Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “system calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Total ionospheric electron content calibration using SERIES GPS satellite data

The current status of the Deep Space Network advanced systems research into ionospheric calibration techniques, based on Global Positioning System (GPS) data is described. A GPS-based calibration system is planned to replace the currently used Faraday rotation method by 1989. The SERIES receiver system determines the differential group delay of signals transmitted at two different carrier frequencies. This differential delay includes an ionospheric component and a GPS transmitter offset. The transmitter offsets are different for each GPS satellite. Tests were conducted to assess the effect of the offsets on the ionospheric calibration accuracy. From the obtained data, the total electron content and GPS transmitter offsets are calculated by a least squares estimation method employing a local model of total ionospheric electron content. The end product is an estimation of the total ionospheric content for an arbitrary line-of-sight direction. For the presented polynomial fitting technique, the systematic error due to mismodeling is estimated to be approximately 6 x 10 to the 16th power el/sq m, while the formal error is approximately 2 x 10 to the 16th power el/sq m. The final goal is an error of 3 x 10 to the 16th power el/sq m (approximately 0.7 ns at 2.3 GHz).

Lanyi, G.↗

BATSE imaging survey of the Galactic plane

The burst and transient source experiment (BATSE) onboard the Compton Gamma Ray Observatory (CGRO) provides all sky monitoring capability, occultation analysis and occultation imaging which enables new and fainter sources to be searched for in relatively crowded fields. The occultation imaging technique is used in combination with an automated BATSE image scanner, allowing an analysis of large data sets of occultation images for detections of candidate sources and for the construction of source catalogs and data bases. This automated image scanner system is being tested on archival data in order to optimize the search and detection thresholds. The image search system, its calibration results and preliminary survey results on archival data are reported on. The aim of the survey is to identify a complete sample of black hole candidates in the galaxy and constrain the number of black hole systems and neutron star systems.

Grindlay, J. E.↗

Towards Erecting Straighter Lightweight Towers on the Moon Using Deployable Guy Wires

This paper reports our static stability test findings for a simple guy wire system to correct the natural lateral deflections of an 8.5m tall, compact deployable composite tower intended to support exploration of lunar permanently shadowed regions by nearby robotic assets. Deployable composite booms with microgravity flight heritage are currently being investigated at NASA Langley Research Center (LaRC) and Massachusetts Institute of Technology(MIT)’s Space Resources Workshop for their potential to be vertically deployed in the lunar gravity field, in support of NASA’s Artemis campaign. These applications include vertical solar arrays and the provision of elevated lines-of-sight to science or engineering payloads on landers and rovers, in support of nearby or distant crewed or robotic assets exploring scientifically interesting and hard to reach areas. Useful elevated payloads include radio repeaters, remote sensing and imaging, navigation and power beaming systems. However, while these lightweight booms have an excellent height to mass ratio, they typically exhibit slight axial curvature upon deployment resulting in appreciable lateral dead-load deflection of the tip mass relative to the tower base. This static deflection increases with tower height and tip mass, not only constraining the value delivered by the tower but also endangering its integrity. To develop a competitive, lightweight deployable composite boom tower, a capability to correct static deflections during and after deployment may be required. This paper presents a pathfinder deployable guy wire stability system for the MIT / LaRC self-erecting composite boom lunar tower that provides real time measurements, maintains tension passively, and can serve as a reconfigurable platform to test new guy wire components, configurations and control algorithms. Using a validated, calibrated photogrammetry system, the natural lateral deflection of the boom tip relative to the boom base at different deployed heights in Earth’s gravity field was recorded. With real-time tension measurements it was found that guy wires can significantly reduce the tip deflection of a deployable composite boom under dead load. Specifically, we found that (1) control capability is greatest where it is needed most, i.e. for the lever arm closest to being opposite the direction of deflection, and (2) for a tower height of at least 8.5 m and arm length of at least 60 cm, a solution of differential tension in all three arms exists and, in principle, provides sufficient control capability to correct or significantly reduce boom deflections. We also found that natural deflections occur almost entirely out-of-plane of the seams of the boom cross-section, which was expected, and that the natural boom tip lateral deflection under dead load upon deployment was ~5% of boom deployed length, unexpectedly exceeding the manufacturing acceptance specification of 1%.Ongoing and future collaborative work between LaRC and MIT includes the further investigation of the unexpected lateral deflection, testing of alternative guy wire system designs at higher tensions and higher deployed heights, as well as trade studies of costs and benefits of an optimized integrated guywire system compared to other types of static stability solutions.

