Newberry Volcano

DEEPEN stands for DE-risking Exploration of geothermal Plays in magmatic ENvironments. As part of the development of the DEEPEN 3D play fairway analysis (PFA) methodology for magmatic plays (conventional hydrothermal, superhot EGS, and supercritical), index models needed to be developed to map values in geoscientific exploration datasets to favorability index values. This GDR submission includes those index models. Index models were created by binning values in exploration datasets into chunks based on their favorability, and then applying a number between 0 and 5 to each chunk, where 0 represents very unfavorable data values and 5 represents very favorable data values. To account for differences in how exploration methods are used to detect each play component, separate index models are produced for each exploration method for each component of each play type. Index models were created using histograms of the distributions of each exploration dataset in combination with literature and input from experts about what combinations of geophysical, geological, and geochemical signatures are considered favorable at Newberry. This is in attempt to create similar sized bins based on the current understanding of how different anomalies map to favorable areas for the different types of geothermal plays (i.e., conventional hydrothermal, superhot EGS, and supercritical). For example, an area of partial melt would likely appear as an area of low density, high conductivity, low vp, and high vp/vs. This means that these target anomalies would be given high (4 or 5) index values for the purpose of imaging the heat source. To account for differences in how exploration methods are used to detect each play component, separate index models are produced for each exploration method for each component of each play type. Index models were produced for the following datasets: - Geologic model - Alteration model - vp/vs - vp - vs - Temperature model - Seismicity (density*magnitude) - Density - Resistivity - Fault distance - Earthquake cutoff depth model

15 GEOTHERMAL ENERGY↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Detecting optical transients using artificial neural networks and reference images from different surveys

ABSTRACT We present a technique to detect optical transients based on an artificial neural networks method. We describe the architecture of two networks capable of comparing images of the same part of the sky taken by different telescopes. One image corresponds to the epoch in which a potential transient could exist; the other is a reference image of an earlier epoch. We use data obtained by the Dr. Cristina V. Torres Memorial Astronomical Observatory and archival reference images from the Sloan Digital Sky Survey. We trained a convolutional neural network and a dense layer network on simulated source samples and then tested the trained networks on samples created from real image data. Autonomous detection methods replace the standard process of detecting transients, which is normally achieved by source extraction of a difference image followed by human inspection of the detected candidates. Replacing the human inspection component with an entirely autonomous method would allow for a rapid and automatic follow-up of interesting targets of opportunity. The toy-model pipeline that we present here is not yet able to replace human inspection, but it might provide useful hints to identify potential candidates. The method will be further expanded and tested on telescopes participating in the Transient Optical Robotic Observatory of the South Collaboration.

79 ASTRONOMY AND ASTROPHYSICS↗

Prompt-fission-neutron spectra in the 239 Pu( n,f ) reaction

Prompt-fission-neutron spectra from Pu 239 ( n , f ) were measured with respect to Cf 252 spontaneous fission for incident neutron energies from 0.7 to 700 MeV at the Weapons Neutron Research facility (WNR) of the Los Alamos Neutron Science Center. A newly designed high-efficiency fission chamber was coupled to the highly segmented Chi-Nu neutron liquid scintillator array to detect neutrons emitted in fission events. The double time-of-flight technique was used to deduce the incident neutron energies from the spallation target and the outgoing-neutron energies from the fission chamber. Prompt-fission-neutron spectra (PFNS) were measured with respect to Cf 252 spontaneous fission down to 200 keV and up to about 12 MeV for all the incident neutron energies with typical total uncertainties well below 2 % up to about 7-MeV outgoing-neutron energy. The general trend of PFNS is well reproduced by JEFF3.3 and ENDF evaluations, although a better agreement is found with JEFF3.3. Discrepancies were observed for the low-energy part of the spectra, especially around the opening of the second-, third- and fourth-chance fission. Additionally, neutron average kinetic energies as a function of incident neutron energy are obtained experimentally with reported total uncertainties below 0.5 % . The measured values agree with the most recent data. The trend is fairly well reproduced by the JEFF3.3 evaluation, although it fails to reproduce the experimental values within their uncertainties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved Limits on Millicharged Particles Using the ArgoNeuT Experiment at Fermilab

