Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “synchrotron imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

3D Experimental Measurements of Evolution of Force Chains in Natural Silica Sand

The mechanisms of force transmission in granular materials is a classic physics problem that has been addressed since the 19th century, when Heinrich Rudolf Hertz investigated the interaction between two similar objects that were in contact under compression. However, the study of force transmission mechanisms in assemblies of more particles has proven to be a formidable problem due to the complex nature of granular materials. In recent years, synchrotron microcomputed tomography (SMT) and three-dimensional X-ray diffraction microscopy (3DXRD) have been employed to study the mechanics of granular materials experimentally. Combining SMT and 3DXRD offers unique three-dimensional (3D) experimental measurements of the internal structure, kinematics (such as rotation and translation), and lattice strains of individual sand particles. In this paper, in situ SMT and 3DXRD scans were acquired at multiple load steps for a specimen composed of 2,705 natural Ottawa sand particles that were subjected to one-dimensional (1D) confined compression. An algorithm was developed to combine SMT images and 3DXRD lattice strain measurements and used to characterize the constitutive behavior of sand particles. The results were used to identify the crystal structure and the evolution of the stresses and lattice strains of individual sand particles. Another algorithm was developed to characterize the force structures within the specimen. Force structures were identified, and their properties (such as length) and evolution through the experiment were examined. The contact number of particles is a particle-scale property that affects the mechanics of granular materials. The effect of the contact number of the sand particles on the onset and evolution of the force structures was also investigated and discussed.

3D x-ray diffraction microscopy↗

Vacuum ultraviolet instrumentation for solar irradiance and thermospheric airglow

A NASA sounding rocket experiment was developed to study the solar extreme ultraviolet (EUV) spectral irradiance and its effect on the upper atmosphere. Both the solar flux and the terrestrial molecular nitrogen via the Lyman-Birge-Hopfield bands in the far ultraviolet (FUV) were measured remotely from a sounding rocket on October 27, 1992. The rocket experiment also includes EUV instruments from Boston University (Supriya Chakrabarti), but only the National Center for Atmospheric Research (NCAR)/University of Colorado (CU) four solar instruments and one airglow instrument are discussed here. The primary solar EUV instrument is a 1/4 meter Rowland circle EUV spectrograph which has flown on three rockets since 1988 measuring the solar spectral irradiance from 30 to 110 nm with 0.2 nm resolution. Another solar irradiance instrument is an array of six silicon XUV photodiodes, each having different metallic filters coated directly on the photodiodes. This photodiode system provides a spectral coverage from 0.1 to 80 nm with about 15 nm resolution. The other solar irradiance instrument is a silicon avalanche photodiode coupled with pulse height analyzer electronics. This avalanche photodiode package measures the XUV photon energy providing a solar spectrum from 50 to 12,400 eV (25 to 0.1 nm) with an energy resolution of about 50 eV. The fourth solar instrument is an XUV imager that images the sun at 17.5 nm with a spatial resolution of 20 arc-seconds. The airglow spectrograph measures the terrestrial FUV airglow emissions along the horizon from 125 to 160 nm with 0.2 nm spectral resolution. The photon-counting CODACON detectors are used for three of these instruments and consist of coded arrays of anodes behind microchannel plates. The one-dimensional and two-dimensional CODACON detectors were developed at CU by Dr. George Lawrence. The pre-flight and post-flight photometric calibrations were performed at our calibration laboratory and at the Synchrotron Ultraviolet Radiation Facility (SURF) at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland.

Woods, Thomas N.↗

Universal chemomechanical design rules for solid-ion conductors to prevent dendrite formation in lithium metal batteries

Dendrite formation during electrodeposition while charging lithium metal batteries compromises their safety. Although high-shear-modulus ( G s ) solid-ion conductors (SICs) have been prioritized to resolve the pressure-driven instabilities that lead to dendrite propagation and cell shorting, it is unclear whether these or alternatives are needed to guide uniform lithium electrodeposition, which is intrinsically density-driven. Here, we show that SICs can be designed within a universal chemomechanical paradigm to access either pressure-driven dendrite-blocking or density-driven dendrite-suppressing properties, but not both. This dichotomy reflects the competing influence of the SIC’s mechanical properties and the partial molar volume of Li + $(V_{\mathrm{Li}^+})$ relative to those of the lithium anode ( G Li and V Li ) on plating outcomes. Within this paradigm, we explore SICs in a previously unrecognized dendrite-suppressing regime that are concomitantly ‘soft’, as is typical of polymer electrolytes, but feature an atypically low $(V_{\mathrm{Li}^+})$ that is more reminiscent of ‘hard’ ceramics. Li plating (1 mA cm -2 ; T = 20 °C) mediated by these SICs is uniform, as revealed using synchrotron hard X-ray microtomography. As a result, cell cycle life is extended, even when assembled with thin Li anodes (~30 µm) and either high-voltage NMC-622 cathodes (1.44 mAh cm -2 ) or high-capacity sulfur cathodes (3.02 mAh cm -2 ).

