Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spallation source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

Melting temperature measurement of refractory oxide ceramics as a function of oxygen fugacity using containerless methods

An aerodynamic conical nozzle levitator (CNL) has been used to measure the melting temperatures of refractory ceramics. The well-established method of cooling traces has been adapted to allow measurements for air-sensitive samples using a controlled atmosphere, where the oxygen partial pressure can be adjusted and monitored in real time. In this study, we explain the details of a system that we developed for use at the Spallation Neutron Source (Oak Ridge National Laboratory). Measurements of the melting behavior of (Fe,Cr,Al) 3 O 4 spinels were made between log (PO 2 (atm)) of -0.7 and -5. The melting temperature of hercynite is found to be oxygen potential dependent, ranging between 1692 and 1767°C at log (PO 2 ) values from -4.42 to -0.70.

36 MATERIALS SCIENCE↗

Helium Degassing Filter for Mercury Process Gas Liquid Separator

Testing was conducted to find a suitable filter to help separate helium gas from the Spallation Neutron Source’s mercury process loop. This filter is proposed for installation on the gas-liquid separator (GLS) vent line to prevent a column of liquid mercury from flowing outside of the process loop shielding in the service bay. The filter’s desired properties are to prevent the passage of liquid mercury, provide minimal resistance to helium flow, resist radiation, operate for the lifetime of the target, be replaceable, and have a reliable construction. Testing concluded that the Mott Corporation POU-10-S series of filters provided the best performance available. The filters could stop most liquid mercury passage while allowing helium passage at nominal pressures above the GLS in standard conditions. This result has several implications for the design of the GLS vent system.

Weinmeister, Justin↗

Bifurcation Buckling Analysis and Non-Linear Collapse Analysis of Teardrop Shaped Vacuum Chamber

The Spallation Neutron Source (SNS) accelerator is being upgraded to increase the beam power from 1.4MW at 1GeV to 2.8MW at 1.3GeV. The currents in the middle two injection chicane magnets cannot simply be scaled up to accommodate the increased injection energy of 1.3GeV due to potential excessive H- stripping; the magnets must be replaced with longer, lower-field magnets and the associated vacuum chambers need to be redesigned. A new teardrop-shaped vacuum chamber was initially designed to accommodate the new magnets and the updated beam paths and instrumentation. This paper focuses on the structural stability study of the teardrop shape vacuum chamber based on buckling analysis. Protection against collapse from buckling according to the ASME BPVC requirement has been evaluated in depth. First, a Type-1 bifurcation buckling analysis using a linear eigenvalue solution to determine the critical load factor was performed. Subsequently, a Type-3 nonlinear collapse analysis was conducted using the static Riks method with elastic-plastic material properties and imperfections explicitly considered in the model geometry. The critical buckling load for the teardrop shape vacuum chamber was confidently estimated based upon this two-stage approach.

Jiang, Hao↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

Observation of coherent elastic neutrino-nucleus scattering

The coherent elastic scattering of neutrinos off nuclei has eluded detection for four decades, even though its predicted cross section is by far the largest of all low-energy neutrino couplings. This mode of interaction offers new opportunities to study neutrino properties and leads to a miniaturization of detector size, with potential technological applications. In this paper, we observed this process at a 6.7σ confidence level, using a low-background, 14.6-kilogram CsI[Na] scintillator exposed to the neutrino emissions from the Spallation Neutron Source at Oak Ridge National Laboratory. Characteristic signatures in energy and time, predicted by the standard model for this process, were observed in high signal-to-background conditions. Finally, improved constraints on nonstandard neutrino interactions with quarks are derived from this initial data set.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The nEDM experiment at the SNS

The nEDM collaboration proposes to measure the neutron electric dipole moment at the Spallation Neutron Source (Oak Ridge National Laboratory). The nEDM is a clear signature of CP violation. According to the Standard Model the nEDM is very small (∼10{sup −31} e cm), but many theories predict much higher values. In the proposed experiment polarized cold neutrons from the SNS would be trapped in liquid helium at a temperature of about 400 mK. The neutron spin would precess in a very uniform magnetic field (H ∼ 30 mG), and the experiment would measure the change in the precession frequency when a very strong electric field (E ∼ 50 kV/cm) is applied. Polarized {sup 3}He atoms serve as a co-magnetometer. The goal of the experiment is to measure the nEDM with an accuracy of ∼9 × 10{sup −28} e cm, which is more than an order of magnitude better than existing results.