A search for millicharged particles, a simple extension of the standard model, has been performed with the ArgoNeuT detector exposed to the Neutrinos at the Main Injector beam at Fermilab. The ArgoNeuT liquid argon time projection chamber detector enables a search for millicharged particles through the detection of visible electron recoils. We search for an event signature with two soft hits (MeV-scale energy depositions) aligned with the upstream target. For an exposure of the detector of 1.0×10 20 protons on target, one candidate event has been observed, compatible with the expected background. This search is sensitive to millicharged particles with charges between 10 -3 $e$ and 10 -1 $e$ and with masses in the range from 0.1 to 3 GeV. This measurement provides leading constraints on millicharged particles in this large unexplored parameter space region.

43 PARTICLE ACCELERATORS↗

Multiplexing of frequency-modulation spectroscopy by spread-spectrum codes, demonstrated in continuous-wave LIDAR

Frequency-modulation spectroscopy (FMS) is generally suited to code-division multiplexing, and we demonstrate that capacity in a form of continuous-wave LIDAR, utilizing a sharp CO 2 absorption transition at 1.6 µm in simple ranging setups. The approach retains the advantages of FMS, including coherent detection and good rejection of broad absorption backgrounds. Extensions of this multiplexed approach to the continuous, simultaneous detection of several transitions would come by transmitting an encoded combination of frequency-modulated carriers, each tuned to detect a unique absorption transition. Signal analysis at the receiver involves a simple process of de-multiplexing that, in a general application, reveals targets at various distances and the absorption-related FMS signals in between.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Memory-Related Frontal Brainwaves Predict Transition to Mild Cognitive Impairment in Healthy Older Individuals Five Years Before Diagnosis

Background: Early prognosis of high-risk older adults for amnestic mild cognitive impairment (aMCI), using noninvasive and sensitive neuromarkers, is key for early prevention of Alzheimer’s disease. We have developed individualized measures in electrophysiological brain signals during working memory that distinguish patients with aMCI from age-matched cognitively intact older individuals. Objective: Here we test longitudinally the prognosis of the baseline neuromarkers for aMCI risk. We hypothesized that the older individuals diagnosed with incident aMCI already have aMCI-like brain signatures years before diagnosis. Methods: Electroencephalogram (EEG) and memory performance were recorded during a working memory task at baseline. The individualized baseline neuromarkers, annual cognitive status, and longitudinal changes in memory recall scores up to 10 years were analyzed. Results: Seven of the 19 cognitively normal older adults were diagnosed with incident aMCI for a median 5.2 years later. The seven converters’ frontal brainwaves were statistically identical to those patients with diagnosed aMCI (n = 14) at baseline. Importantly, the converters’ baseline memory-related brainwaves (reduced mean frontal responses to memory targets) were significantly different from those who remained normal. Furthermore, differentiation pattern of left frontal memory-related responses (targets versus nontargets) was associated with an increased risk hazard of aMCI (HR = 1.47, 95% CI 1.03, 2.08). Conclusion: The memory-related neuromarkers detect MCI-like brain signatures about five years before diagnosis. The individualized frontal neuromarkers index increased MCI risk at baseline. These noninvasive neuromarkers during our Bluegrass memory task have great potential to be used repeatedly for individualized prognosis of MCI risk and progression before clinical diagnosis.