25 ENERGY STORAGE↗

Towards scanning nanostructure X-ray microscopy

This article demonstrates spatial mapping of the local and nanoscale structure of thin film objects using spatially resolved pair distribution function (PDF) analysis of synchrotron X-ray diffraction data. This is exemplified in a lab-on-chip combinatorial array of sample spots containing catalytically interesting nanoparticles deposited from liquid precursors using an ink-jet liquid-handling system. A software implementation is presented of the whole protocol, including an approach for automated data acquisition and analysis using the atomic PDF method. The protocol software can handle semi-automated data reduction, normalization and modeling, with user-defined recipes generating a comprehensive collection of metadata and analysis results. By slicing the collection using included functions, it is possible to build images of different contrast features chosen by the user, giving insights into different aspects of the local structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optical imagery and spectrophotometry of CTB 80

Narrow-band imagery and spectrophotometry of the central region of CTB 80 are presented. The images show weak forbidden O III and ubiquitous filamentary forbidden S II and H-alpha emission from the extended radio lobes in which the core is embedded. The data indicate that the extended component is shock heated. Balmer line-dominated emission is observed around the perimeter of the core. Assuming that the volume of the radio shell is similar to the volume of the thermal shell, it is found that a magnetic field of about 600 microG and a cosmic-ray proton-to-electron ratio of about 200 are required to explain the pressure and synchrotron volume emissivity in the radio shell. It is suggested that the optical emission form the core of CTB 80 arises behind shocks which are being driven into a magnetized thermal plasma by the confined relativistic wind from PSR 1951+32.

Hester, J. Jeff↗

Structure of the X-Ray Emission from the Jet of 3C 273

We present images from four Chandra observations of the quasar 3C 273. The zeroth order images from two grating observations using the AXAF CCD Imaging Spectrometer (ACIS-S) detector are used to examine the structure and spectrum of the jet. The jet has at least four distinct features which are not resolved in previous observations. Using jet feature nomenclature based on HST observations, we find that knot Al is very bright in X-rays. We have measured the X-ray spectrum of this X-ray knot for the first time, obtaining a photon index of 1.36 +/- 0.11 and a flux density of 37 +/- 4 nJy at 1 keV. Combining this measurement with lower frequency data shows that a pure synchrotron model can fit the spectrum of knot Al from 4 GHz to 5 keV (over nine decades in energy) without a change of spectral slope. Knot A2 is also detected and is somewhat blended with knot B1 but synchrotron emission is not likely to explain the X-ray emission due to the spectral turnover observed in the optical-UV band. No other knots are clearly detected but there is an indication of weak emission from the eastern portion of knot H3. near the "head," which is radio-bright. There is diffuse flux which extends from 14 arcsec to 20 arcsec which shows curvature that is comparable to the optical flux found by Bahcall, et al.

Marshall, H. L.↗

The Mapping X-Ray Fluorescence Spectrometer (MAPX)

MapX will provide elemental imaging at ≤100 micron spatial resolution over 2.5 X 2.5 centimeter areas, yielding elemental chemistry at or below the scale length where many relict physical, chemical, and biological features can be imaged and interpreted in ancient rocks. MapX is a full-frame spectroscopic imager positioned on soil or regolith with touch sensors. During an analysis, an X-ray source (tube or radioisotope) bombards the sample surface with X-rays or αlpha-particles / gamma rays, resulting in sample X-ray Fluorescence (XRF). Fluoresced X-rays pass through an X-ray lens (X-ray μ-Pore Optic, "MPO") that projects a spatially resolved image of the X-rays onto a CCD. The CCD is operated in single photon counting mode so that the positions and energies of individual photons are retained. In a single analysis, several thousand frames are stored and processed. A MapX experiment provides elemental maps having a spatial resolution of ≤100 micron and quantitative XRF spectra from Regions of Interest (ROI) 2 centimers ≤ x ≤ 100 micron. ROI are compared with known rock and mineral compositions to extrapolate the data to rock types and putative mineralogies. The MapX geometry is being refined with ray-tracing simulations and with synchrotron experiments at SLAC. Source requirements are being determined through Monte Carlo modeling and experiment using XMIMSIM [1], GEANT4 [2] and PyMca [3] and a dedicated XRF test fixture. A flow-down of requirements for both tube and radioisotope sources is being developed from these experiments. In addition to Mars lander and rover missions, MapX could be used for landed science on other airless bodies (Phobos/Deimos, Comet nucleus, asteroids, the Earth's moon, and the icy satellites of the outer planets, including Europa.

