Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “slosh”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 667 records · Page 37

A Candle in the Wind: A Radio Filament in the Core of the A3562 Galaxy Cluster

Using a MeerKAT observation of the galaxy cluster A3562 (a member of the Shapley Supercluster), we have discovered a narrow, long and straight, very faint radio filament, which branches out at a straight angle from the tail of a radio galaxy located in projection near the core of the cluster. The radio filament spans 200 kpc and aligns with a sloshing cold front seen in the X-rays, staying inside the front in projection. The radio spectral index along the filament appears uniform (within large uncertainties) atα' −1.5. We propose that the radio galaxy is located outside the cold front, but dips its tail under the front. The tangential wind that blows there may stretch the radio plasma from the radio galaxy into a filamentary structure. Some reacceleration is needed in this scenario to maintain the radio spectrum uniform. Alternatively, the cosmic ray electrons from that spot in the tail can spread along the cluster magnetic field lines, straightened by that same tangential flow, via anomalously fast diffusion. Our radio filament can provide constraints on this process. We also uncover a compact radio source at the Brightest Cluster Galaxy (BCG) that is 2–3 orders of magnitude

S Giacintucci↗

Development and Validation of Two-Phase CFD Models for Key Elements of Propellant Tank CFM Operations in 1G and Microgravity – An Overview

This paper presents an overview of the state-of-the-art two-phase CFD models that have been developed for various propellant tank storage and transfer operations in 1g, partial gravity and microgravity. The models are developed in the framework of the industry standard ANSYS/Fluent CFD code, the capabilities of which have been significantly enhanced and customized through incorporation of unique submodels via User Defined Functions (UDF)s to satisfy the requirements of its intended variable gravity Cryogenic Fluid Management (CFM) applications. These models/submodels have been validated against experimental data that cross spatial scales, fluid types, and gravity levels in order to properly anchor the models’ physical and numerical fidelity. The CFM application/processes that have been modeled include tank self-pressurization, tank autogenous pressurization, tank pressure control using both subcooled jet mixing and droplet spray injection mechanisms, tank chilldown/filling, tank drainage, tank slosh for both volatile and non-volatile fluids. The strength and shortcomings of the two-phase models for each application is highlighted and discussed briefly.

Propellant Storage & Pressure Control↗

Development and Validation of Two-Phase CFD Models for Key Elements of Propellant Tank CFM Operations in 1G and Microgravity –An Overview

This paper presents an overview of the state-of-the-art two-phase CFD models that have been developed for various propellant tank storage and transfer operations in 1g, partial gravity, and microgravity. The models are developed in the framework of the industry standard ANSYS/Fluent CFD code, the capabilities of which have been significantly enhanced and customized through the incorporation of unique submodels via User Defined Functions (UDF)s to satisfy the requirements of its intended variable gravity Cryogenic Fluid Management (CFM) applications. These models/submodels have been validated against experimental data that cross spatial scales, fluid types, and gravity levels in order to properly anchor the models’ physical and numerical fidelity. The CFM application/processes that have been modeled include tank self-pressurization, tank autogenous pressurization, tank pressure control using both subcooled jet mixing and droplet spray injection mechanisms, tank chilldown/filling, tank drainage, tank slosh for both volatile and non-volatile fluids. The strength and shortcomings of the two-phase models for each application are highlighted and discussed briefly.

Computational Fluid Dynamics↗

Lunar Lander Landing Modeling and Simulation in Simscape

The landing gear is a critical subsystem of a lander for a successful landing on the moon or a planet. During a landing event, structural loading, energy absorption and toppling stability are important factors for the landing gear development. These aspects can be studied using simulations. The landing gear comprising the primary struct, secondary structs, footpad, and joints, is easily modeled using Simscape Multibody toolbox. The energy absorption mechanisms in the structs is readily modeled using Simulink and Multibody blocks based on the relative motions of the inner and outer cylinder of the structures. During touchdown, the footpads strike the lunar surface, and the contact forces can be modeled including the soil mechanical properties. Slosh dynamics are included using a mechanical pendulum model. Tip-over controllers are developed using Simulink blocks and toolboxes. This model was intensively tested manually then additionally with Monte Carlo simulation. It offers the opportunity for landing stability study, i.e. the max slope a lander can land without tipping over in 3D realistic landing situations.