59 BASIC BIOLOGICAL SCIENCES↗

Proteomic Tissue-Based Classifier for Early Prediction of Prostate Cancer Progression

Although ~40% of screen-detected prostate cancers (PCa) are indolent, advanced-stage PCa is a lethal disease with 5-year survival rates around 29%. Identification of biomarkers for early detection of aggressive disease is a key challenge. Starting with 52 candidate biomarkers, selected from existing PCa genomics datasets and known PCa driver genes, we used targeted mass spectrometry to quantify proteins that significantly differed in primary tumors from PCa patients treated with radical prostatectomy (RP) across three study outcomes: (i) metastasis ≥1-year post-RP, (ii) biochemical recurrence ≥1-year post-RP, and (iii) no progression after ≥10 years post-RP. Sixteen proteins that differed significantly in an initial set of 105 samples were evaluated in the entire cohort (n = 338). A five-protein classifier which combined FOLH1, KLK3, TGFB1, SPARC, and CAMKK2 with existing clinical and pathological standard of care variables demonstrated significant improvement in predicting distant metastasis, achieving an area under the receiver-operating characteristic curve of 0.92 (0.86, 0.99, p = 0.001) and a negative predictive value of 92% in the training/testing analysis. This classifier has the potential to stratify patients based on risk of aggressive, metastatic PCa that will require early intervention compared to low risk patients who could be managed through active surveillance.

60 APPLIED LIFE SCIENCES↗

Investigation of the isoscalar monopole response in the proton-rich nucleus 14 O

Deuteron inelastic scattering on 14 O was measured in inverse kinematics using an active-target time projection chamber and a magnetic spectrograph. The experimental technique enabled precise measurements of deuteron recoiling particles in coincidence with beam-like fragments detected in the spectrograph focal plane. The double differential cross section was reconstructed for scattering angles of 3–6 degrees and excitation energies up to 26 MeV. The monopole strength distribution was obtained from the data using a multipole decomposition analysis. The results were compared to quasiparticle random-phase approximation (QRPA) and generator coordinate method (GCM) calculations. The QRPA calculation accurately describes experimental data in the energy range of 13 to 26 MeV. GCM calculations assuming a 12 C (g . s .) + p + p cluster configuration were used to determine the 0 + strength in 14 O below 13 MeV. The monopole transition strength of these cluster states provides a good description of the experimental distribution in the 9–11 MeV region, while the 0$^{+}_{2}$ state accounts for only a small fraction of the experimental strength around 6 MeV.

Active target↗

Refined Telluric Absorption Correction for Low-resolution Ground-based Spectroscopy: Resolution and Radial Velocity Effects in the O{sub 2}A-band for Exoplanets and K i Emission Lines

Telluric correction of spectroscopic observations is either performed via standard stars that are observed close in time and airmass along with the science target, or recently growing in importance, by theoretical telluric absorption modeling. Both approaches work fine when the telluric lines are resolved, i.e., at a spectral resolving power larger than about 10,000, and it is sufficient to facilitate the detection of spectral features at lower resolution. However, a meaningful quantitative analysis also requires the reliable recovery of line strengths. Here, we show for the Fraunhofer A-band of molecular O{sub 2} that the standard telluric correction approach fails in this at lower spectral resolutions, as an example for the general problem. Doppler-shift-dependent errors of the restored flux may arise, which can amount to more than 50% in extreme cases, depending on the line shapes of the target spectral features. Two applications are discussed: the recovery of the O{sub 2} band in the reflected light of an Earth analog atmosphere, as facilitated potentially in the future using an orbiting starshade and a ground-based extremely large telescope; and the recovery of the intrinsic ratio of the K i lines in the post-nova V4332 Sgr tracing the optical depth of the emitting region, to exemplify the relevance using present-day instrumentation. We show how one should derive correction functions for the compensation of the error in dependence of radial velocity shift, spectral resolution, and target line-profile function by use of high-resolution atmospheric transmission modeling, which has to be solved for the individual case.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cubical moderators for the Neutron Target Demonstator (NTD)

