AGR-3/4 Irradiation Test Predictions using PARFUME

PARFUME, a fuel performance modeling code used for high temperature gas reactors, was used to model the AGR-3/4 irradiation test using as-run physics and thermal hydraulics data. The AGR-3/4 test is the combined third and fourth planned irradiations of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The AGR-3/4 test train consists of twelve separate and independently controlled and monitored capsules. Each capsule contains four compacts filled with both uranium oxycarbide (UCO) unaltered “driver” fuel particles and UCO designed-to-fail (DTF) fuel particles. The DTF fraction was specified to be 1×10-2. This report documents the calculations performed to predict failure probability of TRISO-coated fuel particles during the AGR-3/4 experiment. In addition, this report documents the calculated source term from both the driver fuel and DTF particles. The calculations include the modeling of the AGR-3/4 irradiation that occurred from December 2011 to April 2014 in the Advanced Test Reactor (ATR) over a total of ten ATR cycles including seven normal cycles, one low power cycle, one unplanned outage cycle, and one Power Axial Locator Mechanism cycle. Results show that failure probabilities are predicted to be low, resulting in zero fuel particle failures per capsule. The primary fuel particle failure mechanism occurred as a result of localized stresses induced by the calculated IPyC cracking. Assuming 1,872 driver fuel particles per compact, failure probability calculated by PARFUME leads to no predicted particle failure in the AGR-3/4 driver fuel. In addition, the release fraction of fission products Ag, Cs, and Sr were calculated to vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 7 reaching up to 56% for the driver fuel and 100% for the DTF fuel. The release fraction of the other two fission products, Cs and Sr, are much smaller and in most cases less than 1% for the driver fuel. The notable exception occurs in Capsule 7 where the release fraction for Cs and Sr reach up to 0.73% and 2.4%, respectively, for the driver fuel. For the DTF fuel in Capsule 7, the release fraction for Cs and Sr are estimated to be 100% and 5%, respectively.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-D-201-00: Use of End-Of-Life Brachytherapy Devices

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

Fuel Performance Simulation of Iron-Chrome-Aluminum Cladding during Steady-State LWR Operation

During a severe accident scenario, such as a loss-of-coolant accident, a nuclear reactor may lose its capacity to cool its fuel. The fuel rod temperatures begin to increases, quickly reaching temperatures where the coolant begins to evaporate. This lowers the coolant level in the core and eventually uncovers the fuel. Without sufficient heat transfer from the fuel rods to the coolant, the temperature of the fuel and cladding will increase dramatically. In the case of traditional zirconium-based alloys, as the temperature of the cladding reaches ∼1200 deg. C the zirconium rapidly begins to oxidize with H{sub 2}O in the coolant and steam. This oxidation reaction causes both thinning of the Zr-alloy cladding as the metal reacts and releases large amounts of H{sub 2} gas into the reactor pressure vessel. In order to increase the safety margin of LWR fuel in severe accident scenarios, several alternative cladding materials have been proposed to replace the currently used zirconium-based alloys. Of these materials, there is a particular focus on select iron-chrome-aluminum (FeCrAl) alloys because of slower oxidation Kinetics in high temperature steam than zirconium-based alloys. This increased oxidation resistance may provide additional coping time to mitigate any further damage resulting from an accident. However, by changing the cladding material, the neutronic characteristics of the core will change. FeCrAl alloys exhibit thermal neutron absorption cross sections nearly ∼12-16 x greater than Zr-alloys. This decreases the reactivity of the core, subsequently decreasing the potential cycle length for operation. To counteract this, fissile material may be added in the form of increased enrichment or increased fuel mass or the cladding thickness might be decreased, effectively reducing the neutronic penalty from using the alloy. In this study, all three changes are considered. To assess the viability of FeCrAl as an alternative cladding to Zr-alloys, engineering-scale fuel performance analysis is used to monitor the cladding and integral fuel rod behavior through its operation. Ongoing work is being performed to identify key parameters essential to modeling FeCrAl alloys for LWR applications and properly model fuel compliance and stress relief mechanisms for UO{sub 2} fuel. To improve the predictive capability of fuel performance codes for FeCrAl cladding under normal operation, high-fidelity mechanistic/physics-based material models are needed. This information can be generated and improved by access to experimental data on targeted FeCrAl alloys. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

TU-PIS-Exhibit Hall-2: Deformable Image Registration, Contour Propagation, and Dose Mapping inMIM Maestro - MIM Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-3: Under the hood of Deformable Image Registration: Similarity Functions and Regularization