Blake, David↗

3D printed water-stable Cd-doped Cs 4 MnBi 2 Cl 12 /polylactic acid perovskite/polymer composites for high-flux X-ray scintillation

Stable and efficient X-ray scintillators are crucial for medical diagnostics, industrial, and defense applications. However, conventional scintillator technologies face a trade-off between stability, optimal performance, and sustainability. Herein, we introduce 3D-printed Cs 4 MnBi 2 Cl 12 (Pero1) and Cs 4 Cd 0.68 Mn 0.32 Bi 2 Cl 12 (Pero2) perovskite microcrystals embedded within a polylactic acid (PLA) polymer composite as X-ray scintillators, combining efficiency, stability, and sustainability. The orange luminescent perovskite powder phosphors exhibited poor water stability, which was successfully addressed through incorporation into PLA via filament extrusion and fused deposition modeling (FDM) 3D printing. The resulting composite films demonstrated remarkable water stability while maintaining uniform orange emission throughout the polymer matrix, as confirmed by 3D topography scanning and X-ray fluorescence mapping. Structural characterization revealed minimal chemical interaction between the perovskite and PLA matrix, with the composites retaining their crystalline properties. The PLA-Pero2 composite exhibited superior optical properties, with a photoluminescence quantum yield of 47%, nearly 17 times higher than that of PLA-Pero1 (2.8%), attributed to the effective suppression of non-radiative decay pathways through Cd 2+ doping. Under hard X-ray irradiation at synchrotron beamlines, both composites exhibited excellent radioluminescence, with emission peaks at 605 nm, a linear response across a wide X-ray flux range, and remarkable radiation stability, showing less than 3% intensity degradation after 600 seconds of continuous high-dose exposure. The PLA-Pero2 composite achieved a spatial resolution of 5 line pairs per millimeter and a contrast ratio of 0.255. These performance metrics, combined with the polymer's biodegradability and scalability through additive manufacturing, position PLA-based composites as a more sustainable alternative to conventional petroleum-based polymer scintillators for next-generation medical imaging, radiation monitoring, and industrial radiography applications.

3D Printing↗

Constraints on electron acceleration in the Crab nebula

Using the radio through hard X-ray images of the Crab nebula to derive the spatial dependence of the electron spectrum and the magnetic field distribution from MHD flow models, we have rederived the high-energy spectrum of inverse Compton scattered gamma rays. We find agreement with the observed spectrum at TeV energies, but it is clear that the inverse Compton flux does not contribute significantly to the unpulsed nebular emission observed by COS-B from 50 to 500 MeV, which is consistent with a smooth continuation of the spectrum in hard X-rays. The emission at these energies must therefore be due to synchrotron radiation by electrons of at least PeV energies. It appears that the emission in the high-energy gamma-ray range, sensitive to the highest energy electrons in the nebula, can put interesting constraints on the acceleration mechanism.

Harding, A. K.↗

Tin-polyimide and indium-polyimide thin-film composites as soft X-ray bandpass filters

A tin-polyimide and an indium-polyimide soft X-ray bandpass filter were fabricated with thicknesses of 1400 and 1750 A for the metal and polyimide components, respectively. The transmission of each filter was measured at the Stanford Synchrotron Radiation Laboratory. The transmission of the tin-polyimide filter was found to be about 40 percent for radiation with wavelengths between 60 and 80 A. The transmission of the indium-polyimide filter was greater than 40 percent between 70 and 90 A. The indium was about 5 percent more transmissive than the tin and attained a maximum transmission of about 48 percent at 76 A. Such filters have potential applications to soft X-ray telescopes that operate in this region. They might also be of interest to investigators who work with X-ray microscopes that image live biological specimens in the 23-44-A water window.

Powell, Stephen F.↗

Advanced monolithic 2D multilayer Laue lens (MLL) optics for hard x-ray nanofocusing and nanotomography

We report on the development of a new generation of monolithic two-dimensional (2D) multilayer Laue lens (MLL) optics suitable for high-resolution hard x-ray nanoimaging. The 2D optics were assembled on microfabricated silicon templates with high orthogonality and lateral alignment precision, which were characterized using white-light interferometry and confirmed by x-ray measurements. The developed monolithic 2D MLL optics were successfully employed for hard x-ray nanofocusing and nanotomography experiments using the ptychography imaging modality, demonstrating sub-10 nm resolution in 2D and sample-limited ∼30 nm in three-dimensional while exhibiting excellent stability during extended measurements. The new 2D MLL templates with high alignment accuracy represent an important step forward in the development of 2D MLL optics toward direct nanoimaging experiments with sub-10 nm spatial resolution.