43 PARTICLE ACCELERATORS↗

Characterization of the correlated background for a sterile neutrino search using the first dataset of the JSNS$^2$ experiment

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that is searching for sterile neutrinos via the observation of ν¯ μ → ν¯ e appearance oscillations using muon decay-at-rest neutrinos. Before dedicated data taking in the first-half of 2021, we performed a commissioning run for 10 days in June 2020. Using the data obtained in this commissioning run, in this paper, we present an estimate of the correlated background which imitates the ν¯ e signal in a sterile neutrino search. In addition, in order to demonstrate future prospects of the JSNS 2 experiment, possible pulse shape discrimination improvements towards reducing cosmic ray induced fast neutron background are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study on the accidental background of the JSNS$^2$ experiment

JSNS 2 (J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment that searches for sterile neutrinos via the observation of $\overline{v}$ μ → $\overline{v}$ e appearance oscillations using muon decay-at-rest neutrinos. The JSNS 2 experiment performed data taking from 2021. In this manuscript, a study of the accidental background is presented. The rate of the accidental background is (9.29 ± 0.39) x 10 –8 /spill with 0.75 MW beam power and comparable to the expected number of signal events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Cryogenic control system operational experience at SNS

Abstract The helium cryogenic system at Spallation Neutron Source (SNS) provides cooling to 81 superconducting radio frequency cavities. To support the operation of the cryogenic facility, a highly reliable control system consisting of software, hardware, and Human Machine Interface (HMI) has been developed and improved during the first fifteen years of operation. Integrating the cryogenic control system with other subsystems of the SNS complex is an important aspect to the success of the operation. The operating experience, lessons learned and recommendations to consider for future facilities will be detailed in this paper.

Howell, M. (ORCID:0000000310360707)↗

QuickNXS

Data reduction software for the Oak Ridge National Laboratory Spallation Neutron Source's Magnetism Reflectometer beam line 4A, used to extract reflectivity, off-specular and GISANS scattering from raw data in NeXus file format. The package consists of a Python library for the extraction and a Qt4 based graphical user interface to work with the data.

Glavic, ArturGregor↗

Imaging Bragg Edge Analysis TooLs for Engineering Structures (iBeatles)

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL) provides pulsed neutrons with energies varying from epithermal to cold. In preparation for VENUS, the neutron imaging beamline to be located at beam port 10, we have performed a series of experiments focused on wavelength-dependent radiography and computed tomography for a broad range of applications, from materials science to biological tissues.One of the time-of-flight (TOF) techniques that is of interest to the scientific community is the 2-dimensional mapping of phases and average crystalline plane orientation in samples both ex-situ and during applied stresses such as tensile loading and heating. This technique is known as Bragg edgeimaging and relies on the identification of changes of transmission values, fitting of the edge to measure its displacement, and thus identify the shift in lattice parameter due to stresses. One of the challenges of TOF imaging measurements is the amount of data and the inability to observe Bragg edge shifts in real time during an experiment. Thus, we have been focusing on creating a Python-based interface that allows fast data processing and instantaneous mapping and fitting of the Bragg edges, and their evolution through time. Python libraries and Jupyter notebooks have been implemented to facilitate decision making during an experiment. The advantage of the notebooks is the possibility to guide an experiment as they can quickly process and display Bragg edge data. These notebooks can be used independently, or can be combined in a Python Graphical User Interface (GUI) tool called iBeatles. This interface permits visualization and fitting of the Bragg edges, and ultimately back-projects the fitting results onto the radiographs to display a strain map. Assuming data collection has sufficient statistics, the strain mapping analysis can be performed on a pixel-by-pixel basis. This development is a step forward toward a better user experience at the future VENUS beamline in terms of live feedback and productivity. Analysis that used to take days of switching between different applications can now be done in minutes within the

Bilheux, JeanChristophe [Oak Ridge National Labora↗

Process and control variables from the mercury loop at the SNS's mercury target

Set of process and control variables corresponding to the mercury process loop at the Spallation Neutron Source's (SNS) mercury target. The data corresponds to 36 measurement signals (pressure, temperature, flows, valve position, etc.) spanning from 2017/01/01 to 2023/12/31. Each signal is broken intro three-month intervals, resulting in a total of 28 files per signal during the aforementioned period of time.

mercury loop↗

Machine Learning assisted optimization and parameter space exploration dataset of spin ice Hamiltonian