lunar towers↗

Monitoring of the MU radar antenna pattern by Satellite Ohzora (EXOS-C)

As the first attempt among MST (mesosphere stratosphere troposphere) type radars, the MU (middle and upper atmosphere) radar features an active phased array system. Unlike the conventional large VHF radars, in which output power of a large vacuum tube is distributed to individual antenna elements, each of 475 solid state power amplifier feeds each antenna element. This system configuration enables very fast beam steering as well as various flexible operations by dividing the antenna into independent subarrays, because phase shift and signal division/combination are performed at a low signal level using electronic devices under control of a computer network. The antenna beam can be switched within 10 microsec to any direction within the zenith angle of 30 deg. Since a precise phase alignment of each element is crucial to realize the excellent performance of this system, careful calibration of the output phase of each power amplifier and antenna element was carried out. Among various aircraft which may be used for this purpose artificial satellites have an advantage of being able to make a long term monitoring with the same system. An antenna pattern monitoring system for the MU radar was developed using the scientific satellite OHZORA (EXOS-C). A receiver named MUM (MU radar antenna Monitor) on board the satellite measures a CW signal of 100 to 400 watts transmitted from the MU radar. The principle of the measurement and results are discussed.

Sato, T.↗

High intensity 5 eV O-atom exposure facility for material degradation studies

An atomic oxygen exposure facility was developed for studies of material degradation. The goal of these studies is to provide design criteria and information for the manufacture of long life (20 to 30 years) construction materials for use in low Earth orbit. The studies that are being undertaken will provide: (1) absolute reaction cross sections for the engineering design problems, (2) formulations of reaction mechanisms for use in the selection of suitable existing materials and the design of new more resistant ones, and (3) the calibration of flight hardware (mass spectrometers, etc.) in order to directly relate experiments performed in low Earth orbit to ground based investigations. The facility consists of a CW laser sustained discharge source of O-atoms, an atomic beam formation and diagnostics system, a spinning rotor viscometer, and provision for using the system for calibration of actual flight instruments.

Cross, J. B.↗

Methane on Mars: New Insights into the Sensitivity of CH4 with the NOMAD/ExoMars Spectrometer Through Its First In-Flight Calibration

The Nadir and Occultation for MArs Discovery instrument (NOMAD), onboard the ExoMars Trace Gas Orbiter (TGO) spacecraft was conceived to observe Mars in solar occultation, nadir, and limb geometries, and will be able to produce an outstanding amount of diverse data, mostly focused on properties of the atmosphere. The infrared channels of the instrument operate by combining an echelle grating spectrometer with an Acousto- Optical Tunable Filter (AOTF). Using in-flight data, we characterized the instrument performance and parameterized its calibration. In particular: an accurate frequency calibration was achieved, together with its variability due to thermal effects on the grating. The AOTF properties and transfer function were also quantified, and we developed and tested a realistic method to compute the spectral continuum transmitted through the coupled grating and AOTF system. The calibration results enabled unprecedented insights into the important problem of the sensitivity of NOMAD to methane abundances in the atmosphere. We also deeply characterized its performance under realistic conditions of varying aerosol abundances, diverse albedos and changing illumination conditions as foreseen over the nominal mission. The results show that, in low aerosol conditions, NOMAD single spectrum, 1σ sensitivity to CH4 is around 0.33 ppbv at 20 km of altitude when performing solar occultation's, and better than 1 ppbv below 30 km. In dusty conditions, we show that the sensitivity drops to 0 below 10 km. In Nadir geometry, results demonstrate that NOMAD will be able to produce seasonal maps of CH4 with a sensitivity around 5 ppbv over most of planet's surface with spatial integration over 5×5° bins. Results show also that such numbers can be improved by a factor of ~10 to ~30 by data binning. Overall, our results quantify NOMAD's capability to address the variable aspects of Martian climate.