Wei Wu↗

Loci/STREAM Sharp Interface Model Validation of Cryogenic Propellant Tank Self-Pressurization

This paper documents a model validation effort for the prediction of cryogenic propellant tank selfpressurization physics using the Loci/STREAM sharp interface CFD model developed at NASA MSFC. Cryogenic fluid management (CFM) applications for long duration spaceflight missions require accurate modeling of heat transfer and thermodynamics. Therefore, detailed validation of those physics is important to ensure simulation accuracy. In the past, the MSFC Propulsion Fluid Dynamics Branch has validated and used the Loci/STREAM Volume of Fluid (VOF) module extensively for propellant slosh applications, which are dominated by fluid motion. For cases where the interface gas/liquid interface is essentially static, the Loci/STREAM sharp interface was developed for more rapid and efficient CFM analysis. In the present study, Loci/STREAM sharp interface simulations were compared with the NASA K-site self-pressurization experiment of a flight weight, partially full, LH2 tank in normal gravity. This study investigated several parametric effects and made a number of important observations on the performance of the Loci/STREAM sharp interface method: - First, a homogeneous model was derived to verify the CFD model. The homogeneous model assumes both gas and liquid phases are uniform and are at saturation temperature. The predicted pressure rise rates at 3.5 W/m2 and 2.0 W/m2 with a 49% fill level are all lower than the experimental measurement. This is expected due to the observed temperature stratification near the gas-liquid interface during testing. - The k-w and k-e turbulence models predict comparable pressurization rates, which are much lower than the experiment measurement. On the other hand, the pressure values and pressurization rates from both models are almost the same as those of the homogeneous model. The current turbulence model is too diffusive and is not capable of capturing the thermal stratification in the liquid and ullage. - When using the laminar flow model, the pressurization rate is found to be very close to the experimental value when a quasi-steady flow field is allowed to develop by continuously venting the tank prior to pressurization as was done during testing. On the other hand, without initial venting, the rate is not constant. Additionally, the development time to reach a quasi-steady flow field differed from the experiment due to the lack of turbulent mixing away from the gas-liquid interface that is expected in reality. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 15% of the experimental value for 49% fill level at 3.5 W/m 2 and is within 18% for 2.0 W/m 2 heat loading. - Using the laminar flow model and appropriate initial conditioning, the pressurization rate is within 18% of the experimental value for a 29% fill level and within 15% for an 83% fill level.

H. Q. Yang↗

Cryogenic Propellant Tank Self-Pressurization and Active Pressure Control

This AIAA Short Course lecture will present an overview of different experiments and computational modeling work that has been done to examine different aspects of pressurization and pressure control of a Cryogenic propellant tank. The lecture will cover several large-scale ground-based liquid Hydrogen cryogenic self-pressurization experiments that were performed at NASA Glenn and NASA Marshall, LN2 Nitrogen autogenous pressurization experiments, pressure control experiments using both subcooled jet mixing and subcooled droplet injection, and experiments that examined pressure drops that occur during tank sloshing. Numerical modeling and simulations that were done in association to these experiments as part of a comprehensive model validation effort will also be presented and discussed. Finally, the results of two simulant fluid pressurization and pressure control microgravity investigations performed as part of the Tank Pressure Control Experiment (TCPE) and The Zero-Boil-Off Tank (ZBOT)Experiment will also be presented.

Propellant Management↗

Cryogenic Fluid Management Using CFD - Development and Applications

The Fluid Dynamics Branch has positioned itself to support a wide range of customers in need of Cryogenic Fluid Management (CFM) analysis. A computational fluid dynamics (CFD) tool used for all manner of internal and external propulsion applications has been extended and refined to better model cryogenic propellant storage and tanking operations. Through the CFM Portfolio project, several validation activities were initiated. Validation of propellant tank self-pressurization, autogenous pressurization, slosh-induced ullage collapse, and jet-induced mixing all aid in defining model accuracy. The on-going validation effort has enabled confident application of the tool to in-line design and evaluation of CFM hardware and operations. Recent project support included design of no-vent fill operations using various techniques for the Human Landing System (HLS). Propellant transfer dynamics were predicted to ensure complete propellant delivery. Many more activities in support of HLS and other projects and programs were supported. The branch has engaged the CFM community to share recent findings and capabilities through conferences. To reach the wider community, a consolidation of fundamental findings from work on in-space pulsed settling maneuvers was distilled in an AIAA paper. Development and demonstration of CFM modeling capabilities continues in order to meet the needs of the agency and its industry partners in the endeavor to sustainably reach the Moon and beyond.

Jacob Brodnick↗

Validation of Computational Fluid Dynamics Model for Pressurized Expulsion of Liquid Methane using Non-Condensable Pressurant