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-4: Philips Pinnacle3 clinical solutions for adaptive radiotherapy

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-5: ABAS - Atlas Based Auto Segmentation

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-01: Definition and Purpose of End-Of-Life for Brachytherapy Devices and Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-02: Physicist’s Responsibility On “End-Of-Life for Brachytherapy Devices and Software

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-D-201-03: Proposed Solutions to End-Of-Life Issue

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

TU-PIS-Exhibit Hall-1: Therapy: Deformable Image Registration, Contour Propagation, and Dose Mapping

Brachytherapy devices and software are designed to last for a certain period of time. Due to a number of considerations, such as material factors, wear-and-tear, backwards compatibility, and others, they all reach a date when they are no longer supported by the manufacturer. Most of these products have a limited duration for their use, and the information is provided to the user at time of purchase. Because of issues or concerns determined by the manufacturer, certain products are retired sooner than the anticipated date, and the user is immediately notified. In these situations, the institution is facing some difficult choices: remove these products from the clinic or perform tests and continue their usage. Both of these choices come with a financial burden: replacing the product or assuming a potential medicolegal liability. This session will provide attendees with the knowledge and tools to make better decisions when facing these issues. Learning Objectives: Understand the meaning of “end-of-life or “life expectancy” for brachytherapy devices and software Review items (devices and software) affected by “end-of-life” restrictions Learn how to effectively formulate “end-of-life” policies at your institution Learn about possible implications of “end-of-life” policy Review other possible approaches to “end-of-life” issue.

60 APPLIED LIFE SCIENCES↗

Lower hybrid current drive favoured by electron cyclotron radiofrequency heating

The important goal of adding to the bootstrap a fraction of non-inductive plasma current, which would be controlled for obtaining and optimizing steady-state profiles, can be reached by using the Current Drive produced by Lower Hybrid waves (LHCD). FTU (Frascati Tokamak Upgrade) experiments demonstrated, indeed, that LHCD is effective at reactor-graded high plasma density, and the LH spectral broadening is reduced, operating with higher electron temperature in the outer region of plasma column (T{sub e-periphery}). This method was obtained following the guidelines of theoretical predictions indicating that the broadening of launched spectrum produced by parametric instability (PI) should be reduced, and the LHCD effect at high density consequently enabled, under higher (T{sub e-periphery}). In FTU, the temperature increase in the outer plasma region was obtained by operating with reduced particle recycling, lithized walls and deep gas fuelling by means of fast pellet. Heating plasma periphery with electron cyclotron resonant waves (ECRH) will provide a further tool for achieving steady-state operations. New FTU experimental results are presented here, demonstrating that temperature effect at the plasma periphery, affecting LH penetration, occurs in a range of plasma parameters broader than in previous work. New information is also shown on the modelling assessing frequencies and growth rates of the PI coupled modes responsible of spectral broadening. Finally, we present the design of an experiment scheduled on FTU next campaign, where ECRH power is used to slightly increase the electron temperature in the outer plasma region of a high-density discharge aiming at restoring LHCD. Consequent to model results, by operating with a toroidal magnetic field of 6.3 T, useful for locating the electron cyclotron resonant layer at the periphery of the plasma column (r/a∼0.8, f{sub 0}=144 GHz), an increase of T{sub e} in the outer plasma (from 40 eV to 80 eV at r/a∼0.8) is expected by the JETTO code, sufficient for recovering LHCD. An ECRH power of 0.8 MW, and the standard FTU regime at high plasma density (n{sub eav}∼1.3×10{sup 20}m{sup −3} and plasma current of 0.5 MA) have been considered. The code has been set with transport modelling to reproduce the evolution of FTU kinetic profiles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-C-201-01: Investigation of the Effects of Scintillator Surface Treatment On Light Output Measurements with SiPM Detectors