Liuzzi, Giuliano↗

AXAF Alignment Test System Autocollimating Flat Error Correction

The alignment test system for the advanced x ray astrophysics facility (AXAF) high-resolution mirror assembly (HRMA) determines the misalignment of the HRMA by measuring the displacement of a beam of light reflected by the HRMA mirrors and an autocollimating flat (ACF). This report shows how to calibrate the system to compensate for errors introduced by the ACF, using measurements taken with the ACF in different positions. It also shows what information can be obtained from alignment test data regarding errors in the shapes of the HRMA mirrors. Simulated results based on measured ACF surface data are presented.

Lewis, Timothy S.↗

The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-Rotors

During the course of the Kennedy Space Center Summer Internship, two main experiments were performed: The Vacuum-Compacted Regolith Gripping Mechanism and Unmanned Flights via Quad-copters. The objectives of the Vacuum-Compacted Regolith Gripping Mechanism, often abbreviated as the Granular Gripper, are to exhibit Space Technology, such as a soft robotic hand, lift different apparatuses used to excavate regolith, and conserve energy while executing its intended task. The project is being conducted to test how much weight the Granular Gripper can hold. With the use of an Animatronic Robotic Hand, Arduino Uno, and other components, the system was calibrated before actually conducting the intended weight test. The maximum weight each finger could hold with the servos running, in the order of pinky, ring, middle, and index fingers, are as follows: 1.340N, 1.456 N, 0.9579 N, and 1.358 N. Using the small vacuum pump system, the maximum weight each finger could hold, in the same order, was: 4.076 N, 6.159 N, 5.454 N, and 4.052 N. The maximum torques on each of the fingers when the servos were running, in the same respective order, was: 0.0777 Nm, 0.0533 Nm, 0.0648 Nm, and 0.0532 Nm. The maximum torques on the individual fingers, when the small vacuum pump was in effect, in the same order as above, was: 0.2318 Nm, 0.3032 Nm, 0.2741 Nm, and 0.1618 Nm. In testing all the fingers with the servos running, the total weight was 5.112 N and the maximum torque on the all the fingers was 0.2515 Nm. However, when the small vacuum pump system was used, the total weight was 19.741 N and the maximum torque on the all the fingers was 0.9713 Nm. The conclusion that was drawn stated that using the small vacuum pump system proved nearly 4 times more effective when testing how much weigh the hand could hold. The resistance provided by the compacted sand in the glove allowed more weight to be held by the hand and glove. Also, when the servos turned off and the hand still retaining its position, energy is being saved because the vacuum created the same resistance the running servos did without using power. The Unmanned Flights via Quad-rotors are built because multi-rotor dynamics are an important starting point and fair analog for space craft control systems and they make good terrestrial development platforms for various aspects of control for space crafts. The project is being conducted to see what the thrust response is going to be when a pulse width modulation command is sent to the control system since the quad-rotors are PWM controlled. A simulation environment in constructed so that one can quickly iterate and test different designs such as control systems, PID control vs. LDR control, and state estimation. Using two DIY Quad Kits, APM 2.6, testing apparatus (called a data acquisition system) to test the quad-rotors, and a simulation program such as Simulink, two quad-rotors are built and controlled via a simulation program, which is designed to be as realistic as possible and not idealistic. Due to the quad-rotors not being completely built nor ready for testing, there are no results or conclusions to report.

Granular Gripper↗

Evaluation of usefulness of Skylab EREP S-190 and S-192 imagery in multistage forest surveys

The author has identified the following significant results. The digital timber volume prediction system was tested with another test area in the Trinity Alps. The estimated gain in precision was somewhat lower than the estimate for the first test area (35%). A combined interpretation of the two areas was made, yielding an estimated gain of 44%, with high statistical significance. This interpretation was used to calibrate the system for an interpretation of 43 primary sample units distributed over 1600 square miles. Preliminary results indicate that a gain of 35% can be realized over this large area in northern California.