An important aspect of cryogenic fluid management is the design of the pressurization systems used to maintain and regulate the tank pressure as propellant is expelled from the tanks. To design these systems efficiently and effectively it is important to be able to predict the amount pressurant gas needed and how the pressurant gas affects the propellant as it is added in the tank. Computational fluid dynamics (CFD) modeling is a common tool that is used to help with these predictions, so it is crucial to have CFD models that are validated by comparing numerical results to experimental data. In the 1970’s extensive testing was done at NASA Plum Brook K-Site Facility exploring the pressurant gas requirements needed to maintain tank pressure while liquid methane is discharged from a spherical tank. These tests explored using different pressurant gases (methane, helium, hydrogen, and nitrogen) under static and sloshing conditions. The data gathered from the experiments includes the gas and wall temperatures at the end of the expulsion, the gas concentrations, and the total amount of pressurant added. This study presents a CFD model that accurately predicts similar results to the experimental data specifically for the tests in which helium, a non-condensable gas, was used. This comparison anchors the commercial CFD code Flow3D model and gives confidence for future use in design and analysis of pressurization systems for cryogenic propellant tanks

computational fluid dynamics↗

VALIDATION AND DETERMINATION OF SIGNIFICANT SIMULATION PARAMETERS USING THE SMOOTHED PARTICLE HYDRODYNAMIC CODE NEUTRINO

In recent years there has been an increase in flooding concern to nuclear power plants; thus, tools to reduce the cost of mitigation efforts are valuable to industry. Simulating flooding events is achieved through different methods and at varied levels of detail. However, these simulations must be able to match application conditions, which requires code validation as well as knowledge of which parameters affect the accuracy of the simulation. To validate and determine the significant parameters for these tools, a sloshing experiment was conducted at the George Washington University and then simulated with the smoothed particle hydrodynamic code Neutrino. The simulation setup was constructed to match the experiment as closely as possible, and the end-wall pressure results were analysed. The 90% and 50% end-wall pressure bounds were compared along with the pressure impulse. The simulation bounds fell mostly within the experimental bounds, with exceptions in insignificant low-pressure areas, such as at the beginning (~40% difference) and the end of the cycle (~40% difference). Another exception was seen at a point in the peak pressure (~75% difference). The simulated pressure impulse matched the experiments well and was within 10%. Additionally, seven parameters were qualitatively assessed and then investigated to determine their significance. The parameters’ significance was determined by sampling five values across the parameters’ range using the Risk Analysis Virtual Environment, then comparing the average pressure for each run. All seven parameters were identified as having some significance. However, the particle size, interaction-radius to particle-size ratio, and fluid settling seem to have a greater effect due to the larger fluctuation of the results. Now that the significant parameters are identified, further research is being done to quantify the significance of each parameter.

97 MATHEMATICS AND COMPUTING↗

Evaluation and improvement on external-hazard proof of JSFR fuel handling system

Responding to the the Fukushima Dai-ichi nuclear power plant (1F-NPP) accident, the earthquake and the tsunami proof of the fuel handling system (FHS) in Japan sodium-cooled fast reactor (JSFR) is studied. In the earthquake proof estimation, the margin of seismic resistance against the earthquake of the 1F-envelop condition and the sloshing behavior in the EVST is estimated. In terms of the tsunami proof, the scenario to lead fuel subassemblies into the stable cooling state and the potential of the cooling system is introduced in case of loss of the emergency power supply. As a result, it is clear that JSFR FHS originally could already be prepared to have the potential to prevent the release of radioactive material. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modification of an Agitated Tube Reactor for use in the Reprocessing of Spent Nuclear Fuel

Aims: Convert an Agitated Tube Reactor (ATR) into a counter-current solvent extraction device. Assess effect of liquid fill level on liquid dispersion. The agitated tube reactor (ATR) is an array of connected tubes. The ATR laterally shakes in a sinusoidal path, moving the agitator bar to create mixing. Originally designed by AM Technology as a cocurrent reactor, the ATR has many features that are potentially useful in the nuclear industry: Tubes are connected by non-moving seals; Reduction in seal damage and reduced risk of expensive repairs in radioactive environments; Minimal axial dispersion within a tube; Plug flow; Narrower residence time distributions that traditional technology; Multiple tubes allow for multiple reactions in series; Converting to a counter-current design allows the ATR to be used for solvent extraction; Reprocessing or decommissioning. A 180 ml PERSPEX ATR tube with no liquid flow through was constructed and filled with a 1:1 solvent:aqueous ratio of kerosene and water. The tube was filled such that the total liquid filled 25 %, 50 %, 75 % or 100 % of the tube. A Photron Fastcam SA5, positioned at the side and the end of the tube was set to a frame rate of 5400 fps with a resolution of 1024 x 1024 and 6000 fps with a resolution of 1024 x 896 respectively. Droplets were recorded after 2 minutes of shaking to ensure good mixing. Droplet sizes are used to determine optimum fill level in the ATR. The shaking frequency follows a sinusoidal path and was set to 5 Hz. The images shown in the results section were taken at the peak of the sinusoidal motion. To convert to a counter-current design the two liquids need to be separated at the end of each tube. Liquids have been allowed to separate under gravity separation. Inclusion of baffles to reduce remixing by sloshing. Wall with height corresponding to 25 % fill volume allows kerosene to overflow into separate outlet. Increase in liquid fill level decreases the dispersion of the two liquid phases. Higher dispersion of droplets decreases surface area and therefore increases mass transfer in solvent extraction. 25 % should provide the greatest mass transfer though more work needs to completed to confirm this.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