Neutron capture cross sections of unstable isotopes are important for neutron induced nucleosynthesis as well as for technological applications. The traditional time-of-flight method reaches its limits once the necessary detection of the reaction products is hampered by the size (mass) of the sample. Several factors may limit the sample mass: The decay properties of radioactive isotopes interfere with the signals from the neutron capture or neutron-induced fission reactions; The limited range of charged reaction products requires a thin sample. In both cases, an increased neutron fluence at the sample position with ever improved neutron sources overcomes the lack of reaction rate. Reference proposed a combination of a radioactive beam facility, an ion storage ring and a spallation neutron source surrounded by neutron moderator. This idea is part of the LANSCE strategy to stay a worldwide leader for neutron induced research. Figure 1 shows a sketch of the proposed future setup.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multiwavelength Observations of the Blazar PKS 0735+178 in Spatial and Temporal Coincidence with an Astrophysical Neutrino Candidate IceCube-211208A

We report on multiwavelength target-of-opportunity observations of the blazar PKS 0735+178, located 2.°2 away from the best-fit position of the IceCube neutrino event IceCube-211208A detected on 2021 December 8. The source was in a high-flux state in the optical, ultraviolet, X-ray, and GeV γ -ray bands around the time of the neutrino event, exhibiting daily variability in the soft X-ray flux. The X-ray data from Swift-XRT and NuSTAR characterize the transition between the low-energy and high-energy components of the broadband spectral energy distribution (SED), and the γ -ray data from Fermi-LAT, VERITAS, and H.E.S.S. require a spectral cutoff near 100 GeV. Both the X-ray and γ -ray measurements provide strong constraints on the leptonic and hadronic models. We analytically explore a synchrotron self-Compton model, an external Compton model, and a lepto-hadronic model. Models that are entirely based on internal photon fields face serious difficulties in matching the observed SED. The existence of an external photon field in the source would instead explain the observed γ -ray spectral cutoff in both the leptonic and lepto-hadronic models and allow a proton jet power that marginally agrees with the Eddington limit in the lepto-hadronic model. We show a numerical lepto-hadronic model with external target photons that reproduces the observed SED and is reasonably consistent with the neutrino event despite requiring a high jet power.

79 ASTRONOMY AND ASTROPHYSICS↗

Sharp detection of low-dimensional structure in probability measures via dimensional logarithmic Sobolev inequalities

Identifying low-dimensional structure in high-dimensional probability measures is an essential pre-processing step for efficient sampling. To identify this structure, we approximate the target measure as a perturbation of an arbitrary reference measure along a few directions in $\mathbb{R}^{d}$. These directions are determined by minimizing an upper bound on the Kullback–Leibler (KL) divergence between the target and its approximation. Our contribution improves upon previous works by leveraging dimensional logarithmic Sobolev inequalities to refine the bound on the KL divergence. These inequalities lead to a uniformly tighter bound on the KL divergence, thereby enhancing the identification of the most significant perturbation directions. In particular, when the target and reference are both Gaussian, minimizing the resulting bound is equivalent to minimizing the KL divergence. We further demonstrate the applicability of this analysis to the squared Hellinger distance, where analogous reasoning shows that the dimensional Poincaré inequality offers improved bounds.

Bayesian inference↗

Evaluation of two extraction chromatography resins for scandium and titanium separation for medical isotope production

Scandium-47 ( 47 Sc) can be used in nuclear medicine as a therapeutic-diagnostic, or "theragnostic," radioactive medical isotope for cancer detection and treatment. The 47 Sc isotope can be produced through the photonuclear reaction 48 Ti(γ,p) 47 Sc by irradiating enriched 48 Ti target material. The enriched target material necessary for production is costly; 48 TiO 2 costs ~ $\$$1550/g, and targets can be > 50 g ($\$$77,500) to produce medically relevant amounts of 47 Sc. In order to keep costs low, a highly efficient separation of scandium from bulk titanium is desired, along with efficient methods for recycling the target material. Here this research is focused on evaluating efficient methods for the separation of scandium from bulk quantities of titanium using commercially available diglycolamide-based and hydroxamate-based extraction chromatography resins (DGA resin and ZR resin, respectively). The sorption of 47 Sc and Ti on these resins were investigated at varying concentrations of HNO 3 , HCl, H 2 SO 4 , and HF to explore how they might be used in a large-scale production/processing setting.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