Langley, P. G.↗

Global Monitoring of Clouds and Aerosols Using a Network of Micro-Pulse Lidar Systems

Long-term global radiation programs, such as AERONET and BSRN, have shown success in monitoring column averaged cloud and aerosol optical properties. Little attention has been focused on global measurements of vertically resolved optical properties. Lidar systems are the preferred instrument for such measurements. However, global usage of lidar systems has not been achieved because of limits imposed by older systems that were large, expensive, and logistically difficult to use in the field. Small, eye-safe, and autonomous lidar systems are now currently available and overcome problems associated with older systems. The first such lidar to be developed is the Micro-pulse lidar System (MPL). The MPL has proven to be useful in the field because it can be automated, runs continuously (day and night), is eye-safe, can easily be transported and set up, and has a small field-of-view which removes multiple scattering concerns. We have developed successful protocols to operate and calibrate MPL systems. We have also developed a data analysis algorithm that produces data products such as cloud and aerosol layer heights, optical depths, extinction profiles, and the extinction-backscatter ratio. The algorithm minimizes the use of a priori assumptions and also produces error bars for all data products. Here we present an overview of our MPL protocols and data analysis techniques. We also discuss the ongoing construction of a global MPL network in conjunction with the AERONET program. Finally, we present some early results from the MPL network.

Welton, Ellsworth J.↗

Radiometric Measurement Comparisons Using Transfer Radiometers in Support of the Calibration of NASA's Earth Observing System (EOS) Sensors

EOS satellite instruments operating in the visible through the shortwave infrared wavelength regions (from 0.4 micrometers to 2.5 micrometers) are calibrated prior to flight for radiance response using integrating spheres at a number of instrument builder facilities. The traceability of the radiance produced by these spheres with respect to international standards is the responsibility of the instrument builder, and different calibration techniques are employed by those builders. The National Aeronautics and Space Administration's (NASA's) Earth Observing System (EOS) Project Science Office, realizing the importance of preflight calibration and cross-calibration, has sponsored a number of radiometric measurement comparisons, the main purpose of which is to validate the radiometric scale assigned to the integrating spheres by the instrument builders. This paper describes the radiometric measurement comparisons, the use of stable transfer radiometers to perform the measurements, and the measurement approaches and protocols used to validate integrating sphere radiances. Stable transfer radiometers from the National Institute of Standards and Technology, the University of Arizona Optical Sciences Center Remote Sensing Group, NASA's Goddard Space Flight Center, and the National Research Laboratory of Metrology in Japan, have participated in these comparisons. The approaches used in the comparisons include the measurement of multiple integrating sphere lamp levels, repeat measurements of select lamp levels, the use of the stable radiometers as external sphere monitors, and the rapid reporting of measurement results. Results from several comparisons are presented. The absolute radiometric calibration standard uncertainties required by the EOS satellite instruments are typically in the +/- 3% to +/- 5% range. Preliminary results reported during eleven radiometric measurement comparisons held between February 1995 and May 1998 have shown the radiance of integrating spheres agreed to within +/- 2.5% from the average at blue wavelengths and to within +/- 1.7% from the average at red and near infrared wavelengths. This level of agreement lends confidence in the use of the transfer radiometers in validating the radiance scales assigned by EOS instrument calibration facilities to their integrating sphere sources.