This repository contains both simulated and experimental structure factor data for the data challenge involving the inverse scattering problem. The simulated data were generated during a machine-learning-assisted optimization routine described in ref[1]. The experimental structure factor was measured on a rare-earth oxide, Dy2Ti2O7 using diffuse neutron scattering from time-of-flight techniques on the CORELLI instrument at the Spallation Neutron Source, Oak Ridge National Laboratory. A Metropolis Monte Carlo code implemented to run in a High-performance computing setting was used to calculated simulated structure factors for the spin-ice Hamiltonian at 680 mK, which is the same temperature as for the experimental data. The total size of all the files in this repository is 5.12 GB. A detailed description of the files is given below. ExperimentalData_630mK.dat – A linearized version of 3-dimensional experimental data of size 61×81×21. This data was processed to remove an estimation of non-magnetic background, including nuclear scattering signal and instrumentation background. Parameters.dat – 6700 samples were evaluated over the 4-dimensional parameter space (J_1, J_2, J_3 and J_(3^' )). There is an additional parameter, D in the spin Hamiltonian to mimic the dipolar interaction between magnetic ions. However, this parameter, D was fixed to a value determined by prior work. This file contains five columns for the parameters J_1, J_2, J_3, J_(3^' ) and D respectively. 3D_Simulation_Data.dat – The simulated structure factor, S(Q) data are included in this file. Each raw contains a linearized array of 3D volumes of S(Q) calculated for the parameter set given in the corresponding row of the file Parameters.dat. The size of the volume data was matched to the experimental data. Qx(h,-h,0).dat, Qy(k,k,-2k).dat, Qz(l,l,l).dat – These files contain the h, k, and l values along with the reciprocal vectors [h,-h,0], [k,k,-2k] and [l,l,l] respectively.

36 MATERIALS SCIENCE↗

NOMAD total scattering dataset for SMC data challenge

The data provided for this challenge was measured using the Nanoscale-Ordered Materials Diffractometer (NOMAD) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The data is stored in a hdf5 file following the NeXus standard and can be read with tools built for either. While the NeXus format is self-describing, there is benefit to explaining some details. The data is stored in 4 NXentries in the file. The NXentries that begin with 'amorphous_SiO2' are for the amorphous data, and the NXentries that begin with 'crystalbolite_SiO2' are for the crystalline material. Solutions that were produced by the scientist are in the entries that end with '_byhand'. Each of the NXdata groups are the plottable data with the 'signal', axes, and (in the case of by-hand components) 'auxiliary_signals' describing which fields should be used. The by-hand component ranges are listed in a 'component' attribute of the various signals. The filtered Sr data is the Fourier transform of the combined components. The data can be quickly viewed using tools such as Nexpy or HDFview. Most languages have libraries that can work with HDF5 (eg. H5py for python) a partial list is provided at https://manual.nexusformat.org/utilities.html The data can be quickly viewed using tools such as Nexpy or HDFview. https://neutrons.ornl.gov/nomad https://www.hdfgroup.org/solutions/hdf5 https://www.nexusformat.org/

36 MATERIALS SCIENCE↗

Inelastic Neutron Scattering Data for FeSn

Inelastic neutron scattering data from FeSn collected with the SEQUOIA spectrometer at the Spallation Neutron Source located at Oak Ridge National Laboratory. A 4.43 g sample of FeSn was used for the measurements as described in doi: https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data were collected with an incident energy of 500 meV. The Fermi chopper frequency was 480 Hz, which provides a resolution of 38.2 meV (FWHM) for elastic scattering. Additional details are available in https://doi.org/10.1103/PhysRevB.105.L180403 and the associated supplemental information. The data may be viewed and analyzed with the software packages Mantid (http://dx.doi.org/10.5286/SOFTWARE/MANTID) and Dave (doi: 10.6028/jres.114.025). Sample angles measured: -20 deg to 20 deg and 160 deg to 200 deg where 0 deg is defined for ki//c* Sample Orientation vectors: ‘u': '-0.0032, 0.0201, -1.0' ‘v': '-1.0, 0.0278, -0.0059'

Inelastic Neutron Scattering↗

SNAP diffraction dataset for 2023 SMC data challenge

The data provided this challenge is ice under high pressure measured using the Spallation Neutrons and Pressure Diffractometer (SNAP) at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. The data is stored in a hdf5 file following the NeXus standard and can be read with tools built for either. While the NeXus format is self-describing, there is benefit to explaining some details. The data is stored in a single NXdata entry within a single NXentry. The NXdata has several fields denoting the 3-dimensional data (signal), the axes (D0 is the Qx axis, D1 is the Qy axis, and D2 is the Qz axis), and fields for the uncertainties and masking information. The data can be quickly viewed using the LoadMD algorithm and slice viewer in the Mantid workbench https://www.mantidproject.org.

36 MATERIALS SCIENCE↗