Purpose: To examine the effect of different scintillator surface treatments (BGO crystals) on the fraction of scintillation photons that exit the crystal and reach the photodetector (SiPM). Methods: Positron Emission Tomography is based on the detection of light that exits scintillator crystals, after annihilation photons deposit energy inside these crystals. A considerable fraction of the scintillation light gets trapped or absorbed after going through multiple internal reflections on the interfaces surrounding the crystals. BGO scintillator crystals generate considerably less scintillation light than crystals made of LSO and its variants. Therefore, it is crucial that the small amount of light produced by BGO exits towards the light detector. The surface treatment of scintillator crystals is among the factors affecting the ability of scintillation light to reach the detectors. In this study, we analyze the effect of different crystal surface treatments on the fraction of scintillation light that is detected by the solid state photodetector (SiPM), once energy is deposited inside a BGO crystal. Simulations were performed by a Monte Carlo based software named GATE, and validated by measurements from individual BGO crystals coupled to Philips digital-SiPM sensor (DPC-3200). Results: The results showed an increment in light collection of about 4 percent when only the exit face of the BGO crystal, is unpolished; compared to when all the faces are polished. However, leaving several faces unpolished caused a reduction of at least 10 percent of light output when the interaction occurs as far from the exit face of the crystal as possible compared to when it occurs very close to the exit face. Conclusion: This work demonstrates the advantages on light collection from leaving unpolished the exit face of BGO crystals. The configuration with best light output will be used to obtain flood images from BGO crystal arrays coupled to SiPM sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Simulation Aided Metallic Fuel Design

Nuclear engineering is reaching a domain space in which computational power and methods are starting to surpass the models that are used to simulate nuclear fuel rods. As these models are updated, simulations utilizing different compositions, operating conditions, fabrication techniques, and geometries can provide core designers with an important first step towards fuel qualification. Due to the cost associated with fuel irradiations, it can be expected that time and money spent building better fuel models may provide an attractive return during initial studies of advanced fuels, especially with regards to fuels beyond the extensively studied uranium oxide system. In general, the primary U.S. experience with irradiated fuel rods beyond traditional oxide fuel is with binary (U-Zr) and ternary (U-Pu-Zr) metal fuels. The bulk of the experimental data for metal fuels is obtained from rods irradiated in the EBR-II sodium fast reactor (SFR), thus many of the correlations developed for metal fuels comes from the post-irradiation (PIE) examination of EBR-II rods. One of the unique characteristics that set U-Pu-Zr fuels apart from traditional oxide fuels is the presence of different phases that develop in the fuel during irradiation. Each of these different phases has unique thermal, mechanical, and diffusive behavior. The transitions between these phases are not static as the initially homogenous zirconium diffuses towards the center and edge of the fuel rod, resulting in a low-Zr, high-U ring. Along with the differing material properties that occur in each phase, the increase in uranium corresponds to an increase in localized fission and power production. The direct coupling between the thermal and diffusion solves highlights one of the many examples of tightly coupled phenomenon that are present in nuclear fuel, and motivation for the development of codes that simultaneously solve each piece of physics in a fully-coupled manner.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pushered single shell implosions for mix and radiation trapping studies using high-Z layers on National Ignition Facility

Pushered Single Shells (PSSs) are another approach to Inertial Confinement Fusion implosions that employ high-Z materials in the innermost capsule layer (pusher) as a means to enhance radiation trapping and lower core ignition requirements. However, adding high-Z materials can also increase losses due to mix, provide extra tamping, and make the capsule emission opaque to x-ray diagnostics. The first PSS implosions performed on the National Ignition Facility use plastic ablators with a germanium (Ge) dopant as a high-Z surrogate in the pusher to isolate the effects of high-Z mix and radiation trapping without changing tamping. Using a 2-shock laser pulse, the PSS implosions are designed and symmetrized to reach 3.7 keV core temperatures. A low concentration (2.8%) Ge dopant is added to the innermost layer, and the resulting effects on mix and x-ray opacity are observed. The method of separated reactants is used to infer information about mixing between the deuterated plastic pusher and the capsule fill gas (25% tritium) from the resulting nuclear DT reactions. Radiation transport is studied via capsule emission x-ray spectroscopy and imaging. Both nuclear and x-ray data corroborate the hypothesis that the addition of Ge strongly affects the mix region through radiation losses but has a minimal effect on the core and the warm, unmixed regions. Simulations using diffusive and turbulent mix models agree qualitatively with data, but quantitative agreement may require hybrid mix models that can model the transitional regime between turbulence and diffusion. Simulations matching the observables show increased core radiation trapping when Ge is added.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Toroidal modeling of runaway electron loss due to 3D fields in ITER