Butler, James J.↗

Specification of EBR-II Contact Profilometry Data

All contact profilometry data stored in FIPD was originally measured using the HFEF vertical contact profilometer, which was an electronic gauge to measure the diameter profile of an element or capsule continuously over the region of interest. The element could be rotated as it passed through the probes if the wire wrap was not to be removed and the element could be returned to reactor for further irradiation. If the wire wrap was removed, the element could be drawn vertically through the probes, rotated, and the process repeated. In this way any cladding ovality could be observed. Figure 1 shows the setup used to measure the fuel pin diameter profile. The ambient temperature during the measurement was ~21-23 ºC. The cladding temperature during the measurement is considered to be similar to the ambient temperature by assuming the fuel decay heat did not impact the cladding temperature. Two documents contain most of the important details about contact profilometry measurements. The first one is the operational manual of the contact profilometer (title: Element contact profilometer operation and maintenance, HFEF/N OMM 4326, DOC. NO. W0202-0007-SA-01). This manual provides: (1) description of the contact profilometer including the functions of each component (support stage, sensing head, control system, and calibration standards, etc.); (2) step-by-step guidance on calibrations, operations, and measurements; and (3) maintenance procedures and other details of the contact profilometer. The second document is a publicly accessible report entitled “A Fuel-element Profilometer for the HFEF.” This report describes the development of the contact profilometer, including the design requirements, features, and details of each component, as well as the acceptance tests for the built system. This document is important because it reports the uncertainties of the measurements with detailed deduction procedures. The reported uncertainties should apply to all hard-copy contact profilometry data in FIPD. Some key information about contact profilometry measurements was extracted from these two documents. Combining the information with other sources, a specification for interpretating the contact profilometry data in FIPD was established.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recent modifications and calibration of the Langley low-turbulence pressure tunnel

Modifications to the Langley Low-Turbulence Pressure Tunnel are presented and a calibration of the mean flow parameters in the test section is provided. Also included are the operational capability of the tunnel and typical test results for both single-element and multi-element airfoils. Modifications to the facility consisted of the following: replacement of the original cooling coils and antiturbulence screens and addition of a tunnel-shell heating system, a two dimensional model-support and force-balance system, a sidewall boundary layer control system, a remote-controlled survey apparatus, and a new data acquisition system. A calibration of the mean flow parameters in the test section was conducted over the complete operational range of the tunnel. The calibration included dynamic-pressure measurements, Mach number distributions, flow-angularity measurements, boundary-layer characteristics, and total-pressure profiles. In addition, test-section turbulence measurements made after the tunnel modifications have been included with these calibration data to show a comparison of existing turbulence levels with data obtained for the facility in 1941 with the original screen installation.

Mcghee, R. J.↗

Completing the forward kinematic calibration of open loop manipulators when single point position sensors are used

Single-point sensors can measure the position of one point fixed to a manipulator's end effector. When single-point sensors have been used for calibration, it has not been possible to calibrate the orientation of the tool. Furthermore, it can be difficult to calibrate the sensor system. Results in the literature seldom provide a complete kinematic calibration of the manipulator. Presented here is a technique that enables single-point sensors to gather sufficient information to complete kinematic calibration. In addition, the method can reduce the burden of calibrating the sensor system.

Everett, Louis J.↗

Spectroradiometric calibration of the thematic mapper and multispectral scanner system

The results obtained for the absolute calibration of TM bands 2, 3, and 4 are presented. The results are based on TM image data collected simultaneously with ground and atmospheric data at White Sands, New Mexico. Also discussed are the results of a moments analysis to determine the equivalent bandpasses, effective central wavelengths and normalized responses of the TM and MSS spectral bands; the calibration of the BaSO, plate used at White Sands; and future plans.

Slater, P. N.↗

Spectroradiometric calibration of the Thematic Mapper and multispectral scanner system

The eleventh quarterly report on Spectroradiometric Calibration of the Thematic Mapper (Contract NAS5-27832) discusses calibrations made at White Sands on 24 May 1985. An attempt is made to standardize test results. Critical values used in the final steps of the data reduction and the comparison of the results of the pre-flight and internal calibration (IC) data are summarized.

Slater, P. N.↗

Study of precise positioning at L-band using communications satellites

The L-band positioning experiment is reported which encompassed experiment design, experimentation, and data reduction and analysis. In the experiment the ATS-5 synchronous satellite L-band transponder was used in conjunction with the modified ALPHA 2 navigation receivers to demonstrate the technical capability of precision position fixing for oceanographic purposes. The feasibility of using relative ranging techniques implemented by two identical receiving systems, properly calibrated, to determine a line of position accurately on the surface of the earth was shown. The program demonstrated the level of resolution, repeatibility, precision, and accuracy of existing modest-cost effective navigation equipment. The experiment configuration and data reduction techniques were developed in parallel with the hardware modification tasks. Test results verify the ability of a satellite-based system to satisfy the requirements of precision position fixing.

Source record↗