36 MATERIALS SCIENCE↗

Work function lowering of LaB 6 by monolayer hexagonal boron nitride coating for improved photo- and thermionic-cathodes

We report a lowering of work function for lanthanum hexaboride (LaB 6 ) by monolayer hexagonal boron nitride (hBN) coating. Photoemission electron microcopy (PEEM) and thermionic emission electron microscopy (TEEM) both revealed that the hBN coated region of a LaB 6 (100) single crystal has a lower work function compared to the bare (i.e., non-coated) and graphene coated regions. A broad and uniform brighter image of the hBN coated region in PEEM was quantitatively supported by a 0.4 eV decrease in the work function in photoelectron spectra compared to the bare region. TEEM results were consistent in that the hBN coated region exhibited thermionic emission at 905 °C, whereas the bare and graphene coated regions did not. A larger decrease in the work function for hBN coated LaB 6 (100) compared to graphene coated LaB 6 (100) was qualitatively supported by our density functional theory calculations. Adding an oxide layer in the calculations improved consistency between the calculation and experimental results. We followed up our calculations with synchrotron-radiation x-ray photoelectron spectroscopy and confirmed the presence of an oxide layer on our LaB 6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Galaxy Clusters Discovered via the Thermal Sunyaev-Zel’dovich Effect in the 500-square-degree SPTpol Survey

We present a catalog of 689 galaxy cluster candidates detected at significance ξ > 4 via their thermal Sunyaev-Zel’dovich (SZ) effect signature in 95 and 150 GHz data from the 500-square-degree SPTpol survey. We use optical and infrared data from the Dark Energy Camera and the Wide-field Infrared Survey Explorer (WISE) and Spitzer satellites, to confirm 544 of these candidates as clusters with ~ 94% purity. The sample has an approximately redshift-independent mass threshold at redshift z > 0.25. The confirmed sample spans 1.5 × 10 14 < M 500 c < 9 × 10 14 M ⊙ /h 70 and 0.03 < z ≲ 1.6 in mass and redshift, respectively, with a median mass of 2.5×10 14 M ⊙ /h 70 and median redshift z = 0.7; 21% of the confirmed clusters are at z > 1. We use external radio data from the Sydney University Molonglo Sky Survey (SUMSS) to estimate contamination to the SZ signal from synchrotron sources. The contamination reduces the recovered ξ by a median value of 0.032, or ~ 0.8% of the ξ = 4 threshold value, and ~ 7% of candidates have a predicted contamination greater than Δξ = 1. With the exception of a small number of systems (< 1%), an analysis of clusters detected in single-frequency 95 and 150 GHz data shows no significant contamination of the SZ signal by emission from dusty or synchrotron sources. This cluster sample, representing the deepest SZ-selected cluster sample to date, will be a key component in upcoming astrophysical and cosmological analyses of clusters. In addition to the cluster catalog, we also release the millimeter-wave maps and associated data products used to produce this sample. These maps have depths of 5.3 (11.7) µK CMB -arcmin at 150 (95) GHz and an effective angular resolution of 1. '2 (1. '7). The SPTpol products are available at https:// pole.uchicago.edu/public/data/sptpol_500d_clusters/index.html, and the NASA LAMBDA website. An interactive sky server with the SPTpol maps and Dark Energy Survey data release 2 images is also available at NCSA https://skyviewer.ncsa.illinois.edu.