Mitigation of runaway electrons (REs) by three-dimensional (3D) magnetic field perturbations is numerically investigated for the ITER 15 MA baseline D–T scenario, utilizing the MARS-F code (Liu et al Phys. Plasmas 7 3681) with a drift orbit test particle tracing module. Considered are two types of 3D fields: the n = 3 (n is the toroidal mode number) resonant magnetic perturbation (RMP) utilized for the purpose of controlling the edge localized modes in ITER, and perturbations generated by the n = 1 magneto-hydrodynamic (MHD) instabilities in a post-disruption plasma. The RMP field, applied to a pre-disruption plasma, is found to be moderately effective in mitigating the RE seeds in ITER when vacuum field model is assumed. Up to ~40% loss fraction is possible at 90 kA-turn coil current. The mitigation efficiency is however substantially reduced, down to less than 5%, when the plasma response is taken into account. This is due to strong screening of the resonant magnetic field components by the plasma response resulting in much less field line stochasticity. On the other hand, the MARS-F modeling, based on the DINA-simulated post-disruption equilibria, shows that the n = 1 resistive kink instabilities develop in these plasmas, as the edge safety factor qa evolves and drops below integer numbers. RE mitigation by these MHD instabilities is sensitive to the eigenmode structure. The best mitigation is achieved as q a drops below 3, when a global kink instability occurs that encompasses both internal and external components. This global instability is found to be capable of mitigating over 80% MeV-level passing RE orbits at a field perturbation |δB|/B 0 that is comparable to that observed in DIII-D experiments, and full mitigation if the perturbation amplitude is doubled. The 'wetted' area on the ITER limiting surface, due to MHD instability induced RE loss, generally increases with the perturbation amplitude (together with increasing loss fraction). At the highest perturbation level assumed in this study, the wetted area reaches ~60% of the total limiting surface area. Lastly, the lost RE orbits mainly strike the outer divertor region of the limiting surface, with some fraction also hitting a wide area along the inboard side of the surface.

3D fields↗

Test of a prototype neutron spectrometer based on diamond detectors in a fast reactor

A prototype of neutron spectrometer based on diamond detectors has been developed. This prototype consists of a {sup 6}Li neutron converter sandwiched between two CVD diamond crystals. The radiation hardness of the diamond crystals makes it suitable for applications in low power research reactors, while a low sensitivity to gamma rays and low leakage current of the detector permit to reach good energy resolution. A fast coincidence between two crystals is used to reject background. The detector was read out using two different electronic chains connected to it by a few meters of cable. The first chain was based on conventional charge-sensitive amplifiers, the other used a custom fast charge amplifier developed for this purpose. The prototype has been tested at various neutron sources and showed its practicability. In particular, the detector was calibrated in a TRIGA thermal reactor (LENA laboratory, University of Pavia) with neutron fluxes of 10{sup 8} n/cm{sup 2}s and at the 3 MeV D-D monochromatic neutron source named FNG (ENEA, Rome) with neutron fluxes of 10{sup 6} n/cm{sup 2}s. The neutron spectrum measurement was performed at the TAPIRO fast research reactor (ENEA, Casaccia) with fluxes of 10{sup 9} n/cm{sup 2}s. The obtained spectra were compared to Monte Carlo simulations, modeling detector response with MCNP and Geant4. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Spanning the Core Design Space with Binary Perturbations - A Mathematical Investigation

A reactor core design engineer, even one with many years of experience or one using advanced fuel pattern optimization software, will likely fine tune the pattern before finalizing the design. Fine tuning can further minimize local enthalpy peaks, optimize reactivity to extend burnup, and add additional margin to limits on reactivity coefficients or heat flux. For reactors that have reached an equilibrium fuel cycle, the number of feeds each cycle is typically the similar to previous cycles as is their placement in the core. It is then the engineer's responsibly to efficiently select the placement of burned assemblies to ensure optimal fuel utilization, satisfy safety limits, and meet cycle energy requirements. One of the engineer's most commonly used tools in this fine tuning investigation is to swap the positions of two assemblies, most likely two previously irradiated ('burned') assemblies since their reactivity is lower than fresh fuel. Such an operation is referred to in this work as a binary perturbation or a 'swap'. If quarter core symmetry is maintained, the perturbation translates to the other three quadrants. Likewise if eighth core symmetry is maintained, the perturbation translates to other seven octants. The question is then, how much of the core design space can binary perturbations possibly span? This work seeks to quantitatively define the space spanned by m number of binary perturbations as a function of variable size through combinatorial principles and computer simulation. The results of this study are useful in understanding the in-core fuel management problem faced by both professionals who employ hand manipulations and those who attempt stochastic solutions of the problem.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