79 ASTRONOMY AND ASTROPHYSICS↗

Radio and X-ray observations of the gamma-ray bright quasar PKS 0528+134

We present a study of the z = 2.07 quasar PKS 0528+134, which has been detected as an extraordinarily luminous gamma-ray source. Its radio properties are highly variable in both total and polarized flux density. Milliarcsecond-scale maps from global very long base interferometry (VLBI) experiments, an X-ray spectrum from ROSAT Position Sensitive Proportional Counter (PSPC) observations, and light curves in total flux density and polarization are used to investigate the geometry, radiation mechanism, and physical environment of the emission region in the source. The VLBI images reveal a bent jet extending toward the northeast on parsec scales, with less intense knots of emission appearing on the opposite side of the brightest spot. The position of the core usually found in such sources is unclear. The polarization angle is stable despite strong variability in polarized flux density and indicates that the magnetic field is aligned with the jet axis as defined by our 8.4 GHz image. The ROSAT X-ray flux density of PKS 0528+134 in 1991 March is measured to be 1.6 micro Jy at 1 keV, with a very steep spectral (`energy') index sigma(sub x) approximately equal to 2.2. The X-ray observations reveal the presence of cold gas along the line of sight significantly in excess of that present in the Galaxy. A strong radio flare began within two months of the first observation of a high flux of gamma-rays from PKS 0528+134 by Hunter et al. Using the geometry and spectral chacateristics determined by our VLBI observations, a synchrotron self-Compton calculation indicates that relativistic bulk motion is required in PKS 0528+134, with an estimated Doppler beaming factor delta approximately greater than 4.3, similar to the value delta approximately greater than 7 required to explain the low optical depth of the gamma-rays to photon-photon pair production. We suggest that the core activity of PKS 0528+134 is sporadic in nature, with the nonthermal outburst starting in 1991 representing a violent period involving ejection of relativistic plasma along a compact jet pointed almost directly toward us.

Zhang, Yun Fei↗

PyXAS – an open-source package for 2D X-ray near-edge spectroscopy analysis

In the synchrotron X-ray community, X-ray absorption near-edge spectroscopy (XANES) is a widely used technique to probe the local coordination environment and the oxidation states of specific elements within a sample. Although this technique is usually applied to bulk samples, the advent of new synchrotron sources has enabled spatially resolved versions of this technique (2D XANES). This development has been extremely powerful for the study of heterogeneous systems, which is the case for nearly all real applications. However, associated with the development of 2D XANES comes the challenge of analyzing very large volumes of data. As an example, a single 2D XANES measurement at a synchrotron can easily produce ~106 spatially resolved XANES spectra. Conventional manual analysis of an individual XANES spectrum is no longer feasible. Here, a software package is described that has been developed for high-throughput 2D XANES analysis. A detailed description of the software as well as example applications are provided.

25 ENERGY STORAGE↗

Collimated phase measuring deflectometry II: Re-design of the optical layout for high-curvature surfaces

Collimated phase measuring deflectometry (CPMD) is an optical metrology technique developed to improve upon traditional phase measuring deflectometry (PMD). CPMD utilizes telecentric imaging and collimated structured light illumination to eliminate the height-slope ambiguity present in traditional PMD measurements. After the publication of the first CPMD paper, efforts began to optimize the optical layout of the CPMD system. The first proposed change, and the one detailed in this work, was to move the Fourier transform (FT) lens closer to the surface under test (SUT). Moving the FT lens closer to the SUT meant that for a given FT lens diameter, a larger range of surface slopes on the SUT could be measured. This change to the optical layout was not trivial and introduced at least two concerns that had to be addressed: telecentricity in the imaging path and possible ghost reflections from the re-located FT lens. Here, in this work, we examine how these concerns were addressed and present results showing that the revised optical layout is capable of measurement results at least as good as the original CPMD optical layout. We also demonstrate the increased slope measuring range of the revised optical layout.

47 OTHER INSTRUMENTATION↗

High-energy X-ray imaging with a Germanium MM-PAD hybrid pixel detector

Germanium is a high-Z sensor material with excellent energy resolution and attractive properties for high-energy photon detection. Despite its advantages, the need for cryogenic operation and challenges in the fabrication of pixelated high-purity germanium have hindered the development of segmented detectors. We report on the fabrication and performance of a germanium imaging detector with 150 μm pixel pitch hybridized to the MM-PAD ASIC. The detector was capable of high-resolution radiographic imaging and has a fast temporal response. Additionally, we describe the detector's upper operating temperature limits using both the MM-PAD and MARS ASICs, achieving stable operation up to 130 K and 190 K, respectively.

36 MATERIALS SCIENCE↗

High-Frequency Observations of Blazars

We report on the results of high-frequency VLBA observations of 42 gamma ray bright blazars monitored at 22 and 43 GHz between 1993.9 and 1997-6. In 1997 the observations included polarization-sensitive imaging. The cores of gamma ray blazars are only weakly polarized, with EVPAs (electric-vector position angles) usually within 40 degrees of the local direction of the jet. The EVPAs of the jet components are usually within 20 degrees of the local jet direction. The apparent speeds of the gamma ray bright blazars are considerably faster than in the general population of bright compact radio sources. Two X-ray flares (observed with RXTE) of the quasar PKS 1510-089 appear to be related to radio flares, but with the radio leading the X-ray variations by about 2 weeks. This can be explained either by synchrotron self-Compton emission in a component whose variations are limited by light travel time or by the Mirror Compton model.

Marscher, A. P.↗